Industrial Pt100 RTD's

Similar documents
Threaded Resistance Thermometers Model TR10-D, Miniature Design

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Plastic tube flowmeters Series PT/PS

Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)

Compact pressure switch Flameproof enclosure Ex d Model PCA

RTD Temperature Probe for the Food/Pharmaceutical Industry

Flow switches Series AD/VH

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Threaded resistance thermometer Model TR10-C, with protection tube

Toroidal Conductivity Sensor

SITRANS F flowmeters SITRANS F M

Self-operated Temperature Regulators Temperature Regulator Type 1u

Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

THERMOCOUPLES GENERAL DESIGN AND SELECTION THERMOCOUPLE STANDARD

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Electronic Flow Switches

Thermometer in stainless steel with capillary and switch contacts

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Hose Clamps & Fittings

Bypass level indicator With magnetic display Model BNA

Pipe Temperature Sensors

Turbine Flow Sensor Series VTR

Micro Motion Model D and DL Coriolis Flow and Density Meters

The Unique Accelabar Flow Meter

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

RUBBER SLEEVE KNIFE GATE VALVE

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Quick Connect. RTDs, Cordsets and Transmitter with M12 Connections

How To Use A Flowmeter

Stainless steel process fittings

Cables. Accessories. For Force, Torque and Strain Sensors

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Mini USB and USB 2.0-IP67 Connector System

Engineered Solutions

Portable digital microprocessor thermometers with interchangeable probes

Operating Instructions

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

OPTIMASS 6000 Technical Datasheet

Thermocouples & Thermoresistances

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Data Sheet PS1B Pressure Switch

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

In-Line Electronic Flow Switches

Submersion/Insertion Toroidal Sensor

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

OPTIMASS 1400 Technical Datasheet

Variable V Area Flowmeter Rotameter The Original

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

kymanual or Automatic - it s your Choice

Test equipment for temperature and its reduction

Many Products...One Source

API Flanged Safety Relief Valves Series 526 CATALOG

Thermatel Model TA1 Mass Flow Transmitter

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

BB-18 Black Body High Vacuum System Technical Description

Bimetal thermometer Model 52, industrial series

Technical data sheet TDS0070

Screw Plug Immersion Heaters

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Cerampak is weldable, flexible - can be bent on a radius 2 times its diameter - and moisture free when fabricated.

Digital inductive conductivity transmitter

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

SELECTION, APPLICATION AND MAINTENANCE

Thermostatic valve Type AVTA

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI

HOPPER SHAPE KNIFE GATE VALVE

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Sanitary Type Electronic Flow Switches

Givare NC-SRS 280 och 880

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Technical Information RIA14

Type 3353 Angle Seat Valve

TB2CS Conductivity sensor 2-Electrode. Superior accuracy in low level conductivity measurement ranges

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Quick Connect Boxes Inside Gloveboxes

Check Valves & Actuated Valves

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Rosemount 214C Temperature Sensors

Explosion proof enclosures

4 Posiflow Proportional Solenoid Valves

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

IFC 070 Technical Datasheet

How To Use A Ds340 (Dsp)

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

3/2-way Solenoid Valve, direct-acting, NC or NO

Mikrotherm. Manual radiator valves. To be precise.

Duct Temperature Sensors

ISO/VDMA Actuators. Engineering GREAT Solutions

S1VF Sonde à visser avec tête de raccordement Threaded probe with terminal head

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Transcription:

CA 2001 Resistance class B standard, optional class A, Welded process connection 1/2"BSP. Aluminium Replaceable 6mm Din standard measuring insert. Can be Type CA 2001 CA 2003 Resistance 600 C Max 60bar and media Welded process connection 1/2"BSP Head extension 50mm standard. Aluminium Replaceable 6mm Din insert. Can be Type CA 2003 CA 2004 Fast response resistance 600 C Max 60bar and media velocities of up to 8m/sec (air) or 0.9m/sec ( water). Closed-end 9mm 316SS acid-proof protection tube with 6mm tip. Welded process connection 1/2"BSP. included. Fixed insert, optional 3mm replaceable. Can be transmitter. Type CA 2004 CA 2005 Fast response resistance gaseous or liquid media. velocities of up to 8m/sec (air) or 0.9m/sec ( water). Closed-end 9mm 316SS acid-proof protection tube with 6mm tip. Welded process connection 1/2"BSP. Head extension 50mm standard. included. Fixed insert, optional 3mm replaceable. Can be transmitter. Type CA 2005

CA 2006 Resistance flanged to ANSI or DIN 3m/sec ( water). Closed-end 9mm, 11mm, 12mm or 14mm Proces connection by an welded flange to ANSI or to DIN. included. Replaceable 6mm DIN standard measuring insert. Can be Type CA 2006 CA 2008 Air temperature resistance gaseous media, e.g. air, steam, gas. Temperature range: -200 C to 600 C Max 1bar and media velocities of up to 10m/sec Perforated-end 9mm 316SS Welded 1/2"BSP process connection, head extension 50mm. Aluminium Replaceable 6mm Din standard measuring insert. Single or duplex. Optional head mounted CA 2007 Air temperature resistance gaseous media, e.g. air, steam, gas. Temperature range: -200 C to 600 C Max 1bar and media velocities of up to 10m/sec. Perforated 9mm, 316SS acidproof protection tube. Welded male process connection 1/2"BSP. Aluminium Replaceable 6mm Din standard measuring insert. Can be Type CA 2007 CA 2009 Fast response air resistance class B standard, optional class A, gaseous media, e.g. air, steam, gas. Temperature range: -200 C to 600 C. Max 1bar and media velocities of up to 1m/sec. Protection tube 9mm 316SS acidproof with perforated 6mm tip. Welded male process connection 1/2"BSP. Aluminium Fixed insert. Can be delivered with head mounted transmitter. Insertion length as Type CA 2009 Type CA 2008

CA 2012 Industrial resistance integrated transmitter Head mounted 4-20mA transmitter integrated. Precision wire-wound Pt100 detector Accuracy to IEC 751 class B standard, optional class A, 1/3DIN or 1/10DIN. Designed to measure temperatures in industrial environments with gaseous or liquid media, e.g. air, steam, gas, water or oil with current output. Welded male process connection 1/2"BSP. Aluminium Insertion length as Type CA 2012 CA 2016 General purpose resistance class B standard, optional class A, 600 C Max 60bar and media Compression gland or an adjustable sliding flange optional. included. Replaceable 6mm Din standard measuring insert. Can be Type CA 2016 CA 2017 Flanged resistance class B standard, optional class A, Proces connection by an adjustable sliding flange. included. Replaceable 6mm Din standard measuring insert. Can be Type CA 2017 CA 2018 Industrial resistance Process connection by 1/2"BSP compression gland with metal or Teflon ferrule. Aluminium gland M20x1.5mm. Replaceable 6mm Din standard measuring insert. Can be delivered with head mounted transmitter. Type CA 2018

CA 2021 Heavy duty resistance element for thermowells Designed to measure temperatures into thermowells and pockets at places with high vibrations and harsh environments. Temperature sensor range: -200 C to 550 C. Thermowell connection by a 1/2"NPT nipple union nipple. Aluminium connection head CE with threaded cover and chain. Stainless steel connection head optional. Cable entry M20x1.5mm. Replaceable 6mm springloaded insert. Sensor Pt100 2, 3 or 4 wire class A, B or better. Single or duplex. Can be delivered with head mounted transmitter. Insertion length as Type CA 2021 CA 2022 Industrial resistance 600 C Max 60bar and media Welded male process connection 1/2"NPT. Aluminium Replaceable 6mm Din standard measuring insert. Can be Type CA 2022 1/2"BSP Threaded Pt100 sensor with valve connector The DWR 6000 resistance with 1/2 "BSP threaded connection is provided with an valve connector according to DIN EN 175301. The sensor has a measuring range of -30 to + 180 C at a maximum pressure of 40 bar in a gaseous or liquid medium. The temperature can be screwed directly into barrels or tubes. Type DWR 6000 DWR 6001 Threaded Pt100 with integral transmitter & valve connector DWR 6001 resistance with integrated 4-20mA loop powered transmitter and a 1/2 "BSP threaded connection, is provided with an appliance plug ( valve connector) according to DIN EN 175 301. The sensor has a measuring range of -30 to + 180 C at a maximum pressure of 40 bar in the gaseous or liquid medium. The temperature sensor can be directly screwed into vessels or pipes. Measuring range of the transmiter to be specified. Type DWR 6001

MI 2025 springloaded replacement resistance insert 1/3DIN or 1/10DIN. Temperature range: -200 C to 600 C. Diameter 6.0mm, optional diameter 3mm, 3.2mm, 4.5mm, 6.4mm and 8mm. Mineral insulated, 316SS sheathed insert to DIN 43762. Suits any B-type connection head with 33mm fixing. Sensor wires are soldered or laser-welded to the terminals on the DIN standard ceramic terminal block. Material of terminals is nickel-plated brass. Max. connection wire diameter 3mm. Detector is isolated from the sheath. High vibration detector or Chip type version possible. Type MI 2025 MI 2027 Springloaded resistance insert Mineral insulated, 316SS sheathed insert with 125mm central spring design. Designed for NPT mounted Nipple Unions Nipple and Thermowells connections. Ensures possitive contact with the thermowell bottom. Precision wire-wound Pt100 1/3DIN or 1/10DIN. Temperature range: -200 C to 600 C Diameter 6.0mm ( 3mm,3.2mm, 4.5mm, 6.4mm and 8mm optional ). Suits any B-type connection head with 33mm pitch. Max. connection wire diameter 3mm. Detector is isolated from the sheath. MI 2026 resistance insert for 4-20mA transmitter Mineral insulated replacement measuring insert suits DIN-B type headmount transmitter. Transmitter can be fitted directly on the probe. Standard 60mm PTFE insulated connection wires. 1/3DIN or 1/10DIN. Temperature range: -200 C to 600 C Diameter 6.0mm ( 3mm,3.2mm, 4.5mm, 6.4mm and 8mm optional ). Can be delivered with any brand head mounted transmitter. Standard Head Mounted Transmitters see separate chapter to select or specify your standardized brand and model. Type MI 2026 MI 2038 Fixed insertion resistance Rigidly mounted vibrationproof Pt100 replacement probe. SS316 hex nipple with 1/2" NPT mounting thread on both sides. Seal welded to the probe. Pt100 connected in a 2, 3 or 4 wire system. Temperature range: -200 C to 600 C. Single or duplex. Accuracy to IEC 751 class B standard optional class A, 1/3DIN or 1/10DIN. Diameter 6.0mm (3mm, 4.5mm, 6.4mm and 8mm optional) Mineral insulated, 316SS sheathed. Detector is isolated from the sheath. PTFE insulated flexible connection wires 150mm. Type MI 2038 Type MI 2027

MI 2039 Springloaded resistance Rigidly mounted vibrationproof Pt100 RTD replacement probe. SS316 hex nipple. Springloaded 25mm of travel. 1/2"NPT mounting thread on both sides. Pt100 Measuring system connected in a 2, 3 or 4 wire system. Temperature range: -200 C to 600 C. Single or duplex. Accuracy to IEC 751 class B standard Optional class A, 1/3DIN or 1/10DIN. Diameter 6.0mm (3mm, 4.5mm, 6.4mm and 8mm optional) Mineral insulated, 316SS sheathed Detector is isolated from the sheath. PTFE Insulated flexible connection wires 150mm. Type MI 2039 RV 2095 Wall mounted resistance Wall mounted Pt100 sensor for air temperatures indoor and outdoor. Pt100 sensor connected in a 3 or optional 4 wire system. Single or Duplex. Precision wire-wound platinum detector Accuracy to IEC 751 class B standard Optional class A, 1/3DIN or 1/10DIN. Designed to measure temperatures in industrial environments such as storage rooms and freezers. Temperature range: -50 C to 120 C Ingress protection IP65 Perforated 15mm Coated aluminium wallmounted connectionbox with cable gland. Can be delivered with head mounted transmitter. Type RV 2095 BE 2084 Clamp resistance Surface block Pt100 probe for clamp mounting on tubes. 250 C Accuracy to DIN IEC 60751 class B. Optional accuracy class A Single or duplex sensor. Surface contact area 8mm x 30mm. Nickel plated brass contact block with adjustable stainless steel clamp, permanently attached. Clamp diameter to specify. Cable: Armoured PTFE insulated wires, glassfibre jacket with stainless steel overall braiding for mechanical protection. Maximum cable temperature 240 C. Type BE 2084 RV 2096 Outdoor wall mounting resistance Wall mounted Pt100 sensor for outdoor temperature measurement. Special canopy cap protects influence by direct sunlight. Pt100 sensor connected in a 2, 3 or 4 wire system. Precision wire-wound platinum detector. Single or duplex. Accuracy to IEC 751 class B standard Optional class A, 1/3DIN or 1/10DIN. Designed to measure temperatures in industrial environments. Weather proof IP65. Temperature range: -50 C to 120 C Perforated 15mm Coated aluminium wallmounted connectionbox with cable gland. Can be delivered with head mounted transmitter. Type RV 2096

RV 2097 Indoor resistance Wall mounted Pt100 sensor for measuring air temperatures indoor. Representative wall box. Precision wire-wound platinum detector. Pt100 sensor connected in a 3 or optional 4 wire system. Single or duplex. Accuracy to IEC 751 class B standard Optional class A, 1/3DIN or 1/10DIN. Temperature range: -10 C to 50 C Optional 4-20mA two-wire transmitter. Type RV 2097 RV 2098 Wall mounted transmitter Wall mounted Pt100 sensor for measuring air temperatures indoor. Representative wall box. Precision wire-wound platinum detector. Pt100 sensor connected in a 3 or optional 4 wire system. Single or duplex. Accuracy to IEC 751 class B standard Optional class A, 1/3DIN or 1/10DIN. Temperature range: -10 C to 50 C Including 4-20mA two-wire transmitter. Type RV 2098 Industrial Temperature Assemblies with Temperature Transmitters Thermo-Electra offers complete temperature assemblies, consisting of a thermocouple or Pt100 RTD sensor, temperature transmitter hockey puck or with integrated display and thermowell for oil and gas production, as well as petrochemical, power generation and process industries. Our sensors and high pressure resistant thermowells in combination with the Yokogawa YTA50 / YTA70 and YTA110 / YTA310 / YTA320 temperature transmitter are used worldwide in several projects. Hazardous certification for the combination is available. Thermo-Electra industrial temperature sensors can also be combined with the transmitter brand you have standardized. Type IECEx-ATEX Type MITx

Powered by TCPDF (www.tcpdf.org) Industrial Pt100 RTD's Cladding, coating and sleeves Corrosion resistant sleeves: Thermowell sleeve from Tantalum ( Tantalium ) or Titanium fit over a standard stainless steel thermowell and provides an economical way to protect against corrosion of highly corrosive chemical solutions and agents. Corrosion resistant coating: PTFE/PFA/PVDF Teflon /Kynar or Halar coating give very good corrosive resistance to almost all chemicals. Very good heat resistant and also has cryogenic stability. Used for Food and Beverage, Pharmaceutical, Acid, Caustic and Electroplating applications. Abrasion resistant overlay: Deloro Stellite or Eutalloy as an welded overlay result in an excellent wear resistant thermowell. Type Option