THERMAL MASS FLOW MEASUREMENT FOR GASES

Similar documents
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

Operations and Instruction Manual For Prime Models SIP and SRP

Thermal Mass Flow Meter (Series MST)

Thermatel Model TA1 Mass Flow Transmitter

Electronic Flow Switches

The Unique Accelabar Flow Meter

COMBIMASS. Technical Data COMBIMASS eco-bio +

SAGE GAS MASS FLOW METERS

Sanitary Type Electronic Flow Switches

For Multi-Parameter Meters see mvx

Energy and Flow Measurement for Hydronic Systems

In-Line Electronic Flow Switches

Thermatel Enhanced Model TA2 Thermal Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter

Thermal Dispersion Mass Flow

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

Take total control of your HVAC system with cost-saving flow and thermal energy meters

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

FCI ST75 Series Flow Meters

Mass Flow Meter Product Guide

Advances in Thermal Dispersion Mass Flow Meter Accuracy

By Wayne Shannon Marketing Manager

F-5100 Inline Thermal Mass Flow Meter Installation and Operation Guide

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Installing a Probe. Typical Installation

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Micro Motion 3098 Gas Specific Gravity Meter

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

O C M III. Open Channel Flow Monitor

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Thermal Mass Flow Meters

DigitalFlow GF868 Panametrics Ultrasonic Flare Gas Mass Flowmeter. GE Sensing. Features. Applications

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

AYSIX-SAGE GAS MASS FLOW METERS FOR INDUSTRY

Technical data sheet TDS0070

THEORY AND APPLICATION OF KURZ THERMAL CONVECTION MASS FLOW METERS INSTRUMENTS

Electromagnetic Flow Meter

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

IFC 070 Technical Datasheet

BB-18 Black Body High Vacuum System Technical Description

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

SUMMARY of PRODUCTS. HVAC Systems Control Airflow, Space, & Building Pressurization. Accurate airflow measurement for demanding applications

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Immersible Thermal Gas Mass Flow Meter FeaTures DescrIpTIon

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Flow Measurement Options for Pipeline and Open Channel Flow

PRODUCT REVIEW. Flowmeters and Controllers. Vacuum Instrumentation

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

General Purpose ph/orp Sensors

Galvanic Parts Per Million Dissolved Oxygen Systems

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Online Infrared Flue Gas Analyzer Gasboard 3000

In-Line Electronic Flow Switches

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

T U R B I N E G A S M E T E R

Turbine Flowmeters for Gas Applications

WEATHER STATION FOR SOLAR FARM MONITORING

Analytical Instruments Smart Analyzer 90 Type SMA

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

The. Hoffer Collection. Perfecting Measurement " A powerful source of Turbine Flowmeters and Electronics for a wide range of flow applications.

TELEDYNE HASTINGS INSTRUMENTS

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers.

T7079A,B Solid State Remote Temperature Controllers

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Laminar Flow Elements

Mass Flow Meters & Controllers

Asset Condition Monitoring Solutions

Toroidal Conductivity Sensor

Duct Humidity Transmitter

The Do s and Don ts of Pressure Transducers

M&V of Hot Water Boiler Plant. Boban Ratkovich, P. Eng, CEM, BESA, LEED AP President CES Engineering Ltd

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

B-Series Temperature Switches

Metering for today s systems

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

S300 Series Dust Monitors

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Features Direct mass flow monitoring eliminates need for separate temperature and pressure inputs. Accuracy +/- 1% of reading plus 0.

Submersion/Insertion Toroidal Sensor

Table of Contents. TransformerIQ FAQs 1

Technical Specification. Generating Set with Waukesha engine burning natural gas

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Gas Custody Transfer Calibration

Fundamentals of Mass Flow Control

DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.

PART 1 - INTRODUCTION...

The L&J Engineering Model MCG 1500SFI Servo Gauge

Airflow Sensors Line Guide

Wahl C50 Calibrator FEATURES

Boiler Control Solution. Boiler Control Solution. Instruments and Solution for Automatic Boiler Control LF3BUSS02-00EN.

Transcription:

THERMAL MASS MEASUREMENT FOR GASES Make the Wise Choice. Choose Sage Flow Meters.

A Commitment to Higher Performance SAGE METERING is a manufacturer of high performance Thermal Mass Flow Meters which measure the flow rate and consumption of gases for multiple industrial applications. Frequently used for energy management systems to monitor and improve energy efficiency as well as for regulatory compliance in environmental systems including reporting of Greenhouse Gas Emissions. TYPICAL APPLICATIONS include measurement and sub-metering of natural gas and compressed air for energy utilization and cost accounting within a facility. Measurement of combustion air flow can be used for improving efficiency in boilers and furnaces. Environmental reporting of Greenhouse Gases from combustion sources as well as measurement for carbon credits are frequently encountered. OTHER KEY environmental applications include flare gas flow measurement in the Oil and Gas Industry where thermal technology offers economic advantages over traditional flow measurement technology. To meet the regulatory requirements of periodic re-calibration or calibration verification, Sage Metering has developed a unique in-situ accuracy verification process to ensure the meter is performing within the original NIST traceable gas calibration while the process remains in operation. Sage Meters are used for all types of applications: ENERGY MANAGEMENT n Natural Gas Measurement n Compressed Air Flows ENVIRONMENTAL n Green House Gas Emissions n Carbon Credits PROCESS n Flare n Biogas / Landfill Gas n Combustion Air n Vent Air FACILITIES MANAGEMENT n Natural Gas Sub-metering n Department Cost Allocation {2} SAGE METERING, INC.

Experience and Expertise SAGE METERING, INC. is the fastest growing Thermal Mass Flow Meter manufacturer in the industry. Founded in 2002, Sage brings together individuals with many years of combined experience in the design, operation, and application of thermal mass flow meters. This vast knowledge has enabled Sage to identify and improve on the overall design and performance of thermal mass flow instrumentation. Sage s philosophy is inherent throughout its product line and services. n Innovative Products n On Time Delivery n Extraordinary Customer Service n Strong Commitment to Quality n Excellent Responsiveness to Customers Make the Wise Choice. Choose Sage Flow Meters. A Pioneer in Technology Development SAGE METERING has brought to market the first hybrid digitally-driven circuit design, eliminating the traditional analog Wheatstone bridge. This feature has provided Sage products with the ability to: n Eliminate analog drift, improving stability and long term reproducibility n Show a reproducible zero flow point, permitting simple and reliable calibration verification n Maintain higher resolution providing greater rangeability n Digitally-driven temperature sensor eliminates self-heating errors n Match overheat to application for greater signal resolution n Remote Style: up to 1000 ft. from probe, and lead-length compensated (junction box has no circuitry suitable for harsh environments) IN-SITU CALIBRATION VERIFICATION n User can easily verify that flow meter remains in calibration with simple field test while process is in operation n Checks overall instrument performance both sensor and electronics n Eliminates the need for periodic factory re-calibration n Meets regulatory requirements for calibration check FIRST GRAPHIC DISPLAY IN THERMAL INDUSTRY n Provides flow rate, temperature, totalized flow, diagnostics, and signal at a single glance n High contrast display adjusts to ambient lighting, making it easy to read IMPROVED TEMPERATURE COMPENSATION n Ensure accurate flow measurement over wide range of process temperatures ATTENTION TO ACCURACY n Calibrations performed on actual gas n NIST traceable calibration facility provides accuracy flexibility Compact Design WINNER 2012 Innovation 2011 Innovation 2006 Innovation SAGE METERING, INC. {3}

Sage Prime Thermal Mass Flow Meter (SIP Series) The Prime is Sage s premier Thermal Mass Flow Meter for all rugged industrial applications. The Prime has been approved for use in hazardous areas by many agencies, plus CE rated for Electromagnetic compatibility. Available in both 24 VDC (12 VDC optional) and 115/230 VAC input power. The 2.5 watts power is the lowest consumption in the industry. Easy access to wiring connections Easy-to-read graphic display gives flow rate, totalized flow, temperature and diagnostics information Compact design simplifies installation Available with Integral (SIP) or Remote (SRP) electronics (cable lengths to 1000 ft.) Insertion Probe (shown with optional mounting hardware SVA05) Process temperatures to 450 F (232 C) with standard sensor 1/4 to 4 flow body with flow conditioner (NPT standard, flange optional) Outputs: n 4 20 ma n Optional HART communication n Pulse n Modbus Hazardous area approvals In-situ calibration check verifies proper operation of flow meter Multiple independent calibrations available (field configurable with Addresser software) For more information on the Sage Prime (above), view the Sage SIP Flyer and Data Sheet by visiting www.sagemetering.com/prime. For more information on the Sage Prism (below), view the Sage SID Flyer and Data Sheet by visiting www.sagemetering.com/prism. Or contact Sage at 866-677-SAGE (7243). Sage Prism Portable Datalogging Flow Meter (SID Series) Logs up to 3800 points (flow rate, temperature, time stamps, etc.) Portability with 10 hours of rechargeable battery operation Furnished with carrying case and software Calibrated for three different gases or flow ranges Uploads to Excel format for storage and analysis Prism display detail {4} SAGE METERING, INC.

Sage Rio Thermal Mass Flow Meter (SIX Series) The Sage Rio Thermal Mass Flow Meter provides the same levels of performance found in the Sage Prime with the added ATEX Flameproof approvals. ATEX Flameproof approval II 2G Ex d IIB+H2 T6 Gb* Available with Integral (SIX) electronics. Remote style (SRX) optionally available 1/4 to 4 flow body with flow conditioner (NPT standard, flange optional) Rotatable graphic display gives flow rate, totalized flow, temperature and diagnostics information Outputs: n 4 20 ma n Optional HART communication n Pulse n Modbus In-situ calibration check verifies proper operation of flow meter *T6 Rating is suitable for gases with ignition temperature as low as 185 F (85 C) Insertion Probe (shown with optional flange mounting) For more information on the Sage SIX (above), view the Sage SIX Flyer and Data Sheet by visiting www.sagemetering.com/rio. For more information on the Sage Clear (below), view the Sage SIA Flyer and Data Sheet by visiting www.sagemetering.com/clear. Or contact Sage at 866-677-SAGE (7243). Sage Clear Thermal Mass Flow Meter (SIA Series) The Sage Clear Thermal Gas Mass Flow Meter provides the user with the high level of performance found in the Sage Prime while offering an economic solution for applications where hazardous area approvals are not required. High contrast graphic display shows flow rate, temperature, totalized flow and signal value 4 20 ma signal Reconfigurable software available Pulse output Input power of 24 VDC or 115/230 VAC power Compact, powerful electronics in a NEMA 4 enclosure for indoor/outdoor installations Flow bodies include flow conditioning In-Line Flow Body Available with Integral or Remote electronics (cable lengths up to 1000 ft.) Flow body for 1/4" to 4" pipe or 1/2" insertion probe Please refer to Application Data Sheet for sizing details and model number on any of the products shown on pages 4 and 5 by visiting www.sagemetering.com/applicationsdata. SAGE METERING, INC. { 5 }

5 to 25 diameters typical Flow Conditioning Any insertion flow meter measures the flow at the location of the sensor. Therefore the overall accuracy of the flow measurement is dependent on the flow profile in the pipe. With sufficient amount of straight pipe run, the desired flow profile naturally occurs. Sage recommends straight run distances which are dependent upon upstream and downstream pipe configuration. These recommended distances provide the expected flow profile at the sensor. Often the desired amount of straight run is not available. In these situations, Sage Metering offers flow conditioning assemblies. They are easily installed between two flanges as shown to the right. When using a flow conditioning assembly, the recommended straight run is greatly reduced. The use of a flow conditioner is a very 4" PIPE simple SHOWNmethod for obtaining the best possible overall accuracy. The same installation guidelines should be followed when using a Sage in-line flow body. 4" PIPE SHOWN Flow bodies, however, incorporate a built-in flow conditioning assembly, therefore reducing the straight run requirements. 15 to 25 diameters typical Typical Sage Flow Meter Installation Following a Single 90 Elbow without Sage Flow Conditioning Installed Sage Flow Conditioner Assembly (Self Heated) Typical Sage Thermal Mass Flow Meter Installation with Flow Conditioner Assembly TEMPERATURE (Reference Sensor) PROBE (Self Heated) 15 to 25 diameters typical TEMPERATURE 4" PIPE SHOWN (Reference Sensor) 15 to 25 diameters typical Customer Existing Pipe SAGE CONDITIONER ASSEMBLY 4" PIPE SHOWN 4" PIPE SHOWN 3 pipe diameters 1 pipe dia. 1 pipe dia. Customer Existing Pipe SAGE CONDITIONER ASSEMBLY Customer Existing Pipe SAGE CONDITIONER ASSEMBLY (Self Heate TEMPERAT (Reference Sensor) PROBE Compress Isolat 3/4" NPT co Threadolet SAGE o COND ASSE (All 3 meters 4" PIPE SHOWN1 pipe dia. Installation Hardware The Sage Flow Meter with insertion probe can easily be installed into a pipe or duct by using a 1/2" or 3/4" NPT connection. The two most common methods of installation are the 3/4" isolation valve with a compression fitting or the simple 1/2" compression fitting. The SAGE compression CONDITIONER fittings have Teflon ferrules which ASSEMBLY provide ease in installation and positioning the 1 pipe dia. sensor. The use of the isolation valve permits the probe to be removed while the process is in operation. Flange connections can also be provided to meet user s piping requirements. SAGE CONDITIONER ASSEMBLY 3 pipe diameters 1 pipe dia. 1 pipe dia. PROBE Isolation Valve Safety and ChainFitting Model Number SVA05 Compression Fitting Isolation Valve 3/4" NPT connection: Threadolet or half-coupling Safety Chain Compression Fitting Isolation Valve 3/4" NPT connection: Threadolet or half-coupling Compression Fitting Model Number STCF05 1/2" NPT connection: Threadolet or half-coupling 1/2" NPT connection: Threadolet or half-coupling {6} SAGE METERING, INC.

Principle of Operation Sage Thermal Mass Flow Meters measure heat transfer as the gas flows past a heated surface. The two RTD sensors are constructed from reference grade platinum windings. The RTDs are clad in a protective 316SS sheath and driven by a proprietary sensor drive circuit. The flow sensor is self-heated; the second (temperature) sensor measures the gas temperature. As gas Sage Thermal Mass Flow Technology Uses Dual Temperature Sensors to Measure Flow Rate PROBE TEMPERATURE (Reference Sensor) (Self-Heated) flows by the flow sensor the gas molecules carry heat away from the surface of the heated sensor. The sensor drive circuit replenishes the lost energy by heating the flow sensor until it reaches the desired temperature difference above the reference sensor. The electrical power required to maintain a constant temperature differential is proportional to the mass flow rate. Sage s proprietary sensor drive circuit maintains the constant temperature difference over the entire operating temperature range of the instrument. The circuit responds quickly to changes in process flow rate or gas temperature. The inherently non-linear signal provides excellent low flow sensitivity and high turndown capabilities. The signal is linearized to provide the output signal from the flow meter. Calibration Calibration is an essential portion of any thermal mass flow meter. The calibration establishes the relationship between mass flow and the power required to maintain the specified temperature difference. For best accuracy, calibrations are performed on the actual gas in Sage s NIST traceable calibration facility. Calibrations are performed to match customer s exact application requirements rather than using standard calibration ranges provided by other manufacturers. In-Situ Calibration Verification One of the challenges with any thermal mass flow meter is to check the instrument s calibration. Verification is possible if just one of the calibration data points can be checked during normal operation. Sage has developed a unique method which permits the user to verify calibration of the flow meter without having to shut down or remove the sensor from the process. This in-situ process is accomplished in three easy steps Loosen, Lift, and Look (see below). This permits the user to STEP 1 LOOSEN Simply Loosen the Valve Assembly s Lower Collar Clamp and Slightly Loosen Its Compression Fitting Lower Collar Clamp Compression Fitting Valve Shut-Off Handle (in Open Position) The In-Situ Calibration Check, conveniently performed at a No Flow (0 SCFM) condition, verifies the sensor s performance, its cleanliness, and the Flow Meter s operation and calibration. obtain a no flow data point which can be compared against the original factory calibration listed on the name plate and on the calibration certificate. STEP 2 This is all possible due to the digitally driven bridge circuit which provides excellent reproducibility and virtual elimination of electronic drift which occurs in typical analog driven designs. When the measured signal matches the original NIST traceable calibration data the accuracy of the meter is verified and also confirms that the sensors are clean. This simple test provides a tremendous benefit to the user eliminating the cost and inconvenience of periodic factory calibration of the flow meter. LIFT Lift the Probe Until Safety Chain is Taut, and Then Close the Valve as Shown in the Inset Safety Chain Valve in Closed Position STEP 3 B LOOK Look at the Milliwatt (mw) Reading on the Display (A), and Merely Compare it to the Flow Meter s Tag (B) The 3-Step In-Situ Field Check is the Easy, Cost- Effective Way to Verify the Meter s Calibration A SAGE METERING, INC. { 7 }

Make the Wise Choice. Choose Sage Flow Meters. 8 Harris Court, D1 / Monterey, CA 93940 866-677-SAGE (7243) / TEL 831-242-2030 / FAX 831-655-4965 www.sagemetering.com WINNER 2012 Innovation 2011 Innovation 2006 Innovation Part Number GB-Rev. 0912