Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2



Similar documents
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Refrigeration Basics 101. By: Eric Nelson

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

CONDENSATION IN REFRIDGERATED BUILDINGS

Rusty Walker, Corporate Trainer Hill PHOENIX

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

DESIGN STANDARDS SECTION

A/C refrigerant system, overview

Contents and Nomenclature

How To Understand Evaporator

MUELLER FALLING FILM CHILLERS

CEILING CASSETTE FAN COIL UNIT

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON

2. AIRCONDITIONING AND REFRIGERATION

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Volkswagen Golf > VW Rabbit GTI 2006->

Flushing and Cleaning the A/C System

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Environmental Data Center Management and Monitoring

MAC-120HE-01 Air-Cooled Chiller

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Open Cycle Refrigeration System

User s Manual Laminar Flow Elements

Method 202 Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources. By: Paul Ottenstein

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Sap Steady UV Unit for Maple Sap

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

THE PSYCHROMETRIC CHART AND ITS USE

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

CONDENSATION. Section Break (Next Page)

Temperature affects water in the air.

TECHNICAL BRIEF Critical Point Drying

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

Glossary of Heating, Ventilation and Air Conditioning Terms

VACUUM REFRIGERATION SYSTEMS

Stainless Steel Single and Dual Circulation Kits

Powers Controls TH 192 S Single Temperature Room Thermostat

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Watts Pure Water Systems

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

DryWeight BulkVolume

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

V47 Series Temperature Actuated Modulating Water Valves

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Additional Information. Paint Application

Cooling system components, removing and installing

Characteristics of Evaporators

PBX Series Quick Fit Connector Bimetallic Steam Traps

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Thermostatic valve Type AVTA

ENGINE COOLING SYSTEM

Medical Air Systems: Scroll

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

CHEMICAL CLEANING UNIT Product number:

CAUSTIC SOLUTION REPLACEMENT (Mud Safe CR) STABILITY TESTING

Morrison Bros. Co. General Product Specifications

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Fixtures - Parts - Accessories to shampoo bowls

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized

Activity: Clouds, Air Pressure and Temperature

Installer s Guide 18-AH39D1-13

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

MAYTAG MFD2560HEB NACIONAL E IMPORTACIÓN CABINET BACK

Sensors for Air-conditioning in Automobiles

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Fiberstars Lighted Laminar Flow Fountain Installation Manual

BRAZED PLATE INSTALLATION MANUAL

EXPERIMENT 10 CONSTANT HEAD METHOD

FLASH TANK ECONOMIZER PRODUCT GUIDE

The Axial Flow Valve. Class 300/ SERIES

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

AFE424 SERVICE PARTS

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Model 2128 AIR COMPRESSOR PUMP Operating Instructions

THE HUMIDITY/MOISTURE HANDBOOK

Solar Hot Water Heaters

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Transcription:

Instruction Manual Dew Point Tester The CVS Dew Point Tester is a chilled mirror apparatus, which operates by attaining the conditions necessary by the definition of dew point. When a gas is cooled out of contact with liquid water, the content remains constant but the percentage saturation increases until it reaches 100 percent and moisture begins to condense. The temperature at this point is known as the dew point. The CVS Dew Point Tester consists of a highpressure chamber through which the gas sample flows. A polished mirror is at one end of the chamber and a viewing window at the other. The operator throttles an expandable gas through a valve cooling the polished mirror until the dew point is observed. A mercury glass thermometer (Optional Alcohol Filled Thermometers available upon request) is inserted inside the mirror tube with the bulb of the thermometer placed close to the mirror. This allows for greater accuracies in temperature measurement. The temperature and pressure are then recorded and plotted to obtain the water content of the sample. Conversion of dew points to water content can also be obtained by use of various published curves. The Regular Chiller Model A-2 uses propane or carbon dioxide as a refrigerant. Its construction offers greater control and accurate measurements. The CVS Dew Point Tester is a rugged, reliable, mobile instrument that requires no calibration, and is primarily used to measure the moisture content in any gas. Conforms to ASTM D 1142 and GPA 2140 standards. With ordinary care and regular scheduled maintenance, the CVS Dew Point Tester will provide continuous service for many years. CVS Regular Chiller Model A-2 c/w Carrying case, 2 thermometers*, Tubing, Fittings, 3000 p.s.i Gauge, *Thermometers supplied unless otherwise specified are: 13-25: -30 to 100 0 F 13-60: -35 to 50 0 C CVS Regular Chiller Model A-2 Thermometers (Special Orders upon request) Mercury Filled Alcohol Filled Part No. Temp. Temp. Part No. Rating Rating 13-25 -30 to 110 F 13-25 RS -30 to 110 F 13-38 -100 to 10 C 13-27 RS -90 to -40 F 13-60 -35 to 50 C 13-60 RS -35 to 50 C Head Office 3900 101 Street Edmonton, Alberta, Canada T6E 0A5 Office: (780) 437-3055 Fax: (780) 436-5461 Website: www.cvs-controls.com Printed in Canada E-Mail: info@cvs-controls.com Calgary Sales Office 205, 2323 32 Avenue NE Calgary, Alberta, Canada T2E 6Z3 Office: (403) 250-1416 Fax: (403) 291-9487 1

Principle The Bureau of mines Type Dew Point Tester operates by duplicating the conditions required by the definition of dew point. Namely, that when a gas water vapor mixture is cooled out of contact with liquid water the absolute humidity, or water content, remains constant but the percentage saturation increases until it reaches 100 percent and moisture begins to condense. The temperature at this point is known as the dew point. Description of Apparatus The instrument has a pressure tight chamber to contain the gas or vapor sample and inlet and outlet valves controlling flow. At one end, a circular clear plastic window allows observation of the interior and of the mirror on which condensation of water occurs. The mirror is highly polished stainless steel and is attached at its center to a copper thermometer well. A chiller attached to the thermometer well controls expansion of refrigerant and temperature of the mirror. A thermometer whose bulb is located close to the back mirror surface indicates the mirror temperature. A pressure gauge is attached to the upper side of the chamber and a tripod socket to the bottom. In certain instances, gas being measured for dew point with the dew point tester, Bureau of Mines Type, has been through Glycol dehydrators, and consequently contains glycol vapors as well as water vapors. This sometimes leads to difficulty in determining the water dew point because the glycol vapors also condense on the mirror making observation of the water dew point difficult or uncertain. The Glycol Filter, Part 13-54 may be used with the dew point tester under such circumstances to remove the glycol vapors and increase the ease of determining the true water dew point. The filtering material in the glycol filter assembly absorbs both water vapor and glycol vapor, however in use it becomes quickly saturated with water vapor while continuing to absorb glycol vapor for a somewhat longer time. It is during this latter period that water dew points may be determined satisfactorily, since after saturation no more water vapor is removed from the gas, and dew points will be as if read without the filter. Installation An adjustable tripod is available for mounting the dew point tester when used in the field. ¼ metal tubing and fittings are provided for making the connection to the gas pipeline or tank from which the sample is to be obtained. Hose should not be used for the sample line because it may add or remove water from the gas, causing possible errors in the dew point. Hose may be used for the refrigerant connection. When putting up the apparatus and making tests in the field, it is necessary that these precautions be observed. 1. A representative sample must be taken 2. The temperature of the sampling line and Dew Point Tester must be above the temperature of the gas in the pipeline. 3. The sampling line must not contain any condensed water. 4. There must not be any appreciable reduction in pressure between the gas source and the Dew Point apparatus. 5. Dew Point tester should be located as close as possible to sample point. After the Dew Point Tester is set up with the sample connection to gas supply properly made; connect the refrigerant valve to the tank of propane or other liquefied gas to be used as a refrigerant. Open the valve on the tank so that the liquid refrigerant is available at the chiller. Propane is a satisfactory refrigerant for dew point temperatures down to about minus 20 F. Liquid carbon dioxide may be used for temperatures to minus 80 F or minus 90 F. Test Procedure 1. Purge instrument by flowing the test gas through the sample for sufficient time to expel all air. 2. Open instrument inlet valve completely and reduce the flow of sample by closing the instrument outlet valve to ensure full sample pressure in the sample chamber 3. Open refrigerant valve periodically for a couple of seconds at a time allowing sufficient time between openings so that the mirror temperature is reduced at a rate of not more than one or two degrees per minute. 2

Test Procedure Continued, 4. Simultaneously observe mirror and thermometer, noting temperature at which a spot of moisture first appears in the center of stainless steel mirror. 5. Allow mirror to warm up, noting temperature at which moisture spot disappears. 6. Repeat 4 and 5 temperatures observed are within 2 F for appearance and disappearance of moisture spot. 7. Record the mean temperature observed as the Dew Point. Interpretation of Results Dew points may be converted to water content by use of various published curves. The Deaton and Frost Curve is attached as part of these instructions. Commercial propane is usually considered dry if the dew point is minus 15 F or below. Precautions Maximum working pressure of model No. 35200 Model A-2 is 3000 psi at normal temperature. This pressure should not be exceeded. Both window and mirror may be easily removed for cleaning but care should be taken to avoid scratches. Viewing the dew point mirror through the observation mirror is not only convenient but is a safety precaution in case of window failure. Sometimes it may be necessary to run a test when atmospheric temperature is below the dew point of the gas in the pipeline. It will then be necessary to apply external heat to the sample line to avoid condensation between the pipeline and dew point apparatus. The heat should be applied as close to line as possible. In testing some gasses, it may be found that the natural gasoline dew point of the gas will be the same, or a higher temperature than the water dew point of the gas. It is necessary to visually differentiate between the two dew points. The gasoline wets the mirror and the film expands in an iridescent ring to cover the entire mirror surface, while the water condensate remains concentrated at the center. Use of the Glycol Filter The filter pressure chamber is installed on the inlet of the dew point tester. The pressure chamber has an easily removable end closure through which is inserted a copper tube containing the filter material. Internal dimensions are such that the sample gas, when introduced at the side of the pressure chamber is forced to flow through the filtering material before entering the dew point tester. At normal rates of flow, no pressure drop is introduced by the filter. As shown by the drawings, the installation of the glycol filter is made by removing the dew point tester inlet valve, screwing the filter into the opening from which the valve was removed, and relocating the inlet valve at the other side of the filter. In this position, the filter will not interfere with the dew point tester fitting on the tripod or in the carrying case. The copper tubing containing the filtering material is then inserted into the filter chamber and the end closed by the cap. An Oring sealing gasket is used and, consequently, the cap need only be screwed up hand tight. Operation of the dew point tester with the filter attached will be normal, except that a brief period of time should be allowed for the filtering material to attain equilibrium with the sample of gas. The length of this period will be determined by the quantity of water and glycol vapor in the sample gas, and may be found running dew points. Two consecutive dew points which check and which have no glycol vapor masking the mirror indicate satisfactory operation. The filtering material in the copper tube will eventually become saturated with glycol vapor and will no longer remove the vapor from the gas, after which it must be discarded and replaced with the new filter material. Again, the length of time that one charge of filter material will perform satisfactorily depends upon the glycol vapor content of the sample gas. It is important to keep the charge of the filtering, material small rather than to increase it in attempting to give it longer life as a larger volume of filter material will require proportionately longer times to come to equilibrium and give true dew points. 3

Consumables in Natural Gas The bureau of mines dew point tester is useful for determining water content or hydrocarbon dew point in natural and processed gas. Two major advantages are: 1. It can be operated at actual line pressure up to 3000 PSI without any mathematical corrections. 2. It is a primary instrument and does not rely on electronic circuits or mechanical cells, which need to be recalibrated or decontaminated. 3. The bureau of mines dew point tester uses the human eye to distinguish between the many possible condensables in field conditions. The actual photos below represent a few of these conditions and may be used as a guide to recognize the differences in appearance as the gas falls out on a chilled mirror using a CVS Controls dew point tester. Moisture Dew Point Hydrocarbon Dew Point (Using Gasoline) Clean Mirror Appears dark, smooth, and shiny Iridescent Colorful ring starts in center and expands quickly over entire mirror. Moisture Dew Point Dew forms a distinct opaque, grey spot approximately ¼-inch diameter directly in the center of mirror. Note the clean sharp edges at this point. Hydrocarbon Dew Point As hydrocarbons condense, droplets begin to form. ICE Point Crystals form an irregular pattern. They appear white against the gray dew point which has enlarged across the entire mirror. Hydrocarbon II As temperature continues to fall, droplets join together and run across mirror. Advanced ICE Point Crystals have joined together forming a very irregular pattern. Advanced Hydrocarbon Droplets collect into large drops which run down mirror. Eventually they freeze and turn white. 4

Hydrocarbon Dew Point Miscellaneous Dew Points (Using Propane) Hydrocarbon Dew Point A fog spreads across entire mirror with dark spot in center where hydrocarbons d Hydrocarbon II Dark spot enlarges and starts to become irregular shape. Alcohol Dew Point A white spot in the center of the mirror but has distinct edges unlike the sharp edges of the grey opaque water dew point. Alcohol II Spot becomes larger and increasingly white with a blue tint around outside Hydrocarbon III As temperature drops hydrocarbons begin to run down mirror. Advanced Alcohol Entire mirror becomes very white until droplets form. The drops get larger but continue to cling to mirror without freezing. Advanced Hydrocarbon With little surface tension, sheets of hydrocarbons stream down mirror and begin to puddle at bottom. Glycol Dew Point A light haze covers the entire mirror without beginning in middle. It does not change and will not evaporate. 5

3000PSI Dew Point Tester Bureau of Mines Type Model 35200 A-2 6

3000PSI Dew Point Tester Bureau of Mines Type Model 35200 A-2 Parts List Item Part Number Description Item Part Number Description 1 114V O-Ring, (2 req d) 12 13-18 Regular Chiller Body 2 13-101 Body 13 13-20 Thermoguard Assembly 3 13-5 Lucite Window 14 13-25 13-60 Thermometer, -30 to 110 0 F Thermometer, -35 to 50 0 C 4 13-102 Observation Mirror 15 13-23 Adjusting Knob 5 13-6 Window Ret, Nut 16 13-9A Mirror insulating Ring Regular Chiller Carrying Case Stand 6 13-7 17 13-86 Mirror Post Inlet and Outlet 7 56-21 18 P182-WP Hose Barb Valve 25S14BM- 2.5 Safety Gauge, 8 19 13-87* Case Bracket Knob 3000 HP 9 13-78 Mirror Ret. Nut 20 10 13-9B Mirror Insulating Sleeve 35200- CS* 11 P182-WPE Hose Elbow * Item Not Shown Case Assembly Accessories PART NUMBER DESCRIPTION 13-100A Dew Point Test Tank 13-100B Hose Assembly, c/w Re-Fill Adapter 35214 Tripod 13-1001 Refill Adapter Assembly 13-54* Glycol Filter, *Sold as a Complete Unit 7

1000PSI Dew Point Tester Bureau of Mines Type Model 35210 A-2 8

1000PSI Dew Point Tester Bureau of Mines Type Model 35210 A-2 Parts List Item Part Number Description Item Part Number Description 1 114V O-Ring 13 13-18 Regular Chiller Body Thermoguard 2 124V O-Ring 14 13-20 Assembly Thermometer, -30 to 3 13-101LP Body 13-25 110 0 F 15 Thermometer, -35 to 13-60 4 13-6LP Window Ret, Nut LP 50 0 C 16 13-23 Adjusting Knob 5 13-102 Observation Mirror 17 13-9A Mirror insulating Ring 6 13-79 Lucite Window 18 13-86 7 13-7 8 56-21 9 25S14BM- 1000 Regular Chiller Mirror Inlet and Outlet Valve 2.5 Safety Gauge, LP 10 13-78 Mirror Ret. Nut Carrying Case Stand Post 19 P182-WP Hose Barb 20 13-87* Case Bracket Knob 21 35200-CS* Case Assembly 11 P182-WPE Hose Elbow * Item Not Shown 12 13-9B Mirror Insulating Sleeve Accessories PART NUMBER DESCRIPTION 13-100A Dew Point Test Tank 13-100B Hose Assembly, c/w Tank Adapter 35215 Tripod 13-1001 Refill Adapter Assembly 13-54* Glycol Filter, *Sold as a Complete Unit 9

10

11

Head Office 3900 101 Street Edmonton, Alberta, Canada T6E 0A5 Office: (780) 437-3055 Fax: (780) 436-5461 Calgary Sales Office 205, 2323 32 Avenue NE Calgary, Alberta, Canada T2E 6Z3 Office: (403) 250-1416 Fax: (403) 291-9487 Website: www.cvs-controls.com E-Mail: info@cvs-controls.com Rev 3, June 2010 Printed in Canada CVS Controls Ltd. strives for the highest levels of quality and accuracy. The information included in this publication is presented for informational purposes only. CVS Controls Ltd. reserves the right to modify or change, and improve design, process, and specifications without written notice. Under no circumstance is the information contained to be interpreted to be a guarantee/warranty with regard to our products or services, applicability or use. Selection, use and maintenance are the sole responsibility of the end user and purchaser. CVS Controls assumes no liability for the selection use and maintenance of any product. 12