Portable Evaporative Air Cooler Safety & Maintenance Guide User tips and safety instructions

Similar documents
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

Portable Evaporative Air Cooler with Heater for indoor use. OWNER S MANUAL Read and save these instructions before use.

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Portable Air Conditioner

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Important Safeguards

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

PORTABLE AIR CONDITIONER

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Get Me Cool Now Portable Air Conditioner User s Manual

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Meaco 30L and Meaco 40L dehumidifier instruction manual

Instruction manual for Firstline FCS12000CH

Use and Care Manual. Model CPA12KH AIR CONDITIONER

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

PORTABLE AIR CONDITIONER (LOCAL)

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

WINDOW ROOM AIR CONDITIONER

Dehumidifier Users manual. For Models: DH45S DH65S

Operating Instructions Air Conditioner

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

VACUUM CLEANER INSTRUCTION MANUAL

PORTABLE AIR CONDITIONER

INSTRUCTION MANUAL. Manufactured for: Phoenix Manufacturing Inc. 90% Less energy consumption

USER S MANUAL HSC-24A

Split Type Room Air Conditioner. KSWM units

LG Wireless Remote Controller

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

Operating Instructions Split System Air Conditioner

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

Digital Photo Picture Frame. Operation Manual

Instruction Manual. Window Wiper AFW900. (Read carefully before use)

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

SAFEGUARDING THE ENVIRONMENT

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

OPERATING MANUAL ASSEMBLY. Remote control docks magnetically. click. until it clicks and locks. REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

INSTRUCTION MANUAL REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER

LG Floor Standing-Type Air Conditioner OWNER'S MANUAL

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Instruction Manual. AWK-115S

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL

Whynter 62 QT DUAL ZONE PORTABLE FRIDGE / FREEZER

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Room Air Conditioners

Operating Instructions Air Conditioner

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

Single Day Alarm Clock with. Bluetooth and USB Play-through

OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER. G Series Cooling

- 2 - IMPORTANT SAFETY REMINDERS

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

LUCCI AIRFUSION QUEST II CEILING FAN

2-SLICE COOL TOUCH TOASTER

Contact Details. Please note that some of the contact details on this PDF document may not be current.

AIR CONDITIONER (SPLIT TYPE)

CARING FOR YOUR WATER HEATER

Operating Instructions

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

R410A SPLIT SERIES DC INVERTER

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Taurus Series YORK Window Air Conditioners

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

HYLA NST Cleaning System

LG Room Air Conditioner OWNER'S MANUAL

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Convection TCO650. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

Split Air Conditioner

15GAL STEEL OIL DRAIN WITH 110V PUMP

Wireless Indoor/ Outdoor Thermometer

Split Air Conditioner

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

OWNER S MANUAL HH200M 6.12

IN-OUT Thermometer with Cable Free Sensor and Clock

Bottom Loading Water Dispenser

Please read and keep these instructions. Run water through your machine before first use

Transcription:

Portable Evaporative Air Cooler Safety & Maintenance Guide User tips and safety instructions www.honeywellaircoolers.com E-mail: info@honeywellaircoolers.com

THANK YOU Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. The Safety & Maintenance Guide and the separate User Manual are intended to provide you with important information needed to set up, operate, maintain and troubleshoot this product. USER TIPS What is Evaporative Cooling? Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep energy costs low. Warm air is drawn into the cooler and enters the Honeycomb Cooling Media. Water pumped from the water tank pours over the Honeycomb Cooling Media. As the warm air passes through the Honeycomb Cooling Media, the water absorbs the heat, naturally cooling and humidifying the air. A fan propels the cooled air out into the room. This no-compressor system cools naturally, efficiently and inexpensively. Honeycomb Cooling Media Pump Warm and dry air Cool and humid air Water Evaporative Air Cooling Mechanism The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature will be lower in drier climates because higher evaporation occurs when the humidity is low. NOTE When the product is used for the first time the Honeycomb Cooling Media will have an odor which will dissipate in a few hours or so of initial use. COOLER LOCATION To maximize efficiency, position the Air Cooler according to the following guidelines: Indoors Place the cooler in front of an open door or window. Ensure that there is adequate cross-ventilation in the room by leaving a door or window open opposite the cooler. The Evaporative Air Cooler should not be used in enclosed spaces. It must be kept level and there must be water in the water tank. Doors and windows should be opened to allow free air flow. The Evaporative Air Cooler works best when placed near an open window, so that outside air is drawn into the Evaporative Air Cooler, circulates in the room, then exits via the door. The maximum cooling effect is felt when a person is near the flow of air coming out of the Evaporative Air Cooler. The Evaporative Air Cooler produces moisture and can be used to humidify dry air. To be used for humidification the windows and doors should be closed. EN 1

COOLER LOCATION (CONTINUED) IMPORTANT: The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigerant gas. It should not be expected to cool as efficiently as a refrigerated air conditioner. Outdoors (for outdoor models only) Use only on GFCI Protected outlets/ sockets (for USA only). Power cords must be secured to avoid tripping. The wiring and connections must be protected from water. The electrical plug and Air Cooler connections must be dry at all times. Set the unit on a solid flat surface. IMPORTANT: Honeywell Outdoor Air Cooler models are designed to IPX4 product standards and not recommended to be placed outdoors during heavy rain or snow. SAFETY RULES WARNING READ AND SAVE THE AIR COOLER GUIDE AND USER MANUAL The Air Cooler Guide and User Manual are intended to provide important information needed to set up, operate, maintain and troubleshoot your Air Cooler. Failure to follow these instructions may damage and/or impair its operation, create hazards, and void the warranty. READ AND SAVE THESE INSTRUCTIONS: When using electrical appliances, basic safety precautions should always be followed: Check the household voltage to ensure it matches the appliance s rating specifications. Before operating the product, remove the packaging and check that product is in good condition. DO NOT operate with a damaged cord or plug. If the supply cord is damaged, it must be replaced with a supply cord which is as per manufacturers specifications, by the authorized service centre or its service agent or a similarly qualified person in order to avoid a hazard. DO NOT use an extension cord with this unit. DO NOT run power cord under carpeting, or cover it with rugs or runners. Keep the cord away from areas where it may be tripped over. Always ensure the water tank is filled with water above the "min." level mark, when operating the air cooler in evaporative COOLING mode. Always unplug the Air Cooler before refilling the water tank, cleaning, servicing or relocating the unit. Never pull the cord. Remove it from the electrical outlet/ socket by grasping and pulling on the plug-end of the cord. This appliance has been manufactured for use in domestic environments and must not be used for other purposes. DO NOT use in areas where gasoline, paint or other flammable goods and objects are stored. When using the COOL setting, make sure the water tank is at Max Indicator Level. Operating the unit on the COOL setting with an empty tank may result in damage to the water pump. DO NOT attempt to repair or adjust any electrical or mechanical functions of the Air Cooler, as this may void the warranty. DO NOT cover the cooler s air inlet or outlet, as this may damage the motor. DO NOT insert or allow objects to enter any ventilation or exhaust opening, as this may damage the unit and may cause electrical shock or fire. DO NOT operate with the Honeycomb Cooling Media removed, as this will overload and damage the motor. 2 EN

SAFETY RULES (CONTINUED) DO NOT leave the operating appliance unattended for an extended period of time. DO NOT allow children to play with this appliance, packaging or plastic bags. DO NOT continue to operate the unit if it is damaged or if it malfunctions. Refer to the TROUBLESHOOTING section and contact the CUSTOMER SUPPORT CENTER. Always place the unit on a dry level floor. DO NOT use in bathrooms or near water. DO NOT keep the product where it may fall into a water container. Store in a dry area when not in use. This appliance is not intended for use by persons (including children or elderly) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning the use of the appliance by a person responsible for their safety. Always grip the side handles to move the Air Cooler. WARNING: To reduce the risk of fire or electric shock, do not use this appliance with any solid state speed control device. STORAGE AND MAINTENANCE GUIDELINES Read the detailed CLEANING & DRAINING THE WATER TANK instructions for your Air Cooler, located in the separate User Manual. Below is a general guideline for maintenance and storage of your Air Cooler. WARNING: Always switch OFF the Air Cooler and unplug it from the electrical source before cleaning or maintenance. Cleaning At least once a week, drain the water tank completely and refill with fresh water. Doing this will greatly reduce mineral deposits and help to extend the life of the Honeycomb Cooling Media. End of Season Storage If the Air Cooler will not be used for a long time: Make sure all parts are dry by running the Fan Only mode for about 30 minutes before storing (time depends on ambient humidity conditions). Switch OFF the Air Cooler and unplug from the power supply. Empty/drain all the water from the tank. Note: If the unit is connected to a continuous water supply, you must switch off the water supply and remove the drain tube before draining the water tank. This function is only available on some Honeywell Air Cooler models. Check the User Manual to see if your unit has the Continuous Water Supply Function. Clean the water tank with a damp cloth to wipe away any dust or mineral deposits. Remove the Honeycomb Cooling Media and Carbon Dust Filter* from the Air Cooler and rinse under fresh water to remove dust and dirt. Replace the Honeycomb Cooling Media and Carbon Dust Filter* after they are clean and dry. To protect the unit from dust and scratches, cover with a clean cloth or plastic bag before storing. Coil the power cord and store it away from the floor to protect it. *Carbon Dust Filter is available in specific models of Honeywell Air Coolers only. Check the User Manual for your model to see if it includes a Carbon Dust Filter. EN 3

TROUBLESHOOTING GUIDE Customer Service Center: See the last page of the User Manual to find the contact details for the Customer Service Center for your area. PROBLEM POSSIBLE CAUSE SOLUTION No discharge of air. Cord is not plugged in. Power is not ON. Make sure power cord is plugged in and the switch is ON. Turn the unit ON by pressing the power button on the control panel or remote control. Not Cooling / Unit is making noise. Excessive humidity in the room. Odors. Pump is not turned ON. Low or no water in tank, when COOL is selected. Damaged Pump or Calcium deposits on blower. In cooling mode, the Air Cooler produces moisture as a result of evaporative cooling. This is normal. When the Cooler is new. Turn on COOL function from remote or control panel. Refill water tank. Contact Customer Service Center. The Air Cooler cools best in dry climates. If the ambient humidity level is high (60% or above), refrain from using the Air Cooler until ambient humidity is reduced. Make sure the window/doors are open and there is adequate cross-ventilation in the room so that the moisturized air can circulate better. Do not use the evaporative cooling function on days with high ambient humidity. When the unit is used for the first time, the Honeycomb Cooling Media will have an odor, which will dissipate within a few hours of initial use. Remote control does not work. The unit does not respond. The outdoor Air Cooler is wet from rain. Algae or mold due to moist parts. In very damp conditions, algae may form. Remote control batteries are old & used or inserted incorrectly in the battery compartment. Damaged remote control. Damaged Control Panel on unit. The Air Cooler was placed outdoors (this is only allowed for outdoor Air Cooler models) and soaked by heavy rain. Check the Honeycomb Cooling Media. If you see mold spots on the media or suspect an algae issue, remove and replace the Honeycomb Cooling Media. Contact the Customer Service Center for more information. Check water tank & other cooler parts. If you see mold spots or suspect an algae issue, use a damp cloth to wipe away the algae until all spots have disappeared. Make sure all parts are clean & dry before storage. Contact the Customer Service Center if problem persists. Replace with new batteries. Follow the polarity guide inside the battery compartment. If replacing new batteries in the correct position does not work, contact the Customer Service Center. Try to activate the unit with the Remote Control. If the unit responds, then the Control Panel on the unit may be experiencing problems - contact the Customer Service Center. If neither the Remote Control or the Control Panel is working, contact the Customer Service Center. A small amount of rain on the unit is not a problem as long as the electrical plug and outlet are dry. If they are wet, DO NOT touch the unit or electrical plug/outlet. Switch off the master power for the outlet before unplugging the unit from the electrical outlet. Make sure all outlets and plugs are dry before use. The Air Cooler is designed to IPX4 product standards and not recommended to be placed outdoors during heavy rain conditions. Do not operate the Air Cooler when wet. Wait for the Air Cooler to dry before plugging in and turning on the unit again. 4 EN

COOL TIMER POWER SWING SPEED Portable Evaporative Air Cooler User Manual Read and save these instructions before use 0.5 M 1 4 H L 2 S www.jmatek.com E-mail: usinfo@jmatek.com Model: CS10XE

COOL TIMER 0.5 1 4 H L 2 S POWER SWING SPEED PARTS DESCRIPTION (1) M (2) (7) (6) (3) (4) (8) (13) (9) (14) (15) (10) (11) (12) (5) (16) 1) Display Screen 2) Control Panel 3) Louvers 4) Front Grill 5) Drain Plug 6) Handle 7) Remote Control 8) Honeycomb Cooling Media 9) Rear Grill 10) Water Fill Tray 11) Water Tank 12) Castors 13) Carbon Dust Filter 14) Water Level Indicator 15) Detachable Water Tank Latch 16) Power Cord & Plug WARNING -- READ AND SAVE THE AIR COOLER SAFETY & MAINTENANCE GUIDE AND USER MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY DAMAGE AND/ OR IMPAIR ITS OPERATION AND VOID THE WARRANTY. USE & OPERATION CONTROL PANEL Icons on Display Screen 0.5 M 1 4 H L 2 S COOL SWING POWER Cool Power ON / OFF 0.5 1 4 2 Swing Timer Setting M H L S Fan Speed: L - Low M - Medium H - High S - Sleep* TIMER SPEED *Applicable for models with Sleep feature only. FUNCTION BUTTONS POWER Press the POWER button to turn the unit on. The cooler will start automatically at medium speed. After a few seconds the speed will switch to low. To turn the unit off, press the button again. SPEED Press the SPEED button repeatedly to change the speed between H - M - L - S*. The indicator light will show the selected speed: High (H) Medium (M) Low (L) Sleep (S)* When the SLEEP mode is selected, the fan will run on High for one hour, then Medium for the second hour and on Low speed from the third hour onwards until you switch off the unit. 1

USE & OPERATION (CONTINUED) FUNCTION BUTTONS (CONTINUED) TIMER Press the TIMER button until the desired time duration setting is selected. When the set time has passed, the unit will automatically turn off (unit remains in Standby mode until power cord is unplugged from electrical socket). The TIMER function allows you to program the unit for up to 7.5 hours of use. SWING Press the SWING button until is illuminated on the display screen. The louvers will begin to move left to right automatically. Vertical Air Flow - You can manually adjust the louvers to change vertical air flow. LOUVER MOVEMENT COOL Press the COOL button until is illuminated on the display screen. This activates evaporative cooling. The water pump will operate and you will feel the cooler air after the Honeycomb Cooling Media is completely wet. WARNING: Please ensure sufficient water is in the water tank otherwise you may hear a Low Water Alarm and the cooler will start in a Fan only mode without evaporative cooling. REMOTE CONTROL Power : ON / OFF Speed : Low / Medium / High / Sleep* Cool : Evaporative cooling ON/OFF Swing : Controls the motion of the louvers Timer : Controls the Timer function for automatic off *Applicable for models with Sleep feature only. Note: The remote control requires a CR2032 (1 x 3V) coin type or equivalent battery for replacement. Open the battery compartment at the back of the remote control and insert battery inside. Care must be taken to insert the batteries according to the correct polarity (+ / ) markings shown inside the battery compartment. Always point the remote control signal transmitter towards the unit when operating. Make sure that the signal path is not obstructed. Remove the batteries if the unit is not going to be used for an extended period of time. Do not drop the remote control. Do not mix different types of batteries such as alkaline, carbon-zinc, or rechargeable batteries. Do not mix old and new batteries. Exhausted batteries are to be removed from the product. Do not dispose of batteries in fire. Batteries may explode or leak. 2

USE & OPERATION (CONTINUED) COOLER LOCATION Make sure to position the air cooler correctly before you set up and start using the product. Please refer to the COOLER LOCATION section of the separate Safety & Maintenance Guide. FILLING WITH WATER CAUTION: Unplug the unit from the electrical power outlet before emptying or refilling the water tank. Open the Water Fill Tray located at the back of the unit. The Water Level Indicator is located at the side of the unit. Refill the water tank when water level is low. Do not fill water above the "Max." water level mark. Check the water level in the tank before running the COOL function. Make sure that the water in the tank is above the minimum water level mark. Running the unit in COOL mode with inadequate water may cause pump failure. LOW WATER ALARM The unit is equipped with a low water sensor. In Cooling Mode, when water in the tank is below the minimum level, you will hear a beeping sound and the will flash continuously. The unit will automatically pause evaporative cooling. Refill the water tank to deactivate the alarm in cooling mode. First switch OFF the unit and unplug from the power outlet. Fill the water tank with water above the minimum water level mark. Plug in and switch ON again. To deactivate the alarm and continue using the unit as a fan (without evaporative cooling), switch the unit OFF and then ON again. The Low Water Alarm will not activate in Fan only mode. The Low Water Alarm will sound again if the COOL function is activated while the water tank is still empty. CLEANING & DRAINING THE WATER TANK Below are instructions on how to clean and maintain your air cooler. If the cooler will not be used for a long period of time, please refer to the STORAGE & MAINTENANCE GUIDELINES located in the separate Safety & Maintenance Guide. WARNING: Before cleaning the unit, switch the unit OFF and disconnect from the electrical socket. Move the unit to a location where the water can be drained. Remove the cap from the Drain plug located at the bottom of the unit. Allow the tank to empty. Detach the water tank by unlocking the Detachable Water Tank Latches on both sides of the unit. Lift the cooler upwards away from the base and place it carefully and vertically on the floor. Be careful not to bend the water pump tubes and other parts that will hang from the bottom of the unit when the body is removed from the tank. Refill the water tank with clean water and drain it completely. Clean the water tank with dish detergent or a damp cloth and rinse it thoroughly. Refill the water tank with clean water, up to the maximum level. Replace the top of the air cooler carefully back onto the tank and lock the side latches. The air cooler is now ready to be used. Use a damp cloth to remove dirt and dust from the surface of the unit. Never use corrosive elements or chemicals to clean this product. When the product is not in use, store the unit in a dry place out of direct sunlight. 3

USE & OPERATION (CONTINUED) CLEANING THE CARBON DUST FILTER* AND HONEYCOMB COOLING MEDIA Figure 1: The appliance is supplied with a Carbon Dust Filter* and Honeycomb Cooling Media. The Carbon Dust Filter* and Honeycomb Cooling Media are located inside the Rear Grill. See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance. Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank and refill with fresh water, especially if the tank has not been cleaned in a long time. 1. The cleaning frequency for the Honeycomb media depends 2. 3. on local air and water conditions. In areas where the mineral 4. content of water is high, mineral deposits may build up on the unit. Honeycomb Cooling Media and restrict air flow. Draining the 5. water tank and refilling with fresh water at least once a week will help reduce mineral deposits. If mineral deposits remain on the Honeycomb Cooling Media, the media should be removed and washed under fresh water. The media should be cleaned every two months or sooner, depending on your needs. For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off. Honeycomb Cooling Media Honeycomb Frame Carbon Dust Filter Screws Rear Grill Removing the Carbon Dust Filter*/ Honeycomb Cooling Media: Remove all the screws from the Rear Grill of the Air Cooler. Carefully pull out the rear grill from the cooler. Slide out the Carbon Dust Filter* and clean with water. To release the Honeycomb Media, remove the Honeycomb Frame screws and pull the Honeycomb Frame out of the Remove the screws on the base of the Honeycomb Frame and slide out the Honeycomb Cooling media. Replace or clean media with water and a damp cloth as needed. WARNING: DO NOT operate the Air Cooler when the Rear Grill is removed from the Air Cooler, or if there is a loose-fitting Rear Grill. Doing so can cause serious injury or dangerous electrical shock. *Applicable for models with Carbon Dust Filter only. 4

JMATEK North America LLC Mahwah, New Jersey 07495 USA Phone: 1-800-474-2147 Email: usinfo@jmatek.com Web: www.jmatek.com Made in China 2015 JMATEK Limited. All rights reserved. The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representations or warranties with respect to this product. This product is manufactured by JMATEK Limited.