Gas cylinder scale Model GCS-1

Similar documents
Pressure transmitter For general industrial applications Model A-10

Compact pressure switch Flameproof enclosure Ex d Model PCA

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Hand-held thermometer Model CTH7000

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Features. Picture. Specifications

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Precision digital pressure gauge Model CPG1500

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Technical Data. Dimensions

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Conductive Level Switch FK 2 Technical Data:

Inductive sensor NI10-M18-Y1X-H1141

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Redundancy Module QUINT-DIODE/40

Bimetal thermometer Model 52, industrial series

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Digital display DA 48

Technical data sheet TDS0070

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Technical Information RIA14

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Inductive slot sensor

Electronic Pressure Switch EDS 300

How To Use A Flowmeter

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Adjustment functions for both span and shift have been incorporated

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Data Sheet PS1B Pressure Switch

Digital inductive conductivity transmitter

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Flow switches Series AD/VH

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Proportional pressure regulators VPPE

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

1756 ControlLogix Chassis Specifications

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Cross-beam scanning system to detect slim objects. 100 mm in

A good connection. International approvals.

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Triple Waveband Infra-Red Flame Detection

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

2.24. Pump Controller 704. Data Sheet

DS 600. A contact free flux gate based current measurement sensor 600A rms

Differential Pressure Transmitter Model DPT-10

Combi switchbox with integrated 3/2 way pilot valve

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Three-phase monitoring relay CM-PFE

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

CAPACITIVE LEVEL METERS CLM 36

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

2.12. page Products for Explosion hazardous Environment

Air damper actuators

J TB/TW Temperature limiter, temperature monitor

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Plastic tube flowmeters Series PT/PS

CompactLogix Power Supplies Specifications

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Terminal Box. Specifications TNCN

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

3DLevelScanner II TECHNICAL DATA SHEET

Instruction Manual Differential Pressure Transmitter

Cable Plug acc. to DIN EN , Form A

Micro Motion 3098 Gas Specific Gravity Meter

Linear Luminaire with LED Series EXLUX 6402/2

Transcription:

Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in chemical delivery systems Industrial weight measurement Special features High overload safety up to 400 % 0.1 % FS accuracy Meets the highest EMC requirements Measuring ranges 0... 60 lbs to 0... 300 lbs (0... 27.22 kg to 0... 136.08 kg) High ingress protection, IP 65, for outdoor use and processes with high condensation Gas cylinder scale model GCS-1 Description The model GCS-1 gas cylinder scale has been designed for indoor and outdoor use in gas cabinets or gas containers. Due to its high IP 65 ingress protection, there is no concern with using the gas cylinder scale for gas cylinders with heavy condensation. The robust and compact design features high accuracy and temperature stability, meeting the requirements of the semiconductor industry. The gas cylinder scale meets the highest overload and EMC requirements in order to ensure safe, error-free and accurate operation. Page 1 of 5 Data sheets showing similar products and accessories: Digital indicator; model DI30; see data sheet AC 80.05

Measuring ranges lbs Measuring range 0... 60 0... 100 0... 300 Overload 0... 250 0... 300 0... 750 kg Measuring range 0... 27.22 0... 45.36 0... 136.08 Overload 0... 115 0... 130 0... 340 Reference conditions (per IEC 61298-1) Temperature: 15... 25 C Atmospheric pressure: 950... 1,050 mbar Humidity: 45... 75 % r. h. Nominal position: Horizontal Power supply: DC 24 V : see Output signal Other measuring ranges on request. Output signal Model Output signal GCS-1-A (2-wire) 4... 20 ma GCS-1-G (4-wire) DC 0... 5 V GCS-1-F (4-wire) DC 0... 10 V Model GCS-1-A: (power supply - 10 V) / 0.02 A Model GCS-1-G: > 5 kω Model GCS-1-F: > 10 kω Voltage supply Power supply DC14... 30 V Maximum output current 35 ma Accuracy specifications Accuracy of analogue signal 0.1 % of span 0.05 % of span (BFSL) Operating conditions Free fall Resistant to impact of 90 kg from a height of 10 cm Ingress protection IP 65 (IEC 60529) Ex marking Option 1 without ATEX approval Option 2 (ATEX) II 3G Ex na IIC T4/T5 X Permissible temperature ranges Ambient: -20... +50 C (T4) -20... +40 C (T5) Storage: -20... +60 C Operation: -10... +50 C Materials Sensor Aluminium Case Stainless steel Base plate Stainless steel Non-linearity (IEC 61298-2) 0.05 % of span Long-term stability (per month) 0.04 % of span (at reference condition) Adjustability of zero point, span ±5 % through built-in potentiometer Temperature coefficients in rated temperature range Mean TC zero point: ±0.1 % of span / 10 K Mean TC span: ±0.1 % of span / 10 K Page 2 of 5

Safety-related maximum values (only valid for instruments to ATEX category 3G) Model GCS-1-A (4... 20 ma) Model GCS-1-G (DC 0... 5 V) Model GCS-1-F (DC 0... 10 V) Power supply DC 14... 24 V DC 14... 24 V DC 14... 24 V Current limitation I i - - - Power limitation P i 1 W 1 W 1 W Internal capacitance C i - - - Internal inductance L i - - - Max. output voltage U o - - - Max. output current I o - - - External capacitance C o - - - External inductance L o - - - Electrical connection Type of connection: Cable outlet Cable length: 6 m ( 20 ft) Electrical safety Short-circuit resistance: S + vs. U- Reverse polarity protection: U+ vs. U- Insulation voltage: DC 500 V Connection diagram Non-hazardous area Hazardous area Non-hazardous area Hazardous area Voltage source Voltage source Brown Red Orange (e.g. digital indicator) Black (e.g. digital indicator) Brown Black Shield (connected to case) Shield (connected to case) Page 3 of 5

Dimensions in mm Weight approx. 13 lbs approx. 6 kg CE conformity EMC directive 2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (industrial application) ATEX directive 94/9/EC, ignition protection type n s Without ATEX approval Measuring range GCS-1-A (4... 20 ma) GCS-1-G (DC 0... 5 V) GCS-1-F (DC 0... 10 V) 0... 60 lbs / 0... 27.22 kg 13470273 12489540 12716121 0... 100 lbs / 0... 45.36 kg 13470302 12489612 12716171 0... 300 lbs / 0... 136.08 kg 13470311 12489621 12716201 ATEX II 3G Ex na IIC T4/T5 X Measuring range GCS-1-A (4... 20 ma) GCS-1-G (DC 0... 5 V) GCS-1-F (DC 0... 10 V) 0... 60 lbs / 0... 27.22 kg 13470116 13471148 13471253 0... 100 lbs / 0... 45.36 kg 13470257 13471156 13471261 0... 300 lbs / 0... 136.08 kg 13470265 13471164 13471288 Page 4 of 5

Accessories Digital indicators Designation AC 230 V AC 110 V Digital indicator DI30 in wall-mount enclosure 12458741 12489841 Digital indicator DI30 panel mounting 7539422 12489825 For operation in accordance with the ATEX directive an isolated barrier is required. 2011 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 5 of 5 05/2015 EN WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de