How To. Configure E1 links. Introduction. What information will you find in this document?



Similar documents
Chapter 32 Time Division Multiplexing (TDM)

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

configure WAN load balancing

Chapter 2 - The TCP/IP and OSI Networking Models

WANs connect remote sites. Connection requirements vary depending on user requirements, cost, and availability.

WAN Data Link Protocols

! encor en etworks TM

Dedicated Access Solutions for Internet Service Providers

How To Behind A Dynamically-Assigned Public IP Address

Solution Profile. Branch in a Box

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

Notes Odom, Chapter 4 Flashcards Set:

How To Configure some basic firewall and VPN scenarios

Configure Common ISDN Access Concentration With The Firewall. How To. Introduction. What information will you find in this note?

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

Introduction to WAN Technologies

Procedure: You can find the problem sheet on Drive D: of the lab PCs. Part 1: Router & Switch

24-Port Channelized E1/T1 Line Card Overview

LifeSize Networker Installation Guide

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

Cisco Channelized T1/E1 and ISDN PRI Modules

NetVanta Series (with Octal T1/E1 Wide Module)

Configuring a Leased Line

Configuring Demand Routing for Primary ISDN Modules

FarSync TE1R. A Universal PCI adapter for E1 and T1 (G.703 / G.704) connections for Linux and Windows

Configure Allied Telesis and Cisco routers to interoperate over L2TP

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

Data Link Protocols. TCP/IP Suite and OSI Reference Model

Octal T1-10/100 RIOP Installation Guide

CCT vs. CCENT Skill Set Comparison

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Configure WAN Load Balancing

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

SSVP SIP School VoIP Professional Certification

Understand Wide Area Networks (WANs)

Network Monitoring White Paper

Configure Policy-based Routing

The Conversion Technology Experts. Media Conversion: Cost-Effectively Integrating T1 into your Fiber Network

Configuring E1 and T1 Interfaces

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva)

Cisco T1 Layer 1 Troubleshooting

1ISDN. August Software Reference ISDN 1

Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.

For T1 / E1, an NT NeTwork device must be connected to a TE Terminal Equipment device; NT must connect to TE.

CCNP2 - Implementing Secure Converged Wide-area Networks v5.0

Smart Tips. Enabling WAN Load Balancing. Key Features. Network Diagram. Overview. Featured Products. WAN Failover. Enabling WAN Load Balancing Page 1

Remote Office 911x Series Installation and Administration Guide

How To. Achieve Quality of Service over a low-speed WAN that has a non-qos capable gateway device. Introduction

High-Level Data Link Control

PBX Q-SIG Networking, Access to a Frame Relay Network

Introduction to WAN Technologies

WAN Technologies Based on CCNA 4 v3.1 Slides Compiled & modified by C. Pham

WANs and Routers. M.Sc. Aleksandra Kanevce M.Sc. Aleksandra Bogojeska

Getting Started KX-TDA5480

Solution Profile. i-net Infrastructure

FarSync TE1e. A PCI Express adapter for E1 and T1 (G.703 / G.704) connections with BNC and RJ48C connectors for Linux and Windows.

Use 802.1x EAP-TLS or PEAP-MS-CHAP v2 with Microsoft Windows Server 2003 to Make a Secure Network

Appendix D T1 Overview

This How To Note describes one possible basic VRRP configuration.

Introduction to Routing and Packet Forwarding. Routing Protocols and Concepts Chapter 1

Product VioCall Express Connect. VioCall Express Connect VoIP Solution for SMB/SME Market

Configuring E1 and T1 Interfaces

Setting Up and Testing the MAX Hardware

The network configuration for these examples is shown in the following figure. Load Balancer 1. public address

What information will you find in this document?

PPP encapsulation has been carefully designed to retain compatibility with most commonly used supporting hardware. PPP encapsulates data frames for

DigiPoints Volume 1. Student Workbook. Module 4 Bandwidth Management

ISDN. rek. Petr Grygárek Petr Grygarek, Advanced Computer Networks Technologies 1

WANPIPE TM. Multi-protocol WANPIPE Driver CONFIGURATION M A N U A L. Author: Nenad Corbic/Alex Feldman

Figure 1 - T1/E1 Internet Access

Getting Started. 16-Channel VoIP Gateway Card. Model No. KX-TDA0490

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

- T-Carrier Technologies -

EE4367 Telecom. Switching & Transmission. Prof. Murat Torlak

PRImaGate Switch RACK 3U

LAB TESTING SUMMARY REPORT

ADSL WAN Connections. Contents

WAN Technologies and Components

VALIANT COMMUNICATIONS LIMITED

Cisco 12 CCNA Certification

Routing Protocols and Concepts Chapter 2 Conceitos de protocolos de Encaminhamento Cap 2

Leased Line PPP Connections Between IOS and HP Routers

Product Overview. Features CHAPTER

The BANDIT Device in the Network

AT-S60 Version Management Software for the AT-8400 Series Switch. Software Release Notes

Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version /2004

T3 Mux M13 Multiplexer

Mediatrix 4404 Step by Step Configuration Guide June 22, 2011

Port Interface Card Installation and Safety Guide

DXC Family. Multiservice Access Node FEATURES

Chapter 4 T1 Interface Card

Configuring T1 and E1 WAN Interfaces

Cisco Packet-over-T3/E3 Service Module

ADSL MODEM. User Manual V1.0

Channelized E1 and Channelized T1 Setup Commands

How To. Configure Microsoft Windows XP ** Virtual Private Network (VPN) client interoperability without NAT-T support.

Getting Started. 16-Channel VoIP Gateway Card. Model No. KX-TDA0490

CTS2134 Introduction to Networking. Module 07: Wide Area Networks

Transcription:

How To Configure E1 links Introduction E1 is the European digital transmission format standard, traditionally used for inter-pbx traffic, where a large number of calls warrant a leased line between two corporate PBXs. Higher data bandwidth demands and reducing telecommunications charges have made 2Mbps circuits an affordable option for many smaller organisations. What information will you find in this document? This document provides information on: E1 versus T1 links on page 2. unstructured versus structured E1 on page 2. configuring unstructured E1 on page 4. configuring structured E1 on page 7. configuring the data link layer protocol on page 10. configuring the network layer protocol on page 11. troubleshooting on page 12. What product and software version does this information apply to? The information provided here applies to: AR390 and AR395 routers. AR020 E1/T1/PRA port interface card (PIC). C613-16052-00 REV A www.alliedtelesyn.com

Overview of E1 E1 versus T1 E1 is the European standard which carries data at a rate of 2048 kpbs. T1 is the United States standard, and is also used in Canada and Japan, and carries data at a rate of 1544 kbps. The AT-AR390 router supports unstructured E1 and structured E1 in point-to-point mode. Unstructured and structured E1 are described in the section below. The AT-AR395 router supports unstructured E1 and structured E1 in both point-to-point and point-to-multi-point mode. The router also supports Primary Rate Access ISDN. The AR020 E1/T1/PRA PIC supports unstructured E1 and structured E1 in both point-to-point and point-to-multi-point mode. The card also supports Primary Rate Access ISDN and T1. Unstructured versus structured E1 You can purchase E1 lines from a telecommunications company in either of two forms, unstructured or structured E1. There are various terminologies for the same type of line or circuit, whether structured or unstructured. These are listed in the following table. Unstructured E1 Structured E1 Unstructured G.703 Structured G.703/G.704 Unchannelised E1 Channelised E1 Unchannelised G.703 Channelised G.703/G.704 Clear Channel G.703 G.703/G.704 TDM 2048 kbps E1 Time Division Multiplexed E1 Full 2 Mbps E1 Since most lines have been used for voice applications, it was necessary to break an unstructured line into 64kbps channels, since 64kbps is the basis of all voice telecommunications. 2048kbps can thus be broken into thirty-two 64kbps channels, however the structuring requires the use of the first time slot or Time Slot 0 (TS0) to 'keep time', leaving time slots 1-31 available for communications. This process is called Time Division Multiplexing (TDM) or G.704 framing. Configure E1 links 2

Unstructured, structured and Primary Rate ISDN use the same physical interface, known as G.703. This is presented on either a 120 or 75 Ohm interface. It is easy to convert between the two using a G.703 balun. 120 Ohm is becoming the standard throughout most of the world, although 75 Ohm is still popular in the UK and Holland. 75 Ohm G.703 is terminated on a pair of BNC connectors, while 120 Ohm G.703 is terminated in an RJ-45 plug Further differences between unstructured and structured E1 are described below. Line clocking In unstructured E1 circuits, one of the devices must generate the clock for synchronisation, the other must receive the clock from the line. If this is not set correctly, data communications may still occur but be unstable due to frame slippage. In structured E1, the clocking is always received from the telecommunications network so the equipment at each end of the circuit must be set to receive the clock from the line. Cyclic redundancy checksum (CRC) In unstructured E1, no provision is made for CRC multi-framing, so this should be turned off in the software. In structured E1, CRC provides a means of determining and reporting line failures to both the network and terminal equipment. It is necessary to check with your telecommunications provider the correct setting for CRC-4. If CRC is not set correctly, the equipment may assume that CRC synchronisation has been lost and attempt to resynchronise, disturbing data flow and possibly giving symptoms of temporary line failure. The available options for the terminal equipment are either: Off Checking Reporting No CRC Enables CRC-4 Enables CRC-4 and reports to the remote terminal equipment An error threshold is set to allow a certain number of frames with CRC errors per second without forcing resynchronisation. In most countries, the ITU-T recommended standard of 914 error frames per second is acceptable without forcing resynchronisation. Line Encoding In E1 applications using the PPP protocol, HDB3 line encoding is used. Configure E1 links 3

Configuring the E1 layer Method 1 - Unstructured E1 System Configuration 1. Set the system name, territory, contact and location on each router It is important to set the territory since the defaults for items such as the acceptable CRC-4 error threshold are automatically changed to values appropriate for the territory the router is operating in. set system territory=europe set system name="gateway4.mydomain.org" set system location="rack 14, comms room" set system contact=routeradmin@mydomain.org 2. Set the local time on the routers This is useful when troubleshooting and checking the router's log. show time set time=10:55:00 set date=03-jun-2000 E1/PRI Interface Settings 1. Confirm the current state of the E1/PRI interface show pri=0 state State for PRI instance 0: Interface type... E1 ISDN interface type... TE HDLC controller type... SCC Mode... ISDN ISDN slots... 1-31 State... Local inbound fault Clock source... line Termination impedance... 120 ohms CRC-4 mode... reporting CRC-4 error threshold... 915 Idle character... 255 Interframe flags/slot... 1 Interface type ISDN interface type Ensure that the interface type reports E1 rather than T1 and that there are 1-31 available TDM slots. If the interface reports T1 and only 1-23 TDM slots are available then you will need to change a jumper on the AR020 PIC in the router, as the AR390 and AR395 routers support E1 only. You can find details of the E1/T1 jumper settings in the PIC hardware reference manual, which is available from your Allied Telesyn reseller or distributor. Ensure this reads TE for Terminal Equipment. NT mode is only used for Primary Rate ISDN back-to-back testing using a crossover cable. If this reads NT then again, you will need to change a jumper on the AR020 PIC in the router. Configure E1 links 4

Termination Impedance On the AR390 and AR395 routers, the termination impedance is selectable using a toggle switch on the back of the unit. On the AR020 E1/T1 PICs, an external balun is required for connection to a 75 Ohm circuit, thus will always read 120 Ohms. 2. Set the mode Set the interface to operate in what is referred to as TDM mode, although it is acknowledged that an unstructured E1 link is not technically a TDM. To set the mode to TDM, use the command: set pri=0 mode=tdm 3. Set the clock source One of the devices on the unstructured E1 circuit will need to provide a clock source internally rather than take the clocking from the line, so if an AR router is required to provide the clock then use the command: set pri=0 clock=internal 4. Set the CRC-4 mode On unstructured links the CRC-4 mode should be set to off. You can set this using the command: set pri=0 crc=off The state of the E1/PRI Interface should then look something like this: State for PRI instance 0: Interface type... E1 ISDN interface type... TE HDLC controller type... SCC Mode... TDM TDM slots... 1-31 State... Operation Clock source... internal Termination impedance... 120 ohms CRC-4 mode... off CRC-4 error threshold... 915 Idle character... 255 Interframe flags/slot... 1 Only the clock source should vary between two sites. Note that in unstructured TDM mode, slot 0 is used for data transmission. Configure E1 links 5

5. Confirm the configuration of the E1/PRI interface To confirm the E1/PRI interface configuration, use the command: show config dynamic=pri Manager gateway4.mydomain.org> sho con dyn=pri PRI configuration set pri=0 mode=tdm set pri=0 cl=int set pri=0 crc=off TDM layer configuration 1. Create an Unstructured TDM over the E1/PRI interface Choose any name for the TDM group. In this case "foo" is used. create tdm group=foo interface=pri0 unstructured You can view the settings of the TDM using the command: show tdm group=foo Interface Group Name User Speed Slots --------------------------------------------------------------- pri0 foo Yes 2048K unstructured --------------------------------------------------------------- You can view the configuration of the TDM using the command; show config dynamic=tdm TDM configuration create tdm group=foo interface=pri0 unstructured Configure E1 links 6

Method 2 - Structured E1 System Configuration 1. Set the system name, territory, contact and location on each router It is important to set the territory since the defaults for items such as the acceptable CRC-4 error threshold are automatically changed to values appropriate for the territory the router is operating in. set system territory=europe set system name="gateway4.mydomain.org" set system location="rack 14, comms room" set system contact=routeradmin@mydomain.org 2. Set the local time on the routers This is useful when troubleshooting and checking the router's log: show time set time=10:55:00 set date=03-jun-2000 E1/PRI Interface Settings 1. Confirm the current state of the E1/PRI interface show pri=0 state State for PRI instance 0: Interface type... E1 ISDN interface type... TE HDLC controller type... SCC Mode... ISDN ISDN slots... 1-31 State... Local inbound fault Clock source... line Termination impedance... 120 ohms CRC-4 mode... reporting CRC-4 error threshold... 915 Idle character... 255 Interframe flags/slot... 1 Interface Type ISDN interface type Ensure that the Interface Type reports E1 rather than T1 and that there are 1-31 available TDM slots. If the Interface reports T1 and only 1-23 TDM slots are available then you will need to change a jumper on the AR020 PIC in the router, as the AR390 and AR395 routers support E1 only. You can find details of the E1/T1 jumper settings in the PIC hardware reference manual, which is available from your Allied Telesyn reseller or distributor. Ensure this reads TE for Terminal Equipment. NT mode is only used for Primary Rate ISDN back-to-back testing using a crossover cable. If this reads NT then a jumper will require changing on the card. You can find details of the E1/T1 jumper settings in the PIC hardware reference manual, which is available from your Allied Telesyn reseller or distributor. 2. Set the interface to operate in TDM mode set pri=0 mode=tdm Configure E1 links 7

3. Set the clock source Since the clocking is provided by the CSU/DSU or modem, the router should be set to take the clock from the line. set pri=0 clock=line Termination Impedance On the AR390 and AR395 routers, the termination impedance is selectable using a toggle switch on the back of the unit. On the AR020 E1/T1PIC an external balun is required for connection to a 75 Ohm circuit, and thus will always read 120 Ohms. 4. Set the CRC-4 mode After confirming with your carrier as to whether the structured E1 network supports CRC-4 multi-framing, configure the unit for either 'off' or 'reporting', using the command: set pri=0 crc=[off reporting] Reporting monitors CRC-4 errors on the links and also informs the remote router of any errors, providing more detailed analysis of network problems. For a more detailed description of Remote Alarm indications refer to the show pri state command in the ISDN chapter of your AR Router reference manual. The state of the E1/PRI Interface should look something like this: State for PRI instance 0: Interface type... E1 ISDN interface type... TE HDLC controller type... SCC Mode... TDM TDM slots... 1-31 State... Operation Clock source... line Termination impedance... 120 ohms CRC-4 mode... reporting CRC-4 error threshold... 915 Idle character... 255 Interframe flags/slot... 1 5. Set the CRC-4 error threshold Ensure the CRC-4 error threshold is set to about 915, the ITU-T recommended standard for the number of acceptable CRC-4 errors per second before CRC-4 and frame resynchronisation is attempted. Use the command: set pri=0 error_threshold=915 Configure E1 links 8

6. Confirm the configuration of the E1/PRI interface To confirm the configuration of the E1/PRI interface, use the command: show config dynamic=pri PRI configuration set pri=0 mode=tdm set pri=0 cl=int set pri=0 crc=reporting set pri=0 error_threshold=915 TDM layer configuration 1. Create a structured TDM over the E1/PRI interface Choose any name for the TDM group. In this case "foo" is used. create tdm group=foo interface=pri0 slots=1-31 Note: In structured mode, Time Slot 0 is unavailable for data, since it is used for the G.704 framing. 2. Show the TDM settings You can view the settings of the TDM with show tdm group=foo Interface Group Name User Speed Slots --------------------------------------------------------------- pri0 foo Yes 2048K 1-31 --------------------------------------------------------------- You can view the configuration of the TDM with show config dynamic=tdm TDM configuration create tdm group=foo interface=pri0 slots=1-31 Configure E1 links 9

Configuring the data link layer protocol 1. Configure a data-link layer protocol over the structured TDM In this case Point-to-Point protocol is used. create ppp=0 over=tdm-foo 2. Ensure the Link Control Protocol has opened correctly Enter the command: show ppp=0 Name Enabled ifindex Over CP State ------------------------------------------------------------------- ppp0 YES 03 tdm-foo LCP OPENED ------------------------------------------------------------------- If you are connecting to a CISCO router, ensure that the Cisco router is set for PPP encapsulation rather than the proprietary HDLC encapsulation. CISCO routers only support the ECHO method of Link Quality Reporting, so to ensure compatibility, set ppp=0 over=tdm-foo echo=on lqr=off CISCO routers also send out proprietary Router Discovery Protocol packets. These packets are often larger than standard packets and are treated as 'Unknown Packet types' by the AR router. Ensure this is function is turned off on the CISCO router to avoid unknown packets reaching the AR router. Configure E1 links 10

Configuring the Network Layer Protocol 1. Configure a network layer protocol over the Point-to-Point-Protocol interface In this case we have used IP. enable ip add ip interface=ppp0 ip=192.168.1.1 mask=255.255.255.252 2. Configure the network layer protocol over the remote router enable ip add ip interface=ppp0 ip=192.168.1.2 mask=255.255.255.252 It is possible to configure PPP links with Unnumbered IP, where 0.0.0.0 is specified instead of an IP address in the above commands. This simplifies network administration, but can make network troubleshooting a more complex process. 3. Configure TCP/IP over the Ethernet interface add ip int=eth0 ip=172.16.1.1 mask=255.255.255.0 4. Configure TCP/IP on the remote router add ip int=eth0 ip=172.16.2.1 mask=255.255.255.0 5. Enable routing over the link This could be either a static or a dynamic (RIP or OSPF) route. In this case a static route is configured add ip route=172.16.2.0 mask=255.255.255.0 int=ppp0 next=192.168.1.2 Enable routing over the remote router add ip route=172.16.1.0 mask=255.255.255.0 int=ppp0 next=192.168.1.1 6. Test the link It should now be possible to test the link from a host on the LAN to a host on the remote LAN using PING or perhaps an FTP file transfer. In this case the LANs are not yet configured, so the PING application on the AR router is used instead. It is important to ensure the source address of the ping is set to the Ethernet interface rather than the PPP interface, since this will give the same response as if it were a device on the LAN. Enter the command: ping 172.16.2.1 sipaddess=172.16.1.1 number=50 length=64 pattern=12345678 The pattern parameter means the pings are stuffed with non-zero data, reducing the chances of the CSU/DSU modems losing synchronisation on large packets. Configure E1 links 11

Troubleshooting If no IP traffic is able to get through, try and determine whether PPP is opening at both Link Control Protocol and IP Control Protocol with the command: sho ppp=0 The routers log will often help diagnose the cause of PPP establishment failure. Use the command: show log or to display the log in reverse order, use the command: show log reverse If PPP is opening correctly but is dropping, look in the router's log and try and determine whether it is dropping in a consistent time pattern, i.e. every two minutes, or dependent on data. show log reverse A consistent failure suggests configuration of link quality reporting between routers. An inconsistent failure suggests either line failure or configuration of clocking between devices. If the failure seems to be at line level, it is worth looking at the E1/PRI counters. Since the router has only just been configured, some of the counters may be misleading since they may have been incrementing before the interface was configured. Either restarting the router or resetting the counters and leaving the unit to run for five minutes will help determine problems more accurately. Enter the command: restart router or reset pri=0 counters To look at the E1/PRI counters, use the command: show pri=0 counter This displays pages of counters which are not all relevant to an Unstructured E1 circuit (D Channels is only relevant on an interface configured for ISDN) so only interface counters can be viewed with the command: show pri=0 counter=interface Configure E1 links 12

Interface unknown protocols, or 'ifinunknownprotos' are often other manufacturer's router discovery protocols. Counters that relate to the structured channel (channel 0) can be viewed with show pri=0 counter=pri The state counters can be viewed with show pri=0 state Loss of signal counters occur when more than 32 contiguous zeros are received on an interface which is unlikely in normal data applications, although a large ping 'stuffed' with zeros or other non-realistic traffic can cause the CSU/DSU or modems to lose synchronisation. Frame slips & HDB3 code violations are indicative of incorrect clock settings between devices. You should check the clock settings. USA Headquarters 19800 North Creek Parkway Suite 200 Bothell WA 98011 USA T: +1 800 424 4284 F: +1 425 481 3895 European Headquarters Via Motta 24 6830 Chiasso Switzerland T: +41 91 69769.00 F: +41 91 69769.11 Asia-Pacific Headquarters 11 Tai Seng Link Singapore 534182 T: +65 6383 3832 F: +65 6383 3830 www.alliedtelesyn.com 2005 Allied Telesyn Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners. C613-16052-00 REV A