MacLean Power Systems

Similar documents
S&C TripSaver Dropout Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Bypass switches. Type B-1 and type B-2. Answers for energy.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Transmission Silicone Insulators Line Post 69 kv to 161 kv

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Distribution Dry Type Transformers

When power interruptions happen.

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Hyperlinks are Inactive

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

Specifications. S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

EHV CONNECTORS EHV TERMINALS ACFS (EHV)... ALUMINUM BOLTED TUBE TO FLAT PAD, SHORT...EHV-7

Customer Substation Manual 08/05/02

71

F-Series Camera Mounting Accessories

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

Linear Luminaire with LED Series EXLUX 6402/2

AMPSEAL* Automotive Plug Connector and Header Assembly

5SV Residual Current Protective Devices

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

IRRIGATION PUMPING Table of Contents - Section 900

Short Circuit Current Calculations

Cable/Conduit Conversion

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

Installation. S&C Loadbuster Disconnect Switches Branch Feeder, Main Feeder, Crossarm, and Station Styles

Current Transformers

S. C. Electric Cooperative s Specification for a Three-Phase, Padmounted URD Transformer (Revised 12/2014)

KNOW YOUR OPTIONS: 230 KV POWER CABLES

5.2. Overview. The better method to install solderless compression connectors on power cable

POLE MOUNT SYSTEM-3 INSTALLATION

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Medium Voltage Terminations, 5 kv 46 kv

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Kuhlman Electric Corporation Volt Instrument Transformers

Section kv Power Cables

EARTHING SYSTEM CALCULATION

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

Secondary Unit Substations

POLE MOUNT SYSTEM EX-3 INSTALLATION

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

08. SEK IDC CONNECTORS

Current Limiting Protector For Systems rated kV and continuous currents through 5000A.

How To Read A Pipe From A Sensor

COAXICON Contacts. RF Coax Connectors. Product Facts

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Color Mark Sensor with Red or Green LED E3S-VS

SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS

This section applies to the design and installation of transformers.

Heavy Duty Safety Switches

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Step Voltage Regulators

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

C ole s quality Open Frame Instrument Rotary Switch provides low

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

SMA Interface Mating Dimensions (Per MIL-STD-348)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

TRAILER WIRING AND COMMUNICATION SYSTEMS Systèmes de Communication et Filage de Remorques Sistemas de Comunicación y Cableado para Caravanas

K17.12 Door closers K17. Doors

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

Evolve LED Area Light

Catalog January. Heavy industrial power applications Motor contactors and starters

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

picomax The Pluggable Connection System

Low Voltage Products. Switches Automatic Transfer Switches

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety

Gulf Cable & Electrical Ind. Co.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Transformer Bushings for GIS

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Waterproof Connectors for Outdoor Use

CITY OF LOS ANGELES CALIFORNIA

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Radial Distribution Test Feeders

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Transcription:

Cutouts Catalog Cutouts Catalog MPS Type XS Fuse Cutouts provide full fault spectrum protection to overhead distribution systems. Whether your application is overhead transformers, capacitors, cables, or lines, our product covers systems rated 4.16 kv through 25 kv. Full fault spectrum protection means that Type XS Cutouts interrupt all faults from the lowest current melting the fuse link, to the maximum rated interrupting current. MPS cutouts protect against a fault on the transformer primary or secondary with line to line or line to ground voltage across the cutout, regardless of the transformers winding connections, and with the capability of handling a full range of transient recovery voltage severity associated with these conditions. All MPS Type XS Cutouts employ single venting down and away design. This is an especially important feature which allows exhaust to be kept out of other phases in overbuilt circuits. The nonexpendable fuse-tube cap construction eliminates the extra expense of replacement. Type XC Fuse Cutouts outdoor distrubution 4.16 kv through 25 kv Type XS Cutouts have been expressly designed for superior mechanical performance. Fusing is simple, even with gloved hands. The fuse tubes are simply inserted into the cutout hinge and easily closed without any need for careful aligning by the operating personnel. This makes installation simple even under extreme angles or adverse weather conditions. Type XS Cutouts can be opened and fuse tubes removed with equal ease. MPS Type XS Fuse Cutouts are assigned single value nominal voltage ratings (not dual, slant, or system voltage class ratings) and can be applied without restriction on all three-phase systems having system maximum operating voltage (line to line) less than or equal to the cutout maximum voltage. Under certain fault conditions, cutouts can be exposed to voltages in excess of system line-to-neutral voltage fault conditions which the cutout should clear with no reliance on backup devices. Type XS Cutouts have been tested at full system line-to-line voltage across a wide spectrum of available fault currents, using transient recovery voltages representative of those seen in service. Type XS Cutout interrupting ratings have been substantiated by testing performed in accordance with IEEE C37.41-2000. Shown on page 2 are asymmetrical and symmetrical interrupting ratings for both three-phase and single-phase applications of Type XS Cutouts. The symmetrical ratings for the overhead pole-top style cutouts are based on an X/R ratio of either 8 or 12, depending on cutout voltage rating and interrupting current rating (as specified by IEEE C37.41-2000), realistic maximum ratios for locations where cutouts are normally applied on a typical distribution feeder. Higher symmetrical interrupting ratings apply at locations where the X/R ratio is lower. The curves in the chart below indicate the symmetrical ratings of Type XS Cutouts at other X/R ratios. The mechanical construction of the Type XS Cutout is rugged and strong. It is designed to withstand the interruption forces of heavy fault currents and the typically forceful closing-in by operating personnel. The upper contact and the hinge are attached to husky steel supports, and the mounting bracket is attached to a strong mounting insert. The fuse tube is held at the upper contact by a self-aligning springloaded detent-type latch. The detent features silver-clad embossed surfaces for built-in wiping action resulting in minimum electrical resistance between the upper contact and the silverclad fuse-tube cap. The silver-clad lower contacts also feature embossed surfaces for built-in wiping action, and are backed up by prestressed stainless steel loading springs for efficient current transfer between the contacts Table of Contents Polymer Cutouts Porcelain Cutouts Mounting Bracket Options Numerical Index MacLean Power Systems MacLean Power Systems Please note that because MacLean Power Systems follows a policy of continuous product improvement, we reserve the right to change specifications and drawings at any time without notice. CU-3 CU-5 CU-7 CU-8

Cutouts and the silver-clad fuse-tube trunnion. These specially designed high pressure upper and lower contacts, featuring builtin wiping action, assure superb current transfer even after the contacts have been exposed to the atmosphere for an extended period of time. Also applicable on 26.4-kV through 34.5-kV systems for protection of single-phase-to-neutral circuits (lines or transformers) only, and grounded-wye connected capacitor banks in solidly-grounded-neutral (multigrounded-neutral) systems. OVERHEAD POLE TOP STYLES Three-Phase and Single-Phase Applications Continuous Current Rating, Amperes 100 200 Style Extra-Heavy-Duty 2 Ultra-Heavy-Duty 3 Ultra-Heavy-Duty 3 Voltage Rating, kv, Nom. 14.4 25 25 14.4 25 25 25 14.4 25 25 kv, Max 15 27 27 15 27 27 27 15 27 27 kv, BIL 110 125 150 110 125 150 150 110 125 150 Leakage Distance to Ground, Minimum, Inches (mm) Catalog Number Porcelain Insulator Composite-Polymer Silicone Insulator System Voltage, kv 8½ (216) 11 (279) 17 (432) 8½ (216) 11 (279) 17 (432) 26 (660) 89021R10 89022R10 89042R10 89031R10 89032R10 89052R10 89053R10 89071R11 89072R11 89092R11 89021R10-P 89042R10-P 89031R10-P 89052R10-P 89053R10-P 89071R11-P 89092R11-P 8½ (216) Short-Circuit Interrupting Rating, Amperes RMS, Asymmetrical 4 and Symmetrical 5 (one-shot rating, where applicable, shown in parentheses) 11 (279) 17 (432) 4.16 thru 14.4 10 000 () 7 100 (8 600) 16 000 10 600 16.5 thru 24.9 10 000 7 100 10 000 7 100 26.4 thru 34.5 26.4 thru 34.5 1 Consult the nearest MPS Sales Office for 50-hertz ratings. 2 Uses nonremovable or removable buttonhead fuse links. 3 Uses removable buttonhead fuse links only. 4 Asymmetrical rating is shown first, in bold-face type. Value in parentheses is associated one-shot rating, based on replacement of cutout tube. Asymmetrical rating is based on total available short-circuit current of the circuit including the dc component, in accordance with IEEE standards. 5 Symmetrical rating is shown second, in light-face type. Value in parentheses is associated one-shot rating, based on replacement of cutout tube. Symmetrical rating is based on available symmetrical short-circuit current at locations where X/R ratio is equal to 8 (for Cutout Catalog Numbers 89021R10, 89071R11, 89072R11, and 89092R11) or 12 (for all other overhead pole-top style cutouts). IEEE C37.41-2000 specifies these X/R ratios, as applicable, depending on cutout voltage rating and interrupting current rating. Cutout offering is, by definition, less connectors and mounting bracket Approximate fuse-tube length, top of fuse-tube cap to bottom of fuse tube: 14¾ inches (375 mm). Approximate fuse-tube length, top of fuse-tube cap to bottom of fuse tube: 18¼ inches (464 mm). Meets 170-kV BIL rating requirement of IEC Publication 282-2. Applicable for protection of single-phase-to-neutral circuits (lines or transformers) only, and grounded-wye connected capacitor banks in solidly-grounded-neutral (multigrounded-neutral) systems where the leakage distance to ground meets user s requirements. Applicable for protection of single-phase-to-neutral circuits (lines or transformers) only, and grounded-wye connected capacitor banks in solidly-grounded-neutral (multigrounded-neutral) systems. CU-3

Polymer Cutouts Polymer Catalog Number 89031R10-P-D Ultra Heavy Duty Overhead-Pole Top Style, rated 15 kv maximum Catalog Number 89052R10-P-D Ultra Heavy Duty Overhead-Pole Top Style, rated 27 kv maximum Features The supports and mounting insert are molded into a high strength, fiberglass reinforced polyester core, which is then molded over with composite polymer silicone insulation. The core has a thicker diameter near the top, center, and bottom for enhanced torsional rigidity. Provides full-fault-spectrum protection to overhead distribution systems rated 4.16kV through 25kV Interrupts all faults...from the lowest current that will melt the fuse link to the maximum rated interrupting current Employs single venting down and away only an especially important feature where exhaust must be kept out of other phases in overbuilt circuits Nonexpendable fuse-tube cap construction eliminates the extra expense of fuse-tube cap replacement Designed for superior mechanical performance Fuse tubes are readily inserted in the cutout hinge and easily closed without any need for careful steering or manipulation on the part of operating personnel XS Cutouts can be opened and fuse tubes removed with equal ease Accessories 100A and 200A Fuse Tubes 300A Disconnect Blade Tube Replacement Fuse Caps Mounting Brackets Catalog Number 89053R10-P-D Ultra Heavy Duty Overhead-Pole Top Style, rated 25 kv maximum Complete XS Cutout with Parallel Groove Connectors kv Rating Nominal Max BIL Cont. Amps, RMS Interupting/ Momentary (Asym.) Approx. Fuse Tube Length Leakage Distance to Ground Fuse Tube/ Disconnect Blade Only 89021R10-P-D 14.4 15 110 100 10,000 11 1/4 8 1/2 89521R10 89031R10-P-D 14.4 15 110 100 16,000 11 1/4 8 1/2 89531R10 89071R10-P-D 14.4 15 110 200 12,000 11 1/4 8 1/2 89571R11 89221R10-P-D 14.4 15 110 300 12,000 11 1/4 8 1/2 89621R10 89042R10-P-D 25 27 150 100 8,000 14 3/4 17 89522R10 89052R10-P-D 25 27 150 100 12,000 14 3/4 17 89532R10 89092R10-P-D 25 27 150 200 10,000 14 3/4 17 89572R11 89222R10-P-D 25 27 150 300 12,000 14 3/4 17 89622R10 89053R10-P-D 25 27 170 100 12,000 18 1/4 26 89533R10 89252R10-P-D 25 27 170 300 12,000 18 1/4 26 89623R10 Cutout Less Fuse Tube Catalog # 89811R10-P 89802R10-P 89823R10-P Notes: 1) Catalog number specifies Parallel Groove connectors as standard. To request eyebolt connectors, replace D with an M in the above catalog numbers. For example: 89021R10-P-M. See Bracket and Connector options for more information. 2) To specifiy mounting bracket, if desired, add suffix letter to catalog number. For example: 89021R10-BD. See Bracket and Connector options for more information. CU-4

Polymer Cutouts Extra Heavy Duty Overhead-Pole Top Style Optional Mounting Bracket (Catalog Number Suffix -B ) 17/32 (13.5) Dia. Hole Optional Parallel- Groove Connector (Catalog Number Suffix -D ) Complete XS Cutout with Parallel Groove Connectors kv Max BIL Cont. Rating Amps, RMS Interupting/ Momentary (Asym.) Approx. Fuse Tube Length Leakage Distance to Ground 89021R10-P-D 15 110 100 10,000 11 1/4 8 1/2 Dimensions in inches (mm) A B C D E Net Weight lbs. (kg) 89031R10-P-D 15 110 100 16,000 11 1/4 8 1/2 8 1/2 12 1/2 6 1/4 9 3/4 20 1/4 2 3/8 89071R10-P-D 15 110 200 12,000 11 1/4 8 1/2 9 1/2 89221R10-P-D 15 110 300 12,000 11 1/4 8 1/2 8 1/2 89042R10-P-D 27 150 100 8,000 14 3/4 17 89052R10-P-D 27 150 100 12,000 14 3/4 17 10 13 1/8 7 7/8 11 3/8 25 1/4 4 1/4 89092R10-P-D 27 150 200 10,000 14 3/4 17 11 89222R10-P-D 27 150 300 12,000 14 3/4 17 10 89053R10-P-D 27 170 100 12,000 18 1/4 26 12 13 3/4 9 1/2 13 31 3/8 6 1/4 89252R10-P-D 27 170 300 12,000 18 1/4 26 12 8 1/2 10 CU-5

Porcelain Cutouts Porcelain* Catalog Number 89021R11-D Ultra Heavy Duty Overhead- Pole Top Style, rated 15 kv maximum Catalog Number 89072R11-D Ultra Heavy Duty Overhead- Pole Top Style, rated 27 kv maximum Features The supports and mounting insert are permanently anchored into cavities in the insulator with inorganic cement, which does not deteriorate with age or absorb moisture. It won t shrink, so the supports and insert won t loosen. Nor does it swell, thus eliminating stress on the cavities. And, the cement retains a slight resiliency to partially absorb the shock of the interruption forces. Provides full-fault-spectrum protection to overhead distribution systems rated 4.16kV through 25kV Interrupts all faults...from the lowest current that will melt the fuse link to the maximum rated interrupting current Employs single venting down and away only an especially important feature where exhaust must be kept out of other phases in overbuilt circuits Nonexpendable fuse-tube cap construction eliminates the extra expense of fuse-tube cap replacement Designed for superior mechanical performance Fuse tubes are readily inserted in the cutout hinge and easily closed without any need for careful steering or manipulation on the part of operating personnel XS Cutouts can be opened and fuse tubes removed with equal ease * Porcelain fuse cutouts are only available from MPS for the US and Canada markets. International customers should contact S&C. Catalog Number 89042R10-M Ultra Heavy Duty Overhead- Pole Top Style, rated 27 kv maximum Catalog Number 89253R10-D Ultra Heavy Duty Overhead- Pole Top Style, rated 27 kv maximum Accessories 100A and 200A Fuse Tubes 300A Disconnect Blade Tube Replacement Fuse Caps Mounting Brackets Complete XS Cutout with Parallel Groove Connectors kv Rating Nominal Max BIL Cont. Amps, RMS Interupting/ Momentary (Asym.) Approx. Fuse Tube Length Leakage Distance to Ground Fuse Tube/ Disconnect Blade Only 89021R10-D 14.4 15 110 100 10,000 11 1/4 8 1/2 89521R10 89031R10-D 14.4 15 110 100 16,000 11 1/4 8 1/2 89531R10 89071R10-D 14.4 15 110 200 12,000 11 1/4 8 1/2 89571R11 89221R10-D 14.4 15 110 300 12,000 11 1/4 8 1/2 89621R10 89022R10-D 25 27 1525 100 8,000 14 3/4 11 89522R10 89032R10-D 25 27 125 100 12,000 14 3/4 11 89532R10 89072R10-D 25 27 125 200 10,000 14 3/4 11 89572R11 89222R10-D 25 27 12 12,000 14 3/4 11 89622R10 89042R10-D 25 27 150 100 8,000 14 3/4 17 89522R10 89052R10-D 25 27 150 100 12,000 14 3/4 17 89532R10 89092R11-D 25 27 150 200 10,000 14 3/4 17 89572R11 89033R10-D 25 27 150 100 12,000 18 1/4 17 89533R10 89223R10-D 25 27 150 300 12,000 18 1/4 17 89623R10 89053R10-D 25 27 150 100 12,000 18 1/4 26 89533R10 89253R10-D 25 27 150 300 12,000 18 1/4 26 89623R10 Cutout Less Fuse Tube Catalog Number 89811R10 89812R10 89802R10 89813R10 89823R10 * Catalog Number specifies Parallel Groove connectors as standard. To request eyebolt connectors, replace D with an M in the above catalog numbers. For example: 89021R10-M. See Bracket and Connector options for more information. ** To specify mounting bracket, if desired, add suffix letter to catalog number. For example: 89021R10-BD. See Bracket and Connector options for more information. CU-6

Porcelain Cutouts Extra Heavy Duty Overhead-Pole Top Style Optional Mounting Bracket (Catalog Number Suffix -B ) 17/32 (13.5) Dia. Hole Optional Parallel- Groove Connector (Catalog Number Suffix -D ) Complete XS Cutout with Parallel Groove Connectors Max BIL Cont. Rating Amps, RMS Interupting/ Momentary (Asym.) Approx. Fuse Tube Length Leakage Distance to Ground 89021R10-D 15 110 100 10,000 11 1/4 8 1/2 Dimensions in inches (mm) A B C D E 89031R10-D 15 110 100 16,000 11 1/4 8 1/2 13 12 1/2 6 1/4 9 3/4 20 1/4 2 3/8 89071R10-D 15 110 200 12,000 11 1/4 8 1/2 14 89221R10-D 15 110 300 12,000 11 1/4 8 1/2 13 89022R10-D 27 1525 100 8,000 14 3/4 11 Net weight lbs. (kg) 89032R10-D 27 125 100 12,000 14 3/4 11 15 1/2 13 1/8 7 7/8 11 3/8 25 1/4 4 1/4 89072R10-D 27 125 200 10,000 14 3/4 11 16 1/2 89222R10-D 27 12 12,000 14 3/4 11 15 1/2 89042R10-D 27 150 100 8,000 14 3/4 17 89052R10-D 27 150 100 12,000 14 3/4 17 13 1/8 7 7/8 11 3/8 25 1/4 4 1/4 20 1/2 89092R11-D 27 150 200 10,000 14 3/4 17 21 1/2 89033R10-D 27 150 100 12,000 18 1/4 17 89223R10-D 27 150 300 12,000 18 1/4 17 13 3/4 9 1/2 13 31 3/8 6 1/4 89053R10-D 27 150 100 12,000 18 1/4 26 23 13 3/4 9 1/2 13 31 3/8 6 1/4 89253R10-D 27 150 300 12,000 18 1/4 26 23 13 15 1/2 20 1/2 CU-7

Mounting Bracket Options Mounting Brackets and Connector Options Item Add Catalog Number Suffix MPS Extended Mounting Bracket, for crossarm, pole, or wall mounting of overhead- pole top style cutouts -B NEMA Type B Mounting Bracket, for crossarm mounting of overhead- pole top style cutouts -C Item Parallel-Groove Conductors Eye-Bolt Connectors Quantity Two One Accommodating Conductors Size and Material No. 6 solid (13.3 mm 2 ) through No. 2 stranded (44.4 mm 2 ) copper or aluminum in one groove; No. 2. solid (33.6 mm 2 ) through 250 kc mil (168 mm 2 ) stranded copper or aluminum or 4/0 ACSR (161 mm 2 ) in the other groove No. 8 solid (8.4 mm 2 ) through 250 kc mil (168 mm 2 ) stranded copper or aluminum, or 4/0 ACSR (161 mm 2 ) Position Standard Orientation -D Lower Connector Rotated 90 -D90 Standard Orientation -M Lower Connector Rotated 90 -M90 Extended Mounting Bracket (Catalog Number Suffix -B ) Adjustable for 3 x 4 to 4 x 5 (76 x 102 to 102 x 127) crossarm When purchased separately- KA-70165-1 NEMA Type Mounting Bracket (Catalog Number Suffix -C ) Adjustable for 3 x 4 to 4 x 5 (76 x 102 to 102 x 127) crossarm When purchased separately- J24712 -M Eyebolt Connector -D parallel groove connector CU-8

Index Catalog Number Description Page 89021R10-D Complete XS Cutout - Porcelain CU-6,7 89021R10-P-D Complete XS Cutout - Polymer CU-4,5 89021R10-P-D Complete XS Cutout - Polymer CU-4,5 89022R10-D Complete XS Cutout - Porcelain CU-6,7 89031R10-D Complete XS Cutout - Porcelain CU-6,7 89031R10-P-D Complete XS Cutout - Polymer CU-4,5 89031R10-P-D Complete XS Cutout - Polymer CU-4,5 89032R10-D Complete XS Cutout - Porcelain CU-6,7 89033R10-D Complete XS Cutout - Porcelain CU-6,7 89042R10-D Complete XS Cutout - Porcelain CU-6,7 89042R10-P-D Complete XS Cutout - Polymer CU-4,5 89042R10-P-D Complete XS Cutout - Polymer CU-4,5 89052R10-D Complete XS Cutout - Porcelain CU-6,7 89052R10-P-D Complete XS Cutout - Polymer CU-4,5 89052R10-P-D Complete XS Cutout - Polymer CU-4,5 89053R10-P-D Complete XS Cutout - Polymer CU-4,5 89053R10-P-D Complete XS Cutout - Polymer CU-4,5 8905R10-D Complete XS Cutout - Porcelain CU-6,7 89071R10-D Complete XS Cutout - Porcelain CU-6,7 89071R10-P-D Complete XS Cutout - Polymer CU-4,5 89071R10-P-D Complete XS Cutout - Polymer CU-4,5 89072R10-D Complete XS Cutout - Porcelain CU-6,7 89092R10-P-D Complete XS Cutout - Polymer CU-4,5 89092R10-P-D Complete XS Cutout - Polymer CU-4,5 89092R11-D Complete XS Cutout - Porcelain CU-6,7 89221R10-D Complete XS Cutout - Porcelain CU-6,7 89221R10-P-D Complete XS Cutout - Polymer CU-4,5 89221R10-P-D Complete XS Cutout - Polymer CU-4,5 89222R10-D Complete XS Cutout - Porcelain CU-6,7 89222R10-P-D Complete XS Cutout - Polymer CU-4,5 89222R10-P-D Complete XS Cutout - Polymer CU-4,5 89223R10-D Complete XS Cutout - Porcelain CU-6,7 89252R10-P-D Complete XS Cutout - Polymer CU-4,5 89252R10-P-D Complete XS Cutout - Polymer CU-4,5 89253R10-D Complete XS Cutout - Porcelain CU-6,7 89521R10 Fuse Tube/ Disconnect Blade Only CU-4 89521R10 Fuse Tube/ Disconnect Blade Only CU-6 89521R11 Fuse Tube/ Disconnect Blade Only CU-4 89522R10 Fuse Tube/ Disconnect Blade Only CU-4 89522R10 Fuse Tube/ Disconnect Blade Only CU-6 89522R11 Fuse Tube/ Disconnect Blade Only CU-4 89531R10 Fuse Tube/ Disconnect Blade Only CU-4 89531R10 Fuse Tube/ Disconnect Blade Only CU-6 89531R10 Fuse Tube/ Disconnect Blade Only CU-6 89531R11 Fuse Tube/ Disconnect Blade Only CU-4 89532R10 Fuse Tube/ Disconnect Blade Only CU-4 89533R10 Fuse Tube/ Disconnect Blade Only CU-4 89571R11 Fuse Tube/ Disconnect Blade Only CU-4 Catalog Number Description Page 89571R11 Fuse Tube/ Disconnect Blade Only CU-6 89571R12 Fuse Tube/ Disconnect Blade Only CU-4 89572R11 Fuse Tube/ Disconnect Blade Only CU-4 89572R11 Fuse Tube/ Disconnect Blade Only CU-6 89621R10 Fuse Tube/ Disconnect Blade Only CU-4 89621R10 Fuse Tube/ Disconnect Blade Only CU-6 89621R11 Fuse Tube/ Disconnect Blade Only CU-4 89622R10 Fuse Tube/ Disconnect Blade Only CU-4 89622R10 Fuse Tube/ Disconnect Blade Only CU-6 89623R10 Fuse Tube/ Disconnect Blade Only CU-4 89802R10-P Cutout Less Fuse Tube Catalog Number CU-4,5 89811R10-P Cutout Less Fuse Tube Catalog Number CU-4,5 89823R10-P Cutout Less Fuse Tube Catalog Number CU-4,5 CU-9