M850-W-x and M850-P-x Flow Computers

Similar documents
Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Quick Connect. quick - simple - efficient.

Electronic Control Devices The European Product Catalogue 2007

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Application/Connection Examples

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Safety technique. Emergency stop module BO 5988 safemaster

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

How To Use A Ds340 (Dsp)

Preset Counter signo 721

Contents. Document information

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

IMR 6000/10../20../30

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Rack mounted telephone- and leased line modem for industrial applications

Electronic Control Devices The European Product Catalogue 2007

ZC-24DO CANopen I/O Module: 24 Digital Outputs

PCS0100en Persy Control Services B.V. Netherlands

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Analog signal converters CC-E I/I Current / current isolators

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Multifunction devices

Modular I/O System Analog and Digital Interface Modules

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

T0118 T2118 T3118. Instruction Manual

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Duct Humidity Transmitter

NC-12 Modbus Application

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Wahl C50 Calibrator FEATURES

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

KNX Panasonic Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

IntesisBox KNX Modbus TCP master

Three-phase monitoring relay CM-PFE

Model: DC-A2IO Advanced HVAC Controller

IntesisBox Modbus Server Fidelio IP

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

Thyristor-controlled power supplies and battery chargers

Rosemount 333 HART Tri-Loop

TrueAlarm Fire Alarm Systems

J TB/TW Temperature limiter, temperature monitor

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

OZS Web server. For LPB/BSB plants

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Telephone- and leased line modem for industrial applications TD-36

NEW. EVEN MORE data acquisition and test stand automation

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

PD 100A. Printing data system

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

WEB log. Device connection plans

ACS-30-EU-EMDR-10-MOD

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

3500/93 System Display

1 Serial RS232 to Ethernet Adapter Installation Guide

MLC TM Maximum Productivity and Versatility for Control without Compromise!

COMPALARM AP GENERAL MAIN FEATURES

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

AIS750 Series Alarm Annunciator

38 Series - Relay interface modules A

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Temperature & Humidity SMS Alert Controller

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Differential Charge Amplifier

WEB log. Device connection plans

Power Supplies 3. SDN-P DIN Rail Series

Rosemount 333 HART Tri-Loop

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

HCR3.2/.. Chipcard reader HOTEL SOLUTION

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Digital input modules

Digital Pressure Measuring Instrument MDR480

FX07 Field Controller

FX07 Field Controller

3500/22M Transient Data Interface

TMS TANK MANAGEMENT SYSTEM

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Transcription:

ALARM ALARM Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice. Copyright 2016 TI-P333-29 MI Issue 3 M850-W-x and M850-P-x Flow Computers Description The M850 is a flexible and easy to use flow computer that accurately calculates mass and energy flow for steam, gas and liquids across a wide variety of applications. Standards These products fully comply with the requirements of the European Directives and carry the mark when so required. M850-W-x The M850 is available with the following certification: - Uncertainty Certificate / Inspection Report. Note: All certification / inspection requirements must be stated at the time of order placement. M850-P-x REC USB 1 2 3 4 5 6 7 8 9 10 REC USB M850 1 2 3 4 5 6 7 8 9 10 M850 Available options Both versions of the M850 series have the same functions and are available as follows: M850-P M850-W for panel mounting and is powered by 24 Vdc. for wall mounting and has been adapted to be powered by 100 / 240 Vac. Additionally, each version can be optionally equipped with one or two analog outputs 4-20 ma. Offered versions of the instruments: M850 -x -P Panel mounted version. -W Wall mounted version. -0 Option without analog 4-20 ma output. -1 Option with one analog 4-20 ma output. -2 Option with two analog 4-20 ma outputs. Page 1 of 6

Technical data for the M850 series flow computers User interface, front panel Display type Display size / resolution LED indication Keyboard Inputs organisation LCD TFT color, 3.5", with LED backlight 43.8 mm x 77.4 mm / 272 (RGB) x 480 px, 3 two-color LEDs, red / green: ALARM, REC, USB 19 membrane buttons 6 x I type (0 / 4-20 ma): IN1, IN2, IN3, IN4, IN5, IN6 Number of inputs 3 x RTD (4-wire): IN7, IN8, IN9 3 x PULS: IN10, IN11, IN12 I type (0 / 4-20 ma current loop analog inputs) Signal type Transmitter connection Input resistance Transmitters supply A / C converter resolution 0-20 ma or 4-20 ma 2-wire passive transmitter (supplied from M850) or active transmitter (current source transmitter) 95 W ±10% (protected with PTC 50 ma fuse in series) 24 Vdc +10% / -20%; max 22 ma per channel (protected with PTC 50 ma fuse and 100 Ω resistor in series) 18 bit (24 bit Sigma-Delta ADC) 50 Hz / 60 Hz filter Sinc3 digital filter Damping (1 st order Low Pass Software Filter time constant) Measurement resolution Accuracy (at T amb = +25 C / +77 F) 2 s / 5 s / 10 s / 20 s / 30 s / 1 min / 2 min / 3 min / 5 min > 0.01% of FS ± 0.1% of FS (typical W0.05% of FS) Temperature drift Maximum ± 0.02% of FS / C Maximum input voltage Galvanic isolation between inputs ± 40 Vdc No; common potential of functional GND for all inputs Galvanic isolation to Analog Outputs, RS-485 / RS-422, Ethernet 250 Vac continuous; 1500 Vac for 1 minute RTD type (3 analog inputs for temperature sensors) Sensor types Measuring range Sensor connection Wire resistance compensation Maximum resistance of connecting wires A / C converter resolution Pt-100 x K; Ni-100 x K; where K = 1..11 (K multiplier, e.g.: K = 2 for Pt-200) -200.. +850 C / -328.. +1562 F for Pt100 x K -60.. +150 C / -76.. +302 F for Ni100 x K 4-wire (2-wire with wire bridges) Automatic, additional manual in range -99.99.. +99.99 50 18 bit (24 bit Sigma-Delta ADC) 50 Hz / 60 Hz filter Sinc3 digital filter Damping (1 st order Low Pass Filter time constant) Measurement resolution Accuracy (at T amb = +25 C / +77 F) 2 s / 5 s / 10 s / 20 s / 30 s / 1 min / 2 min / 3 min / 5min > 0.05% of reading or 0.1 Ω (TBV) ± 0.5 C / ± 0.9 F (typical ± 0.3 C / ± 0.54 F) Temperature drift Maximum ± 0.02 C / C / 0.036 F / F Max input voltage Galvanic isolation between inputs Galvanic isolation to Analog Outputs, RS-485 / RS-422, Ethernet ± 40 Vdc No; common potential of functional GND for all inputs 250 Vac continuous; 1 500 Vac for 1 minute Page 2 of 6

PULS type inputs (binary / pulse / frequency) Measuring range Minimum pulse width 0.. 20 khz (cut off for f < 0.001 Hz) (0..1 khz with filter jumper J1 / J2 / J3 ON) 25 μs (0.5 ms with filter jumper J1 / J2 / J3 ON) Accuracy for frequency measurement (at T amb = +25 C / +77 F) 0.02% Maximum input voltage Galvanic isolation between inputs Galvanic isolation to Analog Outputs, RS-485 / RS-422, Ethernet Configuration (default): OC or Contact open / closed Open circuit voltage Short circuit current On / off threshold Configuration: Voltage Input Signal amplitude On / off threshold ± 40 Vdc No; common potential of functional GND for all inputs 250 Vac continuous; 1 500 Vac for 1 minute (Internal jumper J4 / J5 / J6 ON) 5 Vdc 5 ma 2.7 V / 2.4 V (Internal jumper J4 / J5 / J6 OFF) 4.. 36 Vdc 2.7 V / 2.4 V Input resistance Calculation update rate 10 k Compensated flow and heat energy measurement 1 s Total accuracy of compensated steam, water, other liquid or technical gas flow measurement Typical: better then ± 0.5% (worst case: better then ± 2%) 4-20 ma analog output (optional) Number of outputs 1 or 2 Output signal Resolution Loop resistance (R L ) range for U CC = 24 V 4-20 ma passive (external current loop supply required) 16 bit DAC 0.. 600 Ω Minimum loop power supply voltage U CCmin = RL x 0.022 + 8 Maximum loop power supply voltage Accuracy (at T amb = +25 C / +77 F) 28 Vdc Better than ± 0.2% of FS / C Temperature drift Maximum ± 0.02% of FS / C Galvanic isolation to Analog Inputs, RS-485 / RS-422, Ethernet 250 Vac continuous; 1 500 Vac for 1 minute Binary outputs (M850-W-x) Number of outputs 4 Type of outputs Contact rating (resistive load) Maximum switching voltage Maximum switching power Binary outputs (M850-P-x) 3 pole (COM, NO, NC) electromechanical relay 3 A at 85.. 250 Vac / 30 Vdc 250 Vac / 125 Vdc 750 VA / 90 W Number of outputs 4 Type of outputs Contact rating (resistive load) Maximum ON resistance Galvanic isolation (optoisolation) 2 pole Solid State Relay 0.1 A at 24 Vac/dc (max 42 Vac or 60 Vdc) 20 Ω 250 VAC continuous; 1 500 Vac for 1 minute Page 3 of 6

RS-485 / RS-422 Transmission protocol ASCII, Modbus RTU, BACnet MSTP, GSM Number of nodes in network 256 Maximum line length Baud rate Parity control Frame Internal terminating resistor Maximum bus terminal voltages 1 200 m (depends on quality of data cable and baud rate) 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, 115.2, 230.4 kbps Even, Odd, None 1 start bit, 8 data bits, parity 1 bit, 1 stop bit Yes, activated with DIP switch -8 V +13 V Minimal driver differential output voltage 1.5 V (for R L = 54 ) Minimum receiver sensitivity Short-circuit / thermal protection 200 mv Yes Galvanic isolation to Analog Inputs, Analog Outputs, Ethernet Ethernet port 250 Vac continuous; 1 500 Vac for 1 minute Transmission protocol Interface Data buffer Modbus TCP, ICMP (ping), DHCP server, http server, BACnet IP 10 BaseT Ethernet 300 B Number of opened connections (simultaneously) 4 Connection type LED indication Socket type USB port RJ-45 2 (build in RJ-45 socket) A type, according to USB standard Version USB 2.0 Recording format Rated supply voltage Supply voltage range Power consumption Rated supply voltage Supply voltage range Power consumption Wire connection / terminals Conductor cross Section Cable glands FAT16 (within a limited scope) Power supply (M850-W-x) 100-240 Vac; 50 / 60 Hz 85.. 264 Vac; 47.. 63 Hz Maximum 20 VA Power supply (M850-P-x) 24 Vdc 18.. 36 Vdc Wire terminals (M850-W-x) Maximum 8 W, device SELV and limited energy Spring type terminal block Solid 0.2.. 2.5 mm 2 Stranded 0.2.. 1.5 mm 2 Stranded with ferrule 0.25.. 1.5 mm 2 AWG 26.. 12 4 glands type M20, 2 glands type M16 Page 4 of 6

Wire terminals (M850-P-x) Wire connection / terminals Conductor cross Section Screw type terminal blocks, plug type Solid 1.5 mm 2 max Stranded 1 mm 2 max Stranded with ferrule 0.25.. 1.5 mm 2 AWG 30 / 14 Enclosure (M850-W-x) Enclosure type Dimensions (height x width x depth) Weight net (gross) Protection class Enclosure type Dimensions (height x width x depth) Panel cut-out dimensions Panel thickness Weight net (gross) Protection class (front / rear) Ambient temperature Relative humidity Altitude Storage temperature Overvoltage category Pollution degree Wall mounting, Polycarbonate material 216 mm x 260 mm x 125 mm (without cable glands) 246 mm x 260 mm x 125 mm (with cable glands) 290 mm x 300 mm x 165 mm (in cardboard box) approx. 1.7 kg (2.1 kg) IP65 Enclosure (M850-P-x) Panel mounting, Lexan Resin 920 material 96 mm x 192 mm x 63.5 mm (without terminals) 96 mm x 192 mm x 72 mm (with terminals) 135 mm x 230 mm x 110 mm (in cardboard box) 186 mm x 92 mm 1.. 5 mm approx. 0.6 kg (0.7 kg) IP65 / IP20 Environmental conditions 0.. +55 C (32.. 131 F) 5.. 95% (non-condensing) 2000 m (6 562 ft) above sea level -30.. +70 C III 3 Panel version (when installed in an enclosure) 3 Wall version LVD (safety) Electrical safety EN 61010-1 EMC Installation location Immunity EN 61326-1 Table 2 Radiated and conducted emissions EN 55011 and EN 55022 to Class B Indoor use only Page 5 of 6

Dimensions / weights (approximate) in mm and kg M850 A B C D E Weight Wall mounted 257 217 134 30 * - 1.70 Panel mounted 206 110 72.3-9.5 0.60 * Approximate dimension as the cable glands are adjustable. M850-W-x (wall mounted) A C M850-P-x (panel mounted) A C B M850 B E D Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions supplied with the product. Installation notes: 1. The wall mounted M850-W-x requires 3 mounting screws (not supplied) to mount to a wall or optionally has a DIN rail mounting. 2. The panel mounted M850-P-x is supplied with mounting clamps. 3. An adaptor plate is available as a separate kit, should the M850 be replacing an existing M200 or M800 flow computer. Disposal This product is recyclable. No ecological hazard is anticipated with the disposal of this product, provided due care is taken. How to order For the correct product nomenclature for the unit that best suits the intended application please revisit page 1 'Available options' before placing an order. Example: 1 off M850-W-1 wall mounted flow computer with one analog 4-20 ma output, 240 Vac supply. Spare parts There are no spare parts available for the M850 flow computers. Available accessories - Panel mounting adaptor plate. Page 6 of 6