TOP 10 CHANGES 2013 CALIFORNIA ELECTRICAL CODE 2013 CALIFORNIA ENERGY CODE (ELECTRICAL)



Similar documents
SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

City of Riverside Building & Safety Division Phone: (951)

County of Riverside Building and Safety Department

8146/5 Series Breaker Panelboards

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

Solar Panel Installations

Short Circuit Current Calculations

How To Plan Out An Array Of Solar Panels

CHAPTER 2 EXAMPLES AND TABLES

Top Commercial / Residential Electrical Requirements *

PERMIT APPLICATION REQUIREMENTS FOR RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEMS

ELECTRICAL INSPECTION BULLETIN (Effective )

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

City of San Diego Residential Photovoltaic Systems Inspection Guidelines

Ontario Electrical Safety Code 25 th Edition/ 2012

BASIC NEC CODE RULES AND DESIGN PRACTICE

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

GUIDELINES FOR PLAN CHECK AND PERMIT REQUIREMENTS FOR SOLAR ENERGY SYSTEMS

CITY OF LOS ANGELES CALIFORNIA

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Building Permit Application

Guideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10

Questions and Answers for Heating and A/C Contractors

Submittal Requirements for Solar Photovoltaic Installations 10 kw or Less in One and Two Family (Duplex) Dwellings

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Entrances to and from Electrical Equipment Rooms

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

RESIDENTIAL PHOTOVOLTAIC SUBMITTAL REQUIREMENTS

GUIDELINES FOR PLAN CHECK AND PERMIT REQUIREMENTS FOR SOLAR ENERGY SYSTEMS

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

SOLAR PV SYSTEMS PERMITTING PROCESS

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Expedited Permit Process for PV Systems AC Module

Electrical Contractors. and the. New Jersey. Rehabilitation Code

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

NEC 2014 Code Changes

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

2011 National Electrical Code Questions & Answers

Los Angeles Fire Department Requirement No. 96 SOLAR PHOTOVOLTAIC SYSTEM

2011 National Electrical Code Changes

SINGLE FAMILY DWELLING ELECTRICAL SERVICES RATED 225 TO 600 AMPS

San Diego Area Chapter International Code Council

New Section 135 Requirements for Electrical Distribution Systems

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

SUBJECT CAN: Temporary Systems, Utilities and Equipment. Effective: 4/09/2013. CODE SECTION 2010 California Building Code (CBC)

Voltage Drop (Single-Phase)

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Buck - Boost Transformers

Request for Proposals for Photovoltaic System Installation

AC Module Installation Guide Content

Commercial/Industrial Electricity

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

Doe Residence kw DC Roof Mounted Photovoltaic System

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Installation Guide Content for P250xV-240 microinverters

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Solar Photovoltaic (PV) Systems

COUNTY OF LOS ANGELES BUILDING AND SAFETY DIVISION ELECTRICAL CODE FEE SCHEDULE (Title 27 of the County of Los Angeles Code, Ord No.

EXPRESS PERMITS (No Plan Check Required)

The U.S. Department of Labor projects that electrician careers will grow to 698,200 by 2022.

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

2013 BUILDING ENERGY EFFICIENCY STANDARDS

E2 Series Electric Furnaces

Electrical Design Training Class Ampacity WSDOT Winter 2008 BZA

MASTER ELECTRICIAN CODE EXAMINATION EXAMINATION REFERENCE MATERIAL AND CONTENT OUTLINE. Answers to sample questions: CONTENT OUTLINE

Errata NFPA 70. Proposed 2014 Edition

BRANCH CIRCUIT AND FEEDER REQUIREMENTS

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

City of Riverside Building & Safety Division Residential Electric Vehicle (EV) Charger Guidelines

INSPECTION GUDELINES

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Electrical Code Regulation

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training Eaton Corporation. All rights reserved.

Electrical. This section applies to the design and installation of building power distribution systems.

SECTION 19 RESIDENTIAL CONSTRUCTION IN FLOODZONES

Developed by CA Matt Paiss, and Bill Brooks, PE

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Electrical Grounding. Appendix C

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Department of Labor and Industry Electrical Licensing

IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS

HERZ-Thermal Actuators

SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE (In partnership with interested local fire officials, building officials, and industry representatives)

PV and the Electrical Code Page 1 PV and the Electrical Code

Motor Protection Voltage Unbalance and Single-Phasing

Transcription:

LOS ANGELES BASIN CHAPTER OF ICC MONTHLY CHAPTER MEETING ALHAMBRA, CA TOP 10 CHANGES 2013 CALIFORNIA ELECTRICAL CODE 2013 CALIFORNIA ENERGY CODE (ELECTRICAL) RON TAKIGUCHI, P.E. BUILDING OFFICIAL -CITY OF SANTA MONICA BOARD OF DIRECTORS CALBO BOARD OF DIRECTORS LOSANGELES BASIN CHAPTER LOS ANGELES BASIN CHAPTER OF ICC 2013 CALIFORNIA ELECTRICAL CODE 2013 CALIFORNIA ENERGY CODE (ELECTRICAL) 1

TOP 10 Statement: The Top 10 Changes are Presented with the Particular Audience in Attendance Not All Changes are Presented Which May Have an Equal or Greater Effect on Design, Construction and Compliance. 2013 California Building Codes State Buildings, Parking Lot & Walkway Lighting for: UC, Cal State, CC HCD1, HCD2, HCD AC OSHPD 1, 2, 3, 4 NEW OSHPD 3SE (Special Exemption) 4 2

2013 California Building Codes State Buildings, Parking Lot & Walkway Lighting for: UC, Cal State, CC HCD1, HCD2, HCD AC OSHPD 1, 2, 3, 4 NEW OSHPD 3SE (Special Exemption) DSA AC, DSA SS NEW DSA SS/CC (Community Colleges) SFM 5 STATE AGENCY AMENDMENTS 2013 CALIFORNIA ELECTRICAL CODE BSC SFM HCD-1 HCD-2 OSHPD 3 DPH DSA-AC DSA-SS DSA-SS/CC OSHPD 1 OSHPD 2 OSHPD 4 3

STATE AGENCY AMENDMENTS 2013 CALIFORNIA ELECTRICAL CODE BSC 2 Amendments SFM 7 Amendments HCD-1 3 Amendments HCD-2 3 Amendments OSHPD 3 37 Amendments DPH 4 Amendments DSA-AC 3 (notes only) DSA-SS 0 Amendments DSA-SS/CC 0 Amendments OSHPD 1 58 Amendments OSHPD 2 52 Amendments OSHPD 4 55 Amendments STATE AGENCY AMENDMENTS 2013 CALIFORNIA ELECTRICAL CODE BSC 2 Amendments SFM 7 Amendments HCD-1 3 Amendments HCD-2 3 Amendments OSHPD 3 37 Amendments DPH 4 Amendments DSA-AC 3 (notes only) DSA-SS 0 Amendments DSA-SS/CC 0 Amendments OSHPD 1 58 Amendments OSHPD 2 52 Amendments OSHPD 4 55 Amendments TOTAL 74 Amendments 4

STATE AGENCY AMENDMENTS 2013 CALIFORNIA ELECTRICAL CODE BSC 2 Amendments SFM 7 Amendments HCD-1 3 Amendments HCD-2 3 Amendments OSHPD 3 37 Amendments DPH 4 Amendments DSA-AC 3 (notes only) DSA-SS 0 Amendments DSA-SS/CC 0 Amendments OSHPD 1 58 Amendments OSHPD 2 52 Amendments OSHPD 4 55 Amendments TOTAL 74 Amendments 56 Local State Agency Amendments to the 2011 National Electrical Code C A C A C A C A C A Chapter 1 Add definition Ballasted Solar Photovoltaic System [BSC,HCD1,HCD2,SFM,OSHPD] Ballasted Solar Photovoltaic System A roof mounted system composed of solar photovoltaic panels and supporting members that are unattached or partially attached to the roof and must rely on their weight, aerodynamics and friction to counter the effect of wind and seismic forces. Section 110.13 Exception Mounting of Equipment Ballasted PV System 10 5

2013 CALIFORNIA ELECTRICAL CODE Analysis of Changes 2011 NEC Training Presentation by: International Association of Electrical Inspectors 12 6

13 2013 CALIFORNIA ELECTRICAL CODE 10 7

15 2013 CALIFORNIA ELECTRICAL CODE 9 8

2013 CALIFORNIA ELECTRICAL CODE 8 9

10

2013 CALIFORNIA ELECTRICAL CODE 7 11

Chapter 3 Article 310 - Ampacity Tables Complete Re-Numbering Table 310.16 now Table 310.15(B)(16) Ambient Temperature Correction Factors now Table 310.15(B)(2)(a) Table 310.15(B)(16) #14 AWG = 15A ( 20A ) #12 AWG = 20A ( 25A ) #10 AWG = 30A 23 12

25 13

2013 CALIFORNIA ELECTRICAL CODE 6 28 14

29 2013 CALIFORNIA ELECTRICAL CODE 5 15

2013 CALIFORNIA ELECTRICAL CODE 4 16

2013 CALIFORNIA ELECTRICAL CODE 3 17

18

37 38 19

2013 CALIFORNIA ELECTRICAL CODE 2 Chapter 6 690.4 Solar Photovoltaic (PV) Systems Equipment and Systems All Associated Wiring Interconnections Qualified Persons 40 20

41 2013 CALIFORNIA ELECTRICAL CODE 1 21

43 Section 110.9 Interrupting Rating Equipment intended to interrupt current at fault levels shall have an interrupting rating not less than the nominal circuit voltage and the current that is available at the line terminals of the equipment. 44 22

Section 110.9 Interrupting Rating Circuit Breakers & Fuses Current Ratings Operational e.g. 20A, 100A, 2000A Interrupting Rating e.g. 10KAIC, 42KAIC Amperes Interrupting Capacity (AIC) 45 Section 110.9 Interrupting Rating Amperes Interrupting CAPACITY Ability to interrupt short circuits Must have CAPACITY to interrupt magnitude of short circuit EVERYWHERE in the electrical system 46 23

Section 110.9 Interrupting Rating Amperes Interrupting CAPACITY Utility contribution Voltage, Amp Rating Reduction Impedance, Distance Increase Motor Contribution 47 Section 110.9 Interrupting Rating AVAILABLE Short Circuit Current vs OCD AIC Rating e.g. 1200Amp, 277/480V, 3Ø, 4W Service AIC Rating of Components = 30,000 AIC Fully Rated or Series Rated Available Short Circuit Current = 23,000 Amps SCC + Motor Contribution 48 24

49 Questions ron.takiguchi@smgov.net 50 25

51 LOS ANGELES BASIN CHAPTER OF ICC 2013 CALIFORNIA ENERGY CODE 26

2013 CALIFORNIA ENERGY CODE 10 2013 CALIFORNIA ENERGY CODE Low Rise Residential +25% 2008 Stds Multi-Family Residential +14% 2008 Stds Non-Residential +30% 2008 Stds Net-Zero, Residential 2020 Net-Zero, Non-Residential 2030 27

2013 CALIFORNIA ENERGY CODE 9 2013 CALIFORNIA ENERGY CODE Certificate of Installation Certificate of Acceptance Field Verification & Testing (NRCI) (NRCA) (NRCV) Electronic Data Registry Jan. 1, 2015 28

2013 CALIFORNIA ENERGY CODE 8 2013 CALIFORNIA ENERGY CODE Section 120.8 Building Commissioning (Non-Res) Energy Portions moved from CALGreen to CEC Owner s Project Requirements (OPR) Basis of Design (BOD) Design Phase Design Review Commissioning Documents on Drawings Commissioning Plan Functional Testing <10,000SF Only Design Phase Review & Drawings 29

2013 CALIFORNIA ENERGY CODE 7 Section 110.9 Mandatory Req s for Lighting Control Devices and Systems 110.9(c) (c) Track Lighting Integral Current Limiter Certified CEC Installation Requirements 130.4 Mfg of Current Limiter Same Mfg of Track Permanently Attached but Destructive Removal Tamper Resistant Fasteners Wiring Compartment VA Rating Factory Label Warning Electrical Panel marked: 30

Section 110.9 Mandatory Req s for Lighting Control Devices and Systems 110.9(c) (c) Track Lighting Integral Current Limiter NOTICE: Current limiting devices installed in track lighting integral current limiters connected to this panel shall only be replaced with the same or lower amperage. Adding track or replacement of existing current limiters with higher continuous ampere rating will void the track lighting integral current limiter certification, and will require resubmittal of compliance documentation to the enforcement agency responsible for compliance with the California Title 24, Part Building Energy Efficiency Standards. 2013 CALIFORNIA ENERGY CODE 6 31

Section 110.9 Mandatory Req s for Lighting Control Devices and Systems 110.9(d) (d) Track Lighting Supplementary Overcurrent Protection Panel Only for (Line-Voltage) Track Lighting No other lighting or power circuits Installed in an electrical room, or adjacent to the supply Labeled: NOTICE: This Panel For Track Lighting Energy Code Compliance Only 2013 CALIFORNIA ENERGY CODE 5 32

Section 110.10 Mandatory Req s for Solar Ready Buildings SFD = Subdivision, 10 or More Low-Rise MFD High-Rise MFD Hotels, Motels Non-Res = Three Stories and Less Section 110.10 Mandatory Req s for Solar Ready Buildings Solar Zone = A section of the roof designated and reserved for the future installation of a solar electric or solar thermal system. Access, Pathway, Smoke Ventilation, Spacing: Part 9 No Shading in Solar Zone Min Dimension : 80SF, Roof Area <= 10,000SF 160SF, Roof Area > 10,000SF 33

Section 110.10 Mandatory Req s for Solar Ready Buildings Dead Load, Live Load Indicated on Plans (but does not require load for future) Pathway for Routing of Conduit on Plans Documentation Provided to Occupant SFD: Minimum 200A (Sub-Div, 10 or More) Reserved Space 2-Pole CB Opposite End From Main CB Space Marked: For Future Solar Electric 68 34

2013 CALIFORNIA ENERGY CODE 4 Section 130.5 (Non-Res, High-Rise Res, Hotels/Motels) Electrical Power Distribution Systems a) Service Metering Metering of Total-Energy Use = Table 130.5-A 35

72 36

2013 CALIFORNIA ENERGY CODE 3 Section 130.5 (Non-Res, High-Rise Res, Hotels/Motels) Electrical Power Distribution Systems d) 120-Volt Receptacles: Circuit Controls All Buildings Controlled & Uncontrolled Receptacles SHALL BE PROVIDED Private Offices, Open Office Areas, Lobby,Conference Rooms, Copy Room, Kitchenette in Office Controlled Receptacles = Shut-Off Controls 37

Section 130.5 (Non-Res, High-Rise Res, Hotels/Motels) Electrical Power Distribution Systems d) 120-Volt Receptacles: Circuit Controls Uncontrolled Receptacles Install at Least ONE Controlled Receptacles w/in 6 feet of Uncontrolled Receptacle Controlled Receptacles Marked (to distinguish from UnControlled) 76 38

77 2013 CALIFORNIA ENERGY CODE 2 39

Section 130.5 (Non-Res, High-Rise Res, Hotels/Motels) Electrical Power Distribution Systems b) Disaggregation of Electrical Circuits Disaggregation Measurement of Electrical Load Uses Separate Distribution Systems, MCC s, SubPanels 80 40

81 2013 CALIFORNIA ENERGY CODE 1 41

Section 130.5 (Non-Res, High-Rise Res, Hotels/Motels) Electrical Power Distribution Systems c) Voltage Drop 1. Feeders = Maximum 2% V.D. Design Load 2. Branch Circuits = Max 3% V.D. Design Load Exception: Emergency Services 84 42

Questions ron.takiguchi@smgov.net 85 LOS ANGELES BASIN CHAPTER OF ICC Thank You! 86 43

87 44

45

2011 National Electrical Code Model Code Change Highlights Chapter 2 240.91 Protection of Conductors (Supervised Industrial Installations) 240.91(B) Protection of Conductors Rated Over 800A Allowance for the Round Up Rule Equal To or Greater Than 95% of OCD Rating e.g. 2008 NEC 1200A : 3 x 600kcmil = 3 x 420A = 1260A 2011 NEC 1200A : 3 x 500kcmil = 3 x 380A = 1140A 1200A x.95 = 1140A 91 404.2(C) Switches for Lighting Outlets Generally, where switches control lighting loads from a grounded general purpose branch circuit, the grounded circuit conductor for the controlled lighting circuit must be present at the switch location Many electronic lighting control devices, such as occupancy sensors require standby current to maintain a ready state of detection for the function of these devices Note: See exceptions for boxes feed by raceways and cable assembly boxes with framing cavity open at the top or bottom on the same floor level, or wall, floor, or ceilings unfinished on one side 46

47

96 48

97 49