What is the difference between BOD, COD or TOC? Why do I have to measure them?

Similar documents
NANYANG TECHNOLOGICAL UNIVERSITY. School of Civil and Environmental Engineering. CV2701: Laboratory 2A. Laboratory Manual. For

BALANCING REDOX EQUATIONS. Each redox equation contains two parts -- the oxidation and reduction parts. Each is balanced separately.

How to measure Ammonia and Organic Nitrogen: Kjeldahl Method

Nutrient Removal at Wastewater Treatment Facilities. Nitrogen and Phosphorus. Gary M. Grey HydroQual, Inc X 7167

Presented by Paul Krauth Utah DEQ. Salt Lake Countywide Watershed Symposium October 28-29, 2008

Balancing chemical reaction equations (stoichiometry)

GUIDELINES FOR LEACHATE CONTROL

WASTEWATER TREATMENT OBJECTIVES

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

POINT SOURCES OF POLLUTION: LOCAL EFFECTS AND IT S CONTROL Vol. II - Technologies for Water Pollution Control - Wang Jianlong

Unit 1. Physical, chemical and biological Characteristics of Wastewater

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

CHEMICAL DETERMINATION OF EVERYDAY HOUSEHOLD CHEMICALS

Water Treatment Filtration Lab. discharged into an aquatic ecosystem? We had to build a water filtration system with

Module 5: Combustion Technology. Lecture 33: Combustion air calculation

Floating Treatment Wetland Technology: Nutrient Removal from Wastewater

Dissolved Oxygen and Aquatic Primary Productivity1

Metabolism: Cellular Respiration, Fermentation and Photosynthesis

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Module 16: The Activated Sludge Process - Part II Instructor Guide Answer Key

Basic Chemistry of Chlorination

1 Environmental Leverage Inc Dogwood Dr. Suite A, North Aurora, IL EnvironmentalLeverage.com

Figure 5. Energy of activation with and without an enzyme.

Table 1.1: Typical Characteristics of Anaerobically Digested Wastewater

Which of the following can be determined based on this model? The atmosphere is the only reservoir on Earth that can store carbon in any form. A.

Water and Wastewater. Sample Collection and Analysis

EPB 311- Strategies for Dealing with Groundwater Treatment Systems Having High Natural Ammonia

Toxic Municipal Waste Water Treatment

How To Calculate Mass In Chemical Reactions

Chapter 16: Tests for ions and gases

Bioremediation of Petroleum Contamination. Augustine Ifelebuegu GE413

Properties of Acids and Bases

Removing Heavy Metals from Wastewater

Laboratory analysis for wastewater treatment, industrial monitoring, and environmental protection

1.85 WATER AND WASTEWATER TREATMENT ENGINEERING FINAL EXAM DECEMBER 20, 2005

Experiment 8 - Double Displacement Reactions

NAJAFGARH DRAIN-SAMPLING AND ANALYSIS

PHENOLIC AND ANTIOXIDANT ASSAYS. Gaziosmanpaşa University

IB Chemistry. DP Chemistry Review

SUPPLEMENTARY TOPIC 3 ENERGY AND CHEMICAL REACTIONS

Biology 3A Laboratory: Enzyme Function

ENVIRONMENTAL AND ECOLOGICAL CHEMISTRY Vol. II Chemistry of Wastewater - Timothy G. Ellis

Nitrogen Cycling in Ecosystems

WASTEWATER TREATMENT

Facility Classification Standards

Glossary of Wastewater Terms

The Nitrogen Cycle. What is Nitrogen? Human Alteration of the Global Nitrogen Cycle. How does the nitrogen cycle work?

AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER

Lab #11: Determination of a Chemical Equilibrium Constant

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

On line Analysis of Organic in Water

11-1 Stoichiometry. Represents


ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY. Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc.

Cellular Respiration: Practice Questions #1

Overview of Best Available Technologies for Onsite Septic Systems and Management Considerations Presentation to NAHB

1. Inspection and monitoring... 3

Summer Holidays Questions

Chemical Equations & Stoichiometry

The Empirical Formula of a Compound

Properties of Acids and Bases

Name Date Class STOICHIOMETRY. SECTION 12.1 THE ARITHMETIC OF EQUATIONS (pages )

QuickCODultra. Online COD for every kind of water. Especially for the rough stuff. Fast. Precise. Reliable. COD-ANALYSis

Chapter 14 Quiz. Multiple Choice Identify the choice that best completes the statement or answers the question.

Troubleshooting Your RO

THE ACTIVITY OF LACTASE

LIMNOLOGY, WATER QUALITY

Enteric Unknowns Miramar College Biology 205 Microbiology

1.3 Wastewater and Ambient Water Quality

Bioremediation of contaminated soil. Dr. Piyapawn Somsamak Department of Environmental Science Kasetsart University

Biodegradable Certification Standard

Hints and Tips on Physicochemical, and human health related endpoints

Provided below is a description of the processes generating wastewater in a poultry plant and a typical pretreatment and full treatment system.

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Vitamin C Content of Fruit Juice

Trichloramine and Asthma in Swimming pools & spas Problem solved

Chapter 1 The Atomic Nature of Matter

Laboratory 5: Properties of Enzymes

Chapter 1: Moles and equations. Learning outcomes. you should be able to:

CHAPTER 7: REMEDIATION TECHNOLOGIES FOR CONTAMINATED GROUNDWATER

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

Name Section Lab 5 Photosynthesis, Respiration and Fermentation

Stage 1 Desired Results

Chemical Proportions in Compounds

Lesson Plan: How Do We Know What is Healthy Water?

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Don t spit in the well - you may need to drink from it! -- Unknown, Russia.

Chapter An (1) is a substance that speeds up the rate of a. biochemical reaction. All living (2) make enzymes.

Honors Chemistry: Unit 6 Test Stoichiometry PRACTICE TEST ANSWER KEY Page 1. A chemical equation. (C-4.4)

Chemical Changes. Measuring a Chemical Reaction. Name(s)

Phosphorus Removal in Wastewater Treatment

Total Suspended Solids Total Dissolved Solids Hardness

UVC LEDs for. Environmental Monitoring

Canada-wide Strategy for the Management of Municipal Wastewater Effluent

Comparing Levels of Phosphates in Dishwasher Detergents

CHM220 Addition lab. Experiment: Reactions of alkanes, alkenes, and cycloalkenes*

RESIDENTIAL TREATMENT SYSTEMS

Transcription:

What is the difference between BOD, COD or TOC? Why do I have to measure them? Almost all treatment plants are required to measure one of these three items as a measure of the pollution value in the water. COD should always measure higher than TOC and then BOD. COD or Chemical Oxygen Demand is the total measurement of all chemicals in the water that can be oxidized. TOC or Total Organic Carbon is the measurement of organic carbons. BOD or Biological Oxygen Demand is supposed to measure the amount of food (or organic carbons) that bacteria can oxidize. COD is usually measured and the test is simple and easy to perform with the right equipment and can be done in 2 hours. BOD usually takes 5 days and TOC used to require large expensive pieces of equipment that could measure the sample in minutes, but was cost prohibitive. There are now test in tube kits that utilize COD digestors to run a test similar to a COD test method. Below are more detailed specifics on each test. Why do I have to measure them? The government came up with these test methods as a way to determine the amount of pollution in a water stream to try to control and limit the amount of chemicals that can pollute the lakes and rivers if left in a final effluent or discharge stream. Some municipalities want to measure the amount of chemicals in the incoming stream in order to asses surcharges as a way of measuring how much additional treatment their plant will have to do in order to get the incoming water clean. It is not only important to know which test you are being measured on, but why, how the sample is pulled and the variations on how they perform the test method. Garbage in, garbage out, correct sampling procedures and methods are critical and can make the difference in violating a permit or not. Just because a lab says they perform BOD does not necessarily mean they perform the procedures the exact same way. Check on the exact methods used. Did you know some labs do not add bacterial seed cultures? If there are few or very little bacteria in the sample, it will show that the BOD is low. It there are biocides present, it will show the result as low. If there are high levels of ammonia present in the sample or bits of algae present, a false high BOD reading will show up. If the sample sits for a few days and turns septic before the test is run, it will require more oxygen and if not set up properly, again a false reading will occur.

What is Chemical Oxygen Demand? A COD test measures all organic carbon with the exception of certain aromatics (benzene, toluene, phenol, etc.) which are not completely oxidized in the reaction. COD is a chemically chelated/thermal oxidation reaction, and therefore, other reduced substances such as sulfides, sulfites, and ferrous iron will also be oxidized and reported as COD. NH3-N (ammonia) will NOT be oxidized as COD. The use of COD results for wastewater compliance monitoring is increasing. To measure oxygen demand, biochemical oxygen demand (BOD) relies on bacteria to oxidize readily available organic matter during a five-day incubation period. COD uses strong chemicals to oxidize organic matter. Generally, COD is preferred to BOD for process control measurements because results are more reproducible and are available in just two hours rather than five days. By the time you have the results from a five day test, the plant conditions are no longer the same, so real time monitor and control can not be relied upon by the use of BOD. COD is a quick and easy measurement to get a snap in time picture of what is going on in the system, and with trending, long term predictions can be made and monitor and control of the process at the wastewater treatment plant can be optimized and controlled. BOD simulates the actual treatment plant process by measuring the organic material microorganisms can oxidize. Although COD is comparable to BOD, it actually measures chemically oxidizable matter. The COD test is not a direct substitute for the BOD test; however, a ratio usually can be correlated between the two tests. This requires COD versus BOD testing over a specified period of time. For industrial samples, COD may be the only feasible test because of the presence of bacterial inhibitors or other chemical interferences, which would interfere with a BOD determination. COD testing also gives the fast measurements required in many treatment systems for informed decisions regarding process control adjustments. Many industrial and municipal laboratories find that parallel COD and BOD testing is beneficial because the COD test can be used to target a specific BOD range. The need for multiple BOD dilutions is minimized or eliminated. What is Total Organic Carbon? Organic matter content is typically measured as total organic carbon and dissolved organic carbon, which are essential components of the carbon cycle. The Total Organic Carbon test measures all organic carbon as CO2. Therefore, all inorganic CO2, HCO3-, etc. Must be removed prior to the analysis. TOC is often used when levels of organic matter (OM) are low. Total organic carbon is a good parameter to measure and actually a more accurate indication of some of the pollutants that cause the most problems than a BOD test. TOC doesn't differentiate between that portion of organic carbon, which can be metabolized (assimilated).

TOC used to be measured by expensive analyzers. Below are some of the older methods with analyzers. Typically TOC analyzers are composed of three primary categories: combustion oxidation, wet oxidation and photocatalytic oxidation. Some analyzers use a combination or mixture of technology. (1)Combustion Oxidation/ NDIR Method (non-dispersive infrared gas analyzer) (2) WET OXIDATION- Persulfate oxidation / NDIR Method There are two types of this method, persulfate oxidation supported with UV (Ultraviolet) irradiation activation and heated persulfate oxidation. (3) CONDUCTIVITY- UV oxidation / Conductivity based TOC methods oxidize the TOC that is present to CO2 using UV radiation typically in the presence of a titanium oxide catalyst. COMBUSTION OXIDATION The combustion method measures total carbon (TC). It requires samples injection by syringe into a high temperature furnace with a platinum or cobalt catalyst. This process oxidizes all of the carbon materials present to CO2. For example, in one of these analyzers, TOC concentration is not directly measured; the Analyzer measures total carbon (TC) and total inorganic carbon (TIC) and subtracts TIC from TC to obtain TOC. An oxidizer and an acid are added to the sample. The acid reacts with bicarbonate and carbonate ions present in the sample to release carbon dioxide (CO 2 ). The CO 2 released from bicarbonate and carbonate ions represents the TIC in the sample. The sample is then subjected to ultra-violet (UV) radiation, which reacts with the oxidant and breaks down all remaining carbon bonds in the sample to release CO 2. The CO 2 released from both the acid reaction and the UV radiation represents all the carbon (TC) released from the sample. TOC is then obtained by subtracting TIC from TC. Newer methodology for TOC Analyses. One type of new methodology for TOC analyses is using closed-loop photocatalytic oxidation. The new TOC methodology includes a titanium dioxide slurry and a 400 nm light source for the oxidation process. The closed-loop TOC system incorporates a closedloop design to eliminate the need for carrier gases and uses what is called dynamic endpoint detection, where all of carbon in the sample is oxidized to completion. The reaction is measured using a non-dispersive infrared (NDIR) detector. This new technology can directly measure TOC from a single sample eliminating the loss of purgable organics and results in comparable recoveries of various organic compounds when compared to the combustion TOC method. This new methodology can be used for the same applications where the traditional TOC methods have been employed. There are now also Test N Tube reagents that can be used with COD digestors and

Spectrophotometer analyzer. The test is performed in two hours, but the cost for capital equipment is nowhere in the same range. The method involves the oxidation of sample carbon to carbon dioxide by persulfate digestion. The carbon dioxide diffuses into a colored ph indicator solution where it is converted to carbonic acid. The resulting color change is directly proportional to the concentration of carbon present in the sample. What is the meaning of C-BOD vs. BOD? There are too many terms and it is getting confusing to me..... There are two completely different tests-a C-BOD test and a BOD test. Many times a C- BOD vs. BOD5 test is needed due to conditions at a plant. In some places where the nitrification of ammonia may not be complete (i.e., incomplete conversion of ammonia (NH3) to nitrate (NO3)) or where too high levels of amines or ammonia are present, false BOD readings may occur. This can occur in municipal lagoons, wineries and general industry. For lagoon (pond) treatment systems or other situations where this may occur, it is recommended that a Carbonaceous Biochemical Oxygen Demand (CBOD or Inhibited BOD) should be reported and used in place of 5-day Biochemical Oxygen Demand (BOD5). Nitrification is inhibited so that only the oxidation of COD occurs. What is the difference between BOD vs. CBOD? BOD5 measures the oxidation of carbons and possibly nitrogenous compounds present in a water sample. CBOD only measures oxidation of carbons. Where did BOD5 come from? The BOD test Originated in the United Kingdom due to pollution in the Thames River. Legend has it that the 5-day BOD (Biological Oxygen Demand) test was developed in England. Sewage was dumped in a river and it took five days for it to reach the ocean, hence the five-day incubation requirement in the BOD method. It is rumored that a ferry tipped over and that many of the people who fell in the river got sick or died. This was not due to drowning, but due to the effects of the pollution in the river. The Royal Commission on Sewage Disposal recommended and adopted the BOD5 test in 1908. The duration of the test is normally 5 days. The Average temperature is = 20 degrees C. 300 ml are usually used. Dark Incubation is needed to restrict the growth of algae. The final measurement is usually expressed as O2 mg/l. BOD measures all biodegradable organic carbons, and under certain conditions, oxidizable nitrogen present in the waste. The biochemical oxygen demand (BOD) test tries to closely model an aerobic wastewater treatment system and the natural aquatic ecosystem. It measures oxygen taken up by the bacteria during the oxidation of organic matter. The test usually runs for a five-day period, but can run 7 or 10 days as well, depending on specific sample circumstances. BOD uses and limitations: BOD testing has its widest application in measuring waste loadings of treatment plants, and in evaluating the efficiency of treatment processes. It is of

limited use in industrial wastewaters containing heavy metal ions, cyanides, and other substances that may be toxic to the microorganisms. Unfortunately, the test has flaws. It is usually seeded with the type of bacteria found in municipal plants. The types of bacteria needed in wineries and general industry usually differ in species from the standard procedures method. The hard to degrade organics found in some of these systems also may take longer than 5 days to break down, so a BOD test will give an inaccurate measurement of the amount of pollution that may be present in a waste stream. Well, I guess it is really important to know these terms, how and where I sample my system as well as who runs the tests.... Heritage Systems Inc. 707-258-0553 www.heritagesystemsinc.com.............................