P5310, P5311 Low-Cost Programmable Transmitters with LHP Communication

Similar documents
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Technical Data. Dimensions

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive sensor NI10-M18-Y1X-H1141

T0118 T2118 T3118. Instruction Manual

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Capteur température et humidité pour HVAC

Instruction Manual. T3111 T3111L T3111P T3111Ex

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

J TB/TW Temperature limiter, temperature monitor

Temperature Transmitters ZTT series

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Rosemount 333 HART Tri-Loop

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Digital display DA 48

Rosemount 333 HART Tri-Loop

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Flow switches Series AD/VH

Technical Data. Dimensions

Features. Picture. Specifications

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Relative pressure transmitter type 520

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

How To Use A Ds340 (Dsp)

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

Software and Display instruments

Cable Plug acc. to DIN EN , Form A

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Power Supplies 3. SDN-P DIN Rail Series

Contents. Document information

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Telephone- and leased line modem for industrial applications TD-36

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Wahl C50 Calibrator FEATURES

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Duct Humidity Transmitter

3-phase, bidirectional energy meter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Vario-Series Accessories

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Plastic tube flowmeters Series PT/PS

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Technical Information RIA14

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

ACS-30-EU-EMDR-10-MOD

2.12. page Products for Explosion hazardous Environment

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Explosion proof enclosures

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

CAPACITIVE LEVEL METERS CLM 36

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

SINEAX U553 Transducer for AC Voltage

Differential Charge Amplifier

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Pressure transmitter For general industrial applications Model A-10

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Linear Luminaire with LED Series EXLUX 6402/2

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Rosemount 248 Temperature Transmitter

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Operating Instructions

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

PROCESS AUTOMATION MANUAL. Universal Temperature Converter. KFD2-UT2-(Ex)*(-1) ISO9001

Electric Rotary Actuator - On/Off or programmable control actuator

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Transcription:

JSP Industrial Controls Transmitters - KB0824EN - 2016/04 P5310, P5311 Low-Cost Programmable Transmitters with LHP Communication One type of transmitter for all common resistance and thermocouple sensors Linearized output signal 4 to 20 ma Accuracy from 0.1 % for ranges down to 1/5 of the basic range Span adjustability from 1 % to 100 % of the basic range Galvanic isolation of input from output 1000 V AC (P5311) Adjustability by program LHPWinConf and standard HART modem or by field configurator LHPConf (HARTConf) High immunity against interference (industrial environment) Intrinsically safe version II 1GD Application Transmitters P5310 and P5311 are used for conversion of a resistance or voltage temperature signal from a resistance or thermocouple temperature sensor to a linearized current loop output signal 4 to 20 ma. The transmitter type H1x is designed for installation into an industrial sensor head type A or B according to DIN 43729. Inputs and outputs of the transmitters type P5310 are not galvanic-isolated, these types are suitable for resistance temperature sensors and simple systems. The transmitters type P5311 includes galvanic isolation of inputs and outputs and are suitable for also in applications with many measuring points and for thermocouples. Description Input signal, switched over according to the input configuration are processed by an A/D transmitter and transformed into a digital signal that is transferred to a micro-computer; according to the preset configuration and after filtration of noise there are calculated all measured variables. These values are then used for calculation of the primary variable (temperature) and according to selected range, the output current is also calculated. One resistance sensor (two-, three- or four-wire) can be connected to the input. In case of a two-wire connection, entering of a constant value of the loop resistance compensation during configuration of the transmitter can compensate the resistance of input leads. In other cases, the leads resistance is compensated automatically. A thermocouple can be also connected to the input. Temperature of the thermocouple cold junction is compensated according to configuration, either by the inner sensor of terminal block temperature or by the entered constant temperature. The inner sensor guarantees maximum accuracy and stability of cold junction temperature measurement. If required, compensation using an external sensor can be configured as well. In addition to standard resistance sensors, there may be also processed signals of potentiometer positions that are measured in percents. One limit position is 0 % and the other is 100 %, independently on the value of the total resistance. In case there is necessary to measure position of the potentiometer as a resistance, there may be used the configuration for measurement of the resistance. Output of the transmitter is analogue signal of the current loop 4 to 20 ma. The current output can be also used for testing of the current loop and associated apparatus. Communication is used mostly for configuration of the transmitter and is not designed for distances over approx. 10 m. The transmitter can be set up using a manual configurator LHPConf (HARTConf) or a PC with the program LHPWinConf and HART modem HARTMod (MH-02) or equivalent communication interface. The transmitter communicates through an own protocol LHP that is partially compatible with the protocol HART, uses the same connection, however, communication is guaranteed only for short distances and there are implemented only few commands. This interface is designed for changes of configuration. Continuous communication may influence accuracy of measurement. JSP, s.r.o. PHONE / FAX JSP Slovakia s.r.o. PHONE / FAX Raisova 547 +420 493 760 811 jsp@jsp.cz Karloveská 63 +421 2 6030 1080 predaj@jsp.sk CZ-506 01 Jičín +420 493 760 820 www.jsp.cz SK-841 04 Bratislava +421 2 6030 1089 www.jsp.sk

Block diagram Technical specifications Supply voltage: P5310 9 to 35 V SS P5311 11 to 35 V SS Version EI1 11 to 30 V SS (internally protected against polarity inversion and shortterm overvoltage) Range of ambient temperatures: -40 to 85 C Reference ambient temperature: 23 ± 5 C Housing: Version H1x Version L1x Humidity: Version H1x Version L1x IP40, terminals IP00 after installation to the head the housing is given by the design of the head IP20 0 to 100 % RH with condensation after installation to the head 10 to 80 % RH without condensation Connection of wires: Screw terminals for cross section 0,5 to 1,5 mm 2, torque 0,5 Nm. Warm-up time: Time for re-programming of range using a PC: Time for re-programming of sensor type using a PC: 5 s Type of DIN rail: TS 35 according to DIN 46277 Dimensions (HxWxD): H1x L1x Material of cases: H1x L1x Weight: H1x, L1x Working position: Ø 44 x 24 mm 17.5 x 62.5 x 64 mm polycarbonate polyamide 40 g arbitrary 5 s 5 s Input Input ranges: Input type Basic range Standard RTD input 0 to 400 Ohm --- RTD input 0 to 4000 Ohm --- potentiometer 40 to 400 Ohm --- potentiometer 400 to 4000 Ohm --- voltage input -15 to 70 mv --- Pt100-200 to 850 C IEC 60751 Pt500-200 to 850 C IEC 60751 Pt1000-200 to 850 C IEC 60751 Ni100-60 to 250 C DIN 43760 Ni1000-60 to 250 C DIN 43760 thermocouple J -200 to 1200 C IEC 584-1 thermocouple K -200 to 1300 C IEC 584-1 thermocouple N -200 to 1300 C IEC 584-1 thermocouple R -50 to 1700 C IEC 584-1 thermocouple S -50 to 1700 C IEC 584-1 thermocouple T -250 to 400 C IEC 584-1 thermocouple B 100 to 1800 C* IEC 584-1 thermocouple E -200 to 950 C IEC 584-1 thermocouple L -200 to 900 C DIN 43710 thermocouple C 0 to 2300 C N.I.S.T. Monograph 175 *... range can be set from 0 C Digital accuracy: Range 0 to 400 Ohm mv ±0.1 % SR or ±0.08 Ohm Range 0 to 4000 Ohm ±0.1 % SR or ±0.8 Ohm Range -15 to 70 mv ±0.1 % SR or ±0.02 (the greatest value is valid; accuracy of measured value of digital output LHP)

Input signal: Resistance signal of temperature sensor or potentiometer, voltage signal of thermocouple Sensor connection: Resistance sensor Voltage sensor (TC) Potentiometer Compensation using an external sensor two-, three-, four-wire two-wire three-wire or four-wire two-wire Maximum wire resistance for resistance ranges: < 20 Ohm (each wire) Current through resistance sensor: < 0.15 ma Input overloading: Max. 24 VDC or max. 18 ma between any inputs (max. 60 s) Cold junction compensation error: < ±1 C Effect of wire resistance for resistance ranges: Two-wire connection can be compensated by constant value Three-wire connection no effect with identical values of wire resistance Four-wire connection no effect with specified wire resistance range Input resistance: Output Output signal: Two-wire 4 to 20 ma or 20 to 4 ma > 10 MOhm Total measurement error on the analogue output of P5310: Range 0 to 400 Ohm ±0.1 % SR or ±0.08 Ohm Range 0 to 4000 Ohm ±0.1 % SR or ±0.8 Ohm Range -15 to 70 mv ± 0.1 % SR or ±0.02 mv Range Pt100, Pt1000, Ni100, Ni1000 ±0.1 % SR or ±0.2 C Range Pt500 ±0.1 % SR or ±0.4 C Range TC J, K, T, E, L typ. ± 0.1 % SR or 0.5 C Range TC R, S, B, C typ. ± 0.1 % SR or 2 C Characteristics: Linear with temperature or linear with input quantity, other upon request Adjustability of the range: ±1 % to ±100 % of the input range Adjustability: Inside the input range (the given measurement errors apply for suppression of the beginning 100 % of the range) Time constant (95 %): Adjustable 0.5 to 60 s (2 measurements per second) Load resistance: R L [Ohm] (U N [V] - 9) / 0.022 Electric strength of galvanic isolation of P5311: 1000 VAC (test) Isolation resistance of galvanic isolation of P5311: Min. 100 MOhm Supplementary parameters Output current limitation: Signal 3.8 to 20.5 ma acc. to NAMUR NE43 Limitation of error current to approx. 22 ma Indication of sensor or transmitter error: Optionally by current > 21 ma or < 3.6 ma according to NAMUR NE43 Supply voltage effect: ±0.005 % / V Influence of ambient temperature changes: Range 0 to 400 Ohm ( ±0.1% SR or ±0.08 Ohm ) / 10 C Range 0 to 4000 Ohm ( ±0.1% SR or ±0.8 Ohm ) / 10 C Range -15 to 70 mv ( ±0.1% SR or ±0.02 mv ) / 10 C Long-term stability: ±0.1 % of the preset range per 2 years Electromagnetic compatibility: Radiation and immunity acc. to EN 61326-1 (Industrial environment) MV... measured value SR... span of preset range Total measurement error on the analogue output of P5311: Range 0 to 400 Ohm ±0.15 % SR or ±0.12 Ohm Range 0 to 4000 Ohm ±0.15 % SR or ±1.2 Ohm Range -15 to 70 mv ±0.15 % SR or ±0.03 mv corresponding temperature Range Pt100, Pt1000, Ni100, Ni1000 ±0.15 % SR or ± 0.3 C Range Pt500 ±0.15 % SR or ± 0.6 C Range TC J, K, T, E, L typ. ± 0.15 % SR or 0.5 C Range TC R, S, B, C typ. ± 0.15 % SR or 2 C

Dimensional drawings Version P531x H1x Version P531x L1x Electrical connection Version P531x H1x VOUTPUT Ý S T U P R L ~ 2 5 0 Oh m (p (for ro communication) ko m u n ika ci) LHP L H P ko m u n iká to r Communicator N APOWER P Á JE C Í SUPPLY Z D R O J R i T E S T 15 Oh m 3 w P O T Version P531x L1x R L ~ 2 5 0 Oh m (for (p ro communication) ko m u n ika ci) LHP L H P ko m u n iká to r Communicator VOUTPUT Ý S T U P N APOWER P Á JE C Í ZSUPPLY D R O J 5 6 R i T E S T 15 Oh m 7 8 1 2 1 2 1 2 ire 1 2 3 w P O T Numerals or letters may mark the terminals of the version P531x L1x: Numerals 1 2 5 6 7 8 Letters C D A B H G F E

Type Description P5310 Low-cost programmable transmitter with LHP protocol without galvanic isolation (accuracy 0,1 %) P5311 Low-cost programmable transmitter with LHP protocol with galvanic isolation (accuracy 0,15 %) Code Version H10 Into head B according to DIN, universal for resistance sensors and thermocouples H11 Into head B according to DIN, only for resistance sensors L10 On the rail TS 35, universal for resistance sensors and thermocouples L11 On the rail TS 35, only for resistance sensors Code Setting requirements NR Without requirements for the range and input setting (preset - Pt100, three-wire connection of sensor, 0 to 100 C) QR Range and other parameters setting according to configuration sheet DB2298 Code Calibration KPP5 Transmitter calibration in five points evenly distributed in setting range Kód Optional version EI1 Intrinsically safe version (Ex) II 1G Ex ia IIC T4-T6 Ga, (Ex) II 1D Ex ia IIIC T106 C Da (only for version P5311 H1x) EN2 Non-incendive design (Ex) II 3G Ex na IIC T4 Gc Code Optional accessories LHPWinCom Set of configuration program LHPWinConf (CZ+EN) for PC and modem HARTMod LHPConf HARTConf Field configurator for LHP transmitters, function of transmitter supply, without charging HART-USB modem and field communicator for LHP and HART transmitters, function of transmitter supply supplied from USB or inbuilt accumulator, charged from USB HARTMod Miniature HART modem with galvanic isolation USB-RS232C Communication interface for to USB port of the PC PT1000A Compensation resistor Pt1000 (-30 to +150 C) for external compensation of thermocouple S51 Box for wall mounting of one transmitter to explosive atmosphere (IP 68) (Ex) II 2G Ex d IIC T6, T5 Gb + (Ex) II 2D Ex t IIIC T50/60/80 C Db (2 cable glands KMEx have to be ordered) S52 Box for wall mounting of one transmitter with LED display to explosive atmosphere (IP 68) (Ex) II 2G Ex d IIC T6, T5 Gb + (Ex) II 2D Ex t IIIC T50/60/80 C Db (2 cable glands KMEx have to be ordered) S54 Wall mounted box (100x100x58 mm), housing IP 65 (for H1x versions, not for EI1, EN2) 1) S55 Wall mounted box (170x145x85 mm), housing IP 55 (for L1x versions, not for EI1, EN2) 2) S56 Wall mounted box (100x100x58 mm), housing IP 65 (for H1x versions, not for EI1, EN2) 3) VH1 Cap for head form B for transmitter mounting (for H1x versions) APT1 Adapter for flat head KME1 Cable outlet, nickel silver, Ex d, M20x1.5, IP 68, for fixed assembly cable with diameter 4 to 8.5 mm KME2 Cable outlet, nickel silver, Ex d, M20x1.5, IP 68, for fixed assembly cable with diameter 6 to 12 mm KME3 Cable outlet, stainless steel, Ex d, M20x1.5, IP 68, for fixed assembly cable with diameter 4 to 8 mm KME5 Cable outlet, polyamide, Ex ie, M20x1.5, IP 68, for fixed assembly cable with diameter 5 to 9 mm, operating temperature -20 to +95 C KME6 Cable outlet, polyamide, Ex ie, M20x1.5, IP 68, for fixed assembly cable with diameter 6.5 to 12 mm, operating temperature -20 to +95 C 3-year warranty Example of order: P5311 H11 QR For code QR configuration sheet DB2298 is required to the order.... Ex stock version... Marked version can be dispatched up to 5 working days (with calibration up to two weeks) 1) Possibility of installing one transmitter 2) Possibility of installing up to three transmitters 3) Possibility of installing two transmitters