ProLine Interface Technology. Repeater Power Supplies. IsoAmp PWR A 20100

Similar documents
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Analog signal converters CC-E I/I Current / current isolators

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

CompactLogix Power Supplies Specifications

Safety technique. Emergency stop module BO 5988 safemaster

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

MINI MCR-SL-R-UI(-SP)

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Three-phase monitoring relay CM-PFE

Power Supplies 3. SDN-P DIN Rail Series

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

TX OPEN RS232/485 module

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Quick Connect. quick - simple - efficient.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

T0118 T2118 T3118. Instruction Manual

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

Electronic overload relay EF19 and EF45

Digital input modules

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

48 SERIES Relay interface modules 10 A

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

RM4TG20 three-phase network control relay RM4-T - range V

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Contents. Document information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Redundancy Module QUINT-DIODE/40

SINEAX U553 Transducer for AC Voltage

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

1788 Linking Device Specifications

Smart DeviceNet Remote I/O Terminals

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Rosemount 333 HART Tri-Loop

DS 600. A contact free flux gate based current measurement sensor 600A rms

E-STOP relays, safety gate monitors

S-series Mass Connection Solutions

Electronic overload relay EF65, EF96 and EF146

5SV Residual Current Protective Devices

Adjustment functions for both span and shift have been incorporated

PHOENIX CONTACT Features

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Cross-beam scanning system to detect slim objects. 100 mm in

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

3-phase, bidirectional energy meter

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Pressure transmitter For general industrial applications Model A-10

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

HARTING econ 3000 Introduction and features

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Telephone- and leased line modem for industrial applications TD-36

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

38 Series - Relay interface modules A

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

NX safety stand-alone

Power Supplies 3. SDN-C Compact DIN Rail Series

RY2 miniature industrial relays

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

1756 ControlLogix Chassis Specifications

Product and functional description

40 Series - Miniature PCB/Plug-in relays A. Features

is then retained absolutely without interruption.

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

J TB/TW Temperature limiter, temperature monitor

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Inductive sensor NI10-M18-Y1X-H1141

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Digital display DA 48

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

iva Cable & Antenna Analyzer

Relés e Contatores de Estado Sólido SIRIUS

Transcription:

ProLine Interface Technology Repeater Power Supplies Repeater power supply in a 6 mm housing with calibrated switching of output signals, HART transmission and protective separation. The Task Flexible and safe supply of 2-wire transmitters via the 4... 20-mA current loops with simultaneous transmission of data protocols for SMART transmitters / HART communication. Conversion of the output signal into 0 20 ma or 0 10 V, if necessary. The Problems Good isolator properties combined with high transmission accuracy often result in complex systems that cost space and money. Galvanic isolation of the supply and signal processing, however, are frequently indispensable in order to exclude measuring problems right from the start. Thus the range of possible alternatives within the budget is often limited. The Solution Knick is the first manufacturer to provide a repeater power supply for 2-wire transmitters in an extremely compact 6-mm housing - the IsoAmp PWR A 20100. It supplies the transmitter with power and transmits the measurement signal to the output with galvanic isolation and high accuracy. In case a signal other than the 4 to 20 ma current loop signal is required, the repeater power supply provides various output signals which can be selected via DIP switches. The Housing Mounted in a tried and tested modular housing with a width of 6.1 mm and screw terminals. The outputs are selected using DIP switches that can be accessed without opening the housing. The Advantages The new repeater power supply combines small dimensions with excellent features! Protective separation and 0.1 % accuracy also allow use for applications with increased requirements. The Technology The output signal is switchable between 0 20 ma, 4 20 ma and 0 10 V. The calibrated ranges are selected using DIP switches. In addition to the analog signal, the repeater power supply transmits data protocols for SMART transmitters (according to the HART specification). It allows bidirectional communication with the field device via a host computer or HART communicators (hand-held communicator). Of course, HART signals are transmitted unaltered. The width of just 6 mm also allows for the use of the repeater power supply in the tightest of spaces. 48

Facts and Features Extremely flat 3-port isolation in a 6 mm modular housing Flexible and extremely precise Calibrated switching of output signals Quick and easy configuration using lateral DIP switches easy to access, yet protected against accidental adjustment Low-cost assembly Supply of the current loop and galvanic isolation of the measurement signal in one device Protective separation up to 300 V according to EN 61140 SMART transmitter (acc. to HART specification) Cross-connection combs for power supply only wired once for almost any number of parallel repeater power supplies 5-year warranty 5 Year Warranty! 49

ProLine Interface Technology Repeater Power Supplies Product Line Device Input Output Order no. 4 20 ma 0 20 ma 4 20 ma 0 10 V calibrated switching A 20100 P0 24 V DC Accessories Cross-connections Pluggable cross-connection for looping through of the power supply for up to 41 power supply connections of the B 10XXX F0 and A 20XXX F0, splittable Order no. ZU 0542 Specifications Input data Input (current loop) Residual ripple 4 20 ma, supply voltage 16.5 V, constant for 3 22 ma, current limited to max. 25 ma < 10 mv eff Output data Output Output signal with shorted input Output signal with open input 4 20 ma, 0 20 ma or 0 10 V calibrated switching 22 25 ma or 11 12.5 V < 3 ma or 0 for outputs 0 20 ma or 0 10 V Load With output current 10 V ( 500 ohms at 20 ma) With output voltage 1 ma ( 10 kohms at 10 V) Offset Current output 1) < 30 µa Voltage output < 30 mv Residual ripple at output < 10 mv eff Transmission behavior Gain error Current output < 0.1 % meas. val. Voltage output < 0.2 % meas. val. Response time T 90 Communication 2) (output 4 20 ma) < 2 ms Bidirectional transmission of FSK signals between output and current loop according to HART specification 24 V DC (±15 %), approx. 1 W The power supply can be routed from one device to another via cross-connectors. 50

Specifications (continued) Isolation Galvanic isolation Test voltage Working voltage (basic insulation) 3-port isolation between current loop, output and power supply 2.5 kv AC current loop against output / power supply 510 kv AC output against power supply Up to 600 V AC/DC across current loop and output/power supply with overvoltage category II and pollution degree 2, furthermore up to 100 V AC/DC across output and power supply with category II and degree 2 according to EN 61010-1. For applications with high working voltages, take measures to prevent accidental contact and make sure that there is sufficient distance or insulation between adjacent devices. Protection against electric shock Protective separation to EN 61140 by reinforced insulation according to EN 61010-1. Up to 300 V across current loop and output / power supplies with overvoltage category II and pollution degree 2. For applications with high working voltages, take measures to prevent accidental contact and make sure that there is sufficient distance or insulation between adjacent devices. Standards and approvals EMC 3) Product family standard: EN 61326 Emitted interference: Class B Immunity to interference: Industrial environment Approval Explosion protection RoHS conformity culus Listed, file no. E340287, E308146, E340288 Standard: UL 61010-1 and CAN/CSA C22.2 No. 61010-1 Europe: II 3G Ex na IIC T6 Gc X USA: Class I Div.2 GRP A,B,C,D T6 Class I Zone 2 AEx na IIC T6 Canada: Class I Zone 2 Ex na IIC T6 XClass I Div.2 GRP A,B,C,D T6 According to directive 2011/65/EU Further data MTBF 4) Approx. 450 years Ambient temperature Operation: 0 +55 C Transport and storage: -25 +85 C Ambient conditions Design Tightening torque Indoor use 5) ; relative humidity 5 95 %, no condensation; max. altitude 2000 m (air pressure: 790 1060 hpa) 6) Modular housing with screw terminals, 6.1 mm wide See dimension drawings for further measurements 0.6 Nm Ingress protection IP 20 Mounting For 35-mm DIN rail acc. to EN 60715 Connection Weight Conductor cross sections Single wire: 0.5 2.5 mm 2 Stranded wire: 0.5 2.5 mm 2 With ferrule: 0.5 1.5 mm 2 Approx. 50 g 1) Additional error 30 µa for output 0 20 ma 2) HART attenuation < 6 db 3) Slight deviations are possible while there is interference 4) Mean time between failures MTBF according to EN 61709 (SN 29500). Conditions: stationary operation in well-kept rooms, average ambient temperature 40 C, no ventilation, continuous operation 5) Closed, weather-protected operating areas (stationary operation), water or wind-driven precipitation (rain, snow, hail, etc.) excluded 6) Lower air pressure reduces the allowable working voltages. 51

ProLine Interface Technology Repeater Power Supplies Block Diagram Current loop + Z 30 Z 30 + Output 0/4 20 ma 0 10 V + 24 V DC 52

Typical Application 2-wire transmitter Current loop repeater power supply 1 2 5 6 Output circuit Input R L e.g., PLC recorder 3 4 with HART transmission R L 230 ohms HHT Hand-Held Terminal HHT HHT Dimension Drawing and Terminal Assignments 6.1 90 Terminal assignments 1 Current loop + 2 Current loop 3 4 + 5 Output 6 Output + 87.9 86.9 Conductor cross-sections: single wire 0.5 2.5 mm 2 stranded wire 0.5 2.5 mm 2 with ferrule 0.5 1.5 mm 2 97.8 All dimensions in mm 53