4" and 6" Model RCW* Water Control Valve

Similar documents
Price Book - Section 20 Miscellaneous

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

TECHNICAL DATA. Dry 122a. November 12, 2013

Cost Evaluation of Black Steel Pipe and Galvanized Pipe When Using a Nitrogen Generator

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

BERMAD Fire Protection

PRESSURE REDUCING CONTROL VALVE

BERMAD Fire Protection

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

1805 Series Relief Valves

Inspection and Testing of Water-Based Systems

Fighting Fire in Sprinklered Buildings. Student Guide

Wet System. Technical Manual for Operation, Maintenance, and Troubleshooting

LHD LINEAR HEAT D ETECTIONN

Potter Electric Sprinkler Monitoring Training Manual

Unit 24: Applications of Pneumatics and Hydraulics

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Model 43AP Pneumatic Controller, Style B

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

Pr o d u c t In f o r m at i o n V008.0

Experience In Motion. Valtek Spring Cylinder Linear Actuators

Diameter 3" 4" 6" 8" Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

I-768 FireLock NXT Dry Valve

Transformer Deluge Systems

Wet alarm valves. Wet alarm valves. FM trim

1/29/2008 DR125 / DR150. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PARTS AND PRICES ARE SUBJECT TO CHANGE 1 of 55

Instructions for Installation, Operation, Care and Maintenance

REGULATORS D& HD Series

08.08 Vic-Check Valves

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve

EFSN Training i Module Minutes

American- Darling 5¼" B-84-B-5.

Float and Thermostatic Traps Series H, C and X

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

RUBBER SLEEVE KNIFE GATE VALVE

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

V47 Series Temperature Actuated Modulating Water Valves

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Compressor Service & Maintenance Manual

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

46431x92A Garden Tractor (1998) Page 1 of 16 Body Chassis

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Sprinkler and Fire Alarm Systems for the Building Official

HYDRAULIC LIFT TABLE CART 2200-LB.

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

Boiler Preparation, Start-Up and Shutdown

Isotemp Basic, Slim/B & Slim Square

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

G. VULCANIZED SEAT Pressure sensitive seating with full disc overlap provides positive seating at high and low pressures.

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

How To Control Water Flow

GS-General Service Control Valves

SELECTION, APPLICATION AND MAINTENANCE

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

1/29/2008 DR70. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 43

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Manual piston sampler...m 11

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

HYDRAULIC TABLE CART 500-LB.

1/29/2008 DR50. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 45

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

POWERS Controls No. 4 Pneumatic Damper Actuator

ESFR "PRE-PRIMED SINGLE INTERLOCKED PREACTION" COLD STORAGE SYSTEM MANUAL

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Plastic Injection Molding

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Morrison Bros. Co. General Product Specifications

DR90. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS AND PRICES ARE SUBJECT TO CHANGE 1 of 51

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

James M. Pleasants Company

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

C I T Y O F S E L M A F I R E D E P A R T M E N T

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Transcription:

4" and 6" Model RCW* Water Control Valve for Dry, Preaction, and Deluge Applications Globe Fire Sprinkler Corporation introduces the new Model RCW Water Control Valve for Dry Pipe, Preaction, and Deluge applications. The RCW has been engineered to mitigate many of the fi eld issues historically seen with hydraulically operated differential style valves. One common valve body is utilized for all of the above mentioned system types. The valve and trim options have been engineered with attributes which are most important to both the installer as well as the end user. The valve is offered in groove by groove confi guration. Features 1 Valve 10 Different Trim Configurations Lower Inventory Costs. Lightest The 4 and 6 RCW is lighter than any other manufacturers valve on the market today. The RCW, with each trim confi guration is also lighter than those of any manufacturers versions. Shortest End-to-End Dimension of all Water Control Valves on the market. No Additional Check Valve Required With the RCW Water Control Valve double seat design, an additional check valve is not required for Preaction systems. Ease of Maintenance Understanding the need to properly maintain your NFPA compliant fi re protection system, Globe engineers have designed the RCW valve so that internal inspections, and maintenance, may be performed with minimal effort (i.e. single bolt for clapper seal replacement, easy access to hinge pin with no plugs to remove fi rst, minimal bolts for handhole cover removal). Convenient Color Coded Handles on Trim Valves to Identify Normal Valve Position The trim valve handles are color coded Red or Green to signify whether the valve should be normally closed (red) or normally open (green) for ease of inspection. Patent Pending Low Friction Roller Arm A fi rst of its kind roller arm assembly compresses the diaphragm -to-clapper latching mechanism. This unique latching mechanism provides a robust design, allowing for free movement of the lever arm assembly in the presence of corrosion or debris. Low Friction Loss The patent pending unique design of the internal components results in low friction loss across the valve compared with similar style valves. External Reset The RCW is a differential latching valve with convenient external reset knob. Positive Action Short Stroke Side Diaphragm The design of the side diaphragm incorporates a positive action spring force to assist the movement of the diaphragm away from the clapper when diaphragm chamber water pressure is being evacuated. This action, coupled with the minimal required movement of the roller assembly, results in faster operation upon diaphragm chamber pressure drop and more dependable activation when called upon, again, mitigating the potential issues caused by corrosion. 300 psi Pressure Rating * In honor of the late Robert C. Worthington PE

Available System Trim Configurations The Globe RCW Valve is available pre-trimmed or loose-trimmed (all standard trims are galvanized) in the following system confi gurations: Dry System Valve utilizes dry actuator with optional accelerator Deluge System Valve Electric Actuation Dry Pilot Actuation Wet Pilot Actuation Single Interlock Preaction System Valve Electric Actuation Dry Pilot Actuation Wet Pilot Actuation Double Interlock Preaction System Valve Electric/Electric Actuation Electric/Pneumatic Actuation Non Interlock Preaction System Valve Model RCW Cross Section 25 29 9 26 20 34 22 33 31 8 7 28 24 13 11 30 3 1 16 14 15 10 23 19 12 6 4 5 21 2 17 18 21 32 27 ITEM DESCRIPTION MAT'L. ITEM DESCRIPTION MAT'L. ITEM DESCRIPTION MAT'L. 1 "RCW-2" Body (groove/groove) Ductile Iron 12 Diaphragm Retainer Ductile Iron 23 Roller Arm Hinge Pin Stainless 2 Seat Ring Bronze 13 Diaphragm Rubber 24 Roller Arm Hinge Pin Clip Stainless 3 Clapper Bronze 14 Diaphragm Cover Ductile Iron 25 Reset Plunger Knob Bronze 4 Retaining Ring Stainless 15 Clapper Hinge Pin Stainless 26 Plunger O-Ring Rubber 5 Retaining Bolt Steel 16 Clapper Hinge Pin Bushing Bronze 27 Name Plate Aluminum 6 Clapper Facing Disc EPDM 17 Hand Hole Cover Gasket Rubber 28 Return Spring Stainless 7 Latch Arm Bronze 18 Hand Hole Cover Ductile Iron 29 Reset Plunger Spring Stainless 8 Clapper Latch Bronze 19 Diaphragm Spring Stainless 30 Roller Bushing Bronze 9 Reset Plunger Bronze 20 Reset Bushing Bronze 31 1/2"NPT Plug Steel 10 Push Rod Bronze 21 Cover Bolt Steel 32 Drive Screw Stainless 11 Roller Stainless 22 Clapper Latch Hinge Pin Stainless 33 Clapper Latch Bushing Bronze

Dry Systems: Dry Pipe sprinkler systems are typically used in unheated areas and other locations exposed to freezing temperatures, where water-fi lled pipe cannot be utilized. When set for service, the dry pipe sprinkler system incorporating automatic sprinklers (closed) is pressurized with air or nitrogen. The loss of air pressure through an operated automatic sprinkler, in response to heat from a fi re, permits the Dry Pipe Valve to open and allow a fl ow of water into the sprinkler system piping. Any unheated portion of a building: Warehouses Loading Docks Unheated Attic Spaces Shipping Platforms Cold Storage Parking Garages Outdoor Piers Unheated Attic Spaces Dry Pipe System

Deluge Systems: Deluge systems are used for special hazards where there are easily ignitable and fast burning substances which promote rapid fi re development. They are typically used for: fi re extinguishment, fi re control, or exposure protection. Materials having high rates of heat release Conveyors Water Curtains Fuel Storage Tanks Electrical Transformers Aircraft Hangars Chemical Plants Electric Actuation Wet Pilot Actuation Dry Pilot Actuation

Single Interlock Preaction Systems: Single Interlock Preaction systems are utilized in any portion of a building where it is undesirable to have water fi lled piping over the hazard being protected. These systems typically employ air (nitrogen) under pressure, with a supplemental detection system installed in the same area as the sprinkler system. These valves are activated via a single event, an electrical detector activation, an activation of a pilot sprinkler connected to pilot lines under air pressure (dry pilot), or an activation of a pilot sprinkler connected to pilot lines under water pressure (wet pilot). Computer Rooms Archives Libraries Document Storage Centers Single Interlock Electric Actuation Single Interlock Dry Pilot Actuation Single Interlock Wet Pilot Actuation

Double Interlock Preaction Systems: Double Interlock Preaction Systems are used any portion of a building where fl ooding or inadvertent discharge of water is considered undesirable. These valves are activated via two separate events: an electric activation plus a sprinkler activation. In the case of Electric/Pneumatic Actuation, a detector activation sends an electrical signal to the release panel, opening the solenoid valve. This event would typically be followed by a sprinkler activation, releasing air pressure in the sprinkler piping, allowing the pneumatic actuator to open, and tripping the RCW valve. In the case of Electric/Electric Actuation, a detector activation will send the fi rst electrical signal to the release panel. The activation of a sprinkler will allow air pressure in the sprinkler piping to escape, activating a low air pressure switch, sending the second signal to the release panel, signaling the release panel to open the solenoid valve, tripping the RCW valve. Freezers Valuable Archives Critical Document Storage Double Interlock Electric/Pneumatic Actuation Double Interlock Electric/Electric Actuation

Advancement & Innovation '1 & Done' RCW Valve Patent Pending Low Resistance Roller Arm Easy Access Hinge Pin External Reset

Issue Date: 10/17/2016 www.globesprinkler.com 1 & DONE For more information contact: Customer Service Team - (989) 846-4583 or Your Local Globe Territory Manager