Safe and secure distribution of medium voltage with AX1



Similar documents
The Intelligent AX1 Switchgear for Medium Voltage

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

UFES Active protection for switchgear

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Medium voltage arc flash eliminator units VAM 3ED,

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Secondary Unit Substations

Advantages of Fixed Circuit Breaker Switchgear

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Metal-enclosed single busbar, Solid and Air-Insulated switchgear

30 ms High Speed Transfer System (HSTS) Product Description

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Medium voltage indoor circuit breakers ANSI/IEC solutions

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Unified requirements for systems with voltages above 1 kv up to 15 kv

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

P System Cubicles. Certified for more safety

Metal-enclosed single busbar, Solid and Air-Insulated switchgear

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

MNS is Switchgear System Technical Overview

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Respecting the environment

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

IEC in ZX Gas-insulated medium voltage switchgear

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

Remote Monitoring and REC 501 Control Unit Product Guide

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Safe and reliable distribution network ABB portfolio for medium-voltage indoor applications

MEDIUM VOLTAGE SWITCHGEAR. DI-2, a modular concept combining all mediumvoltage

FAQs-Main switchboard design criteria

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Power-Zone 4 Arc Resistant Low Voltage Switchgear

What will MV switchgear look like in the future? by Jean-Marc Biasse

Nothing s BetterThan the Original MODAN Power Distribution Systems

Relion. Power system protection and automation reference Fast substation busbar protection with IEC and GOOSE

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

MEDIUM VOLTAGE SWITCHGEAR CATALOGUE. Code: P2490_xx

21 st Century Facilities

8. Switchgear and switchgear installations for high voltage up to and including 52 kv (medium voltage)

Advantages of a Company Switch vs. a Safety Switch Receptacle Combination:

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Engineering Specification

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Gas-insulated switchgear type series 8DN8. up to 170 kv, 63 ka, 4000 A. Answers for energy.

INDOOR MEDIUM VOLTAGE SWITCHGEAR UP TO 24kV

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

VD4. Vacuum circuit-breaker

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Low Voltage Products. Switches Automatic Transfer Switches

SIVACON The Versatile Low-Voltage Switchboard

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Comparative study for cables and busbars

Low Voltage Switchboards The Best Technical Solution for Your Ship

INDOOR MEDIUM VOLTAGE SWITCHGEAR - UP TO 24kV. A division of ACTOM Pty Ltd

The Application of Circuit Breakers to Reduce Downtime in Datacentres

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Houston Service Center Medium Voltage Service and Aftermarket Solutions

know-how Giant in distributing electricity for industry Prisma GK

Disconnectors and Earthing Switches 36 kv up to 800 kv

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

GE Power Controls. MiniFORM Switchboards

SIVACON Low Voltage Switchboard

Permissible ambient temperature Operation Storage, transport

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Welcome IEEE Members and Guests Jan 20, 2014

Medium Voltage Switchgear

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING. May 2014 BACKGROUND

Model 1756 Test Lead Kit

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

The power distribution board that sets new standards

Transformers. Special transformers Reactors products

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Bypass transfer switch mechanisms

Medium Voltage Distribution FLUVAC. Vacuum Circuit Breaker Up to 24 kv 630 A 21 ka. Operation Maintenance Instructions.

Transcription:

Safe and secure distribution of medium voltage with AX1

The intelligent switchgear AX1 is a modern, air-insulated switchgear that lies at the very front line of safety and security safety for operating personnel and security for reliable distribution. The reason behind this is simple. Intelligent, built-in functions for tripping, interlocking, alarms, operational information, maintenance needs and arc protection. This intelligence is found in the panel computers. There s one included in every AX1 panel and each is served by a range of sensors that gather a variety of useful information. The panel computers process this information and then decide what measures need to be taken. Furthermore, this monitoring is continuous. When AX1 switchgear is up and running, it takes care of its operation all by itself. AX1 also offers many other benefits, not the least of which is an active arc protector that eliminates an internal arc within 5 ms. The arc is short-circuited to earth and the fault current is then interrupted in the normal way. with minimal maintenance needs Thanks to its continuous monitoring, AX1 has no need for traditional periodic maintenance. Instead, the panel computers keep a watchful eye on the status of the switchgear and warn in plenty of time if inspection or service is required. But as AX1 is essentially maintenancefree, such service hardly ever needed. 2

Entirely without bolts, coil spring contacts in the tubular busbars simplify fi tting and eliminate the need for subsequent tightening. Easy programming of the panel computers with the help of a PC. and maximum cost-efficiency The low maintenance requirement naturally contributes to cutting the overall life-time costs for AX1 switchgear. But AX1 can also offer further cost-saving benefits: The compact main-circuit enclosure saves space. Thanks to the arc eliminator, costs for a pressure relief system are avoided and the choice of switchgear location is widened. The auxiliary power system and cross-connection are If we look ahead, even far built into the switchgear s support panel. into the future, we will also The tubular busbars with their unique coil spring discover that AX1 is well-prepared contacts simplify installation. for profitable decommissioning. All AX1 panels are fully function-tested prior to Recyclable materials have been delivery and thus easy to bring into operation. used throughout its construction. 3

AX1 for power industries 4

Personal safety No one should be exposed to unnecessary risks when carrying out their work. AX1 has thus been designed to effectively minimise all risks. Complete personal safety in a switch gear can only be achieved if all live primary circuits are shielded from accidental personal contact. An additional requirement is that arcing is taken care of in such a way that a person at or close to the switchgear is not injured. Protection against accidental contact in AX1 is achieved by placing all primary circuits in the panel s main circuit enclosure. Furthermore, the power cable connections are single-phase encapsulated with an earthed outer layer for additional personal safety. For active personal protection against an open arc, AX1 features an extremely fast arc eliminator. If an open arc occurs within the switchgear, all three phases are earthed so quickly that a dangerous pressure increase doesn t have time to build up and hot and poisonous arc gases don t have time to form. In other words, a switchgear room with an AX1 swithgear is a safe place of work. All medium voltage is located in the separate main-circuit enclosure, shielded from accidental contact and protected from the environment and other external infl uences. and complete monitoring Many forward-thinking operational managers must have dreamt about switchgear that takes care of itself. Today, their dreams have become reality. AX1 switchgear is fully supervised by its own panel computers so no periodic inspection is ever needed. Operational reliability increases at the same time as maintenance costs decrease. That s the way all modern switchgears should perform. The operating mechanisms are located at the front of the panel, completely shielded from the main circuits by an earthed steel wall. Power cable connections with singlephase encapsulation and an earthed outer layer ensure personal safety. 5

AX1 for processing industries 6

Reliable operation Switchgear has an important task in a production process. It is to ensure that a supply of electricity is always available. AX1 employs modern technological solutions in its primary function, distributing medium voltage, as well as in all its operating and supervisory functions. The circuit-breaker is available in both SF6 and vacuum designs, each of which features the very latest technology. The operating mechanism is easy to access behind the front panel and can be replaced during operation. The panel computers constantly check that everything is working as it should. If something unexpected does occur, they alert operating personnel in good time for appropriate measures to be taken. An additional reason for the high availability of AX1 is its unique arc eli minator. If an arc should occur inside an AX1 panel, it is earthed so quickly that thermal or mechanical damage has no time to arise. AX1 switchgear can thus be brought back into operation again immediately following an arc fault as long as the fault that caused the arc is remedied. The modern current sensor technology of the Rogowski coil makes it possible to measure all currents that the circuit-breaker has broken. Based on these values, the panel computer can calculate the circuit-breakers contact wear. The Rogowski coils in AX1 are integrated in the cable connection devices, which also contain capacitive voltage dividers for measuring voltage. gives profitable production AX1 means a secure supply of electricity. Its need for only minimum maintenance saves costs. Put the two together and you have a solid foundation for profitable production. By communicating with the panel computers, operating personnel can quickly gather the information they need to judge the status of the switchgear. The arc eliminator has three very fast earthing switches integrated one per phase in the busbar support insulators. 7

AX1 for the oil & gas industries 8

For small spaces An oilrig only has a limited amount of space. That s why AX1 offers the ideal solution. Its tubular busbar design has made it possible to shrink panel dimensions dramatically and AX1 now boasts the market s smallest size compared with other switchgears of equivalent rated data. Its small size means that AX1 can be integrated into a 24 ft standard container without problem. Apart from saving space, this also simplifies installation since the switchgear is fully-assembled in the container on delivery. The only on-site activity remaining is to connect the power cables. in harsh environments To ensure trouble-free operation in even the toughest conditions, AX1 is rigorously tested and in compliance with IEC and UL demands. In addition, complete panels of AX1 have been tested and approved according to DNV s requirements. Compact design makes AX1 the market s smallest switchgear in its class. AX1 switchgear fi tted in a 24 ft standard container. 9

10 AX1 for contractors

Simple assembly Several aspects of AX1 switchgear contribute to its simple assembly. Its modular construction means that the lower frame is a completely separate part that can be fitted in place in advance. Fitting the cable end connections can thus be completed while enjoying the best possible access before the rest of the switchgear is installed. The tubular busbars with their unique coil spring contacts simplify joining the panels to one another. All internal wiring in the panels is already in place at delivery and is joined together with snap connections during on-site installation. Cross-connecting takes place in the switchgear s support panel, where all external wiring for communication with the switchgear is connected. The auxiliary power system can also be located in the support panel, a simple and space-saving solution. Naturally, the complete switchgear is function-tested at the factory prior to delivery to facilitate bringing it into operation. Coil spring contacts simplify connecting busbars between panels. without the need for pressure relief The active arc protection of AX1 means that dangerous pressure increases never have a chance to build up and that harmful arc gasses cannot arise should an internal open arc occur within the switchgear. This eliminates the need for a pressure relief system, which both saves space and simplifies the location and installation of the switchgear. By placing the panel s lower frame in position in advance, the cable end connections can be completed quickly and simply before the rest of the switchgear is installed. Support panel with cross connections and auxiliary power system. 11

AX1 has been developed with full respect for the environment. Recyclable material has been used throughout and its design minimises the total operating losses over the switchgear s life-time. Comparative Life Cycle Assessments (LCA) show that the total environmental load of AX1 is approximately 50% of that of equivalent switchgears with a conventional construction. Height Depth Width 2 040 / 2 240 mm with lower frame 600 / 800 mm 1 050 mm 650 / 975 mm Technical data Rated voltage 12 kv 24 kv Rated current 630-3150 A 630-3150 A Short-time current 16-40kA or 50*, 3 s 16-40kA or 50*, 3 s Open arc test 16-40 ka or 50*, 1s 16-40kA or 50*, 1 s Dimensions Certain functions described in the text and certain illustrations of the AX1 panels are not part of the standard confi guration. We retain the right to make changes in the design, dimensions and technical data without prior notice. 1VET 954 301-901 ReklamCenter 01113 Printed in Sweden, Edita Västra Aros ABB Power Technology Products Medium Voltage Products SE-771 80 Ludvika, Sweden Tel: +46 240 78 20 00 Fax: +46 240 78 40 21 Internet: www.abb.com/mediumvoltage