Preparing for Medical Physics Components of the ABR Core Examination

Similar documents
Running head: OBESITY AND MEDICAL IMAGING 1. Obesity and Medical Imaging. November 13, 2012

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Prepublication Requirements

INTRODUCTION. A. Purpose

Breast MRI Quality Control

SOP #: Revision #: Current Version Implementation Date: Page #: Page 1 of 10 Last Reviewed/Update Date: Expiration

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

First floor, Main Hospital North Services provided 24/7 365 days per year

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Quality control of CT systems by automated monitoring of key performance indicators: a two-year study

Emory University RT to Bachelor of Medical Science Degree Medical Imaging

Standards for accreditation of educational programs and approval of continuing education courses.

Radiologic Technology (RAD, CLE) courses are open only to Radiologic Technology majors.

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

The Field. Radiologic technologists take x-rays and administer nonradioactive materials into patients' bloodstreams for diagnostic purposes.

Consultation. Review of the scopes of practice for registration in the profession of medical radiation technology

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

Clinic. ED Trauma Trauma Stroke. OR Neuro/Spine. Critical Care. Neuro ENT. Diagnostic. Pediatric. Radiology. Plastics Thoracic. Neuro.

Radiation Safety Issues for Radiologic Technologists

COLLEGE ON MEDICAL PHYSICS

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

SITE IMAGING MANUAL ACRIN 6698

Production of X-rays and Interactions of X-rays with Matter

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

WHERE IN THE WORLD JILL LIPOTI?

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Radiologic Technology Program

Cabrillo College Catalog

Cirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact:

Patient Prep Information

Page: 1 of 6 Page: 1 of 6

X-ray (Radiography) - Bone

Quality Control and Maintenance Programs

C A M P E P. Standards for Accreditation of Graduate Educational Programs in Medical Physics

ABHES BULLETIN. Subject: Final Radiologic Technology Standards Effective January 1, 2013

C1 Medical Imaging Modalities & Characteristics Linwei Wang

IAC Ch 41, p.1. Procedure means a stereotactically guided breast biopsy performed on a patient for diagnostic purposes.

5 Factors Affecting the Signal-to-Noise Ratio

Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology

AN ACT RELATING TO HEALTH CARE; AMENDING THE MEDICAL IMAGING AND RADIATION THERAPY HEALTH AND SAFETY ACT TO EXEMPT EXPANDED

U.S. Bureau of Labor Statistics. Radiology Tech

AAPM REPORT NO. 42 THE ROLE OF THE CLINICAL MEDICAL PHYSICIST IN DIAGNOSTIC RADIOLOGY

ACR AAPM TECHNICAL STANDARD FOR DIAGNOSTIC MEDICAL PHYSICS PERFORMANCE MONITORING OF MAGNETIC RESONANCE IMAGING (MRI) EQUIPMENT

RESPONSE BY THE CEO OF ARPANSA TO THE ADVICE ON MEDICAL RADIATION ISSUES from the RADIATION HEALTH AND SAFETY ADVISORY COUNCIL

Physics testing of image detectors

Diagnostic Exposure Tracking in the Medical Record

Equipment. Lin muyan. Presented by: CocticaUwititonze Cell:+250 (0)

King Fahd University of Petroleum & Minerals. Graduate Bulletin

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

COMMUNICATING RADIATION RISKS IN PAEDIATRIC IMAGING

Comparison of Medical and DOE Health Physics Programs. Kevin Lee Radiation Safety Officer Palmetto Health

Imaging Technology. Diagnostic Medical Sonographer, Dosimetrist, Nuclear Medicine Technologist, Radiation Therapist, Radiologic Technologist

Security Imaging Systems (X-Ray): Design, Measurements Regulations, and Standards

GE Healthcare. DoseWatch. Gathering Radiation Dose Data

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

Whitepapers on Imaging Infrastructure for Research Paper 1. General Workflow Considerations

Moving Forward What does this mean for the Medical Physicist and the Imaging Community?

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Patient Dose Tracking for Imaging Studies. David E. Hintenlang, Ph.D., DABR University of Florida

RADIOLOGY HOUSE STAFF MANUAL

X-Rays Benefits and Risks. Techniques that use x-rays

ACR AAPM SIIM PRACTICE PARAMETER FOR DIGITAL RADIOGRAPHY

PET Accreditation Program Requirements

PET/CT QC/QA. Quality Control in PET. Magnus Dahlbom, Ph.D. Verify the operational integrity of the system. PET Detectors

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

X-ray Imaging Systems

X-ray (Radiography) - Abdomen

Albany Medical Center Chief Medical Physicist Radiation Oncology Imaging and Related Services

I.7. SOFT TECHNIQUE STILL IN USE IN CHEST RADIOGRAPHY PROS AND CONS

CAR Standards for Teleradiology

MEDICAL DOSIMETRY. COLLEGE OF APPLIED SCIENCES AND ARTS Graduate Faculty: therapy.

Fluoroscopy and Radiation Safety Content for Radiologists Marta Hernanz Schulman MD, FAAP, FACR Keith Strauss, M.Sc Ishtiaq H. Bercha, M.

QUALITY CONTROL IN DIAGNOSTIC RADIOLOGY

SUMMARY OF CURRENT UK LEGISLATION AND GUIDELINES

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

Understanding Digital Modalities: System Integration and Use

CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

Monitoring Patient Radiation Dose in VA. Charles M. Anderson MD, PhD Chief Consultant for Diagnostic Services Veterans Health Administration

Radiologic Science Degree Completion Program Assessment Report

The Radiologic Technology Program at Trenholm University

Best Practices in Digital Radiography

Radiography Frequently Asked Questions

Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology

Irradiation Field Size: 5cmX5cm 10cmX10cm 15cmX15cm 20cmX20cm. Focus-Surface Distance: 100cm. 20cm Volume of Ion Chamber : 1cmX1cmX1cm

Bon Secours St. Mary s Hospital School of Medical Imaging Course Descriptions by Semester 18 Month Program

Nuclear Medicine Accreditation Program Requirements

General requirements. 1. Administrative Controls.

Transcription:

Preparing for Medical Physics Components of the ABR Core Examination The ABR core examination for radiologists contains material on medical physics. This content is based on the medical physics that is used in practice by working radiologists in academic and private practice. Thus the best preparation for the exam is to learn to use medical physics in your routine practice. If you do that well you should have no problems with the medical physics on the CORE examination. This material is also included in the certifying and MOC examinations so that this knowledge will be useful both in practice situations and for preparation for the certifying and MOC examinations. It is the position of the ABR and virtually all professional organizations that an understanding of this material is crucial to the safe and effective practice of radiology. We recognize, however, that candidates would like additional guidance to assist them with preparation for the examination. While it is impossible to provide the detail on the content that many candidates would desire, this document explains how the material is structured and how the candidate should prepare for the examination during their years of residency. An important disclaimer is that each exam form is a sample of all of the practice areas, so there is some variation from one exam to another in the details of the exam content. Physics Content Each column of the grid contains material on basic medical physics,the underlying principles of medical physics that apply to that area of radiology, effective use, safety and artifacts. Basic Content The purpose of examining the candidate about fundamentals is to determine that the candidate has knowledge of: Medical Imaging Informatics Image Perception (Psychophysics) Characterization of Medical Images and Basic Image Processing Fundamentals of the Generation, Attenuation and Detection of Ionizing Radiation Radioactive Materials and Radioactive Decay Processes Radiobiology Preparation for the physics content of the CORE examination Page 1

Ionizing Radiation Effects Fundamentals of the Generation, Transmission and Attenuation of Ultrasound Fundamentals of Magnetic Resonance Questions in the basic section are designed to determine if the candidate understands how these issues affect the everyday practice of radiology. Emphasis is on principles rather that the memorization of facts that are not directly relevant or that could be easily looked up on Google or in the Wikipedia. For example there would be no questions about the: λν = c, relationship as it applies to electromagnetic radiation since there is no practical application in radiology. However, that same relationship, as it applies to ultrasound, is of interest since it affects resolution and penetration of the ultrasound. Fundamental questions make up about 20% of the medical physics questions and are distributed into all of the columns of the matrix. While the exam as a whole is strongly image-rich, some fundamental medical physics questions are not easily expressed in an image-rich form EXAMPLES of Basic Items 1. If the x-ray tube voltage is increased from 60 to 70 kvp, how would milliampereseconds (mas) need to be adjusted to maintain a similar amount of radiation exposure to the image detector? A. Reduce mas by ¼ B. Reduce mas by ½ C. Increase mas by ¼ D. Increase mas by ½ 2. If the physical half-life and biologic half-life for a radiopharmaceutical are both equal to 6 hours, what is the effective half-life? A. 1 hour B. 3 hours C. 6 hours D. 12 hours Modality Based Questions The rest of the medical physics questions in each of the columns of the matrix are based on the imaging modalities used in that column. These are approximately as shown in Figure 1. Preparation for the physics content of the CORE examination Page 2

Figure 1: The approximate distribution of medical physics questions by imaging modality in each of the categories. On the average the distribution of modality questions on the exam is as shown in Fig 2. Please again note that this is a general guide and there is significant variation from exam to exam. Figure 2: Approximate distribution of medical physics questions by category/modality on the CORE Exam. Preparation for the physics content of the CORE examination Page 3

Category Based Questions Major Focus of the Items These category/modality questions are very image rich and are divided into four main types: Underlying medical physics principles for the category/modality in question Application of medical physics in the effective use of the category/modality Safety related to the particular category/modality Understanding the causes and methods to reduce artifacts associated with a particular category/modality These questions are distributed approximately as shown in Figure 3. Figure 3: Distribution of the category/modality specific questions Underlying Technology and Physics Principles Every imaging modality has underlying technology and physics principles that must be understood by a radiologist so that the radiologist can understand and interpret the images that are produced by the modality. For example a radiologist needs to understand the relationship between radiation attenuation and Hounsfield numbers to understand how CT images are presented. The questions in the underlying technology and physics principle group focus on these areas. EXAMPLES of Underlying Technology and Physics Principles Items Preparation for the physics content of the CORE examination Page 4

1. The quality or penetrating power of a diagnostic x-ray beam can be increased by which of the following actions? A. Increasing the kilovolt peak B. Decreasing the beam filtration C. Increasing milliampere-seconds D. Decreasing the exposure time 2. To minimize geometric unsharpness, this radiograph should be acquired with which of the following geometric configurations? A. Hand directly on image receptor B. Hand on table Bucky surface C. Hand midway between image receptor and x-ray tube D. Hand near exit of collimator assembly Preparation for the physics content of the CORE examination Page 5

Application of Medical Physics to the Effective Use of the Modality Each imaging modality has certain characteristics that the radiologist must understand in order to create effective protocols, help technologists adjust imaging technique and compensate for pediatric or obese patients. For example increasing the amount of a PET radiopharmaceutical to an obese patient often degrades the image. The questions in this section focus on how the characteristics of the medical physics features of modality and the requirements of category relate to give optimal images. EXAMPLES of Effective Use of the Modality Items 1. This image of the ACR MR accreditation phantom illustrates a wrap-around artifact. What is a possible action to correct the artifact? A. Inverting the frequency and phase directions B. Keeping all image parameters the same and using a larger coil C. Increasing the image repetition time D. Increasing the field of view 2. In a multislice fast-spin-echo (FSE) pulse sequence (TE/TR = 100/4000 ms, ETL = 12, field of view [FOV] = 30 cm, 256x256), which of the following modifications would further reduce the imaging time? A. Reducing the TE to 50 ms B. Reducing the FOV to 25 cm C. Reducing the ETL to 10 D. Reducing the TR to 3000 ms Preparation for the physics content of the CORE examination Page 6

Safety as it Relates to Specify Modalities and Categories While there is a general quality and safety category on the CORE exam there are also safety questions as they relate specifically to medical physics in each category and modality. These questions address issues like avoiding epilation in diffusion CT, specific concerns about appropriate power levels for OB ultrasound and avoiding burns in MRI. These safety questions are tied specifically to the technology used. Questions about safety principles and medical safety are in other sections of the exam. EXAMPLES of Safety as it Relates to Specify Modalities Items 1. A measure of radiation damage to an organ in humans is described by which of the following? A. Activity B. Exposure C. Kerma D. Equivalent dose 2. Patient burns in MRI are usually associated with which of the following? A. Long TR pulse sequences B. Loops in EKG leads C. Patient touching wall of scanner D. Patients weighing less than 20 kg 3. Interventional procedures may on occasion cause skin injuries. Those that typically result in non-healing skin ulcers requiring surgical repair usually occur when the skin dose for a single port exceeds: A. 1 Gy B. 5 Gy C. 10 Gy D. 15 Gy Preparation for the physics content of the CORE examination Page 7

Artifacts All imaging techniques have artifacts that are associated with the technique. Radiologists need to be able to recognize these artifacts, separate them from abnormalities and be able to recommend to technologists how to modify the imaging procedure to minimize them. The artifact-related questions will ask the candidate to identify the artifact, to distinguish the artifact from normal or abnormal findings on the image and to recommend strategies to reduce or eliminate the artifact. EXAMPLES of Artifact-Related Items 1. In the computed radiography (CR) image, what is the most likely cause of the artifact indicated by the arrow? Image from: Cesar LJ et al, 2001, Artifacts found in computed radiography, BJR 74: 195-202. A. Debris on the CR reader light guide B. Debris on the CR imaging plate C. A line of dead pixels D. Grid lines 2. In the CT image of the head, what is the most likely cause of the streak artifact? Preparation for the physics content of the CORE examination Page 8

A. Partial volume effect B. Wrong reconstruction filter C. Low kilovolt peak selection D. Partial data loss Summary The medical physics content on the CORE exam is intended to reflect the medical physics that is commonly encountered by radiologists in image interpretation, executing procedures, and consulting with colleagues, staff and patients. The exam avoids classical physics topics. It addresses basic material only to the extent that fundamental knowledge is necessary to practice effectively. It avoids questions about basic physics facts. Like all parts of the exam, the physics questions are image rich and ask the candidate to make judgments. Preparation for the physics content of the CORE examination Page 9