STUDY, BEHAVIOUR AND COMPARISON OF BASE ISOLATED STEEL- CONCRETE-COMPOSITE STRUCTURES BY RESPONSE SPECTRUM ANALYSIS

Similar documents
Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

EFFECT OF POSITIONING OF RC SHEAR WALLS OF DIFFERENT SHAPES ON SEISMIC PERFORMANCE OF BUILDING RESTING ON SLOPING GROUND

SEISMIC ANALYSIS AND RETROFITTING OF R.C.C STRUCTURE

SEISMIC RETROFITTING OF STRUCTURES

DEVELOPMENT AND APPLICATIONS OF TUNED/HYBRID MASS DAMPERS USING MULTI-STAGE RUBBER BEARINGS FOR VIBRATION CONTROL OF STRUCTURES

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

OPTIMAL DIAGRID ANGLE TO MINIMIZE DRIFT IN HIGH-RISE STEEL BUILDINGS SUBJECTED TO WIND LOADS

Methods for Seismic Retrofitting of Structures

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

Performance-based Evaluation of the Seismic Response of Bridges with Foundations Designed to Uplift

Seismic Risk Prioritization of RC Public Buildings

Rehabilitation of a 1985 Steel Moment- Frame Building

Seismic performance evaluation of an existing school building in Turkey

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

Optimum proportions for the design of suspension bridge

DESIGN SPECIFICATIONS FOR HIGHWAY BRIDGES PART V SEISMIC DESIGN

DYNAMIC ANALYSIS ON STEEL FIBRE

Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories

Figure Test set-up

Effect of Container Height on Base Shear of Elevated Water Tank

PERFORMANCE BASED SEISMIC EVALUATION AND RETROFITTING OF UNSYMMETRICAL MEDIUM RISE BUILDINGS- A CASE STUDY

Seismic Risk Evaluation of a Building Stock and Retrofit Prioritization

CH. 2 LOADS ON BUILDINGS

The International Journal Of Science & Technoledge (ISSN X)

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Seismic Isolated Hospital Design Practice in Turkey: Erzurum Medical Campus

Numerical modelling of shear connection between concrete slab and sheeting deck

SEISMIC APPROACH DESIGN COMPARISON BETWEEN

DISASTER RESISTANCE EARTHQUAKES AND STRUCTURES

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

Seismic Isolation Retrofitting of Japanese Wooden Buildings

Specification for Structures to be Built in Disaster Areas

SEISMIC RETROFITTING OF REINFORCED CONCRETE BUILDINGS USING TRADITIONAL AND INNOVATIVE TECHNIQUES

bi directional loading). Prototype ten story

Dynamic Behaviour of Reinforced Concrete Frames Designed with Direct Displacement-Based Design

MODELLING OF AN INFILL WALL FOR THE ANALYSIS OF A BUILDING FRAME SUBJECTED TO LATERAL FORCE

Vibration Isolation in Data Centers

DESIGN AND ANALYSIS OF BRIDGE WITH TWO ENDS FIXED ON VERTICAL WALL USING FINITE ELEMENT ANALYSIS

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

SEISMIC DESIGN OF TWO STOREY REINFORCED CONCRETE BUILDING IN MALAYSIA WITH LOW CLASS DUCTILITY

Reinforced Concrete Design

Seismic Evaluation and Retrofitting of RC Building by Using Energy Dissipating Devices

Uniaxial Compressive Strength of Cold-formed Steel Tubular Sections with Recycled Aggregate Concrete Infill

8.2 Elastic Strain Energy

EXAMPLES OF SEISMIC RETROFITTING IN JAPAN

RECOMMENDATIONS FOR THE DESIGN AND CONSTRUCTION OF BASE ISOLATED STRUCTURES

ANALYSIS AND DESIGN OF RC TALL BUILDING SUBJECTED TO WIND AND EARTHQUAKE LOADS

METHODS FOR ACHIEVEMENT UNIFORM STRESSES DISTRIBUTION UNDER THE FOUNDATION

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

SEISMIC DESIGN OF MULTI-STORY BUILDINGS WITH METALLIC STRUCTURAL FUSES. R. Vargas 1 and M. Bruneau 2 ABSTRACT

ETABS. Integrated Building Design Software. Concrete Shear Wall Design Manual. Computers and Structures, Inc. Berkeley, California, USA

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California Prepared By

1.054/1.541 Mechanics and Design of Concrete Structures (3-0-9) Outline 1 Introduction / Design Criteria for Reinforced Concrete Structures

NONLINEAR BEHAVIOR AND FRAGILITY ASSESSMENT OF MULTI-STORY CONFINED MASONRY WALLS UNDER CYCLIC LOADS

SEISMIC CAPACITY OF EXISTING RC SCHOOL BUILDINGS IN OTA CITY, TOKYO, JAPAN

BEHAVIOR OF WELDED T-STUBS SUBJECTED TO TENSILE LOADS

Expected Performance Rating System

NUMERICAL INVESTIGATION OF SEISMIC ISOLATION FOR SINGLE- TOWER CABLE STAYED BRIDGES

SEISMIC RETROFIT DESIGN CRITERIA

Structural Design of Multi-story Residential Building for in Salem, India

Nonlinear numerical analysis of SRC-RC transfer columns based on OpenSEES

load on the soil. For this article s examples, load bearing values given by the following table will be assumed.

Advanced Retrofitting Methods and Techniques for RC Building: State of an Art

NUMERICAL ANALYSIS OF A HORIZONTALLY CURVED BRIDGE MODEL

EFFECTS ON NUMBER OF CABLES FOR MODAL ANALYSIS OF CABLE-STAYED BRIDGES

! # # % % & () +, & +,,. / 0 % % ) () 3

DESIGN OF BLAST RESISTANT BUILDINGS IN AN LNG PROCESSING PLANT

CE591 Lecture 8: Shear Walls

CHAPTER 4 4 NUMERICAL ANALYSIS

A PERFORMANCE TEST STUDY ON CHINESE G4 LEAD RUBBER BEARINGS

CSA S16-09 Design of Steel Structures Canada

Simulation for the Collapse of WTC after Aeroplane Impact

DESIGN DRIFT REQUIREMENTS FOR LONG-PERIOD STRUCTURES

SEISMIC TESTING OF NON-STRUCTURAL COMPONENTS AND ASSESSMENT OF THE PRESCRIBED RESPONSE SPECTRUM

Tall buildings. Florea Dinu. Lecture 13: 25/02/2014

SEISMIC ANALYSIS OF RC FRAMED STRUCTURES RETROFITTED WITH STEEL BRACES

Eurocode 4: Design of composite steel and concrete structures

Comparison of Seismic Performance of D-region of Existing RC Structures Designed with Different Recommendations

A COMPUTER ANALYSIS OF THE VINCENT THOMAS SUSPENSION BRIDGE

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

CE591 Fall 2013 Lecture 26: Moment Connections

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN

Modern Codes for Design of Concrete Concrete Structures Presentation Outline

EARTHQUAKE INDUCED AMPLIFIED LOADS IN STEEL INVERTED V- TYPE CONCENTRICALLY BRACED FRAMES

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

A project report on, Prepared in partial fulfillment of. Study oriented project, Course code: CE G611 Computer Aided Analysis and Design

ASSESSMENT AND RETROFITTING OF EXISTING RC BUILDINGS IN VIETNAM IN TERMS OF EARTHQUAKE RESISTANCES

In this study analytical investigation of effect of retrofit application using carbon fiber (CFRP) on seismic behavior of a monumental building at

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Hunter College school of Social Work Thesis Proposal

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

INTRODUCTION TO BEAMS

ADVANTAGES OF STEEL FIBRE REINFORCED CONCRETE IN INDUSTRIAL FLOORS

How To Design A Post Tensioned Deck For A Building

REVISION OF GUIDELINE FOR POST- EARTHQUAKE DAMAGE EVALUATION OF RC BUILDINGS IN JAPAN

Retrofitting By Means Of Post Tensioning. Khaled Nahlawi 1

Untopped Precast Concrete Diaphragms in High-Seismic Applications. Ned M. Cleland, Ph.D., P.E. President Blue Ridge Design, Inc. Winchester, Virginia

Magnetic / Gravity Loading Analysis

Transcription:

STUDY, BEHAVIOUR AND COMPARISON OF BASE ISOLATED STEEL- CONCRETE-COMPOSITE STRUCTURES BY RESPONSE SPECTRUM ANALYSIS T.Dinesh kumar 1, S.Manivel 2, A.Arokiaprakash 3 1 PG Student, Structural Engineering, SRM University, Chennai, 2Assistant Professor, Civil Engineering Department, SRM University, Chennai, 3Assistant Professor, Civil Engineering Department, SRM University, Chennai, ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract - Base isolation technique is widely used to 1. INTRODUCTION safeguard building structures from damaging effects of earthquakes. The installation of base isolators at base of a structure increases the time period and reducing resonance of structure providing safety of structure against seismic forces. The type of base isolator taken for this study is Lead rubber bearing. The base isolation system have to perform three functions, they are horizontal flexibility, energy dissipation and rigidity to ensure its performance to isolate the seismic forces to safeguard buildings from earthquakes. The Lead rubber bearing quite does it well than other isolators so mostly these isolators are used widely. The study is performed to compare steel-concrete-composite structures of fixed and base isolated conditions. Predicting the behaviour of steel concrete composite structures with varying storey heights under seismic loads using response spectrum analysis under fixed and base isolated condition will provide sufficient information and confidence to go in for steel concrete composite construction in India. For this study a 10 storey Steel- Concrete-Composite structures is considered and a Response spectrum analysis is carried out in ETABS2015. The Lead rubber bearing is designed as per UBC97 and was used in analysis of Base isolation systems. Time period of base isolated structures is comparatively higher than building under fixed condition and with the reduced base shear at base of the structures prove the efficiency of base isolated structures compared to fixed base structures and serves better during earthquakes. It is fount that Concrete structure with base isolation is more effective in seismic prone areas compared to other structures (Steel-SRC-CFT) considered in this study. Key Words: Steel Concrete - Composite structures, Response spectrum analysis, Base isolation, Lead rubber bearing. Steel and concrete structures are the structures in civil engineering practice all over the globe in huge and especially in India. Composite structures are developing in various countries and in India it is yet to be practiced. Therefore the performance of these structures of various storey heights with different seismic prone zones and loads are taken under this study to exhibit and find the best fit structure to serve the needs effectively for our criterion. Steel-concrete composite systems have seen widespread use in recent decades because of the benefits of combining the two construction materials. Reinforced concrete is inexpensive, massive, and stiff, while steel members are strong, lightweight, and easy to assemble. In decks, composite systems eliminate the need for formwork. In columns, two systems are commonly used, steel reinforced concrete (SRC) where a steel section is encased in concrete, and concrete filled tubes (CFTs). One important advantage of composite systems is that construction is accelerated through separation of trades. Initially, a bare steel frame is erected to carry the gravity, construction, and lateral loads during construction. As erection of the building progresses, concrete is cast in lower-level columns to form the composite system that will resist the total gravity and lateral loads. The inelastic behaviour of composite members and systems, which is particularly important in limit state calculations for earthquake resistant design, is not yet thoroughly understood. As a result, design provisions for composite structures have generally been extrapolated from provisions for traditional reinforced concrete or steel structures. Nonlinearities in the response of steel-concrete structures stem from inelasticity of the materials or from changes in the geometry of the structure. The sources of material inelasticity are related to the components of a composite system, namely, concrete and steel. Concrete is a 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2398

brittle material with distinctively different responses in tension and compression. A response spectrum is simply a plot of the peak or steady-state response (displacement, velocity or acceleration) of a series of oscillators of varying natural frequency that are forced into motion by the same base vibration or shock. The resulting plot can then be used to pick off the response of any linear system, given its natural frequency of oscillation. One such use is in assessing the peak response of buildings to earthquakes. Lead rubber bearing (LRB) are the laminated rubber bearing containing one or more lead plugs to deform in shear. The lead in the bearing deforms physically at a flow stress of 10 MPa, providing the bearing with bilinear response. For that reason the lead must fit tightly in the elastomeric bearing, and this is achieved by making the lead plug slightly larger than the hole and applying force at the time of inserting it in the hole. 1.1 OBJECTIVE OF WORK To compare the response of the building such as Time period, Maximum displacement and Base shear for 10 storied Steel-Concrete-Composite buildings with and without base isolation by considering the Response spectrum analysis. 1.2 SCOPE OF WORK Steel-concrete composite structures are effective structural systems for high-rise buildings but these structures are mostly not employed in Indian conditions. Predicting the behaviour of steel concrete composite structures with varying storey heights under seismic loads using response spectrum analysis under fixed and base isolated condition will provide sufficient information and confidence to go in for steel concrete composite construction in India. 1.3 METHODOLOGY Analyze, design and comparison of results to arrive at an efficient structural alternative among steel, Concrete and composite structures (Fixed and Base isolated) for G+10 commercial building with moment resistant frames. Literature study Performing linear-dynamic statistical analysis (Response spectrum analysis). Carry out 3-D modeling of the structure using structural analysis software ETABS2015. By use of MS Excel program to carry out design of base isolated Steel-Concrete-composite structures. Validation of results obtained. 2. LITRETURE STUDY Chandak N. R. [1] was presented the work reelected to Effect of Base Isolation on the Response of Reinforced Concrete Building. The six storey building is analyzed with rubber isolating device and by providing friction pendulum isolation device at its base. The analysis was done by using response spectrum analysis. Results obtained from the presented work shows that there is reduction of base shear, storey drift, storey shear, torque and increment in the storey displacement. Santosh H.P. et al. [2] presented the work on seismic analysis of low to medium rise building for base isolation. The lead rubber isolator was used as an isolating device. The analysis was done by using STAAD Pro software. The six storey building were analyzed both by considering the base as fixed base structure and then by considering it as a base isolated by means of lead rubber bearings. The analytical results obtained show the reduction in storey acceleration and the storey shear in case of base isolated structure compared to non isolated structure. Torunbalci N. et al. [3] presented the analytical study on mid-storey building by considering various seismic isolation techniques. For a case study, a six storey building was analyzed by using three dimensional nonlinear time history analysis. The analysis was done on the basis of various seismic isolation and energy dissipating alternatives. Alternatives which included rubber bearings, friction pendulum bearings, additional isolated storey and viscous dampers. Dhawade S.M. [4] presented the comparative study for seismic performance of base isolated & fixed based RC frame structure. The high density rubber isolator used as a isolation device. The work presented by author was done on (G+14) structures using ETABS software. A linear static analysis was carried out on the given structure. The comparative study was presented hear between fixed base and base isolated structure. A result shows reduction in the storey drift, shear, acceleration and increment in the storey displacement. Jerome Hajjar, (2002) has investigated and shown that concrete filled steel tube columns are used as super columns in high-rise structures, where they form the primary loadbearing members in the buildings gravity and lateral resistance systems. Steel lies at the outer perimeter, where it performs effectively in resisting flexure as well as axial tension and compression, while concrete forms an excellent 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2399

core to help withstand compressive loading. The steel reinforced concrete beam-column has the potential to provide excellent strength and ductility relative to RC members. Shirule et al, (2012) used an 18-storey symmetrical R.C.C building as a test model. Lead Rubber Bearing (LRB) and Friction Bearing (FB) is used as isolation system in this study. Nonlinear Time History analysis is used on both of fixed base and base isolated buildings. There are two portions; one is comparative study of performance of fixed base condition and base isolation (LRB and FB) condition and the comparative study of performance by three different time histories Bhuj, Koyna and Lacc T.H.Finally, base shear, displacement and acceleration are compared from 3 times history analysis between fixed base condition and base isolated condition. The base shears in each direction are decreased with LRB by 46% and with FB by 35% in base isolated building compared to the fixed base building Panchal and Marathe, (2011) have brought out that steel option is better than R.C.C. But composite option for highrise building is best suited among all three options. The reduction in the dead weight of steel framed structure is 32% with respect to R.C.C frame structure and composite framed structure. Total saving in the composite option as compared to the R.C.C results in 10% so as with steel it will be 6-7% and composite structure gives more ductility to the structure as compared to the R.C.C which is best suited under the effect of lateral forces. Saatcioglu and Naumoski, (2005) developed the design response spectra for six functional buildings (5, 10 and 15 storeyed) and each building was moment resisting frame buildings considered in Vancouver and Ottawa and a total of the fifteen accelerograms were used for the seismic analysis. Computer software called the DRAIN-2DX was used for the analysis. These graphs give the peak value of the load. The result they obtained was that the higher floors showed higher amplification due the earthquake load and the difference in spectra are more profound for the low rise building. The response amplification relative to the ground Volume 01, No.5, May, 2015 Page 2 excitations varied from floor to floor. The amplification was of the highest at the roof level and the amplification factor for roof is approximately 4.0 for 5 storeyed buildings and, 3.0 for 10 storeyed buildings and 2.0 for 15-storeyed buildings. It decreases gradually going from roof level to the first storey level. Equations were developed in the project and they can also be used to generate floor design spectra from the UHS specified for a given location. 3. MODELING AND ANALYSIS Modeling and Analysis is carried out using ETABS 2015. Response spectrum is carried out on all models. Beam and Column are considered as frame element and slab is considered as area element and its property varies based on the type of structures taken into this study. 3.1 MODELS CONSIDERED Totally 8 models is been considered for this study below describes the details of it, a- Steel structure under fixed condition b- Concrete structure under fixed condition c- Composite structure(src) with fixed condition d- Composite structure(cft) under fixed condition e- Steel structure with base isolation f- Concrete structure with base isolation g- Composite Structure(SRC) with base isolation h- Composite structure(cft) with base isolation FIG. 1: Plan view of building for all models 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2400

Parapet height 1.2m Wall thickness 230mm 3.3 WORK DETAILS Table-2 Section details Structure Column Beam Steel WPB400 ISMB250 FIG 2: 3D view of Composite BI building Concrete 600x600mm 400x300 Composite(SRC) 450x450(ISMB400) ISMB350 Composite(CFT) 600x600mm Flange & Web thickness-25mm ISMB350 FIG 3: Elevation of Composite BI building 3.2 BASIC CONSIDERATIONS Table-1 Building details No. of storey G+10 Storey height 3m 3.4 LOADING DATA Floor finish = 1.25 kn/m 2 Live load on roof = 1.5 kn/m 2 Live load on floor = 2 kn/m 2 3.5 EARTHQUAKE DATA Slab thickness Support conditions Soil type Steel grade Grade of Concrete 150mm Fixed, Base isolated class2, medium soil Fe250 M25 beam, M30 column Zone (Z) = II Response reduction factor (R) = 3 Importance factor (I) =1 Zone factor = 0.16 Damping ratio (DM) = 0.05 3.6 LRB LINK PROPERTIES Nonlinear Link Type : Rubber Isolator 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2401

U1 Linear Effective Stiffness : 1500000 kn/m U2 and U3 Linear Effective Stiffness: 800 kn/m U2 and U3 Nonlinear Stiffness U2 and U3 Yield Strength : 2500 kn/m : 80 kn U2 and U3 Post Yield Stiffness Ratio: 0.1 4. RESULTS AND DISCUSSION The Time period, Base shear and storey displacements for all type of structures with and without Base isolation are obtained in this study and are compared for its effective seismic behaviour. 4.1 TIME PERIOD The above graph shows the comparisons of time period V/s Concrete-Steel-Composite (SRC & CFT) structures of 10 storied building. From FIG.5: It is clear that, time period of base isolated structures increases compared to fixed condition structures. From the graph, percentage increase of the time period of base isolated structures compared to fixed conditions are (Concrete = +62%, Steel = +34%, SRC = +48%, CFT = +59%). 4.2 BASE SHEAR The base shear is distributed along the height of the structure in terms of lateral force. The use of base isolation in a structure reduces the shear compared to fixed conditions. The results are plotted in figure 6. FIG.6: Storey shear V/s different models FIG.4: Time period V/s mode shapes From fig.4 it is observed that, time period decreases with increase in mode number. As result of the increased flexibility of the system, time period of the structure is also increases. From FIG.6: It is clear that, base shear of base isolated structures decreases compared to fixed condition structures. From the graph, percentage decrease of the base shear of base isolated structures compared to fixed conditions are (Concrete = -47%, Steel = -39%, SRC = -40%, CFT = -47%). 4.3 LATERAL DISPLACEMENT The lateral displacement for all models under response spectrum analysis are shown in the below figure 7. FIG.5: Time period V/s different models 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2402

REFERENCES FIG.7: Maximum Storey displacement V/s different models From FIG.7: It is clear that, displacement of base isolated structures increases compared to fixed condition structures. From the graph, percentage increase of the displacement of base isolated structures compared to fixed conditions are (Concrete = +54%, Steel = +37%, SRC = +41%, CFT = +50%). 5. CONCLUSIONS 1) The flexibility at the base of the building increases with the use of Lead rubber bearing isolators. 2) The transfer of lateral forces during earthquakes is reduced as the time period of the structure is increased by the use of base isolation (Lead rubber bearing). 3) The use of base isolation decreases the base shear, increases displacement and time period proves its efficiency over fixed condition and gives better seismic protection during earthquakes. 4) Among the 4 different structural models considered (Concrete-Steel-SRC-CFT) Concrete and CFT building structures gives better performance by the use of isolators at the base of the building as compared to other structures at higher seismic prone area. 5) Comparing the two types of composite column structures (SRC & CFT), CFT is found to be performing better than SRC in this study (CFT 10% increase compared to SRC base isolated structure) 1. Chandak N. R. Effect of Base Isolation on the Response of Reinforced Concrete Building. 2. Santosh H.P. et al. Seismic analysis of low to medium rise building for base isolation. 3. Torunbalci N. et al the analytical study on midstorey building by considering various seismic isolation techniques. 4. Dhawade S.M. comparative study for seismic performance of base isolated & fixed based RC frame structure. 5. Jain S K and Thakkar S K. Effect of Superstructure Stiffening in Base Isolated Tall Buildings, IE (I) Journal.CV, 85, (2004): pp. 142-148 chapter 6 6. Jangid R. S. and Kulkarni Jeevan A.. Rigid body response of base-isolated structures, Journal of Structural Control, 9, (2002): pp. 171 188 7. Naharajaiah Satish and Sun Xiahong. Seismic Performance of base Isolated Buildings in the 1994 Northridge Earthquake, Eleventh World Conference on Earthquake Engineering, 598, (1996): pp. 1-8 8. Mazza Fabio and Vulcano Alfonso. Base-Isolation techniques for the seismic protection of RC Framed Structures subjected to near-fault ground motions, 13 th World Conference on Earthquake Engineering, 2935, (2004): pp. 1-14 9. Dutta T.K and Jangid R.S. Seismic Reliability of Base Isolated Building Frames, Eleventh World Conference on Earthquake Engineering, 491, (1996): pp. 1-8 10. Jangid R. S. Stochastic response of building frames isolated by lead rubber bearings, Structural control and Health Monitoring, 17 (2010):pp. 1 22 11. Jangid R. S. Seismic Response of an Asymmetric Base Isolated Structure, Computers & Structures, 60 (1996): pp. 261-267 12. IS 1893 (part 1):2002, Criteria for earthquake resistant design of structures. 13. IS 456:2000, Code of practice for plain and reinforced concrete. 14. IS 800:2007, Code of practice for Steel structures 6) Comparing 4 structures considered for this study Concrete base isolated structures performs better with following criterion percentage (Time period=+62%, Base shear=47%, Maximum storey displacement=+54%) 6) From this study it is clear that use of base isolation in a structure turns out to be promising as a seismic protector safeguarding human values and materials. 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2403