2.0 DESIGN CRITERIA FOR POTABLE WATER DISTRIBUTION SYSTEMS

Similar documents
2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS

SECTION DISINFECTION OF PIPE AND WATER STORAGE FACILITIES

SECTION 8 WATER SUPPLY SYSTEMS

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

SECTION 5: SANITARY SEWER SYSTEM DESIGN

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

Standards for Water, Sewer, and Sewage Lift Station Design

SANITARY SEWER SPECIFICATIONS

MANUAL FOR THE DESIGN OF WATER AND SEWER LINES

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

CITY OF FARMERSVILLE, TEXAS

WATER & WASTEWATER SYSTEM DESIGN. Technical Design Manuals 1 & 2

SECTION 3 SANITARY SEWER DESIGN

SECTION DUCTILE IRON PIPE AND FITTINGS

SECTION WATER DISTRIBUTION SYSTEMS TABLE OF CONTENTS

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

City of Lubbock Public Works Engineering Design Standards and Specifications

Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects

Design Criteria & Service Goals

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

CD i -STREETS- Detail #

For a building with a crawl space, see Figure

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

CITY OF ANN ARBOR PUBLIC SERVICES PLAN REVIEW CHECKLIST

Rules and Regulations for Water Service Lines Water Services Department

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

SECTION 2 POTABLE WATER SYSTEMS 2.1 GENERAL 2.2 SYSTEM DESIGN

SECTION IV - TESTS AND INSPECTIONS PART 1 - GENERAL Testing - General

CHAPTER 6 SEWER SYSTEM DESIGN STANDARDS

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

SECTION DUCTILE IRON PIPE AND FITTINGS

The Jockey Pump, an Important Part of a Fire Pump System.

GOUVEIA ENGINEERING. Pre-Bid Conference Meeting Minutes. City of Los Banos. Henry Miller Area Storm Drain and L Street Waterline

Design and Construction Standards. Volume 4 Water

SECTION GROUND WATER STORAGE TANKS

SPECIFICATIONS FOR THE CONSTRUCTION OF

Distribution System Operation

Section 3510: Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

C I T Y O F S E L M A F I R E D E P A R T M E N T

SECTION FIRE HYDRANTS

514 SUPPLEMENTAL REQUIREMENTS FOR THE FORMER SOUTHEAST POLK RURAL DISTRICT

PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET

STANDARD SPECIFICATIONS FOR DESIGN AND CONSTRUCTION OF WATER LINES AND SEWER LINES

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Rule No. 16. b. The service connection will determine the point of delivery of water service to the customer.

Chapter 9 Sanitary Sewers

RESERVOIR DESIGN AND STORAGE VOLUME

Close-Out Documents... 9

SIZING OF WATER PIPING SYSTEM

LS 2540 SEWER LATERALS AND INSPECTION TEES

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

CITY OF TUCSON, WATER DEPARTMENT DESIGN STANDARD NO WATER PLAN DRAFTING STANDARDS TABLE OF CONTENTS

OAR52 A-1 (September, 1981)

MERCER ISLAND FIRE DEPARTMENT FIRE COMMERCIAL SPRINKLER STANDARDS

1. Site plans assist the Fire Department to determine where a potential spill can be contained. The detailed site plan shall include the following:

REFER TO SPECIFICATIONS AND STANDARD PLANS FOR DETAILED WATER METER, METER VAULT, AND SERVICE LINE REQUIREMENTS

APPENDIX D. (Standard Notes and Signature Blocks)

Special Specification 7021 Water Main and Sewer Line Replacements

STAFFORD COUNTY DEPARTMENT OF UTILITIES WATER AND SEWER

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Fire Pump Plan Review March 2010

CITY OF BEVERLY RULES AND REGULATIONS - SEWER SYSTEM TESTING. General

OVERVIEW OF SIDE SEWER REQUIREMENTS

Reference Guide for Obtaining Permits and Utility Services For New Construction

City of Virginia Beach Public Utilities HRPDC Regional Construction Standards, 5 TH Edition Amendments May 19, 2014

San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS

SECTION STORM DRAINAGE TABLE OF CONTENTS

Training Guide. An Introduction to Well Drawdown

TORONTO MUNICIPAL CODE CHAPTER 851, WATER SUPPLY. Chapter 851 WATER SUPPLY

CITY OF MELISSA MANUAL FOR THE DESIGN OF WATER AND SANITARY SEWER LINES

Appendix A: Acceptable pipe and fitting materials

3A General Information A. Concepts... 1 B. Conditions... 1

Water Loss Auditing and Water Leak Detection: How Much is Being Lost and Where Does it Go? PNWS-AWWA Annual Conference Michael W. Grimm, P.E.

Water Supply Code of Australia WSA

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

Water Main Lining A Sustainable Alternative to Open Cut Replacement

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

Technical Solution Sheet : Cold Water Plumbing

WEKO-SEAL Internal Joint Sealing WEKO-SEAL. internal pipe-joint sealing

TEXAS STATE BOARD OF PLUMBING EXAMINERS EXAMINATION AND REGISTRATION Endorsement Training Programs

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

SECTION 603 SANITARY SEWER FORCE MAINS

Section C-1 Pipes and Fittings

INNOVATION AND COST EFFECTIVE APPROACH TO POTABLE WATER PIPE REPLACEMENT STRATEGICALLY FOCUSED ON DISTRIBUTION SYSTEM WATER QUALITY IMPROVEMENT By

DEPARTMENT OF ENVIRONMENTAL QUALITY

ALBUQUERQUE BERNALILLO COUNTY WATER UTILITY AUTHORITY CROSS CONNECTION PREVENTION AND CONTROL ORDINANCE

Ductile Iron Pipe Couplings

SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST

Water Services and Utilities - General Regulations in Ohio

Let Us Give Utilities the Respect that they Deserve.

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

SECTION ABANDONMENT OF WATER MAINS. A. Conform to requirements of Section Submittals.

08.08 Vic-Check Valves

SUMMARY OF DISTRIBUTION INTEGRITY MANAGEMENT PROGRAM

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

Los Angeles County Department Of Public Works. Land Development Division. Bond Calculation Sheets

Transcription:

2.0 DESIGN CRITERIA FOR POTABLE WATER DISTRIBUTION SYSTEMS Potable water system improvements proposed for inclusion into the Department s service area shall be designed in accordance with all appropriate Department, California Department of Public Health (CDPH), and American Water Works Association (AWWA) standards and the following criteria. 2.01 SYSTEM DEMAND CRITERIA The Department s staff reserves the right to determine criteria for each potable water system based upon conditions that may exist for that particular location, anticipated level of development, planned use or other criteria. In general, however, potable water pipelines and appurtenance shall be sized to handle the highest demand on the system within the sphere of influence. Residential Demand UNDER CONSTRUCTION Fire Flow Demand The following are requirements to determine the Q FF (GPM) (fire flow demand) on the system. 1. Fire Flow Test Results (requires testing existing hydrants) 2. Fire Flow Demand for sprinkler systems; 3. Fire Flow requirements as obtained from the Fire Protection Agency having jurisdiction (City of Long Beach/ Division of State Architect/ State Fire Marshall) Commercial/Institutional/Industrial Demand Commercial/Institutional/Industrial development requirements shall be analyzed separately on a caseby-case basis. Please contact the Department for further information regarding the required water demands. 2.02 SYSTEM ANALYSIS UNDER CONSTRUCTION 2.03 POTABLE WATER PIPELINE SIZING CRITERIA Minimum size potable water pipeline is 6-inch inner diameter (I.D.) (excluding service lines). The following table is the maximum allowable headloss within the pipeline for design.

Q M = Maximum Daily Demand (GPM) Q FF = Fire Flow Demand (GPM) Q P = Peak Hour Demand (GPH) Maximum Allowable Headloss Design Flow Headloss (feet/ 1000 feet) Q M + Q FF (GPM) 5 Q P (GPH) 3.5 For all cases, pipeline velocities are not to exceed 8 feet per second. Hazen-Williams Coefficient The pipelines shall be designed using the following Hazen-Williams Coefficients: Hazen-Williams Coefficients Pipeline Material Coefficient Ductile Iron Pipe (Cement Mortar Lined) 120 Cement Mortar Lined Steel Pipe 120 Potable water system pressures are expected to range from 35 to 70 psi during normal operations. Contact LBWD for further information should the calculated design pressure fall below 35 psi using the design criteria above. Fire hydrants are to have 20 psi minimum residual pressure at their design capacities during a fire flow event. The Department s staff reserves the right to specify sizing of any potable water pipeline. 2.04 POTABLE WATER PIPELINE LOCATION Unless otherwise approved by Department staff, all potable water pipelines shall be located a minimum of 5 feet from curb face. Location shall not interfere with other existing utilities. The cover over the potable water pipelines shall be sufficient to provide protection of the potable water pipeline and for operation of the appurtenances. The depth shall be a minimum 45 inches and a maximum of 72 inches from the top of the pipeline to the finished surface. The Department s staff may increase or decrease this required depth as necessary to cover non-standard conditions. Potable water pipelines to all service areas shall be looped to provide dual direction supply and system flexibility. Dead end mains are undesirable, but can be considered on a case-by-case basis.

2.05 Separation Criteria Potable water pipeline shall be in accordance with California Waterworks Standards, Section 64572, Chapter 16, Title 22 of the California Administrative Code or the Department s criteria, whichever is most restrictive. Potable water pipelines parallel to sanitary sewer pipelines shall be located a minimum of ten feet (outside to outside) from the sanitary sewer pipeline. When crossing other utilities, a minimum vertical clearance of 6 shall be provided (outside to outside) unless otherwise approved by the Department and the California Department of Public Health. 2.06 POTABLE WATER PIPELINE MATERIALS Potable water pipelines and fire lines shall use the following materials: TYPE Size (inch) Material Service Lateral < 4 Copper Service Lateral 4 and 12 Ductile Iron (Class 52) Fire Line 4 and 12 Ductile Iron (Class 52) Potable Water Pipeline 6 and < 30 Ductile Iron (Class 52) Potable Water Pipeline 30 Ductile Iron (Pressure Class 350) or Cement Mortar Lined and Coated Steel Cylinder See Department standards for pipe material properties and criteria. 2.07 VALVES Water pipeline valves shall be specified as follows: Potable water pipelines 12-inch diameter and smaller shall be resilient-seated gate valves in accordance with AWWA C509 latest edition and Department criteria Potable water pipelines greater that 12-inch diameter shall have butterfly valves in accordance with AWWA C504 latest edition and Department criteria Water pipeline valves shall be located as follows: Potable water pipelines shall have 3 isolation valves installed at every tee Potable water pipelines shall have 4 isolation valves installed at every cross

Potable water pipelines shall have isolation valves installed at the dead end of a water main or at the traverse of an easement. Potable water pipeline valves shall be adequately spaced to provide pipeline isolation, repair and maintenance. Spacing shall be determined by the Department for each system to meet operational requirements. Place valves in-line with extended property lines and not within traffic intersections Valves shall be installed with valve can and cover as shown on the applicable Department Standard Drawings. Pressure class rating shall be the same as the potable water pipe on which the valve is being installed. 2.08 AIR RELEASE VALVES Air release valves shall be located at high points of potable water pipelines. Minimize usage of air release valves by adjusting the slope of potable water mains to eliminate high points. In phased developments, air valves are often located at the end of the pipeline as dictated by the phasing plan. When additional phases are constructed, the air valve shall be removed unless it is required. 2.09 BLOW-OFF VALVES Blow-offs shall be in accordance with the Department s Standard Drawings. Blow-offs shall be located at all low points of the pipeline, and at all dead-end terminal points. Minimum size of permanent blowoffs shall be 2 or as sized based on the applicable water pipeline size. Minimum size of temporary blow-offs shall be 2 or as sized based on the applicable water pipeline size. Minimize usage of blow-off valves by adjusting the slope of potable water mains to eliminate low points. 2.10 FIRE HYDRANTS Design per requirements of the Long Beach Fire Department. Developer s Engineer should obtain hydrant location and spacing information from the Long Beach Fire Department. In general, fire hydrants are located on the prolongation of the B.C. radial, on property line between lots or parcels, or at locations selected by the Long Beach Fire Department. Fire hydrant spacing is every 500 feet for residential areas, and 300 feet for industrial/commercial areas. Fire hydrants shall be in accordance with the Department s Standard Drawings, installed behind curb face at right angles to the potable water pipeline. 2.11 SERVICE INSTALLATIONS Services shall be in accordance with the Department s Standard Drawings. All service installations shall be copper and have a minimum 1 diameter. Each meter shall have its own service connected to the pipeline. Services shall run at a 90-degree angle from the pipeline to the meter box. If a service is over 125 feet (from the pipeline to the meter), the next larger diameter size service shall be installed.

2.12 BACKFLOW PREVENTION Where the Department s potable water system has the potential of becoming cross-connected to other water supplies or sources, an approved backflow prevention device is required by Title 17 of the California Code of Regulations, and shall be installed in accordance with the Department s Standard Drawings and approved materials list.