NATURAL GAS LIQUID MEASUREMENT: DIRECT AND INFERRED MASS BY DEAN MINEHART, MICRO MOTION, INC.

Similar documents
ROC800L Liquid Application Software

Micro Motion ELITE CMFS Series Meter

MICRO MOTION 5700 TRANSMITTER SECURITY FEATURES AND BEST PRACTICES BY JASON LEAPLEY, MICRO MOTION, INC.

Fiscal Measurement Natural Gas

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class # 2010

Micro Motion Net Oil Computer Software and NOC System

Oil and Gas Custody Transfer

TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

Micro Motion 3098 Gas Specific Gravity Meter

Manual of Petroleum Measurement Standards Chapter 11 Physical Properties Data

FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS. Sami Halilah Dynamic Flow Computers Houston, Texas

The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers

LESSONS LEARNED FROM THE API 14.1 GAS SAMPLING RESEARCH PROJECT. Darin L. George and Eric Kelner

Oilfield Services Measurement Solutions

Balancing chemical reaction equations (stoichiometry)

Daniel Venturi Tubes and Flow Nozzles Brochure

Chemical Measurement Solutions

Rosemount Orifice Plate in Wet Gas

1. Standard conditions are in. Hg (760 mm Hg, psia) and 68 F (20 C).

Chromatograph Maintenance and Troubleshooting Class # 5050

BTU ANALYSIS USING A GAS CHROMATOGRAPH

AN INSTRUMENT FOR GRAVIMETRIC CALIBRATION OF FLOW DEVICES WITH CORROSIVE GASES. J. O. Hylton C. J. Remenyik Oak Ridge National Laboratory *

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

Natural Gas. Shale Gas Impacts. Natural Gas Liquids (NGLs) Dan Brockett Penn State Extension

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

1 Introduction The Scientific Method (1 of 20) 1 Introduction Observations and Measurements Qualitative, Quantitative, Inferences (2 of 20)

Chapter Test B. Chapter: Measurements and Calculations

FLOW METER SPECIFICATION AND APPLICATION ANALYSIS Class #41

ISO Accreditation for a Standing Start Finish (SSF) Primary Flow Stand with Coriolis Flowmeters as Reference Standards.

UPM Figure 1 MPFM installed on well pad

TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL

vap H = RT 1T 2 = kj mol kpa = 341 K

The Fundamentals of Gas Flow Calibration

Micro Motion Model D and DL Coriolis Flow and Density Meters

Using meters to measure steam flow

Optimization of Natural Gas Processing Plants Including Business Aspects

Chemistry 13: States of Matter

Flow System Calibration in Medical and Bio-medical Production Processes.

ECONOMICAL OPTIONS FOR RECOVERING NGL / LPG AT LNG RECEIVING TERMINALS

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

OIL & GAS PRODUCTION AUDITING

ASimple Guide to Oil Refining

Measurement & Analytics. VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy

Lecture 9 Solving Material Balances Problems Involving Non-Reactive Processes

Regulations for custody transfer measurements: meeting the needs? Focus on liquid flow measurement systems/applications

Petrochemical Industry Ethylene Plant

COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink

OUR CONVERSATION TODAY

ROC800-Series Advanced Pulse Module

WEEK 1. Engineering Calculations Processes Process Variables

NOTE: FOR PROJECTS REQUIRING CONTRACTOR MIX DESIGN, THE DESIGN PROCEDURES ARE SPECIFIED IN THE SPECIAL PROVISIONS OF THE CONTRACT.

Energy and Flow Measurement for Hydronic Systems

AN IN-SITU VERIFICATION TECHNOLOGY FOR CORIOLIS FLOWMETERS

Roxar Multiphase meter 2600 Class - Turning information into value

Spartan Controls NET OIL COMPUTER PROGRAM Reference Manual

Case 6:12-cv Document 1 Filed 10/22/12 Page 1 of 14 PageID #: 1

ANNEX I GAS MEASUREMENTS AND TESTING AT THE DELIVERY POINT. Table of Contents

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

Micro Motion Coriolis Interface Module User Manual (for ROC800-Series and FloBoss 107 Controllers)

Fundamentals of Gas Chromatography

Form Number A6043. Part Number D301224X012 March Flow Measurement. User Manual. Flow Computer Division. Website:

Information on the New Royalty Framework

Air Eliminators and Combination Air Eliminators Strainers

PESTICIDE RATE AND DOSAGE CALCULATIONS

T U R B I N E G A S M E T E R

Natural gas liquids recovery from gas turbine fuel

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Oil and Gas Terms. Anticline: An arch of stratified rock layers that may form a trap for hydrocarbons.

AMS Suite: Intelligent Device Manager

GOOD PRACTICE GUIDE THE CALIBRATION OF FLOW METERS

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

Development of a model for the simulation of Organic Rankine Cycles based on group contribution techniques

DENSITY MEASUREMENTS OF LIQUID FUELS TO DETERMINE TEMPERATURE CONVERSION FACTORS FOR LEGAL METROLOGY

In-Line Electronic Flow Switches

71M6521 Energy Meter IC. Real Time Clock Compensation. The Challenge. The RTC in the 71M6521D/F. Theory of Operation APPLICATION NOTE

Gas Laws. The kinetic theory of matter states that particles which make up all types of matter are in constant motion.

AMS Suite: Intelligent Device Manager with the DeltaV system

Liquid level measurement using hydrostatic pressure and buoyancy

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

An Overview of Calibration Methods and Procedures for Process and Inventory Weigh Systems

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

Coal Gasification & Fischer-Tropsch

CHAPTER 1 : INTRODUCTION TO PROCESS CONTROL

Chapter 4. Chemical Energy

In-Line Electronic Flow Switches

THE BASICS Q: What is VOC? Q: What are flashing losses/voc emissions from hydrocarbon storage tanks? - 1 -

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Petroleum Measurement

The. Hoffer Collection. Perfecting Measurement " A powerful source of Turbine Flowmeters and Electronics for a wide range of flow applications.

Gas Supplies & Pricing Law

Chapter 1 Chemistry: The Study of Change

Memo WFC 423 DA. Water Fuel Injector System processes and converts water into a useful hydrogen fuel on demand at the point of gas ignition.

THE HUMIDITY/MOISTURE HANDBOOK

Chapter 1: Chemistry: Measurements and Methods

Evolution of the Thermometer

Custody Transfer Measurement. with the V-Cone Flowmeter

Transcription:

NATURAL GAS LIQUID MEASUREMENT: DIRECT AND INFERRED MASS BY DEAN MINEHART, MICRO MOTION, INC.

Introduction Natural Gas Liquid (NGL) streams consist of mixtures of hydrocarbons including ethane, propane, butane, pentane and natural gasoline. NGL is sometimes referred to as y-grade. The American Petroleum Institute (API) Manual of Petroleum Measurement Standards (MPMS) Chapter 14, Section 7 provides guidance on the mass measurement of NGL. Mass measurement techniques are applied to NGL to avoid measurement errors that are caused by the solution mixing within the NGL stream. Mass measurement can be achieved by direct measurement with a Coriolis flow meter or inferred by multiplying a volumetric flow rate times flowing density. There are important advantages to be aware of with direct mass measurement for NGL streams. Individual components in an NGL stream are bought and sold on a volumetric basis. There is a simple process to convert the measured mass of the combined NGL stream into the standard volumes of each individual component for this purpose. Hydrocarbon Solution Mixing NGL solution mixing results when different sized molecules flow together in a NGL stream. Smaller molecules fit within voids in the structure of larger molecules. An analogy can be made to mixing sand and marbles. Mixing one barrel of sand and one barrel of marbles yields less than two barrels of mixture (Figure 1.). This happens because the sand fills the spaces around the marbles that were empty when the marbles and sand were separate. Simultaneously varying the NGL stream composition, temperature, and pressure makes it impossible to predict the resulting volume of the hydrocarbon mixture. It is not possible to apply temperature and pressure volume correction factors from API MPMS Chapter 11 on NGL streams for this reason. A NGL stream s measured mass is the only possible accurate measurement of true quantity because mass is independent of composition, temperature, pressure and solution mixing. Mass/Volume/Density Relationships Mass, volume and density are related. Relationships are shown below: Mass = Volume x Density Volume = Mass / Density Density = Mass / Volume Figure 1. Mass can be measured directly using a Coriolis flow meter or inferred by measuring volume and density at flowing conditions. Dividing mass by density at flowing conditions yields indicated volume. Volume at standard conditions can be determined by dividing mass by the density at standard conditions. This topic will be discussed again later in reference to converting mass into volume for the purpose of generating a measurement ticket. Direct Mass Measurement Direct mass measurement is achieved by using a Coriolis flow meter and programming the transmitter to output pulses per unit mass (pulses per pound). Coriolis flow meter installations should follow the guidance provided in API MPMS Chapter 5, Section 6. API MPMS Chapter 14, Section 7 provides an equation for direct mass measurement: Qm = Im m xmf m Where: Qm = mass flow Im m = indicated Coriolis meter mass MF m = meter factor for Coriolis meter mass Page 2

Micro Motion, Inc. The direct mass equation includes only two terms. T TW P T TW P Direct mass meters require that a mass meter factor be derived by mass proving. This requires the addition of an online density measurement at prover conditions (prover volume x density = mass) if a volume prover is used. Inferred Mass Measurement Inferred mass measurement is achieved by using a volumetric flow meter in conjunction with an online density measurement at flowing conditions. Volumetric flow meters should be installed with guidance from an appropriate section of the API MPMS Chapter 5 depending on the meter technology selected (e.g. API MPMS Chapter 5, Section 3 for turbines). API MPMS Chapter 14, Section 7 provides an equation for inferred mass measurement: Q m = IV x MF v x ρ f x DMF Where: Q M = mass flow IV = indicated meter volume at operating conditions MF v = volumetric meter factor ρ f = observed density at operating conditions DMF = density meter factor The inferred mass measurement calculation has two additional terms for a flowing density and a density meter factor. Inferred mass density measurement guidance is provided by API MPMS Chapter 14, Section 6 (this document will be superseded by API MPMS Chapter 9, Section 4 in the near future). Because of their size and limited flow rate capacity, density meters (Figure 2 DT ) are generally installed in a bypass loop from the main flow line. Maintaining conditions (i.e., pressure, temperature and composition) of the sample flowing through the density bypass loop such that the sample density is representative of the product flowing through the volumetric (duty) flow meter can be a challenge. Differences in process conditions between the duty flow meter and the density meter will result in additional mass measurement errors that do not exist in a direct mass measurement system. T TW P Figure 2. Density Meter Loop Density Measurement Density measurement is required on a volume prover for direct mass proving. Density meters are often placed on a piston prover s outlet across a valve or other restriction to create flow through the density loop. Inferred mass measurement systems have a continuous density measurement loop as described above. Density loops should include pressure (P) and temperature (T) measurements at the density meter (DT) and pycnometer (PYC) outlets in order to ensure equal process conditions when a pycnometer sample is pulled. Regardless of where a density loop is located, a density meter factor is required. API MPMS Chapter 14, Section 6 provides guidance on calibrating density meters against a pycnometer. Sampling for Composition A flow-weighted, proportional fluid sample is collected during the measurement interval. The sample pressure must be maintained above the fluid vapor pressure in order to prevent liquid-vapor separation from occurring in the sample container or the composition of the sample will no longer be representative of the flow stream. The fluid samples are then analyzed by gas chromatography in order to determine the weight fraction of each component in the fluid stream at the time that the total mass measurement was made. Online Analysis DT Many operating companies have adopted online fluid analysis using gas chromatographs installed near the mass measurement system. A gas chromatograph (GC) measures the flowing fluid composition and provides compositional data to a flow computer. Online analysis is used to eliminate a need for handling and processing manual samples. Gas Processors Association Standards GPA 2261 and GPA 2177 provide some guidance on GC NGL measurement applications. PYC FI Page 3

Converting the Total Mass into the Standard Volumes for Each Component The API MPMS Chapter 14, Section 4 provides guidance for converting NGL mass quantities to equivalent volumes. NGL samples obtained during the measurement period are analyzed to determine the weight fraction of each stream component or measured in real time via an online Gas Chromatograph (GC). The weight fraction of each component is multiplied by the total NGL mass, which yields the individual mass quantities of each component. Dividing each component mass by the density at standard conditions that is published for each pure component provides the standard volume at reference conditions of each NGL stream component. Table 1. below shows an example mass to volume conversion of a NGL stream. Conclusion Mass measurement techniques are used very effectively to measure NGL. Solution mixing makes predicting NGL volumes impossible under varying composition, pressure and temperature. Several sections of the API MPMS provide guidance for the mass measurement of NGL. NGL mass can be measured directly with Coriolis flow meters. Inferred mass can be determined by multiplying a volumetric flow meter volume times density. Direct mass measurement systems have the distinct advantage of not needing online continuous line density measurement during the measurement interval. NGL mass is converted to the individual component volumes by determining the mass of each component from the GC analysis and dividing by the density of each pure fluid at standard reference conditions. Emerson Process Management has expertise in the area of NGL mass measurement systems and a wide variety of products and solutions to automate these systems. We have application expertise in the areas of flow computers/meters, gas chromatography and pressure/ temperature measurement on NGL mass measurement systems. Contact a local Emerson Process Management sales office for a solution to your needs today. Table 1. Example Total Mass to Component Volume Conversion Page 4

About Micro Motion For over 39 years, Emerson s Micro Motion has been a technology leader delivering the most precise flow, density and concentration measurement devices for fiscal applications, process control and process monitoring. Our passion for solving flow and density measurement challenges is proven through the highly accurate and unbeatable performance of our devices as well as the quality of our services. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warrantees or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the design or specification of such products at any time without notice. Emerson Process Management Micro Motion 7070 Winchester Circle Boulder, Colorado USA 80301 T: +1 800 522 6277 T: +1 (303) 527 5200 F: +1 (303) 530 8459 www.micromotion.com WP-002037 Rev A 2016 Micro Motion, Inc. All rights reserved.