Sievers 860 Laboratory TOC Analyzer & GE Autosampler RT12

Similar documents
The Sievers 900 Series TOC Analyzers

TEST REPORT: SIEVERS M-SERIES PERFORMANCE SPECIFICATIONS

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

Multi-Range Programmable DC Power Supplies 9115 Series

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

Density/Specific Gravity/ Concentration Meter DMA 500

Mitos P-Pump. product datasheet

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

4Sight Calibration Management Software

Melting Point Apparatus

TRL-onlineTOC Monitor is designed for monitoring carbon content in

GC-xt. The most flexible GC /GC-MS liquid sample injector

ORGANIC SAMPLE PREPARATION

Multi-Range Programmable DC Power Supplies 9115 Series

Wirbelstrom Prüfsysteme. eddyliner. digital

Phoenix Apollo Laboratory TOC Analyzers and Services Designed To Meet Your Needs

Conductivity Sensor Calibrations to Meet Water Industry Requirements

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

The PACE5000 Modular Pressure Controller/Indicator

OVERVIEW OF STANDARD 7E & STANDARD 20

Datex-Ohmeda Critical Care Monitor

Validate Network Connectivity in Less Than 10 Seconds

Cisco Unified IP Phone Power Injector

Wireless Data Logger Monitoring Systems

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

Direct Water purification system Pure & ultrapure water directly from tap water

ADU 5. Automatic Distillation Unit

Peel Back Force Tester GPD s Peel Back Force Tester with FORCEWare software is being used to set peel back standards for the entire industry

User Manual. EtherUSB

PE8216/PE8324. Energy Intelligence Solutions

Tracer Summit Web Server

How To Use An Irius Pid Detector

ETV Joint Verification Statement

Titrette. class A precision. The next generation Digital Burette!

Everything you need for protection scheme testing

DENSITY MEASURING SYSTEMS

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Agilent 87421A/87422A Power Supply

HMI display Installation Guide

Portable Density/Specific Gravity/Concentration Meter DMA 35

BASIC SOUND LEVEL METERS

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Thermo Scientific Sorvall T3 and G3 Centrifuge Series. Capacity, reliability and performance for routine applications

Smart. Scalable. Simple.

8-Port PoE Network Switch

MINIMAT-EC-Servo Screwdriver Spindles

DMA-1 Direct Mercury Analyzer

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

endless One platform possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success.

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

Product Information Sheet UH28CS-12kV Hi Pot Tester

HP rack and power infrastructure products are designed and developed to be used specifically with HP servers and storage.

KNC Model 3666 Automatic Pressure Calibration System

500/600/1000. User Manual June 2011 Rev v061311

How To Control A Medical Device With A Pc System

Agilent Cary 60 UV-Vis

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

MATHESON STACK EMISSION CALIBRATION PROGRAM. Experience the MATHESON Commitment to Supply Chain Excellence

ColorDial Pro Easily configure and control LED light shows

limit to percentage levels, a limited working range translates

SMART Board interactive flat panel with appliance Model 8055ie-SMP

MILESTONE H E L P I N G C H E M I S T S

Sales and Support in the US and CA by: NuAire, Inc Fernbrook Lane Plymouth, MN

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

QuickSpecs. HP Compaq t5525 Thin Client. Overview


DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

User Guide. Temperature and Humidity Datalogger. Model 42280

USER GUIDE. For more information visit

Data Sheet FUJITSU Storage ETERNUS LT20 S2 Tape System

INNOVATION TO MEET YOUR NEEDS

Karl-Fischer Titration the method for determining water

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

QuickSpecs HP TFT7600 G2 KVM Console and Monitor (TFT7600 G2)

Baumann Flexsleev Sanitary Control Valve

MD SD MS SS MH SH ML SL MT ST

OEM-EP Pressure Controllers

Online Infrared Flue Gas Analyzer Gasboard 3000

TurbiDirect TurbiCheck TurbiCheck WL

MCR1900 Media Converter 19-Slot Chassis

1.44 kw Programmable DC Power Supplies XLN Series

Toxicity. Toxicity monitoring technologies for on line, on location and the laboratory

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

±15 V Current-Limited Power Supply

Lighting. Midmark Animal Health Products

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

ACL 395 Resistivity Meter

NEW. EVEN MORE data acquisition and test stand automation

Elemental analyzer multi EA 5000

Featuring fast rotor exchanges with AUTO-LOCK

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

History of Innovation

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Transcription:

Water & Process Technologies Fact Sheet Sievers 860 Laboratory TOC Analyzer & GE Autosampler RT12 High Performance at an Affordable Cost for General Pharmaceutical Water Testing Requirements, Inc. www.geinstruments.com/india

The Sievers 860 Affordable, High Performance The Sievers 860 Laboratory Total Organic Carbon (TOC) Analyzer from was designed specifically for pharmaceutical applications. Based on the proven technology used in the bestselling Sievers 900 Laboratory model, the new Sievers 860 provides excellent analytical performance at an affordable price. It offers a streamlined feature set designed to meet general pharmaceutical water testing requirements. Like other Sievers TOC analyzers, the Sievers 860 is easy to set up, operate and maintain, and requires no special operator training. To keep cost of ownership low, the Sievers 860 needs no internal reagents. The innovative DataPlus software makes the Sievers 860 more than an analyzer. Featuring an intuitive PCbased interface, the software lets you easily manage the data sample points in your water system and comply with global TOC monitoring requirements, such as Applications the US, European, Chinese, Indian, and Japanese Pharmacopeias (USP, EP, ChP, IP, and JP). Manufactured by the General Electric Company (GE), Sievers TOC Analyzers bring a strong tradition of innovation, quality, and reliability. When regulatory compliance and public safety is critical, partnering with an established, trusted manufacturer is essential to control risks. Sievers is the leading pharmaceutical TOC analyzer brand, and more than 10,000 Sievers TOC Analyzers have been installed throughout the world. The Sievers 860 TOC Analyzer was designed for general pharmaceutical water testing, including Water for Injection (WFI) and Purified Water (PW). It has a linear range of 0.3 ppb to 1.5 ppm, and offers a more robust alternative to the direct conductivity method. Sievers 860 Highlights Proven Sievers Technology The Sievers 860 is based on the industry-leading Sievers 900 Laboratory TOC Analyzer. It uses the Sievers Membrane Conductometric TOC technology that provides unsurpassed analytical performance and reliability. Regulatory Compliance The Sievers 860 complies with the IP, USP, EP ChP, JP, and other major global pharmacopeia requirements. Affordability The Sievers 860 s streamlined feature set was carefully designed to reduce costs, but still offer high performance for select pharmaceutical applications. One-Touch Operation The Sievers 860 can operate with or without a PC. Using the Analyzer keypad, standard TOC measurements can typically be run with just a single push of a button. Best-in-Class Software The Sievers 860 has an intuitive PC-based interface for easy analyzer operation, data management, document creation, and pharmaceutical regulatory compliance. The DataPlus software gives operators new insight into water system performance. DataPlus lets you monitor each sampling point, chart trends, and quickly identify changes in water quality. Low Maintenance The Sievers 860 provides one-year calibration stability and needs only a few hours of annual preventive maintenance. Reliable Company and Brand Established in 1878, GE is known for continuous innovation and high quality. GE s Sievers brand brings industry-leading TOC analysis technology to the global pharmaceutical market. GE s skilled service engineers and distributor network in India are ready to address customer questions and service needs.

Sievers Membrane Conductometric TOC Technology The Sievers 860 uses the Sievers Membrane Conductometric Detection method, which has proven to be an extremely reliable technique for measuring TOC. It uses a gas-permeable membrane that selectively passes only the CO 2 produced from the oxidation of organics. By preventing compounds such as acids, bases, and halogenated compounds from interfering with the measurement of CO 2 from oxidation, the Membrane Conductometric Method delivers unmatched sensitivity, selectivity, stability, accuracy, and precision. This technique also can tolerate higher conductivity and remove inorganic carbon more effectively than TOC analyzers that use the direct conductometric technology. DataPlus Software The Sievers 860 can operate standalone or with a PC. When using a PC, the innovative, easy-to-use DataPlus* software allows users to operate the Sievers 860, manage and analyze water sample data, and comply with pharmaceutical water testing regulations. The most robust laboratory TOC data management tool available, DataPlus lets you: Set up sampling protocols in just minutes. Create trending charts for a single sample point for internal quality control and troubleshooting. Export data as.csv or.xls files, and print reports and trending charts in pdf format. Track consumables usage and conduct routine maintenance easily. Run up to four Sievers TOC analyzers from one PC via an Ethernet connection. Firmware Upgrades Firmware can be updated easily using a USB key. You can take advantage of the latest features and optimize performance without changing hardware. Options and Accessories DataGuard Software Sievers DataGuard software for the Sievers 860 offers comprehensive support for compliance with the FDA s requirements for control of electronic records and electronic signature. DataGuard provides an administratively controlled user access system, complete audit trail functionality, and electronic signature management for compliance with 21 CFR Part 11. DataPlus Sample Point Trending Graph DataPlus Measurement Screen

GE Autosampler RT12 The GE Autosampler is a highly-automated, compact accessory for optimizing laboratory TOC measurement and is designed for use with the Sievers 860. The GE Autosampler RT12 is designed to increase productivity and enhance ease of use. Offering the highest degree of reliability, the RT12 requires little maintenance or adjustment. Key features and benefits include: Single-line connection and operation via DataPlus With only one cable, the GE Autosampler RT12 can connect to both the Sievers 860 TOC analyzer and the power supply. Using a computer and the DataPlus software you can operate the Autosampler easily. High sampling capacity and simultaneous in-vial sparging The GE Autosampler RT12 can handle up to 12 40-mL vials. Because of its rotary design, it is easy to set up the sampling sequence according to the vial position in the rack. The RT12 enables overnight calibration and verification to ensure the Sievers 860 is ready to go the next day. The GE Autosampler RT12 has the same sipper needle design as the Sievers 860,so it can conduct in-vial sparging before sampling. When IC is high especially when it is involatile IC acidification is needed. Sparging effectively reduces the inorganic carbon and enhances measurement accuracy. Compact, space-saving size The RT12 s slim 23.1-cm wide profile requires minimal bench space. When operated side-by-side with the 21.5-cm wide Sievers 860 Laboratory Analyzer, the two units occupy just 46.6 cm of horizontal space. The RT12 only requires three connections a sample inlet tube, a gas liquid waste outlet tube, and a power cable to the Sievers 860 keeping the lab bench neat and clean. Sievers Certified Standards and TOC Vials offers Sievers Certified Reference Materials, including calibration and verification standards, for the Sievers 860, as well as reliable and economical 40-mL TOC vials. GE Autosampler RT12 Specifications 1 Capacity Twelve (12) 40-mL vials Power Supply Power supplied by the Sievers 860 Laboratory TOC Analyzer Ambient Temperature 10 C to 40 C Normal Operating Environment Intended for indoor use only Maximum Relative Humidity Up to 95%, non-condensing Maximum Altitude 3,000 m (9,843 ft) Dimensions H: 36.8 cm (14.5 in); W: 23.1 cm (9.1 in); D: 25.4 cm (10.0 in) Weight 3.9 kg (8.6 lb) Safety Certifications CE

Sievers 860 Laboratory System Specifications 1 Total Organic Carbon Linear Range Precision Accuracy Analysis Time Sample Flow Rate (nominal) 0.3 ppb 1.5 ppm TOC 0.1 ppb or 1%, whichever is greater ± 5% at 500 ppb C of sucrose 6 minutes Analysis mode: 0.25 ml/min Fast Flush (between samples): 0.5 ml/min Sample ph <3 Sampling Method Grab sampling Operation PC or standalone operation; one PC can control up to four analyzers Analyzer Specifications Power Requirements 100 240 ±10% VAC, 60 W, 50/60 Hz Fuses T1.6 A, 250 VAC (SloBlo), size 5 x 20 mm (appliance inlet) Ambient Temperature 10 C to 40 C Normal Operating Environment Intended for indoor use only Maximum Relative Humidity Up to 95%, non-condensing Maximum Altitude 3,000 m (9,843 ft) Sparge Gas (if used) Inlet pressure: 30 psig to 50 psig Sparge Gas Flow Rate 120 ml/min to 150 ml/min Calibration Stability Typically stable for 12 months Outputs One USB port to support printer or Flash drive, and one Ethernet port Installation/Overvoltage Category II Safety Certifications CE, ETL listed. Conforms to UL Std. 61010-1. Certified to CSA C22.2 No. 61010-1. Pollution Degree 2 Display Color LCD Dimensions H: 43.0 cm (16.9 in); W: 21.5 cm (8.5 in); D: 40.5 cm (15.9 in) Weight 10.5 kg (23.0 lb) * Trademark of General Electric Company; may be registered in one or more countries. 1 Stated analytical performance is achievable under controlled laboratory conditions that minimize operator and standards errors. The Americas 6060 Spine Road Boulder, CO 80301-3687 USA T +1 800 255 6964 T +1 303 444 2009 F +1 303 527 1797 geai@ge.com www.geinstruments.com Europe/Middle East/Africa Unit 3, Mercury Way Urmston, Manchester UK M41 7LY T +44 (0) 161 864 6800 F +44 (0) 161 864 6829 geai.europe@ge.com India C 402, Delphi Hiranandani Business Park Powai, Mumbai India - 400076 T +(91) 900 4343626 F +(91) 4005 9840 geai.india@ge.com www.geinstruments.com/india ISO 9001:2008 QUALITY MANAGEMENT SYSTEM 2011, General Electric Company. All rights reserved. 300 00228 Rev B MC11-168