A Comparison of Smart Shading Control Strategies for Better Building Energy Performance

Similar documents
Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Software Development for Cooling Load Estimation by CLTD Method

SELECTIVE GLAZING FOR SUN CONTROL

Energy Efficient Hospital Patient Room Design: Effect of Room Shape on Windowto-Wall Ratio in a Desert Climate

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

ResearcH JournaL 2009 / VOL

Parametric Analysis of School Classroom Typologies' Energy Performance

Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

Adaptive strategies for office spaces in the UK climate

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Energy Efficient HVAC-system and Building Design

SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION.

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

The Importance of Building Criteria on Cooling Energy Demand of a Low Cost Residential House: Thailand Case Study

The Sino-Italy Environment & Energy Building (SIEEB): A model for a new generation of sustainable buildings

The Influence Of Window Type And Orientation On Energy-Saving In Buildings Application To A Single Family Dwelling

CHAPTER 3 Window design for day lighting, ventilation and to

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

3-D Modeller Rendered Visualisations

Selecting Energy Efficient Replacement Windows in Nevada

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

Selecting Energy Efficient New Windows in Texas

Selecting Energy Efficient New Windows in Georgia

Selecting Energy Efficient New Windows in Florida

Selecting Energy Efficient New Windows in Arizona

Energy savings in the residential area are essential in

Models and Methods in Applied Sciences

The Influence of Insulation Styles on the Air Conditioning Load of Japanese Multi- Family Residences

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

Selecting Energy Efficient New Windows in California

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Energy Efficiency in Buildings

Solar Energy Utilisation in Buildings

Thermal performance optimization of building aspect ratio and south window size in ve cities having di erent climatic characteristics of Turkey

Building Energy Modelling. prescriptive

薄 膜 對 提 高 樓 宇 窗 戶 性 能 的 研 究 分 析

Passive Solar Design and Concepts

Building Information Modelling (BIM); How it Improves Building Performance. R.P. Kumanayake Lecturer, Department of Civil Engineering

Assessing the Effects of Glazing Type on Optimum Dimension of Windows in Office Buildings

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

Ecofys VII U-Values for Better Energy Performance of Buildings

Energy Savings with Window Retrofits

Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving

Efficient use of energy simulation in the early design phase

Protocol for the Certification of Energy Simulation Software: Second edition, September 2011

Klosterenga, Oslo, Norway, page - 1

Net Zero Station Design for The Cooper Centre for the Environmental Learning in Tucson, Arizona: Improving the performance of existing buildings

Scenario analysis of Carbon Trade for Energy Efficient Renovations of. Operation Manual (take Beijing as an example)

Studies energy efficiency of the renewable sources use considering climate in Latvia

Decision-making Methodology & Selection Tools for High-performance Window Systems in U.S. Climates Kerry L. Haglund 1

ENERGY AUDIT. Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM):

Energy efficient home design

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE

Thermal comfort and Energy Efficiency in

Solar Heating Basics Page 1. a lot on the shape, colour, and texture of the surrounding

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

RosevilleProject. LoE _ 2 Glass Products. You can reduce your cooling energy usage by 25% or more. Here is the proof.

Marko G. IGNJATOVIĆ *, Bratislav D. BLAGOJEVIĆ, Branislav V. STOJANOVIĆ, and Mladen M. STOJILJKOVIĆ

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Residential HVAC System Sizing

Energy-Plus Primary School, Hohen Neuendorf, Germany

The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows

Case Study Family Room Renovation 3br family home, Melbourne

Protocol for the Certification of Energy Simulation Software: First edition, December 2009

Energy Efficiency HOSPITALITY.

Improving thermal insulation of concrete sandwich panel buildings

Infrared Moisture Detection

Low energy class 1 typehouses according to the Danish building regulations

ENERGY AUDITS IN DWELLING BUILDINGS IN LATVIA. DATA ANALYSIS

HEATING-COOLING WALL PANELS SYSTEM IN SLOVENE ETHNOGRAPHIC MUSEUM

Passive house rehabilitation of post war residential building in Zug, Switzerland

ANALYSIS OF INDOOR PERFORMANCE OF HOUSES USING RAMMED EARTH WALLS. Veronica Soebarto The University of Adelaide, Adelaide, Australia

The Reunion experience

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

An Approach to Low-Energy Architecture for Commercial Buildings in Vietnam

Case Study 13 Schools of Architecture and Design, Wellington tertiary education institute, New Zealand

White Paper Nest Learning Thermostat Efficiency Simulation for France. Nest Labs September 2014

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

Green BIM/ Early BIM/

CHAPTER 3. The sun and the seasons. Locating the position of the sun

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

CO2 Emissions. Indirect CO 2. Emissions Electricity and Heat Production 25 % Direct Emissions AFOLU 24 % Energy 1,4% Buildings 6,4 % Industry 11 %

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

Systems Selection Enclosure Systems Material Selection Assessment and Mitigation

Green Architecture and Construction

Energy Related Design Decisions Deserve Simulation Approach

CHAPTER 11: PASSIVE SOLAR HOMES

Holistic Approach in Delivering Government Buildings The Low Carbon Concept

Refurbishment Mas Thibert / Arles

BER Assessors Dwellings Technical Bulletin

Design and Re-Use Of Shovadans In Today's Architecture "With Due Attention To Have Thermal Energy Of The Earth"

Siemens Gebze Location FIRST GREEN BUILDING IN TURKEY CERTIFICIED AS LEED GOLD

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

Transcription:

, pp.107-116 http://dx.doi.org/10.14257/ijsh.2016.10.12.11 A Comparison of Smart Shading Control Strategies for Better Building Energy Performance Jian Yao, Bingjie Wang, RongYue Zheng Faculty of Architectural, Civil Engineering and Environment, Ningbo University, Ningbo, China E-mail: yaojian@nbu.edu.cn Abstract The objective of this research is to investigate the energy performance of different smart solar shading control strategies on typical residential buildings in hot summer and cold winter zone of China. Four typical sensor based automatic shading control strategies were analyzed using building simulation tools to optimize indoor thermal and energy performance. It was found that solar radiation based sensor control has a better energy performance than temperature based sensor control with an energy reduction (both cooling and heating) of about 5-10% depending on the type of control strategy. The results indicate that solar based sensor control on solar shades can be widely used in residential and commercial buildings for an improved energy performance. Keywords: Building energy, sensor, smart control, solar shading 1. Introduction Buildings in China consume approximately 27.5% [1] of national total energy. To reduce building energy consumption, a variety of energy efficiency measures can be adopted such as adding wall insulation materials [2, 3], using energy efficient windows [4], incorporating renewable energy technologies and solar shading devices [5, 6]. Among them, solar shading devices play a critical role in reducing building energy demands and creating a comfortable indoor thermal environment by blocking excessive solar heat gain in summer conditions. Compared to fixed shading devices such as overhang and side fin, movable solar shades are more popular in hot summer and cold winter zone of China since they can fulfill two conflicting aims: maximize winter solar gain, which is desirable as it reduces heating energy demand and, equally, prevent excessive summer solar gain as it is one of the responsible of overheating conditions and cooling energy demand. For movable solar shades, automatic devices are more efficient and contribute to less building energy demands compared to manually controlled ones since they can smart control shades according to the environmental conditions to maintain a comfortable indoor condition by keeping solar shades at a suitable position or angle [7-9]. The emerging technologies improve the performance of automatic solar shades and they can be controlled by the environmental factors such as solar radiation, indoor or outdoor temperature using sensors. To evaluate the energy performance of different smart shading control strategies, a simulation based analysis will be conducted in this paper and four typical sensor based automatic shading control strategies were analyzed using building simulation tools to optimize indoor thermal and energy performance. Finally, the suitable control strategy for building rooms facing different orientations will be commented. ISSN: 1975-4094 IJSH Copyright c 2016 SERSC

2. Methodology 2.1. Typical Residential Building A typical residential building in hot summer and cold winter zone of China was considered in this research and was simulated by the software EnergyPlus, a wholebuilding energy simulation program developed by the U.S. Department of Energy (DOE) [10]. The building is a three-unit, six-story residential building in Ningbo city with 6 housing units (about 85m2 for each unit which has one reading room, one living room and two bedrooms) as shown in Fig.1. The total area of the building is 3168.9 m2 and the height of each floor is 2.8 m. Fig. 2 shows the architectural plan of the west housing unit. The window-to-wall ratios are 0.06 for east and west facades, 0.41 for south façade and 0.28 for north façade. To reflect the impact of control strategies on different orientations, the west bedroom, west living room and west reading room as shown in Fig.2 are considered since only the west housing unit has west-facing windows and the whole housing unit was also simulated to identify which strategy is much better. 2.2. Simulation Setting Figure 1. Typical Residential Building Model The simulation settings complied with the design standard in this climate region [11] and the typical meteorological year data was used in 8760 hours simulation. The external wall of the building was a 240mm-brick wall with 30mm insulation materials and the windows for this building are double-pane glazing (6+9+6 mm). The room temperatures were set between 18-26 oc for the whole year. The total power density of miscellaneous loads (including lighting systems and occupants) was 4.3 W/m2 and the air change rate was 0.5 per hour. The detailed values of these settings are listed in table 1. 108 Copyright c 2016 SERSC

Figure 2. The Architectural Plan of the West Housing Unit Table 1. The Setting of Building Envelope and Air-conditioner etc. Parameter Building envelope Value External wall: U-value= 1.5 W/m 2 K, Orientation: south; Roof: U-value=1.0 W/m 2 K; Window: U-value=3.6W/m 2 K, Solar shading coefficient (SC)=0.84; Air-conditioner Temperature: 18-26 o C for the whole year Miscellaneous loads 4.3W/m 2 Air change rate 0.5 per hour 2.3. Smart Shading Strategies Temperature based or light based sensors for building applications as shown in Fig. 3 are popular and they can be used to control the adjustment of movable solar shades automatically. Thus these sensors based smart solar shading control strategies are considered in this paper. To have a comprehensive comparison, four typical strategies available in local market are considered as shown in table 2. The solar radiation is set to 120W/m2 which is roughly the threshold of direct solar radiation according to our field test, and the outdoor or indoor temperature is set to 26oC since above this value space cooling is required in summer conditions. Copyright c 2016 SERSC 109

Figure 3. An Illustration of Temperature based and Light (solar radiation) based Sensors for Applications in Solar Shades Control Sensor type Solar radiation (SOLAR) Outdoor temperature (OA) Indoor temperature (IA) Solar radiation + indoor temperature (IA + SOLAR) 3. Results and Discussion 3.1. West Bedroom Table 2. Smart Solar Shading Control Strategies Control method Close solar shades when solar radiation arrived on the window surface is higher than 120W/m 2 Close solar shades when outdoor air temperature is higher than 26 o C Close solar shades when indoor air temperature is higher than 26 o C Close solar shades when both solar radiation arrived on the window surface is higher than 120W/m 2 and indoor air temperature is higher than 26 o C Figure 4 shows comparison of solar gains through exterior windows for different control strategies. For the west bedroom, it has the highest window-to-wall ratio on the southern façade and thus has a high solar heat gain throughout the whole year ranging from about 50000 to over 130000Wh/m 2. According to Fig.4, solar sensor based shading control strategy has the lowest solar penetration which is less than half of the other three strategies. The poorest strategy is OA control with the largest solar penetration. In terms of energy performance, Fig.5 gives a comparison of these strategies. It can be seen that SOLAR does not has a significant improvement compared to other strategies as 110 Copyright c 2016 SERSC

shown in Fig.5. It performs similar to IA and IA+SOLAR with a minor cooling reduction compared to IA+SOLAR and a minor heating increase. This is because SOLAR strategy may also block solar radiation that is needed in winter conditions. Thus any strategy (SOLAR, IA, IA+SOLAR) can be adopted in the south-facing bedroom. Figure 4. Comparison of Solar Gains through Exterior Windows for the West Bedroom Figure 5. Comparison of Energy Consumption for the West Living Room Copyright c 2016 SERSC 111

3.2. West Living Room For the west living room, the solar heat gain throughout the whole year is relatively low compared to the bedroom ranging from about 17000 to over 34000Wh/m 2 as shown in Fig.6. It can be seen that solar sensor based shading control strategy also has the lowest solar penetration which is about half of the other three strategies. The poorest strategy is also OA control with the largest solar penetration. This is similar to the west bedroom. The energy performance of different strategies for the west living room is shown in Fig.7. It can be seen that SOLAR not only has a relatively low cooling demand, but it also contributes to the least heating energy demand. Therefore, the best strategy for this room is SOLAR, followed by IA and IA+SOLAR. Figure 6. Comparison of Solar Gains through Exterior Windows for the West Living Room Figure 7. Comparison of Energy Consumption for the West Living Room 112 Copyright c 2016 SERSC

3.3. West Reading Room Figure 8 compares solar gains through exterior windows for the west reading room. It can be seen that the solar heat gain throughout the whole year is higher than the west living room but lower than the west bedroom. It ranges from about 47000 to over 71000Wh/m 2. The cooling energy demand for the four strategies is similar while the heating demand differs largely as shown in Fig.9. SOLAR also has the least heating demand compared to the other three strategies. Meanwhile, it can be found that heating demand is higher than cooling demand and this situation is totally different from the other two rooms. This is due to the location of the reading room and the north-facing window receiving less solar radiation relative to the west bedroom and living room. Therefore, the best strategy for this room is also SOLAR. Figure 8. Comparison of Solar Gains through Exterior Windows for the West Reading Room Figure 9. Comparison of Energy Consumption for the West Living Room Copyright c 2016 SERSC 113

3.4. Total Energy Consumption Figure 10 presents the comparison of energy consumption for the west housing unit. It can be seen that SOLAR has the least total (heating and cooling) energy demand, followed by IA, IA+SOLAR and OA. The energy reductions of SOLAR are 4.8%, 6.2% and 10.6%, respectively, compared to IA, IA+SOLAR and OA. Therefore, it is better to use SOLAR as the control strategy for the whole building. If this strategy is not available, IA would be considered as an alternative. Figure 10. Comparison of Energy Consumption for the West Housing Unit 4. Conclusion This paper investigates the energy performance of different smart solar shading control strategies. Four typical sensor based automatic shading control were analyzed using building simulation tools. It was found that solar radiation based sensor control has a better performance than the temperature based sensor control and this control strategy can be widely used in residential or commercial buildings since its cost (it requires only one sensor for each facade) is lower than temperature sensor based control strategies (they require one sensor for each room). Acknowledgments This work was supported by National Key Technology R&D Program of the Ministry of Science and Technology under Grant 2013BAJ10B06, and the authors would like to thank the K.C.Wong Magna Fund in Ningbo University. References [1] B. Florian, Z. Nan and L. Jiang, Energy Use in Commercial Building in China-- Current Situation and Future Scenarios, Proceedings of ECEEE 2007 summer study conference, La Colle sur Loup, France, (2007) June 1065-1071. [2] J. Yu, C. Z. Yang, L. W. Tian, et al., A study on optimum insulation thicknesses of external walls in hot summer and cold winter zone of China, Applied Energy, vol. 86, no. 11, (2009), pp. 2520-2529. 114 Copyright c 2016 SERSC

[3] D. Y. K. Toguyeni, O. Coulibaly, A. Ouedraogo, et al., Study of the influence of roof insulation involving local materials on cooling loads of houses built of clay and straw, Energy and Buildings, vol. 50, no. 7, (2012), pp. 74-80. [4] M. K. Urbikain, and J. M. Sala, Analysis of different models to estimate energy savings related to windows in residential buildings, Energy and Buildings, vol. 41, no. 6, (2009), pp. 687-695. [5] J. Yao, Energy optimization of building design for different housing units in apartment buildings, Applied Energy, vol. 94, no. 6, (2012), pp. 330-337. [6] J. Yao, An investigation into the impact of movable solar shades on energy, indoor thermal and visual comfort improvements, Building and Environment, vol. 71, no. 1, (2014), pp. 24-32. [7] J. Kim, Y. Park, M. Yeo, et al., An experimental study on the environmental performance of the automated blind in summer, Building and Environment, vol. 44, no. 7, (2009), pp. 1517-27. [8] S. Y. Koo, M. S. Yeo, K. W. Kim, Automated blind control to maximize the benefits of daylight in buildings, Building and Environment, vol. 45, no. 6, (2010), pp. 1508-20. [9] P. Chaiwiwatworakul, S. Chirarattananon, P. Rakkwamsuk, Application of automated blind for daylighting in tropical region, Energy Conversion and Management, vol. 50, no. 12, (2009), pp. 2927-43. [10] D. B. Crawley, L. K. Lawrie, F. C. Winkelmann, et al., EnergyPlus: creating a new-generation building energy simulation program, Energy and Buildings, vol. 33, no. 4, (2001), pp. 319-331. [11] China academy of building science, Design standard for energy efficiency of residential buildings in hot summer and cold winter zone, China Architecture and Building Press, Beijing, (2001). Copyright c 2016 SERSC 115

116 Copyright c 2016 SERSC