Model FR702RU. Description. Futura cabinet pump, manual nozzle, standard nozzle boot, 3/4" X 12' static wire hose. Rear discharge.

Similar documents
Model 1210C Battery Powered Pump Shown. Description

Air Eliminators and Combination Air Eliminators Strainers

BOWIE PUMPS OPERATION - MAINTENANCE

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Flygt Ball Check Valves

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

! WARNING. Before using product, read and understand instructions.

STOP M-150S, M-180S. and M-240S Fuel Pump. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

FAIRBANKS NIJHUIS FIRE PUMPS.

300 Series PA Pump and Cooler Assemblies

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Float and Thermostatic Traps Series H, C and X

Pumping Fuel & Fuel Oil

400B SERIES DIAPHRAGM PUMP

Morrison Bros. Co. General Product Specifications

CEILING CASSETTE FAN COIL UNIT

08.08 Vic-Check Valves

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Midwest Industrial Tanks

STOP. Heavy Duty Fuel Pumps. Contractor Special Fuel Pumps. Use this manual with: M Volt DC & M Volt DC

BERMAD Fire Protection

Horizontal Jet Pumps 1/3-1-1/2 HP

Stainless Steel Single and Dual Circulation Kits

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

SunMaxx Solar Filling Station Operating Instructions

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Fire Pump Plan Review March 2010

Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE

Oil and Coolant Circulating Heating System. Model - OCSM

NITROUS TRANSFER PUMP INSTRUCTIONS

Your safety and the safety of others are very important.

HYDROSTATIC TEST PUMPS

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

REMOTE PUMPS. Owner's Operation & Safety Manual OUTSTANDING FEATURES OUTSTANDING FEATURES. Models FR713, 303, 313. Model 303 and 313.

ROUGHNECK II Pumpless Drain

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Section 8 Storage Tanks & Equipment

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

MAINTENANCE INSTRUCTIONS FOR THE CLEAN-FLO CONTINUOUS LAMINAR FLOW INVERSION / OXYGENATION SYSTEM

MODEL INSTALLATION INSTRUCTIONS

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Trouble Shooting. Pump

KLE-115U Single Rack Undercounter Configuration Instruction Manual

HS-901(A) BASIC STEAM HEATING SYSTEMS

Stenner Pump Chlorinator Installation & Start Up Guide

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Operators manual Basic water heater

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Waste Oil Handling, Spill Containment & Lighting

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS

Goulds Water Technology

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

INSTALLATION AND SERVICE MANUAL

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Hydraulic Trouble Shooting

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

SERIES FR702VR 115 and 230 VOLT AC FUEL TRANSFER PUMP

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

PREPIPED LIQUID FUEL MANIFOLDS PLPM

PUMP AND MOTOR DIVISION

MEMBRANE VACUUM MINI PUMPS

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

James M. Pleasants Company

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

AIR LINE VALVES AND GAUGES

Standard Bills of Materials Commonly Ordered Models Only

VERTICAL TURBINE AND PROPELLER PUMPS

2" & 3" Poly Wet Seal Pump Instruction Manual

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

OP300S / OP350 2:1 RATIO TRANSFER PUMP

WAYNE-DRESSER HARMONY SERIES DISPENSER RETROFIT for HEALY SYSTEMS, INC. MODEL VP1000 VAPOR RECOVERY ASSIST SYSTEM OUTLINE

TYPE E Main Valve Sizes 3 /8 through 12

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

INSTALLATION & OPERATING INSTRUCTIONS

ENGINE COOLING SYSTEM

Installation, Operation, Repair and Parts Manual

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Transcription:

Model FR702 Cabinet Pump Model FR702RU Description of Included Models Model Number FR702R FR702F Description Futura cabinet pump, manual nozzle, standard nozzle boot, 3/4" X 12' static wire hose. Rear discharge. Futura cabinet pump, manual nozzle, standard nozzle boot, 3/4" X 12' static wire hose. Front discharge. Shipping Weight 72 LBS. 32.7 KGS. 72 LBS. 32.7 KGS. Safety Listings Approval Mark Organization Description File Number Classification No. Underwriters Laboratories Inc., a nationally recognized independent organization for testing of products to ensure public safety. Recognized and accepted in USA,Canada and other countries MH5329 EWTV Available Options Option Description Change in Shipping Weight (lbs.) Change in Shipping Weight (kgs.) A Upgrade to automatic nozzle from standard manual nozzle. 4.0 1.8 E Unit supplied with 220 VAC - 50 Hz motor - - G Unit supplied with 220VAC - 60 Hz motor - - L Unit supplied with meter calibrated in liters. - - U Universal nozzle boot and nozzle rertainer for automatic nozzle or vapor recovery nozzle (nozzle not included) 4.0 1.8 V Includes a vapor recovery nozzle, universal nozzle boot, 1 1/4" X 15' coaxial vapor recovery hose, vapor valve, discharge hose, tee, fittings and piping. Hose 38.0 17.2

retractor not included. -X001 Unit supplied less hose. (4.0) (1.8) -X003 Unit supplied less nozzle. (2.0) (0.9) -X005 Unit supplied less hose and nozzle. (6.0) (2.7) - Accessories Part Number TH13 702KTF0065 700F3135 6U075 N075UAU10 4200F9111 702F3626 702F3589 712F3584 700KTF3609 Description Pedestal kit - base, pedestal column and coupler for 1" pipe and union. Anti-siphon kit Hose 3/4" X 12' with static wire and ferrules. Manual nozzle (unleaded). Automatic nozzle (unleaded) 3/4" NPT threaded inlet. Nozzle spout hook to adapt automatic nozles without hanging hooks. Side mounting bracket - Red Vapor recovery nozzle (short) Coaxial vapor recovery hose 1 1/4" X 15' with fittings. Vapor recovery kit. Performance Maximum outlet pressure Maximum flow rate¹ Maximum viscosity of fluid pumped Maximum ambient operating temperature Minimum ambient operating temperature Minimum dry vacuum Minimum suction lift** 22 PSI (1.52 BAR) 18 GPM (68 LPM) Diesel Fuel 150 F (66 C)* -15 F (-26 C)* 12 Inches of mercury 15 Feet for Diesel. For gasoline see below.***

¹ Nominal flow rate at nominal voltage using a standard hose and manual nozzle with low viscosity fluid. * Consult factory for extreme temperature applications outside this range. ** The lift in feet is equivalent to the vertical distance from the surface of the fluid in the tank to the inlet of the pump, plus the friction losses through the vertical and horizontal runs of pipe. All elbows and other fittings must be included when calculating the losses. The system should be designed to require a minimum amount of suction lift. *** The lift of gasoline is dependent on Reid's vapor pressure of the gasoline and its temperature. The lower the vapor pressure and temperature, the higher the possible lift. See the more detailed discussion titled, "Practical Gasoline Suction Lift Considerations" that is attached. Flow Curve A) FR702 with 12' of 3/4" hose and manual nozzle B) FR702 with 12' of 3/4" hose and automatic nozzle. Nominal flow curve for reference only. Based on 3 feet suction lift. Actual flow rates obtained may vary. Fluid Compatibility If in doubt about the compatibility of a specific fluid, contact the supplier of the fluid to check for any adverse reactions to the following wetted materials: Cast Iron Steel Fiber Bronze/Iron Carbon Polyester Aluminum Fluorocarbon (Viton ) Buna N (Nitrile) 300S Stainless Steel PPS Ceramic 400S Stainless Steel Zinc Plated Steel

Dimensions Repair To ensure the ultimate performance, pumps must be set up according to the installation section of the Owner's Manual packed with the pump and available in the elibrary. To maintain UL Listing of this Explosion Proof pump, motor service can be performed only by a Recognized Service Center. The pump must be thoroughly flushed and drained before packing for shipment, or being taken in for service. Maintenance To keep the pump running at its best, periodically perform the following procedures: 1. Check strainer for dirt accumulation. To clean strainer, remove strainer cover (F4360) and pull out screen (F2665). 2. Remove rotor cover (F8653) and inspect vanes (F22704 - molded). Vanes should be replaced after exxcessive wear to prevent damage to pump. If more than 1/2 the total blade length extends out of the rotorslot at the extreme of travel the wear is excessive. 3. Check hose (F3135) and nozzle (F3136) for wear or damage. Bad hoses or nozzles are potential safety hazards. For detailed motor, meter and cabinet assembly servicing see the Parts and Technical Service Guide.

Frequently Asked Questions 1. My pump only pumps for a few minutes and then stops. What is happening? Generally "short cycling" indicates the motor is drawing too much current from the power source for some reason, and the thermal relay is opening to protect the insulation from the resulting heat build up. If this is what is happening the thermal relay will reset after 10 to 20 minutes and the motor will again operate. The causes of too high a current are many. The pump is designed for low viscosity fluid, like diesel or gasoline, and will overheat if used to pump oil or other higher viscosity fluids. The inlet filter screen could be clogged. Motor bearings could be defective resulting in a drag on the motor shaft rotation. See the Troubleshooting Guide in your Owner's Manual packed with your unit or the copy available "on-line" in the elibrary. 2. There is fluid leaking out of the small hole in the bottom of the pump body. How do I stop it? This small hole is described as the "weep hole" and is positioned to drain fluid that has leaked passed the dynamic seal between the pump and the motor. It is important that the leak be corrected as soon as possible to avoid damage to the front motor bearing. The problem could be as simple as foreign materials preventing the ceramic and carbon seal components from being in intimate contact, to as complex as a defective casting. See the Troubleshooting Guide in your Owner's Manual packed with your unit or the copy available "on-line" in the elibrary. 3. What can I do to avoid my pump losing prime when it sets for a time? Maintaining "prime" or keeping fluid in the inlet piping of your pumping system requires that no air leak into that piping. There being a check valve in your pump preventing air from entering your system through the nozzle, should it be opened while the pump is off. If your pump is consistently losing prime, remove and inspect the check valve (700F2661) to insure it is sealing properly. Also check all inlet piping joints and fittings and the various covers and plugs in the pump itself. Teflon type sealing tape or a sealing compound noted as resistant to fuels is recommended at all threaded piping connections. 4. When it gets hot outside my pump will not pump gasoline but my diesel pump works great, what is going on? A suction pump works by developing a vacuum above the fluid being pumped and depending on atmospheric pressure to force that fluid into that vacuum. The higher the fluid is being raised, the more vacuum is required. If the fluid turns to a gas at a lower vacuum than that required to raise the fluid out of the container, the system is said to be vapor locked. In other words, rather than enough vacuum being developed by the pump to raise the fluid, the pump is instead vaporizing the gasoline and only gas vapor is being pumped. Diesel has a very low vapor pressure at even relatively high temperatures so there is no danger of vapor locking at practical temperatures. Gasoline is blended to have different vapor pressures to aid winter starting (high vapor pressure) or avoid vapor locking in the summer (lower vapor pressure). The unit of measure used in the industry for this characteristic is Reid's Vapor Pressure. Having winter gas (high Reid's Vapor Pressure), still available in your tank in a hot spring, is a common cause of vapor locking pumps.

Once the situation exists, there are a limited number of options. Decrease the "lift" needed to raise the gasoline by filling the tank to the top is the easiest and quickest. This has the added benefit of mixing in a hopefully new blend of gasoline with a lower vapor pressure which will average the blended Reid's Vapor Pressure down. Another option is to decrease the temperature by shading and/or cooling the piping and pump in some fashion. In new systems make sure the suction pump is installed at the lowest position possible as that decreases the lift, and always install the pump and piping out of the hot sun if at all possible. Know what the Reid's Vapor pressure is of the gasoline you buy. Your supplier has, or can get, that characteristic of the gasoline for you. The Reid's vapor pressure should be 9 to 8, or lower, in the summer and 11 to 12 in the winter.