Contents. I. Dantherm Product Index II. Understanding Dantherm Model Identification... 4

Similar documents
Panel Mounted Air Conditioners by Dantherm, Inc.

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Failure code manual. content

LOBOY 16 AIR CONDITIONERS

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

, User s Manual

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

FOXAIR 60/50 ALL MODELS

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

IV. Rear Mount System

NSN


Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

*.ppt 11/2/ :48 PM 1

MAC-120HE-01 Air-Cooled Chiller

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

USER S MANUAL HSC-24A

Explosion-Proof Electric Unit Heaters

Engineering Specifications

Specification Requirements DBL 700MX and 1000MX Series UPS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

TMS TANK MANAGEMENT SYSTEM

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Split System Cooling Product Data

MP-4000 Alarm List (Software version or later)

TC-9102 Series Surface Mount Temperature Controllers

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

WINDOW ROOM AIR CONDITIONER

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Chilled Water Precision Air Conditioner For Critical Application

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Split System Heat Pump Product Data

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

T-Series Air Conditioner T62 Model

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Commercial Refrigeration Temperature and Defrost Controls

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Low Profile Unit Cooler

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

ECOCIAT. Domestic hot water heat recovery unit

Single Phase Soft Starter

8146/5 Series Breaker Panelboards

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Model #: SMART2200CRMXL

catalog Single Package Vertical Air Conditioners and Heat Pumps

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Dehumidification Frequently Asked Questions

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

MAJORSINE Power Inverter

Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

T5000 T000 LCD Digital Fan Coil Thermostat

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

SWIMMING POOL HEAT PUMP

NetXtend Flex Series Integrated Outdoor Enclosure Solution. Outside Plant for Business-Critical Continuity

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Air Conditioning Sign-Off Sheet

Single Zone LCD Thermostat Operating Instructions

VLT Series 300 Watt True Sine Wave Inverter

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

SERVICE MANUAL REFRIGERATION

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

WE-350 Series ¼ Turn Electric Actuator

Air conditioning, electrical testing

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

PORTABLE AIR CONDITIONER

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

Electronic, Digital and Mechanical Vibration Switches

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Transcription:

Closed-Loop Cooling for Electronics & Communications Enclosures

Contents I. Dantherm Product Index... 3 II. Understanding Dantherm Model Identification... 4 III. Classic Series Air-Conditioners Classic 20 Air-conditioner 2,000 BTU / Hr... 5-9 Classic 30 Air-conditioner 4,000 BTU / Hr... 10-16 Classic 30 Air-conditioner 7,500 BTU / Hr... 10-16 Classic 47 Air-conditioner 10,000 BTU / Hr... 17-21 Classic 50 Air-conditioner 12,500 BTU / Hr... 22-27 Classic 50 Air-conditioner 13,000 BTU / Hr... 22-27 Classic 53 Air-conditioner 19,000 BTU / Hr... 28-32 Classic Top-Mount Air-Conditioners... 33-35 Class 1 Div 1 Hazardous Duty Air-Conditioner... 36 IV. Pinnacle Series Air-to-Air Heat Exchangers 23 Pinnacle Heat Exchanger 11 W / o F... 37-42 35 Pinnacle Heat Exchanger 15 W / o F... 37-42 35 Pinnacle Heat Exchanger 35 W / o F... 37-42 35 Pinnacle Heat Exchanger 45 W / o F... 37-42 35 Pinnacle Heat Exchanger 55 W / o F... 37-42 60 Pinnacle Heat Exchanger 100 W / o F... 37-42 V. Custom Products and Design Capabilities... 43 VI. Dantherm Technologies and Innovations & Summary... 44-46 Focus. Trust. Initiative. 2

Dantherm Standard Product Index Classic Series Air-Conditioners Product Model # Performance Voltages Refrigerant Classic 20 CS020020 2,000 BTU / Hr A, B5, B6 134a Classic 30 CS030040 4,000 BTU / Hr A, B 134a Classic 30 Classic 47 CS030075 (previously CS030060) CS047100 (previously CS047120) 7,500 BTU / Hr A, B5, B6 R-22 10,000 BTU / Hr B R-22 Classic 50 CS050125 12,500 BTU / Hr B R-22 Classic 50 CS050130 13,000 BTU / Hr B R-22 Classic 53 CS053190 19,000 BTU / Hr B 134a Rack/Top Mount CS012035 3,500 BTU / Hr A, B 134a Rack/Top Mount CS016055 5,500 BTU / Hr A, B R-22 A = 115V 1 Ph 50/60 Hz B = 208/ 230V 1 Ph 50/60 Hz B5 = 230V 1 Ph 50 Hz B6 = 230V 1 Ph 60 Hz Pinnacle Series Heat Exchangers Product Model # Performance Voltages Refrigerant 23" Pinnacle PS023011 11W / o F A, B, Z N/A Pinnacle 2" PS035015 15W / o F A, B, Z N/A Pinnacle 6" PS035035 35 W / o F A, B, Z N/A Pinnacle 6" PS035045 45 W / o F A, B, Z N/A Pinnacle 8" PS035055 55 W / o F A, B, Z N/A 60" Pinnacle PS060100 100 W / o F B N/A A = 115V 1 Ph 50/60 Hz B = Z = 230V 1 Ph 50/60 Hz 48V DC 3

Understanding Dantherm Model Identification Dantherm Classic Series Air-Conditioners C=Classic S= Standard Configuration X= Custom Configuration 030 = Height Of Unit 30 020 = 2000 BTU/Hr 040 = 4000 BTU/Hr 060 = 6000 BTU/Hr CS030040A-H004 Example Number Translation Classic 30 with Standard Construction 4,000 BTU/Hr 115 V 1Ph 50-60Hz Includes a 400 Watt Heater Option Option Codes H _ = Heater. Requires an additional 3 digits to refer to heater rating. ex: H004=400W A = 115Volt/1Ph/50-60 Hz B = 230Volt/1Ph/50-60Hz B5 = 220Volt/1Ph/50Hz B6 = 230V/1Ph/60Hz Z = 48v DC Dantherm Pinnacle Series Heat Exchangers P=Pinnacle S= Standard Configuration X= Custom Configuration 023 = Height Of Unit 23 011 = Watts per degree F 015 = Watts per degree F 035 = Watts per degree F 045 = Watts per degree F 055 = Watts per degree F 100 = Watts per degree F PS023011A-T1 Example Number Translation Pinnacle with Standard Construction 35 Watts per degree F 115V 1Ph 50-60Hz Includes a 400 Watt Heater Option Option Codes T= Thermostat GR = Designed for GR testing S = Speed Controller M= Stainless Steel Cover P= Cover Color option A = 115Volt/1Phase/50-60 Hz B = 230Volt/1Phase/50-60Hz Z = 48v DC 4

Dantherm CLASSIC 20 Air-Conditioner Model CS020020 2,000 BTU / Hr. DANTHERM S CLASSIC Line of Air-conditioners is specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Dantherm Part Number Product Description 2,000 BTU / Hr CS020020 A or B 115V or 230V 1 Ph, 50-60 Hz Dimensions: 20 H X 10 W X 9 D -H005 Optional: Integrated 500 Watt Heater Standard Features: Advanced Printed Circuit Control Board Built-in Lead Lag Controller Integral Return Air Thermostat Integrated Self Test Switch Infrared Diagnostic Connection Port Hot Spot Sensor Input Failure Alarm Output Variable Heating and Cooling Settings Condenser Fan on/off Controlled Coated Condenser Coil UL \ cul Recognized Outdoor Rated to UL 484-40 o F to +113 o F Operating Range High Pressure Switch Low Pressure Switch (inc. bypass timer) Low Ambient Operation Short Cycle Protection High Quality Powder-coated Cover 5

Dantherm CLASSIC 20 Air-Conditioner Dimensional Diagram Mounting Interface 6

Dantherm CLASSIC 20 Air-Conditioner Classic Air-flow Diagram Component Locations General Performance Data Dantherm Model BTU/Hr Watts Removal Voltage Hz Ph Full Load Amps Breaker / Fuse Size Approx Wt. lbs. / Kg. CS020020A 2,000 586 115V 50 / 60 1 8.0 15 55 / 25 CS020020B5 1,667 488 230V 50 1 3.5 10 55 / 25 CS020020B6 2,000 586 230V 60 1 4.0 10 55 / 25 Capacity ratings shown above are based on 95 o F (35 o C) return air temperature to cabinet in 95 o F (35 o C) ambient conditions at nominal voltage and unimpeded resistance to air flow. 7

Dantherm CLASSIC 20 Air-Conditioner ACG2 Controller LED Trip Indicator Microprocessor Infra-Red LED Alarm Contacts Self-Test Button Cooling Dial Settings from 68 F (20 C) to 104 F (40 C) Heating Dial Settings from 41 F (5 C) to 59 F (15 C) ACG2 Self-Test Button Function A self-test button is provided on the control board of each Classic panel-mount air-conditioner. Simply pressing and holding this button for 6 seconds will activate the self-test sequence as shown in the chart below. During this test, the installer or technician may observe the air-conditioner for the expected function and duration, indicating that all are operating properly. On completion of the self-test, the air-conditioner automatically returns to normal running condition. The control board is also outfitted with an Infrared LED diagnostic port. Optional software and an infrared / RS232 Interface cable are available from Dantherm, enabling the unit to be connected to a portable laptop computer. In this manner, comprehensive and detailed real-time operational data may be observed, diagnostics run, and data imported onto the laptop. Call for more details. Sequence Description Evaporator Fan Heater Compressor Condenser Fan Duration 1 Internal Fan only ON OFF OFF OFF 30 Seconds 2 Heater ON ON OFF OFF 35 Seconds 3 Internal Fan only ON OFF OFF OFF 20 Seconds 4 Compressor & Condenser fan ON OFF ON ON 75 Seconds 5 Internal Fan only ON OFF OFF OFF 30 Seconds 8

Dantherm CLASSIC 20 Air-Conditioner Alarm Capabilities All Dantherm Classic units have built-in alarm capabilities programmed into the control board. Failure Modes The following conditions will activate the failure alarm output on terminals 7 and 8: Loss of supply voltage Low Pressure (< 10 psi for 300 seconds) High Pressure (> 400 / 500 psi) Low or no current to compressor (less than 1 amp) High Return Air Temperature (18 o F / 10 o C higher than cooling set point) Low Return Air Temperature (9 o F / 5 o C lower than heater set point) Alarm Connections The alarm cable consists of four wires: Black wire: connected to terminal 7 on the control board Red wire: connected to terminal 8 on the control board White wire: not used Green wire: not used Alarm Description Only the red and black wires are used and are connected to terminals 7 and 8 of the control board. Terminals 7 and 8 operate as a normally closed contactor and open upon failure. During normal operation, a relay is energized, providing continuity between terminals 7 and 8. When a failure is detected, the relay is deenergized such that there is no continuity between terminals 7 and 8. A low voltage signal (up to 50V DC and 0.1 amps) may be connected to the contactors for external alarm capabilities. Performance Curves 9

Dantherm CLASSIC 30 Air-Conditioners Model CS030040 4,000 BTU / Hr. and Model CS030075 7,500 BTU / Hr. DANTHERM S CLASSIC Line of Air-conditioners is specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Dantherm Part Number Product Description 4,000 BTU / Hr CS030040 A or B 115V or 230V 1 Ph, 50-60 Hz Dimensions: 30 H X 19 W X 9 D 7,500 BTU / Hr CS030075 A or B 115V or 230V 1 Ph, 50-60 Hz Dimensions: 30 H X 19 W X 11 D -H004 Optional: Integrated 400 Watt Heater -H008 Optional: Integrated 800 Watt Heater -H012 Optional: Integrated 1200 Watt Heater 10

Dantherm CLASSIC 30 Air-Conditioners Standard Features: Advanced Printed Circuit Control Board Built-in Lead Lag Controller Integral Return Air Thermostat Integrated Self Test Switch Infrared Diagnostic Connection Port Hot Spot Sensor Input Failure Alarm Output Variable Heating and Cooling Settings Condenser Fan on/off Controlled Coated Condenser Coil UL \ cul Recognized Outdoor Rated to UL 484-40 o F to +131 o F Operating Range High Pressure Switch Low Pressure Switch (inc. bypass timer) Low Ambient Operation Short Cycle Protection Options for GR-487-CORE modifications High Quality Powder-coated Cover Classic Air-flow Diagram Inside View 11

Dantherm CLASSIC 30 Air-Conditioner General Performance Data Dantherm Model BTU/Hr Watts Removal Voltage Hz Ph Full Load Amps Breaker / Fuse Size Approx Wt. lbs. / Kg. CS030040A 4,000 1,172 115V 50 / 60 1 12.2 25 100 / 45 CS030040B 4,000 1,172 230V 50 / 60 1 6.7 15 100 / 45 CS030075A 7,500 2,196 115V 50 / 60 1 9.5 20 105 / 48 CS030075B 7,500 2,196 230V 50 / 60 1 5.0 10 105 / 48 Capacity ratings shown above are based on 95 o F (35 o C) return air temperature to cabinet in 95 o F (35 o C) ambient conditions at nominal voltage and unimpeded resistance to air flow. ACG2 Controller LED Trip Indicator Microprocessor Infra-Red LED Alarm Contacts Self-Test Button Cooling Dial Settings from 68 F (20 C) to 104 F (40 C) Heating Dial Settings from 41 F (5 C) to 59 F (15 C) 12

Dantherm CLASSIC 30 Air-Conditioner ACG2 Self-Test Button Function A self-test button is provided on the control board of each Classic panel-mount air-conditioner. Simply pressing and holding this button for 6 seconds will activate the self-test sequence as shown in the chart below. During this test, the installer or technician may observe the air-conditioner for the expected function and duration, indicating that all are operating properly. On completion of the self-test, the air-conditioner automatically returns to normal running condition. The control board is also outfitted with an Infrared LED diagnostic port. Optional software and an infrared / RS232 Interface cable are available from Dantherm, enabling the unit to be connected to a portable laptop computer. In this manner, comprehensive and detailed real-time operational data may be observed, diagnostics run, and data imported onto the laptop. Call for more details. Sequence Description Evaporator Fan Heater Compressor Condenser Fan Duration 1 Internal Fan only ON OFF OFF OFF 30 Seconds 2 Heater ON ON OFF OFF 35 Seconds 3 Internal Fan only ON OFF OFF OFF 20 Seconds 4 Compressor & Condenser fan ON OFF ON ON 75 Seconds 5 Internal Fan only ON OFF OFF OFF 30 Seconds Alarm Capabilities All Dantherm Classic units have built-in alarm capabilities programmed into the control board. Failure Modes The following conditions will activate the failure alarm output on terminals 7 and 8: Loss of supply voltage Low Pressure (< 10 psi for 300 seconds) High Pressure (> 400 / 500 psi) Low or no current to compressor (less than 1 amp) High Return Air Temperature (18 o F / 10 o C higher than cooling set point) Low Return Air Temperature (9 o F / 5 o C lower than heater set point) Alarm Connections The alarm cable consists of four wires: Black wire: connected to terminal 7 on the control board Red wire: connected to terminal 8 on the control board White wire: not used Green wire: not used Alarm Description Only the red and black wires are used and are connected to terminals 7 and 8 of the control board. Terminals 7 and 8 operate as a normally closed contactor and open upon failure. During normal operation, a relay is energized, providing continuity between terminals 7 and 8. When a failure is detected, the relay is deenergized such that there is no continuity between terminals 7 and 8. A low voltage signal (up to 50V DC and 0.1 amps) may be connected to the contactors for external alarm capabilities. 13

Dantherm CLASSIC 30 Air-Conditioner Dimensional Diagram Mounting Interface 4,000 BTU CLASSIC 30 Air-Conditioner **Mounting pattern for GR version only, call or email to request the standard version. 14

Dantherm CLASSIC 30 Air-Conditioner Dimensional Diagram Mounting Interface 7,500 BTU CLASSIC 30 Air-Conditioner 15

Dantherm CLASSIC 30 Air-Conditioner Performance Curves 4,000 BTU CLASSIC 30 Air-Conditioner 7, 500 BTU CLASSIC 30 Air- Conditioner 16

Dantherm CLASSIC 47 Air-Conditioner Model CS047100B 10,000 BTU / Hr. DANTHERM S CLASSIC Line of Air-conditioners is specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Dantherm Part Number Product Description 10,000 BTU / Hr CS047100B 230V 1 Ph, 50-60 Hz Dimensions: 47 H X 19 W X 12 D -H008, H012, H015, H030 Optional: Integrated 800W, 1200W, or 1500W Heater Standard Features: Advanced Printed Circuit Control Board Built-in Lead Lag Controller Integral Return Air Thermostat Integrated Self Test Switch Infrared Diagnostic Connection Port Hot Spot Sensor Input Failure Alarm Output Variable Heating and Cooling Settings Condenser Fan on/off Controlled Coated Condenser Coil UL \ cul Recognized Outdoor Rated to UL 484-40 o F to +131 o F Operating Range High Pressure Switch Low Pressure Switch (inc. bypass timer) Low Ambient Operation Short Cycle Protection Options for GR-487-CORE modifications High Quality Powder-coated Cover 17

Dantherm CLASSIC 47 Air-Conditioner CLASSIC Air-Flow Diagram Dimensional Diagram Mounting Interface 10,000 BTU CLASSIC 47 Air-Conditioner 18

Dantherm CLASSIC 47 Air-Conditioner General Performance Data Dantherm Model BTU/Hr Watts Removal Voltage Hz Ph Full Load Amps Breaker / Fuse Size Approx Wt. lbs. / Kg. CS047100B 10,000 3,516 230V 60 1 9.0 15 154 / 70 CS047100B 9,000 2,930 208V 50 1 8.8 15 154 / 70 Capacity ratings shown above are based on 95 o F (35 o C) return air temperature to cabinet in 95 o F (35 o C) ambient conditions at nominal voltage and unimpeded resistance to air flow. ACG2 Controller LED Trip Indicator Microprocessor Infra-Red LED Alarm Contacts Self-Test Button Cooling Dial Settings from 68 F (20 C) to 104 F (40 C) Heating Dial Settings from 41 F (5 C) to 59 F (15 C) 19

Dantherm CLASSIC 47 Air-Conditioner ACG2 Self-Test Button Function A self-test button is provided on the control board of each Classic panel-mount air-conditioner. Simply pressing and holding this button for 6 seconds will activate the self-test sequence as shown in the chart below. During this test, the installer or technician may observe the air-conditioner for the expected function and duration, indicating that all are operating properly. On completion of the self-test, the air-conditioner automatically returns to normal running condition. The control board is also outfitted with an Infrared LED diagnostic port. Optional software and an infrared / RS232 Interface cable are available from Dantherm, enabling the unit to be connected to a portable laptop computer. In this manner, comprehensive and detailed real-time operational data may be observed, diagnostics run, and data imported onto the laptop. Call for more details. Sequence Description Evaporator Fan Heater Compressor Condenser Fan Duration 1 Internal Fan only ON OFF OFF OFF 30 Seconds 2 Heater ON ON OFF OFF 35 Seconds 3 Internal Fan only ON OFF OFF OFF 20 Seconds 4 Compressor & Condenser fan ON OFF ON ON 75 Seconds 5 Internal Fan only ON OFF OFF OFF 30 Seconds Alarm Capabilities All Dantherm Classic units have built-in alarm capabilities programmed into the control board. Failure Modes The following conditions will activate the failure alarm output on terminals 7 and 8: Loss of supply voltage Low Pressure (< 10 psi for 300 seconds) High Pressure (> 400 / 500 psi) Low or no current to compressor (less than 1 amp) High Return Air Temperature (18 o F / 10 o C higher than cooling set point) Low Return Air Temperature (9 o F / 5 o C lower than heater set point) Alarm Connections The alarm cable consists of four wires: Black wire: connected to terminal 7 on the control board Red wire: connected to terminal 8 on the control board White wire: not used Green wire: not used Alarm Description Only the red and black wires are used and are connected to terminals 7 and 8 of the control board. Terminals 7 and 8 operate as a normally closed contactor and open upon failure. During normal operation, a relay is energized, providing continuity between terminals 7 and 8. When a failure is detected, the relay is deenergized such that there is no continuity between terminals 7 and 8. A low voltage signal (up to 50V DC and 0.1 amps) may be connected to the contactors for external alarm capabilities. 20

Dantherm CLASSIC 47 Air-Conditioner Performance Curves 21

Dantherm CLASSIC 50 Air-Conditioner Model CS050125B 12,500 BTU / Hr. and Model CS050130B 13,000 BTU / Hr. DANTHERM S CLASSIC Line of Air-conditioners is specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Dantherm Part Number Product Description 12,500 BTU / Hr CS050125B 230V 1 Ph, 50-60 Hz Dimensions: 50 H X 19 W X 15 D -H015 or -H030 Optional: 1500W or 3000W Heater 13,000 BTU / Hr CS050130B 230V 1 Ph, 50-60 Hz Dimensions: 50 H X 19 W X 13 D -H015 or -H030 Optional: 1500W or 3000W Heater 22

Dantherm CLASSIC 50 Air-Conditioner Standard Features: Advanced Printed Circuit Control Board Built-in Lead Lag Controller Integral Return Air Thermostat Integrated Self Test Switch Infrared Diagnostic Connection Port Hot Spot Sensor Input Failure Alarm Output Variable Heating and Cooling Settings Condenser Fan on/off Controlled Coated Condenser Coil UL \ cul Recognized Outdoor Rated to UL 484-40 o F to +131 o F Operating Range High Pressure Switch Low Pressure Switch (inc. bypass timer) Low Ambient Operation Short Cycle Protection Options for GR-487-CORE modifications High Quality Powder-coated Cover CLASSIC Air-Flow Diagram 23

Dantherm CLASSIC 50 Air-Conditioner General Performance Data Dantherm Model BTU/Hr Watts Removal Voltage Hz Ph Full Load Amps Breaker / Fuse Size Approx Wt. lbs. / Kg. CS050125B 12,500 3,663 230V 50 / 60 1 9.0 *15 / 20 154 / 70 CS050130B 13,000 3,809 230V 50 / 60 1 9.0 *15 / 20 154 / 70 Capacity ratings shown above are based on 131 o F (55 o C) return air temperature to cabinet in 131 o F (55 o C) ambient conditions at nominal voltage and unimpeded resistance to air flow. * NOTE: Breaker / Fuse requirement with no heater and 1500W heater: 15 amp. Breaker / Fuse requirement with 3000W heater: 20 amp. ACG2 Controller LED Trip Indicator Microprocessor Infra-Red LED Alarm Contacts Self-Test Button Cooling Dial Settings from 68 F (20 C) to 104 F (40 C) Heating Dial Settings from 41 F (5 C) to 59 F (15 C) 24

Dantherm CLASSIC 50 Air-Conditioner ACG2 Self-Test Button Function A self-test button is provided on the control board of each Classic panel-mount air-conditioner. Simply pressing and holding this button for 6 seconds will activate the self-test sequence as shown in the chart below. During this test, the installer or technician may observe the air-conditioner for the expected function and duration, indicating that all are operating properly. On completion of the self-test, the air-conditioner automatically returns to normal running condition. The control board is also outfitted with an Infrared LED diagnostic port. Optional software and an infrared / RS232 Interface cable are available from Dantherm, enabling the unit to be connected to a portable laptop computer. In this manner, comprehensive and detailed real-time operational data may be observed, diagnostics run, and data imported onto the laptop. Call for more details. Sequence Description Evaporator Fan Heater Compressor Condenser Fan Duration 1 Internal Fan only ON OFF OFF OFF 30 Seconds 2 Heater ON ON OFF OFF 35 Seconds 3 Internal Fan only ON OFF OFF OFF 20 Seconds 4 Compressor & Condenser fan ON OFF ON ON 75 Seconds 5 Internal Fan only ON OFF OFF OFF 30 Seconds Alarm Capabilities All Dantherm Classic units have built-in alarm capabilities programmed into the control board. Failure Modes The following conditions will activate the failure alarm output on terminals 7 and 8: Loss of supply voltage Low Pressure (< 10 psi for 300 seconds) High Pressure (> 400 / 500 psi) Low or no current to compressor (less than 1 amp) High Return Air Temperature (18 o F / 10 o C higher than cooling set point) Low Return Air Temperature (9 o F / 5 o C lower than heater set point) Alarm Connections The alarm cable consists of four wires: Black wire: connected to terminal 7 on the control board Red wire: connected to terminal 8 on the control board White wire: not used Green wire: not used Alarm Description Only the red and black wires are used and are connected to terminals 7 and 8 of the control board. Terminals 7 and 8 operate as a normally closed contactor and open upon failure. During normal operation, a relay is energized, providing continuity between terminals 7 and 8. When a failure is detected, the relay is deenergized such that there is no continuity between terminals 7 and 8. A low voltage signal (up to 50V DC and 0.1 amps) may be connected to the contactors for external alarm capabilities. 25

Dantherm CLASSIC 50 Air-Conditioner Dimensional Diagram Mounting Interface 12,500 BTU CLASSIC 50 Air-Conditioner 13,000 BTU CLASSIC 50 Air-Conditioner 26

Dantherm CLASSIC 50 Air-Conditioner Performance Curves 13,000 BTU CLASSIC 50 Air-Conditioner 27

Dantherm CLASSIC 53 Air-Conditioner Model CS053190B 19,000 BTU / Hr. DANTHERM S CLASSIC Line of Air-conditioners is specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Dantherm Part Number Product Description 19,000 BTU / Hr CS053190B 230V 1 Ph, 60 Hz Dimensions: 53 H X 23 W X 16.5 D -H030 3000W Heater Standard Features: Advanced Printed Circuit Control Board Built-in Lead Lag Controller Integral Return Air Thermostat Integrated Self Test Switch Infrared Diagnostic Connection Port Hot Spot Sensor Input Failure Alarm Output Variable Heating and Cooling Settings Condenser Fan on/off Controlled Coated Condenser Coil UL \ cul Recognized Outdoor Rated to UL 484-40 o F to +131 o F Operating Range High Pressure Switch Low Pressure Switch (inc. bypass timer) Low Ambient Operation Short Cycle Protection Options for GR-487-CORE modifications High Quality Powder-coated Cover 28

Dantherm CLASSIC 53 Air-Conditioner CLASSIC Air-Flow Diagram Dimensional Diagram Mounting Interface 29

Dantherm CLASSIC 53 Air-Conditioner Dantherm Model BTU/Hr Watts Removal Voltage Hz Ph Full Load Amps Breaker / Fuse Size Approx Wt. lbs. / Kg. CS053190B 19,000 5,787 230V 60 1 TBC 20 250/113 Capacity ratings shown above are based on 131 o F (55 o C) return air temperature to cabinet in 131 o F (55 o C) ambient conditions at nominal voltage and unimpeded resistance to air flow. ACG2 Controller LED Trip Indicator Microprocessor Infra-Red LED Alarm Contacts Self-Test Button Cooling Dial Settings from 68 F (20 C) to 104 F (40 C) Heating Dial Settings from 41 F (5 C) to 59 F (15 C) 30

Dantherm CLASSIC 53 Air-Conditioner ACG2 Self-Test Button Function A self-test button is provided on the control board of each Classic panel-mount air-conditioner. Simply pressing and holding this button for 6 seconds will activate the self-test sequence as shown in the chart below. During this test, the installer or technician may observe the air-conditioner for the expected function and duration, indicating that all are operating properly. On completion of the self-test, the air-conditioner automatically returns to normal running condition. The control board is also outfitted with an Infrared LED diagnostic port. Optional software and an infrared / RS232 Interface cable are available from Dantherm, enabling the unit to be connected to a portable laptop computer. In this manner, comprehensive and detailed real-time operational data may be observed, diagnostics run, and data imported onto the laptop. Call for more details. Sequence Description Evaporator Fan Heater Compressor Condenser Fan Duration 1 Internal Fan only ON OFF OFF OFF 30 Seconds 2 Heater ON ON OFF OFF 35 Seconds 3 Internal Fan only ON OFF OFF OFF 20 Seconds 4 Compressor & Condenser fan ON OFF ON ON 75 Seconds 5 Internal Fan only ON OFF OFF OFF 30 Seconds Alarm Capabilities All Dantherm Classic units have built-in alarm capabilities programmed into the control board. Failure Modes The following conditions will activate the failure alarm output on terminals 7 and 8: Loss of supply voltage Low Pressure (< 10 psi for 300 seconds) High Pressure (> 400 / 500 psi) Low or no current to compressor (less than 1 amp) High Return Air Temperature (18 o F / 10 o C higher than cooling set point) Low Return Air Temperature (9 o F / 5 o C lower than heater set point) Alarm Connections The alarm cable consists of four wires: Black wire: connected to terminal 7 on the control board Red wire: connected to terminal 8 on the control board White wire: not used Green wire: not used Alarm Description Only the red and black wires are used and are connected to terminals 7 and 8 of the control board. Terminals 7 and 8 operate as a normally closed contactor and open upon failure. During normal operation, a relay is energized, providing continuity between terminals 7 and 8. When a failure is detected, the relay is deenergized such that there is no continuity between terminals 7 and 8. A low voltage signal (up to 50V DC and 0.1 amps) may be connected to the contactors for external alarm capabilities. 31

Dantherm CLASSIC 53 Air-Conditioner Performance Curves 19,000 BTU CLASSIC 53 Air-Conditioner Capacity Curve 19K - November 30, 2007 25000 20000 Load Btu/hr 15000 10000 35ºC Ambient 45ºC Ambient 55ºC Ambient 5000 0 0 10 20 30 40 50 60 Internal Temperature (Return) ºC 32

Dantherm CLASSIC Top-Mount Air-Conditioner Model CS012035 3,500 BTU / Hr. Model CS016055 5,500 BTU / Hr. DANTHERM S CLASSIC Line of Air-conditioners is specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Dantherm Part Number CS012035 A or B CS016055 A or B Product Description 3,500 BTU / Hr 115V or 230V 1 Ph, 50-60 Hz Dimensions: 12-1/4 H X 17-1/4 W X 22 D 5,500 BTU / Hr 115V or 230V 1 Ph, 50-60 Hz Dimensions: 16-1/4 H X 17-1/4 W X 22 D -H004 or -H008 Optional: Integrated 400W or 800W Heater 33

Dantherm CLASSIC Top-Mount Air-Conditioner General Performance Data Dantherm Model BTU/Hr Watts Removal Voltage Hz Ph Full Load Amps Breaker / Fuse Size Approx Wt. lbs. / Kg. CS012035A 3,500 1025 115V 50 / 60 1 13.2 20 127 / 58 CS012035B 3,500 1025 230V 50 / 60 1 6.0 10 127 / 58 CS016055A 5,500 1610 115V 50 / 60 1 13.0 20 143 / 65 CS016055B 5,500 1610 230V 50 / 60 1 6.2 10 143 / 65 Capacity ratings shown above are based on 95 o F (35 o C) return air temperature to cabinet in 95 o F (35 o C) ambient conditions at nominal voltage and unimpeded resistance to air flow. Standard Features Closed Loop Cooling Rated for Outdoor Use to UL 484-40 o F to +131 o F Operating Range High Pressure Switch Low Pressure Switch (inc. bypass timer) Low Ambient Operation Condensation Removal System Short Cycle Protection High Performance Fans UL \ cul Recognized High Quality Powder-coated Cover Product Diagram Component Locations 34

Dantherm CLASSIC Top-Mount Air-Conditioner Dimensional Diagram Mounting Interface Classic Top-Mount Air-flow Diagram Introducing. 35

Hazardous Duty Cooling At Its Best Completely New Design for explosive environments Cooling unit specifically designed for Class 1, Division 1 hazardous locations All electrical components / connections located on internal loop Operational capacity of 10,000 BTU / hr Available in 480-Volt and 230-Volt 1 Phase High and low pressure switches w/ Lock-out Relay Compressor overload protection w/ Lock-out Relay No electronic controls. simple on / off control Operational temperature up to 131 o F Efficient Rotary Compressor Low ambient control Ambient air filter Alarm output 36

Pinnacle Series Air-to-Air Heat Exchangers * Efficient COOLING for indoor & outdoor electronics cabinets & enclosures * DANTHERM S PINNACLE Heat Exchangers are specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Quality Efficiency Durability Versatility Simplicity Available in 48V DC and 115V and 230V AC Voltages. Closed-loop cooling removes heat and protects electronics from humidity & contaminants. Options for GR-487-CORE compliance for corrosion resistance and wind-driven rain. Compact design allows for wide variety of mounting configurations and applications. Units mount quickly and easily to outside of cabinet or enclosure. Longest standard warrantee in the industry at 18 months. UL Recognized or Listed to UL 484 for outdoor use. Optional temperature control and alarm strategies. Units are manufactured here in the United States. Efficient coated aluminum heat-transfer core. Low maintenance; CFC and refrigerant free. 37

Pinnacle Series Air-to-Air Heat Exchangers Every Pinnacle Series Heat Exchanger incorporates an efficient and durable epoxy-coated aluminum heat-transfer core manufactured on state-of-the-art equipment exclusive to Dantherm. General Performance Data Model Number Voltage Performance in Watts / o F Performance in Watts / o C Dimensions Full Load Amps. Breaker / Fuse Weight (lbs.) PS023011A 115V AC 11 20 23"H x 12"W x 5"D 0.5 0.75 21 PS023011B 230V AC 11 20 23"H x 12"W x 5"D 0.3 0.5 21 PS023011Z 48V DC 11 20 23"H x 12"W x 5"D 1.0 1.5 21 PS035015A 115V AC 15 27 36"H x 18"W x 3.6"D 1.1 3 37 PS035015B 230V AC 15 27 36"H x 18"W x 3.6"D 0.87 2 37 PS035015Z 48V DC 15 27 36"H x 18"W x 3.6"D 0.84 2 37 PS035035A 115V AC 35 63 36"H x 18"W x 6.8"D 1.7 6 59 PS035035B 230V AC 35 63 36"H x 18"W x 6.8"D 0.86 3 59 PS035035Z 48V DC 35 63 36"H x 18"W x 6.8"D 3.96 9 59 PS035045A 115V AC 45 81 36"H x 18"W x 6.8"D 3.4 5 60 PS035045B 230V AC 45 81 36"H x 18"W x 6.8"D 1.86 2 60 PS035045Z 48V DC 45 81 36"H x 18"W x 6.8"D 5.1 6 60 PS035055A 115V AC 55 99 36"H x 18"W x 8.8"D 3.4 5 70 PS035055B 230V AC 55 99 36"H x 18"W x 8.8"D 1.86 2 70 PS035055Z 48V DC 55 99 36"H x 18"W x 8.8"D 5.12 6 70 PS060100B 230V AC 100 180 60"H x 24W" x 14"D 1.0 3 135 38

Pinnacle Series Air-to-Air Heat Exchangers Dimensional Diagrams Mounting Interfaces Pinnacle PS023011 Models Pinnacle Series Air-to-Air Heat Exchangers 39

Pinnacle Series Air-to-Air Heat Exchangers Dimensional Diagrams Mounting Interfaces Pinnacle PS0350XX Models Pinnacle PS060100B Model 40

Pinnacle Series Air-to-Air Heat Exchangers Dimensional Diagrams Mounting Interfaces Pinnacle PS060100 Models 41

Pinnacle Series Air-to-Air Heat Exchangers Heat Exchanger Performance Curves 4500 4000 3500 Total Heat Dissipation (Watts) 3000 2500 2000 1500 1000 500 0 0 5 10 15 20 25 30 35 40 Temperature Delta in 0 F PS023011 PS035015 PS035035 PS035045 PS035055 PS060100 42

Dantherm Custom Products Air-Conditioners & Heat Exchangers Ask about Dantherm Global Design Capabilities 43

Introducing. Dantherm New Technologies & Innovations Plastic Foil Heat Exchanger Solutions Improved fuel cell technologies Pressurized ventilation systems Others in development 44

Global Expertise, Resources, and Capabilities. Local Commitment to Quality Products and Exceptional Customer Service. Focus. Trust. Initiative. 45

For Personal Assistance or Ordering: The information contained in this document is subject to change without notification. For personal assistance in product sizing, pricing, or model selection, call, fax, or email your questions, specifications, or requirements to: Dantherm Contact Responsibility Title Direct Phone Email Address Rick Gromlovits Commercial Sales Manager Electronics Cooling (704) 574-9541 rick.gromlovits@dantherm.com Rick Schmidt Technical Engineering Manager (864) 699-1066 rick.schmidt@dantherm.com Lourdes Sisk Customer Service & Marketing Customer Service (864) 699-1058 & Marketing lourdes.sisk@dantherm.com Manager Dantherm Air Handling, Inc. 4260 Orchard Park Blvd. Spartanburg, SC 29303 Phone: (864) 595-9800 Fax: (864) 595-9810 www.dantherm-air-handling.com sales.usa@dantherm.com 46