The Parker Serviceman Plus

Similar documents
USB-500 Series Low-Cost Data Loggers and Accessories

Hand-held thermometer Model CTH7000

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

USB-500/600 Series Low-Cost Data Loggers and Accessories

Typical Aluminum GFM Mass Flow Meter

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

USER MANUAL V5.0 ST100

Transmitter Interface Program

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

USB-500/600 Series Low-Cost Data Loggers and Accessories

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

1 Technical Description Lokal-200PC

Local Solutions For Individual Customers Worldwide. Hydraulic Testers of the PPC Series. Product Catalogue

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

DC Electronic Loads 8500 series

T Substation Maintenance and Commissioning Test Equipment

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Temperature & Humidity SMS Alert Controller

Multi-Function Ground

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Operation Guide VIP-45-WIFI. Video Inspection Probe

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

4-Channel Thermometer / Datalogger

Description. Dimensions. Features. precision works better

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Electronic Pressure Switch EDS 3000

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

Electronic Control Devices The European Product Catalogue 2007

GPS Vehicle and personal location tracker. User manual

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

How To Power A Schen

Controlers. Controler

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Processor. Installation Guide

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Series 6000 Torque measured metal bellow coupling

Duct Humidity Transmitter

Absolute Rotary Encoder E6CP

Dock HP Pro Portable Tablet Dock. HP Quick Charge 18W AC Tablet Adapter. HP Duet Pen Refills. Cables HP Micro USB to USB Adapter

Digital display DA 48

Wahl C50 Calibrator FEATURES

Series 7500 Torque Sensor

40.3. Control Relays and Timers

SOLAR I-V Rel /07/10

Multifunction devices

Voltech DC1000. Precision DC Bias Current Source

USB-AD14f Data Acquisition System (USB)

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

T0118 T2118 T3118. Instruction Manual

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Quick Connect. quick - simple - efficient.

Panel Meters and Controllers Modular Panel Meter Type EDM 35

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Perimeter Security System

Test equipment for temperature and its reduction

Poor quality welds Machine downtime High maintenance costs Lost revenue

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

T7560A,B,C Digital Wall Module

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Datalogger DL/N 70 Version:

EPSON Perfection 2450 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. US letter or A4 size ( inches [ mm])

EVAL-UFDC-1/UFDC-1M-16

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

HWg-STE HWg-STE PoE MANUAL

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

7 Lighting Technology

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Series DFMT Digital Paddlewheel Flowmeter

HF series Hall effect joysticks

Electronic Pressure Switch EDS 300

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

In regard to calculating system power requirements, refer to DBK Basics located near the front of this manual.

ABB Drives. User s Manual HTL Encoder Interface FEN-31

OEM-EP Pressure Controllers

SOLAR300N Rel /01/10

=============================== WARNING

EPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels

Mobile Satellite Solutions. A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL STOW SEARCH

Light Meter (Foot Candles)

GSM/3G UMTS/GPS/SMS Data Logger. The King Pigeon S262W S263W Data Logger inbuilt industrial GSM and 3G WCDMA

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Renewable Energy Monitor User Manual And Software Reference Guide. (979)

Long Distance Industrial Wireless Transmitters and Receivers

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Transcription:

The Parker Serviceman Plus Diagnostic Meter Ideal for Maintenance and Diagnostics: The new Serviceman Plus is an extremely robust, portable and easy-to-use measuring device. With a scan rate of 1 ms and the ability to read pressure, flow, temperature and RPM, it is versatile for use with mobile and industrial systems. Data can be conveniently saved to a removable nano USB stick or transferred through USB interface to a PC for further analysis with SensoWin software. The Serviceman Plus is available in two designs. One with two inputs for analog sensors and the other with CAN interface for up to three CAN sensors. Contact Information: Parker Hannifin Corporation Quick Coupling Division 8145 Lewis Road Minneapolis, MN 55427 phone 763 544 7781 fax 763 544 3418 qcd_sales@parker.com www.parker.com/quickcouplings Serviceman Plus Features: Plug and play automatic sensor recognition Large back-lit display MIN/MAX memory and differential measurements Increased memory capacity with nano USB stick USB interface to PC for convenient analysis and documentation via SensoWin software Robust design with IP67 rated protection for extreme conditions Rear panel integrated support for free-standing operation Scan rate: 1 ms

The Parker Serviceman Plus Diagnostic Instrument Technical Data - Serviceman Plus Interfaces USB device: Online data transfer between device and PC via SensoWin software; measured value transfer: ACT/MIN/MAX, min. 5 mns; USB standard: 2.0, full speed; connection assembly: Micro USB socket, protected, type B USB host: Connection of USB memory stick, max. 4 GB; recommended types: Delock USB 2.0 nano memeory stick, Intenso Mircro Line; USB standard: 2.0, full speed, max. 100 ma; connecton assembly: Micro USB socket, protected, type B Memory Internal measure value memory: 1 measurement, approx. 15,000 data records (270,000 measure values ACT/MIN/MAX) USB memory stick: 1 GB supplied Functions Difference; addition; output; ACT; MIN; MAX; FS; TEMP display; battery charge; start-stop measurement Display Type: FSTN-LCD, graphical with LED background lighting Visible area: 62 mm x 62 mm Resolution: 130 x 130 pixels Voltage (external) Micro-USB socket, type B, + 5 V DC, max. 1000 MA Battery Analog version: Type: Lithium-ion pack; 3.7 V DC/2250 mah Battery charging time with power supply: Approx. 3.5 hours Battery discharge period: > 8 hours, with 2 sensors CAN version: Type: Lithium-ion pack; 3.7 V DC/4550 mah Battery charging time with power supply: Approx. 7 hours Battery discharge period: > 8 hours, with 2 CAN- BUS sensors Casing Material of casing: PC/ABS Material of casing protective cover: TPU Dimensions (W x H x D): 96 x 172 x 54 mm Weight: approx. 540g Operating Environment Operating temperature: 0-50 C Storage temperature: -25-60 C Relative humidity: <80% Environmental assessment: DIN EN 60068-2-32 (1 m free fall) Protection catagory (EN60529): Analog IP54, CAN IP67 PC Software Read measurement data, show, analyse on PC; read device settings, edit; load device setting from library to manual measuring device Accessories that can be used with the Parker Serviceman Plus Tachometer SCRPM Precision measurement of rotational speed up to 10,000 RP Temperature Sensor Precise Measurement of oil temperatures up to 105 C Screw-in or manual sensor

SCM-155-2-05 CAN Version SCM-155-0-02 Analog Version CAN Inputs: CAN-BUS sensor auto recognition Plug connection: 5-pol, M12 x 1, SPEEDCON plug Sampling rate P-channnel: 1 ms Analog Inputs: Analog sensor auto recognition Measurement Precision: +/- 0.02% +/- one digit Plug Connection: 5-pol, push-pull Sampling rate P-channel: 1 ms Single port accepts input from up to three CAN sensors in a bus line High resistance to interference Compatible with all SensoControl CAN type sensors and accessories analog Two analog input ports Compatible with all SensoControl analog type sensors and accessories Frequency Adapter Converts the signal of a connected sensor into an analog and a CAN frequency. Measurement parameters of the converter can be set via PC with the configuration software SCMA-FCU-600 Voltage Adapter For use with Auxiliary Sensors Input: 0-4 A, 0-48 VDC Accuracy: 0.25% FS SCMA-VADC-600

Serviceman Plus Test Kits PDS4 (CAN version) Kit Contents: Serviceman Plus SCM-155-2-05 CD with SensoWin, documentation and instructions CD 4078 Case SCC-210 CAN Transducers (1 or 2) PD XXXXX-XXXX CAN Transducer Connection Cable (1 or 2 based on tranducer #) SCK-401-05-4F-4M Power Supply SCSN-440 CAN Y cable (only included with 2 transducer kit) SCK-401-0.3-Y Terminator Resistor SCK-401-R Nano USB Stick - 1 GB SCK-USB-MINISTICK USB Connection Cable - 1 meter SCK-315-02-36 PDS4 (Analog version) Kit Contents: Serviceman Plus SCM-155-0-02 CD with SensoWin, documentation and instructions CD 4078 Case SCC-210 Analog Transducers (1 or 2) PD XXXXX-XXXX Analog Transducer Connection Cable (1 or 2 based on tranducer #) SCK-102-03-02 Power Supply SCSN-440 Nano USB Stick - 1 GB SCK-USB-MINISTICK USB Connection Cable - 1 meter SCK-315-02-36 Code for Ordering Kits: PDS4 - X - XX - XX - XXX Code CAN Blank Description CAN bus technology Analog Transducer range - Pick one or two Code Description 2 PD Style Coupler Style 4 PDP Style 6 EMA2 Style (Female) 0 No transducers Code Pressure (psi) Color 01-14.5-220 Blue 06 0-870 Green 15 0-2175 Yellow 40 0-5800 Orange 60 0-8700 Red 00 No transducers 5 pin to 5 pin Cables Flow sensor, transducer and temperature probe cables. Length 10 ft (3 m) SCK-102-03-02 Extension Cable 16.4 ft (5 m) SCK-102-05-12 Adapters See Catalog 3800 for available adapters. SensoWIN Software Transfer data from the Serviceman Plus to your PC. Display up to 16 curves simultaneously. Zoom and cursor functions. Calculation functions. Software can be downloaded from parker.com

Pressure Transducers - Analog and CAN versions 220 PSI 15 bar PD * * -0100 PD * * -0600 PD * * -1500 PD * * -4000 PD * * -6000 Color Code Blue Green Yellow Orange Red Measuring Range (Pressure) -14.5 to 220 psi 0 to 870 psi 0 to 2175 psi 0 to 5800 psi 0 to 8700 (1) psi Measuring Range (Temp) -13 F to 221 F -13 F to 221 F -13 F to 221 F -13 F to 221 F -13 F to 221 F Pressure Transducers: Code for Ordering: PD XXXXX - XXXX - XXX Code CAN Blank Description CAN bus technology Analog Code Pressure (psi) Color 0100-14.5-220 Blue Pressure Range 0600 0-870 Green 1500 0-2175 Yellow Coupler Style Code TA Description PD Style 4000 0-5800 Orange 6000 0-8700 Red PTA PDP Style TEMA3 EMA3 Style (Female)

Flow Sensors - Analog and CAN Versions Flow Sensors: Code for Ordering: SCFT- XXXX - XXX - XXX Flow Range Coupler Style Code Description CAN CAN bus technology Blank Analog Code Description PD PD Style EMA EMA3 Style Code FLow Rate (gpm) 0004 0.25 4 (1 15 l/min) 0116 1 16 (4 60 l/min) 0380 3 80 (10 300 l/min) 5160 5 160 (20 600 l/min) Additional Accessories Vehicle Charging Adapter with USB connection 12/24 VAC, 1 A USB Connection Cable 2 m (for charging and connecting to PC) SCNA-USB-CAR SCK-315-02-36 2013 Parker Hannifin Corporation Bulletin 3800-SMAN PLUS /USA 5M 8/13 QCD McC Parker Hannifin Corporation Quick Coupling Division 8145 Lewis Road Minneapolis, MN 55427 Phone: 763-525-7781 Fax: 763-544-3418 www.parker.com/quickcouplings