Zehnder Novus 300. Ventilation unit

Similar documents
Zehnder Focus 200. Ventilation device

How To Get A Passive House

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Comfosystems Systems with heat recovery for a comfortable indoor climate

CE6500 Energy Recovery Ventilator

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Innovent LASER Packaged Fresh Air Conditioning Units

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Material test chamber with mechanical convection

FTXS. Wall Mount Heat Pump or Cooling Only

Combi Unit Genius. The energy efficient Building Service Centre

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

How To Make Your House Breathe

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

Bring the fresh in. Dedicated Outside Air Systems

Heating oven with mechanical convection

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Incubator with mechanical convection

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Lesson 36 Selection Of Air Conditioning Systems

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Heating oven with mechanical control

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

USER S MANUAL HSC-24A

Pool Dehumidification Basics

Technical data. Danfoss DHP-A

The compact unit series

eq Top/TopMaster Air Magic by Fläkt Woods

You make dreams a reality. We provide the efficient Air-Conditioning.

air conditioners how to choose a cooling system

saving energy in comfort Factsheet Recair Enthalpy

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

REMOTE CONTROL MANUAL

ComfoAir 550 Luxe Manual

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice

Under sill units. Type FSL-B-ZAS

Installation and maintenance instructions. Danfoss Vent

The Benefits Really Add Up

Low Cost. Lower Energy Costs. Higher Efficiency.

HEATER, AIR CONDITIONING AND VENTILATION

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Failure code manual. content

User Manual: C Long Point Houston, TX Facebook.com/CoolAZone Twitter.com/CoolAZone

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Mistrale. Fusion Terminal

HVAC Processes. Lecture 7

Installation, operation and maintenance manual TX 35A

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Top Technology for Industry, Agriculture, Business and Communities

Comfort and superior energy efficiency through intelligent home automation

FTQ. Daikin Inverter Ducted Heat Pump

Operating instructions

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Vacuum drying oven for non-flammable solvents

FLAT TECHNICAL DATA. HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS. indoor air quality and energy saving ENERGY CLASS B A A B A A UNIT

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Operation and Installation Manual. Max Series

HDA

DUCT TYPE AIR CONDITIONER

Horizontal ventilation units

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Basic Technology Series

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

FOXAIR 60/50 ALL MODELS

ComfoAir 350 Luxe User Manual

FCQ. Roundflow Cassette Heat Pump or Cooling Only

ECOCIAT. Domestic hot water heat recovery unit

WHOLE-HOUSE VENTILATION SYSTEMS

KONRAD. Hybrid Fancoil Series

BEDIENUNGSANLEITUNG Tieftemperaturheizkörper. MANUAL Low temperature radiator. NOTICE D UTILISATION E2 Radiateur basse température

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

york air-conditioning products Residential & VRF News 2015

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

How to choose a heat pump and use it wisely

squrboxbox heat recovery squrboxbox I technical information

Energy Efficiency HOSPITALITY.

Operating Instructions Split System Air Conditioner

Create the right atmosphere with renewables.

Elements of Energy Efficiency in Data Centre Cooling Architecture

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

CRAC Precision climate control units for data centres

Important Safeguards

TIPS ON ENERGY SAVING

How to choose a heat pump and use it wisely

ROTEX gas hybrid heat pump. A strong team.

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

- White Paper - Data Centre Cooling. Best Practice

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Home Energy Evaluation Report

Transcription:

Use The Zehnder Novus (F) 300 comfort ventilation device was specially developed for use in demanding residential and commercial buildings. It combines maximum comfort, simple operation and high efficiency with flexible integration in building services. The Zehnder Novus (F) 300 ventilation device moves up to 177 cfm of air at an external pressure of 0.8 "wc. Efficiency The integrated counterflow-duct heat exchanger achieves efficiencies up to 95%. For user comfort this means: No unpleasant draft effects because the supply air is heated almost to room temperature even at outside temperatures around freezing. Fans Supply/extract fans are maintenance-free 230 VAC radial fans with integrated power supply and electronic switching. The fans run at a constant volume flow to keep the air volume constant at any selected fan speed. The air volume is not affected even if the filters become soiled. Supply air and extract air settings can be made separately for each fan level in increments of 1% from 29-177 cfm. Filters The Zehnder Novus (F) 300 ventilation unit is fitted with class G4 filters (Merv 7/8) as standard for outside air and extract air. An optional F7 pollen filter (MERV 13) is available for outside air. Installation The Zehnder Novus (F) 300 ventilation unit is characterised by its compact design. All air connections are located on the top of the unit. The unit can be mounted either vertically or horizontally on a wall or a mounting frame. As the design of the unit means that it can be supplied in a left-hand or right-hand version, installation is flexible and air ducts can be routed exactly where they are needed. Control and operation The ventilation unit is controlled and operated using the control unit, which is usually installed in the main living area of the home. The high-quality TFT touch panel with colour display and intuitive user guidance provides the means for control and operation via a touch screen and optimises communication with the ventilation unit. Maintenance To maintain the Zehnder Novus (F) 300, users simply have to change the integrated filters in the front of the unit regularly (every 6 months) and visually inspect the heat exchanger. The heat exchanger should be cleaned at least every 2 years (more often if it gets very dirty). This can be done by simply removing the heat exchanger from the device and cleaning it with soapy water. Please see the unit manual for additional servicing tasks. TS251-1

Frost protection The unit must be installed in a frost-free location. The Zehnder Novus (F) 300 is equipped with automatic protection against freezing. This prevents the heat exchanger from freezing should the outside air temperature drop to a very low level. If the outside air temperature or the supply air temperature at the unit drops below the threshold value, the fans will shut down temporarily. A suitable means of frost protection specifically for the unit can be connected upstream to heat the outside air (during winter). Bypass During summer nights and in the transition periods with strong sunshine the house often becomes too warm while the outside air remains pleasantly cool. In this case heat removal by what is known as "free cooling" helps: The cooler outside air is supplied to the rooms in the living area bypassing the heat recovery system. The Zehnder Novus (F) 300 ventilation unit is equipped with a sensorcontrolled motorised bypass valve for this purpose. The bypass is a standard component and takes 100% of the return air past the heat exchanger. Options Humidity recovery Unit versions with a humidity heat exchanger are available as alternatives to the standard heat exchanger. The optional enthalpy exchanger (Zehnder Novus F 300) is fitted with an anti-microbial polymer membrane which is capable of recovering both heat and significant humidity. There is no risk of odours, germs or other particles being transferred during the physical process of humidity recovery. Pollen filter A large pollen filter installed in the supply air line keeps the inside of the house pollen-free and reduces the particulate, spore and germ load: breathe freely in times of increasing allergies. TS251-2

Benefits Comfort ventilation up to 300 m 3 /h Heat recovery with an efficiency of up to 95% Humidity recovery with enthalpy exchanger (optional) Low power consumption thanks to the high energy efficiency of the ventilation unit (0.23 Wh/m³) Low noise level (21 db(a) 3 m away from the unit) Automatic 100% summer bypass Frost protection controller (including protection against the downstream hot water heating element icing over) Quick, safe installation and maintenance Easy operation with intuitive colour TFT touch panel Filter replacement indicator Preheater and postheater integration possible Small minimum air volume, designed specifically for residential buildings Set up for operation in conjunction with heat-producing appliances Automatic controller for external air quality sensors Article numbers L = supply air left, R = supply air right, V = preheater Luxe = advanced control Description Article number Reference number Novus 300 L 527 001 980 93 35 Novus 300 L Enthalpy 527 002 010 93 77 Tender text Zehnder Novus (F) 300 comfort ventilation unit with plastic counterflow-duct heat exchanger with thermal efficiency of up to 95% optional: counterflow humidity heat exchanger with selective polymer membrane film, supply and extract fans with separate variable control in 1% increments, EC fans with constant volume flow control, automatically controlled integrated 100% bypass, maximum air volume up to 177 cfm at 0.8 "wc, H x W x D: 38.5 x 31.2 x 23.7 inch, left-hand/right-hand vertical/ horizontal design, unit with universal controller for automatic timers or sensors, function to monitor filter running time, frost protection control, communication unit to control preheater and postheater, geothermal heat exchanger flap. Extract air Supply air Outside air Exhaust air Air directions The figures on the right show air directions when looking from above. A = extract air B = supply air C = exhaust air D = outside air Left-hand unit version Outside air Extract air Exhaust air Supply air Right-hand unit version TS251-3

Technical specifications Dimensions Height (inch) 38.5 Width (inch) 31.2 Depth (inch) 23.7 Specification Heat exchanger material - Plastic (counterflow-duct heat exchanger) - Polymer (humidity heat exchanger) Interior lining material Expanded polypropylene (EPP) Heat output up to 95% Weight 110.2 lb Dimensional drawing TS251-4

Certificates Passivhaus (passive house) Equipment Equipment Novus 300 Novus F 300 Enthalpy exchanger x Left-hand/right-hand design x x DN 125 connector x x Ready to plug in design x x TFT touch panel control unit x x Control Fan levels: STANDBY, ABSENT, LEVEL 1, LEVEL 2, LEVEL 3 Fan levels can be programmed separately for supply air and extract air for each fan level in 1% increments (35-118 cfm) Weekly timer programme can be customised Automatic sensors (CO 2, humidity, air quality) optional with external sensor Digital ON/OFF interface (e.g. external contact for OFF) Option to connect intermittent ventilation sensor Filter running time monitoring Frost protection controller (including protection against the downstream hot water heating element icing over) Unit set up for operation in conjunction with a heat-producing appliance Error messages Running time monitoring (separate for fans/unit) Power consumption in standby < 1 W Options (with add-on module) Triggering of an external defroster heater Triggering of a heating circuit or air reheating register Triggering of an electric butterfly valve on the geothermal heat exchanger TS251-5

TS251-6

Technical specifications Sound, supply air Sound power at the supply air connection at a distance of 0 ft. Ventilation unit Volume flow Type cfm 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Novus 300 118 57 53 58 61 54 48 42 Novus 300 177 60 59 63 66 62 56 52 Sound, extract air Sound power at the extract air connection at a distance of 0 ft. Ventilation unit Volume flow Type cfm 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Novus 300 118 36 42 37 31 22 17 15 Novus 300 177 42 50 38 37 28 21 16 TS251-7

Ventilation unit Passivhaus Institut Dr. Wolfgang Feist Rheinstraße 44/46 D-64283 Darmstadt Certificate valid until 31.12.2011 PHI Component suitable for Passive Houses: Heat recovery unit Manufacturer: Paul Wärmerückgewinnung GmbH Name of product: novus 300 The criteria are valid for the cool temperate climate. 1) Passive House Thermal Comfort Criterion: A minimum supply air temperature of 16.5 C is achieved at an ambient temperature of 10 C. Reasoning: In Passive Houses there is no need to install radiators on exterior walls. In order to avoid discomfort due to exposure to cold air, the supply air temperature must not sink below a minimum value. 2) Efficiency Criterion (heat): The effective dry heat recovery rate, determined at an ambient air temperature between -15 and 10 C, dry extraction air (21 C) and with balanced mass flows, must be greater than ηhr,t,eff 75% 3) (in this case 93 % [200 m³/h], 94,4 % [145 m³/h]). Efficiency Criterion (electricity): The unit's total specific electric power consumption for the operating levels applied in Passive Houses must not exceed 0,45 W/(m³/h), for the supply air delivered at design mass flow (in this case 0,24 Wh/m³ [145 m³/h], 0,23 Wh/m³ [200 m³/h]). 4) Air-tightness and thermal insulation: The interior and exterior air leakage flow rates must not exceed 3 % of the nominal extraction air flow rate. (Requirements and verification are described in the certificate s appendix.) 5) Balancing and controllability: (Requirements and verification are described in the certificate s appendix.) 6) Sound insulation: The installation in a separate room for building services is required for this unit. The required sound pressure level of 35 db(a) in the installation space with an equivalent absorption area of 4 m² is not achieved. The unit has to be set up in a separate room. sound levels of < 25 db(a) in living spaces and < 30 db(a) in functional spaces are achieved with sound absorbers. (Requirements and verification are described in the certificate s appendix.) 7) Room air hygiene: An outdoor air filter F7 is integrated in the unit. If the unit and all components are installed and operated according to the manufacturer s instructions, the unit will provide perfectly hygienic supply air. (Requirements and verification are described in the certificate s appendix.) 8) Anti-freeze protection: (Requirements and verification are described in the certificate s appendix.) The certificate is to be used as follows: COMPONENT suitable for PASSIVE HOUSES Dr. Wolfgang Feist Heat recovery unit: Heat recovery rate (effective): 93 % Electric efficiency: 0,24 Wh/m³ Zehnder America, Inc. 540 Portsmouth Ave. Greenland, NH 03840 USA T +1 603 422 6700 Toll Free: 888 778 6701 F +1 603 422 9611 info@zehnderamerica.com www.zehnderamerica.com CDE-FLYERTS251, V0112, en, subject to changes The following criteria were checked for the award of this certificate: