Effectiveness of Engineering controls (LEVs)

Similar documents
Controlling airborne contaminants at work

Scientific and analytical consultancy services for industry

SPECIAL APPLICATIONS

Procedures for the Effective Use of Biological Safety Cabinets

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

Local Exhaust Ventilation (LEV) Guidance

Principles of Ventilation. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

Chemical Fume Hoods. Environmental Health and Safety

Clearing the air A simple guide to buying and using local exhaust ventilation (LEV)

Risk Assessment: Biosafety Cabinet

Industrial Ventilation Design Guidebook Chapter 10 LOCAL VENTILATION

Controlling health risks from rosin (colophony)-based solder flux fume

BIOLOGICAL SAFETY CABINET PROGRAM

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

Fume Cupboard Guidance

Laminar Flow Cabinets and Workstations

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

Fume Hood Questions and Answers

Ductless Spray Booth Series

Best Practices for Handling Nanomaterials in Laboratories

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

Chapter 12 Industrial Ventilation

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

Department of Environmental Health and Safety & Emergency Management

WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems

Breathe In... FRONT COVER. Fresh Air By Design

Syracuse University s Guidelines for Work Involving Materials Containing Trace Asbestos (Asbestos at a Concentration Less than 1%)

JANUARY 2013 GUIDANCE NOTES ON HEATING, VENTILATION AND AIR- CONDITIONING (HVAC) SYSTEMS FOR MANUFACTURERS OF ORAL SOLID DOSAGE FORMS

A SELF-EVALUATION CHECKLIST of BEST PRACTICES for AUTO REFINISH SHOPS and SCHOOLS

SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR

Downflo workstation DuSt ColleCtorS

Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested

My Industrial Ventilation System Used to Work: The Role of System Documentation in Restoring System Performance

SECTION TESTING, ADJUSTING, AND BALANCING

Visualisation and control of solder fume exposure

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

OSHA and Welding Exhaust

ANNEXURE I SERVICE LEVEL AGREEMENT BETWEEN. The Client. and. The Contractor/Service Provider. HVAC Systems Maintenance Service

CONFINED SPACE ENTRY WORK STANDARD

Why and when to replace your 3M Filters!

Geismar Site Reviewed: 07/05/16 Effective: 07/05/16 Supersedes: 08/04/14 Preparer: Owner: Approver: S/IH Team Leader S/IH Team Leader Manager LA Hub

PANDA SPRAY BOOTH FILTER INFORMATION

World Health Organization WHO Technical Report Series, No. 961, 2011

Guardian Fire Safety Solutions FIRE RISK CONTROL IN WELDING FUME EXTRACTION SYSTEMS

GENERAL VENTILATION HSG202

British Columbia Institute of Technology. BCIT Safety Manual ASBESTOS MANAGEMENT

ASBESTOS AWARENESS IN THE WORKPLACE. This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation.

Cleanroom Solutions Ltd T: F: E: W:

BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150

Asbestos Management. 2. Introduction. Contents

SAFE USE OF MICROBIOLOGICAL SAFETY CABINETS

Combustible dust. How to use this guide. Combustible Dust

GUIDELINES ON SAMPLING STRATEGY AND SUBMISSION OF AIR MONITORING / SAMPLE ANALYSIS REPORT

During Various Aluminum Fabricating Operations

Spetec Laminar Flow Systems. Operating Instructions

Stainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.

CIBSE Guide M: Maintenance engineering and management Statutory compliance legislation and guidance

NFPA Combustible Dust Compliance and the Industrial Ventilation System

Fumigation of Safety Cabinets

CHAPTER 4 VENTILATION

Casey C. Grant, P.E., FSFPE Research Director Fire Protection Research Foundation

APPLICATION OF ERGONOMIC PRINCIPLES ON THE DESIGN OF SPECIFIC TOOLS FOR THE OPENING AND CLOSING OF FLY VALVES.

IEQ Management Plan. Denver Museum of Nature and Science ECF Addition

Spetec. Laminar Flow Box. Portable Clean Room Technology

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

TATA Scunthorpe Queen Anne- taphole suction hood optimisation by CFD simulation and physical modelling

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

LAMINAR FLOW CABINETS

Restaurant & café guide

Policy for the Management of Asbestos in Buildings

Do you remove fumes from robotic welding and laser cutting?

SUBSTANCES HAZARDOUS TO HEALTH

Sandblasting & Silica Exposure Control Plan

74 Chapter CO 2 Cleaning

Self Assessment Exercise

Mould Mould A Basic Guide

Protection, safety, reliability. And more. LAMINAR FLOW CABINETS AND SYSTEMS

Biosafety Level 2 (BSL-2) Safety Guidelines

Position Description Questionnaire

Both health-care facility classification and area classification, as per CSA, determine the design requirements.

CSA Z Infection Control during Construction, Renovation and Maintenance of Health Care Facilities Overview and Case Studies

EACO DOP / PAO TESTING GUIDELINE 2013

Essam E. Khalil

SUPPLEMENTARY GUIDELINES ON

Restaurant and Café Risk Management Guide. Don t Risk It!

PERSONAL PROTECTIVE EQUIPMENT HAZARD ASSESSMENT, EQUIPMENT SELECTION AND TRAINING DOCUMENTATION

Chapter 7 - Control of Dust Transmission

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

Control Provisions under the Air Pollution Control Ordinance

In addition, flammable solvents and thinners are often mixed with the above substances.

Appendix A Primary Containment for Biohazards: Selection, Installation and Use of Biological Safety Cabinets

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

Construction Silica Exposures and Solutions

9/15/2011. Presented by: Jason Reason, CIH, CSP, CHMM Senior Industrial Hygienist Indiana Occupational Safety and Health Administration

WORKING IN CONFINED SPACES GUIDELINES

Benefits of. Air Flow Management. Data Center

presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13

Transcription:

Carlos Fito López Responsable A.T. Seguridad & Coordinador de Proyectos de Nanoseguridad cfito@itene.com Sevilla 3 de Diciembre de 2014 Jornada de Nanotecnología y prevención de riesgos Nuevos desarrollos en la evaluación y control de la exposición laboral a NMs: Experiencias en el marco del proyecto LIFE NanoRISK

Índex 1. State of the Art regarding the effectiveness of LEVs 2. Testing activities and progress so far Jornada de Nanotecnología y prevención de riesgos Nuevos desarrollos en la evaluación y control de la exposición laboral a NMs: Experiencias en el marco del proyecto LIFE NanoRISK 2

1. State of the Art regarding the effectiveness of LEVs Jornada de Nanotecnología y prevención de riesgos Nuevos desarrollos en la evaluación y control de la exposición laboral a NMs: Experiencias en el marco del proyecto LIFE NanoRISK 3

1. State of the Art regarding the effectiveness of LEVs Engineering control measures Engineering control measures vary depending on the requirements of each workplace and it may be necessary for those working with ENPs to use a combination of methods to control exposure. Total enclosure or partial enclosures such as fume cupboards will be reasonably practicable for many operations with ENPs, including manufacture/synthesis and weighing. For cutting, sawing or polishing, simpler extracted enclosures and other LEV devices such as capturing/receiving hoods or downdraught benches may be appropriate. Particulate airborne materials have also been shown to be captured by electrostatic collectors However, certain work activities may lead to higher potential exposure and therefore additional control measures may be necessary. 4

1. State of the Art regarding the effectiveness of LEVs Local Exhaust Ventilation (LEV Local Exhaust Ventilation is an engineering control system to reduce exposures to airborne contaminants such as dust, mist, fume, vapour or gas in a workplace. LEV systems are used to control emissions from materials handling processes such as mixing, weighing and bagging. Most systems have the following parts Hood: This is where the contaminant cloud enters the LEV. Ducting: This conducts air and the contaminant from the hood to the discharge point. Air cleaner or arrestor: This filters or cleans the extracted air. Not all systems need air cleaning. Air mover: The engine that powers the extraction system, usually a fan. Discharge: This releases the extracted air to a safe place 5

1. State of the Art regarding the effectiveness of LEVs Local Exhaust Ventilation (LEV) Recommended containment systems on the basis on the levels of exposure, considering the use of a capturing hood for small levels of concentrations, and a total enclosure for high levels of exposure. 6

1. State of the Art regarding the effectiveness of LEVs Local Exhaust Ventilation (LEV) 7

1. State of the Art regarding the effectiveness of LEVs Local Exhaust Ventilation (LEV To ensure the effectiveness of LEV systems, it is essential that the entry hood will be always positioned correctly and adequate capture velocity maintained. As in general ventilation, maintenance and cleaning of the systems may pose an additional risk of exposure. Hoods have a wide range of shapes, sizes and designs. They control contaminant clouds in three different ways according their classification: Enclosing hood Receiving hood. Capturing hood 8

1. State of the Art regarding the effectiveness of LEVs Local Exhaust Ventilation (LEV) Classification Description Assigned typical value Local exhaust ventilation (LEV) Guidance images - Receiving hoods Canopy hoods A canopy hood placed over a hot process to receive the plume of contaminant-laden air given off. For cold processes with no thermal uplift, canopy hoods are ineffective. 0.5 Other receiving hoods A receiving hood can be applied wherever a process produces a contaminant cloud with a strong and predictable direction (e.g. a grinding wheel). The contaminant cloud is propelled into the hood by process-induced air movement. The face of the hood must be big enough to receive the contaminant cloud and the extraction empties the hood of contaminated air at least as fast as it is filled. 0.2 9

1. State of the Art regarding the effectiveness of LEVs Local Exhaust Ventilation (LEV) Classification Description Assigned typical value Local exhaust ventilation (LEV) Guidance images - Capturing hoods Movable capturing hoods Fixed capturing hoods Movable LEV systems such as hoods with extendable arms. The design of the system does not prevent work being performed outside the capture zone of the system and worker behaviour can influence the effectiveness of the system. Fixed capturing hoods located in close proximity of and directed at the source of emission. The design is such that the work is performed in the capture zone of the ventilation system and the capture is indicated at the workplace. 0.5 0.1 On-tool extraction LEV systems integrated in a process or equipment that cannot be separated from the primary emission source. 0.1 10

1. State of the Art regarding the effectiveness of LEVs Local Exhaust Ventilation (LEV) Classification Description Assigned typical value Local exhaust ventilation (LEV) - Enclosing hoods Any form of permanent encapsulation or encasing of the source of which maximally one side is open with a well designed local exhaust ventilation system (e.g. laminar air flow). Guidance images Fume cupboard Horizontal/down ward laminar flow booth The design of both the enclosure and the ventilation system is such that the influence of worker behaviour is minimal (e.g. an alarm system prevents the worker from using the fume cupboard in case the system is not working properly). In a horizontal laminar flow booth, contaminated air is extracted through holes situated at the rear of the booth which creates a horizontal laminar air flow. The air is filtered prior to being discharged to the atmosphere. The booth contains the source and has maximally one side open. In a downward laminar flow booth, a curtain of descending laminar air flow is created between the ceiling and the rear of the booth where exhaust grills are located in the lower section. The booth contains the source and has maximally one side open.. 0.01 0.1 Other enclosing hoods Any form of permanent encapsulation or encasing of the source of which maximally the front side is open with a proper local exhaust ventilation system. 0.1 11

Nanotecnología y efectos adversos en la salud: Nanotoxicología 2. Testing activities and progress so far Jornada de Nanotecnología y prevención de riesgos Nuevos desarrollos en la evaluación y control de la exposición laboral a NMs: Experiencias en el marco del proyecto LIFE NanoRISK 12

2. Testing activities and progress so far Progress to date Fume Cupboard Effectiveness testing: The effectiveness of fume cupboards were conducted by means of repeated measurements wit a CPC/OPS system at the researcher s breathing zone under different locations. The operations included: - Opening and closing containers (Tsai et al. (2009) - Pouring or transferring particles from beaker to beaker (15 g /NP) - Mixing NPs with solvents / water - Operator motion: two arms shall be positioned inside the cabinet near the contaminant source 13

2. Testing activities and progress so far Scientific Results Selection of RMMs When using a local exhaust system, do not directly exhaust into the work environment any effluent (air) that is reasonably suspected to contain nanomaterials. The exhaust air should be passed through a HEPA filter and, when feasible, released outside the facility. Storage of materials in the chemical hood should be minimized or eliminated. Materials stored in the hood can adversely affect the containment by disrupting airflow. If items must be placed inside the hood, make sure they are placed near the back and do not block the air slots. 14

2. Testing activities and progress so far Scientific Results Selection of RMMs Powder-handling enclosure Constant flow Fume Cupboard 15

2. Testing activities and progress so far Scientific Results Selection of RMMs 16

2. Testing activities and progress so far Scientific Results Selection of RMMs 17

Agradecimientos: GRACIAS POR SU ATENCIÓN cfito@itene.com 18