CHILLED-WATER, FOUR-PIPE (CHW) SYSTEM

Similar documents
The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

HEATING, VENTILATION & AIR CONDITIONING

EnergyPro Building Energy Analysis. Assisted Living Building

HVAC Systems: Overview

White Paper: Residential HVAC Split System Basics

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Mechanical Systems Proposal revised

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Chilled Water HVAC Systems

Selection Tips For Air-Conditioning Cooling Systems

Heating & Cooling Efficiency

Air-Conditioning Buying Guide

HVAC Processes. Lecture 7

Energy Efficiency in Industrial HVAC Systems

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

Cast Iron Radiator Heating Capacity Guide

ENHANCED LABORATORY HVAC SYSTEM

Commissioning - Construction Documents (Page 1 of 6)

RFI Response RFP: HSCG88-16-R-PQQ015 Replace HVAC Bldg A & C San Diego, CA.

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Innovent LASER Packaged Fresh Air Conditioning Units

Defining Quality. Building Comfort. Precision. Air Conditioning

Section 2: Estimating Energy Savings and Incentives

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Drives and motors. A guide to using variable-speed drives and motors in retail environments

CoolTeg Plus Chilled Water (CW) version: AC-TCW

How a Ground Source Heat Pump Works for Commercial Buildings

CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning)

Glossary of Heating, Ventilation and Air Conditioning Terms

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

Energy Efficiency. Energy Efficient Home Cooling:

Printing and Publishing Energy Savings Guide

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

2014 Quality Home Comfort Award Winner: Clean Slate Leads to

123 street Salt Lake City, Utah 84092

HVAC Claims: Repair vs. Replacement

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

air conditioners how to choose a cooling system

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

How To Design A Building In New Delhi

How Ground/Water Source Heat Pumps Work

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air. Trevor Wende Vice President, Marketing Advantix Systems, Inc.

Ductless Heat Pumps for Passive Houses

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Creating Efficient HVAC Systems

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Daikin VRV Retrofit Provides Comfortable, Quiet Rooms for Residents

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

Glossary of HVAC Terms

Lesson 36 Selection Of Air Conditioning Systems

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

White Paper #10. Energy Efficiency in Computer Data Centers

GEOTHERMAL HEATING APPLICATIONS FOR RESIDENTIAL HOMES

Energy Efficient Homes: Air Conditioning 1

CEILING CASSETTE FAN COIL UNIT

Topics for Today. Order of Magnitude Mechanical Estimating. Order of Magnitude Estimate Goal. Project Delivery Methods. Questions for Client

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

The ABC s of VRF: A Green HVAC Technology An Ideal Green School Solution. Presented by: Fujitsu General America, Inc.

Building Energy Systems. - HVAC: Heating, Distribution -

INNOVATION. PERFORMANCE. SAVINGS. ENERGY STAR Makes It Simple. ROOM AIR CONDITIONERS 2007 PARTNER RESOURCE GUIDE

Why is my air conditioner dripping on my customers?

THREE. Heating and Cooling

Chris Clement 701 Bayou Lane Thibodaux, LA

KONRAD. Hybrid Fancoil Series

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

Optimization of Water - Cooled Chiller Cooling Tower Combinations

heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.

Originators of the Flexible Water Tube design

BVCAA inc HVAC Service Bid Sheet Item Description. Materials Labor Total 3/24/2015

Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency. Randy Mead, C.E.M, CMVP

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

The Different Types of Air Conditioning Equipment for IT Environments

Preliminary Final Proposal

Condensing Boiler Efficiency

The efficient heat pump

Mechanical Insulation. Hospitals and Schools

Energy Saving Fact Sheet Boilers

Building Re-Tuning Training Guide: AHU Heating and Cooling Control

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Nordic Heat Pump Product Guide

VRF Zoning: An Ideal HVAC Solution for Multifamily Applications

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

Air Conditioners. A cool, comfortable solution to take you to a higher standard of comfort. READ ONLY

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

"I'm a Daikin Comfort Pro"

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

PTAC Selection Guide. Optimize your spend with the right PTAC equipment!

Transcription:

WOJCIESZAK & ASSOCIATES, INC. CONSULTING ENGINEERS 833 EAST 5 TH STREET STUART, FLORIDA 34994 (772) 286-8696 TECHNICAL BULLETIN NO. DATE REVISION 202 04/25/06 2 CHILLED-WATER, FOUR-PIPE (CHW) SYSTEM Constraints 1. House square footage 10,000 SQ. FT. or more 2. Smallest zone 250 SQ. FT. System Description Chilled-water systems can be installed in residences over 10,000 square feet, however, because of the high initial cost, they are commonly found in residences 30,000 square feet and above. This system provides the most flexibility and has been described as providing a high level of comfort. The high level of comfort is achieved because of the system s ability to maintain nearly constant temperature and humidity levels within the house. Artwork, decorations and interior finishes are well preserved in this type of indoor climate and could be the reason some residences under 30,000 square feet have chilled-water systems. The chilled water is produced by large compressors inside a chiller. One or two chilled-water pumps pump the 45F chilled-water to the air handling units that sit in mechanical closets. The air handling units consist of a fan, a chilled water coil, and a hot water coil. The fan blows the room air over the chilled-water coil and delivers cold air to the room. This process warms up the chilled-water to about 55F. The chilled-water is pumped back to the chiller. A cooling tower is used, like in the water-cooled heat pump system, to provide cooling for the chiller s compressors. Condenser water is pumped to the cooling tower. The cooling tower has a fan that blows air across this water and cools the water before it returns back to the compressor. The hot water coil inside the air handler has 140F to 160F water circulating through it. The fan blows room air over the coil and delivers the warmed air to the room. The hot water is cooled by about 10F and it is pumped back to the boiler where it is heated back up. The hot water coil also serves to dehumidify the space as needed. Estimated Costs Obtain from an HVAC contractor. Notes: 1. Equipment Replacement Frequency Cooling tower fan motor (every 4-5 years) Cooling tower (every 10-15 years) Chilled water pumps inside (every 10-15 years) Condenser water pumps outside (every 5-7 years) Boiler outside (every 5-10 years) Boiler pumps outside (every 5-7 years) Air Handling Units (every 15-20 years) Chiller (every 20 years) Indoor Equipment 1. Air Handling Unit (AHU) a. Typical mechanical closet/room size 2-ton 48 x 42 3-ton 48 x 56 4-ton 49 x 56 5-ton 49 x 62 b. Since there is only a fan and hot and chilled water coils, the chilled-water AHU is relatively quiet. c. Location of equipment should be in areas where service personnel can easily access the equipment, via hallways in lieu of bedroom closets, for example. Filter changing and coil cleaning are routine maintenance. d. For added comfort, two speed fans can be used for the AHU fan. The slow speed will provide a comfortable environment while the space is below maximum capacity; whereas the high speed can provide adequate cooling for maximum capacity. 2. Chiller and Chilled-Water Pumps a. The chiller and pumps should be located inside a room far away from the main living/sleeping areas. Particular attention should be given to sound-proofing this room.

WOJCIESZAK & ASSOCIATES, INC. CONSULTING ENGINEERS 833 EAST 5 TH STREET STUART, FLORIDA 34994 (772) 286-8696 TECHNICAL BULLETIN NO. DATE REVISION 202 04/25/06 2 CHILLED-WATER, FOUR-PIPE (CHW) SYSTEM b. Indoor mechanical room dimensions: SQ. FT. Length Width Height 10,000 15 9 8 15,000 15 9 8 20,000 18 10 8 30,000 18 10 8 40,000 18 10 8 50,000 20 12 8 60,000 22 12 8 70,000 22 12 9 3. It is best to locate the pumps for condenser water inside the building. This shelters the equipment from the harsh outdoor environment, thus extending its useful life. The pumps run continuously, therefore it makes it important to carefully locate this equipment and sound proof the room. Pumps may be located outside if no interior space is available. 4. A boiler is used to heat the condenser water and provide heating on cool days. It too may be located inside to be protected from the weather, but air for combustion has to be provided as well as flue venting for the flue gases. If no room is available inside, it may be located outside. Outdoor Equipment 1. Cooling Tower a. Typical cooling tower size SQ. FT. Length Width Height 10,000 7-0 4-2 6-7 15,000 11-0 4-2 5-2 20,000 11-0 4-2 6-7 30,000 15-0 4-2 6-7 40,000 18-0 4-2 6-7 50,000 18-0 4-2 6-7 60,000 15-0 7-10 6-7 70,000 15-0 7-10 6-7 b. Because of the size of the cooling tower, a large space on the property is necessary. Although there are several options available for noise reduction, the tower should be located far away from the residence or sound sensitive outdoor areas of the property. Local codes may limit the noise levels at adjacent property lines. 2. Overall Outdoor Equipment Pad Size SQ. Length Width Height FT. 10,000 11 9 7 15,000 15 9 6 20,000 15 9 7 30,000 19 9 7 40,000 22 9 7 50,000 22 9 7 60,000 19 12 7 70,000 19 12 7 Piping Chilled water piping is typically copper insulated with 2-inch thick foamglass insulation. Care should be made to locate piping in accessible locations above the ceiling where the insulation can be repaired when it wears out (15-20 years). The piping can also be run under ground and under the slab when welded steel is used. Condenser water piping is generally PVC underground and copper above ground and does not require insulation. It is usually run above the ceiling. Humidity Control Humidity control is available through the hot water coil on the air handling unit. The hot and chilled water coils work together to dry out the air. Energy Consumption Energy consumption is quite low in systems of 100 tons or more. However, in the smaller systems, there is not much difference between the chilled-water and water-cooled heat pump systems.