Configuring the HP DL380 Gen9 24-SFF CTO Server as an HP Vertica Node. HP Vertica Analytic Database



Similar documents
HP reference configuration for entry-level SAS Grid Manager solutions

HP recommended configuration for Microsoft Exchange Server 2010: ProLiant DL370 G6 supporting GB mailboxes

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

How To Write An Article On An Hp Appsystem For Spera Hana

HP ProLiant BL660c Gen9 and Microsoft SQL Server 2014 technical brief

HP high availability solutions for Microsoft SQL Server Fast Track Data Warehouse using SQL Server 2012 failover clustering

Implementing Red Hat Enterprise Linux 6 on HP ProLiant servers

HP recommended configurations for Microsoft Exchange Server 2013 and HP ProLiant Gen8 with direct attached storage (DAS)

QuickSpecs. What's New HP 1.2TB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

HP ProLiant DL580 Gen8 and HP LE PCIe Workload WHITE PAPER Accelerator 90TB Microsoft SQL Server Data Warehouse Fast Track Reference Architecture

QuickSpecs. HP SAS Enterprise and SAS Midline Hard Drives Overview

HP RA for SAS Visual Analytics on HP ProLiant BL460c Gen8 Servers running Linux

QuickSpecs. HP Integrity Virtual Machines (Integrity VM) Overview. Currently shipping versions:

HP Client Virtualization SMB Reference Architecture for Windows Server 2012

QuickSpecs. What's New HP 750GB 1.5G SATA 7.2K 3.5" Hard Disk Drive. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

HP Smart Array Controllers and basic RAID performance factors

QuickSpecs. What's New HP 3TB 6G SAS 7.2K 3.5-inch Midline Hard Drive. HP SAS Enterprise and SAS Midline Hard Drives. Overview

QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview

QuickSpecs. HP SATA Hard Drives. Overview

How to register. Who should attend Services, both internal HP and external

Performance brief for IBM WebSphere Application Server 7.0 with VMware ESX 4.0 on HP ProLiant DL380 G6 server

Performance characterization report for Microsoft Hyper-V R2 on HP StorageWorks P4500 SAN storage

HP ProLiant DL380p Gen mailbox 2GB mailbox resiliency Exchange 2010 storage solution

HP ConvergedSystem 900 for SAP HANA Scale-up solution architecture

QuickSpecs. HP SATA Hard Drives. Overview

Microsoft Windows Server 2003 with Internet Information Services (IIS) 6.0 vs. Linux Competitive Web Server Performance Comparison

HP PCIe IO Accelerator For Proliant Rackmount Servers And BladeSystems

Performance and Recommended Use of AB545A 4-Port Gigabit Ethernet Cards

The Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment

VTrak SATA RAID Storage System

HP ProLiant Gen8 vs Gen9 Server Blades on Data Warehouse Workloads

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler

QuickSpecs. What's New. At A Glance. Models. HP StorageWorks SB40c storage blade. Overview

Configuring HP Elite, EliteBook, and Z220 systems for Intel Smart Response Technology

Oracle Database Scalability in VMware ESX VMware ESX 3.5

HP SN1000E 16 Gb Fibre Channel HBA Evaluation

Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities:

Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays. Red Hat Performance Engineering

QuickSpecs. HP Smart Array 5312 Controller. Overview

QuickSpecs. HP Serial-ATA (SATA) Entry (ETY) and Midline (MDL) Hard Drive Option Kits. Overview

QuickSpecs. HP SATA Hard Drives. Overview

RAID 5 rebuild performance in ProLiant

Redundancy in enterprise storage networks using dual-domain SAS configurations

Desktop virtualization: Implementing Virtual Desktop Infrastructure (VDI) with HP. What is HP Virtual Desktop Infrastructure?

Performance Comparison of Fujitsu PRIMERGY and PRIMEPOWER Servers

QuickSpecs. What's New Boot from Tape. Models HP Smart Array P411 Controller

Configuring and using DDR3 memory with HP ProLiant Gen8 Servers

Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation

Models Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers

Intel RAID SSD Cache Controller RCS25ZB040

1. Specifiers may alternately wish to include this specification in the following sections:

Brainlab Node TM Technical Specifications

s/n item Requirements 1 Upgrading of Network Core Switches and Microsoft Servers Virtualization

HP ProLiant DL380 G5 High Availability Storage Server

Use cases and best practices for HP StorageWorks P2000 G3 MSA FC/iSCSI Combo Controller

How System Settings Impact PCIe SSD Performance

HP Blade Workstation Solution FAQ

This chapter explains how to update device drivers and apply hotfix.

QuickSpecs. What's New Support for two InfiniBand 4X QDR 36P Managed Switches

RSA Security Analytics Virtual Appliance Setup Guide

QuickSpecs. What's New Dual Port SFF 10K and 15K SAS drives Dual Port 3.5" 15K SAS drives. HP SAS Drives (Servers) Overview

Cisco Unified Computing System Hardware

Power Redundancy. I/O Connectivity Blade Compatibility KVM Support

QuickSpecs. HP StorageWorks Modular Smart Array 500 G2. Overview

This user guide describes features that are common to most models. Some features may not be available on your computer.

Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM)

HP DDR4 SmartMemory Is finding reliable DRAM memory for your HP ProLiant Server series in your data center a major challenge?

HP Cloudline Overview

Cisco for SAP HANA Scale-Out Solution on Cisco UCS with NetApp Storage

How To Build A Cisco Ukcsob420 M3 Blade Server

HP Universal Database Solution: Oracle and HP 3PAR StoreServ 7450 All-flash array

HP Moonshot System. Table of contents. A new style of IT accelerating innovation at scale. Technical white paper

How To Compare Two Servers For A Test On A Poweredge R710 And Poweredge G5P (Poweredge) (Power Edge) (Dell) Poweredge Poweredge And Powerpowerpoweredge (Powerpower) G5I (

HP StorageWorks P2000 G3 and MSA2000 G2 Arrays

Microsoft Exchange Server 2007 and Hyper-V high availability configuration on HP ProLiant BL680c G5 server blades

QuickSpecs. PCIe Solid State Drives for HP Workstations

Configuration Guide February 2015

Microsoft Windows Server 2003 vs. Linux Competitive File Server Performance Comparison

Copyright 2013, Oracle and/or its affiliates. All rights reserved.

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

Cisco MCS 7825-H3 Unified Communications Manager Appliance

MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220

Adaptec: Snap Server NAS Performance Study

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

Sizing guide for Microsoft Hyper-V on HP server and storage technologies

HP 85 TB reference architectures for Microsoft SQL Server 2012 Fast Track Data Warehouse: HP ProLiant DL980 G7 and P2000 G3 MSA Storage

Performance Evaluation of VMXNET3 Virtual Network Device VMware vsphere 4 build

DD670, DD860, and DD890 Hardware Overview

Power efficiency and power management in HP ProLiant servers

Certification: HP ATA Servers & Storage

HP Common Slot power supply technology

Comparing the performance of the Landmark Nexus reservoir simulator on HP servers

Using HP StoreOnce Backup Systems for NDMP backups with Symantec NetBackup

DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering

SAN TECHNICAL - DETAILS/ SPECIFICATIONS

Introduction to MPIO, MCS, Trunking, and LACP

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION

Transcription:

Configuring the HP DL380 Gen9 24-SFF CTO Server as an HP Vertica Node HP Vertica Analytic Database HP Big Data Foundations Document Release Date: February, 2015

Contents Using the HP DL380 Gen9 24-SFF Server as an HP Vertica Node... 3 Recommended Software... 3 Selecting a Server Model... 3 Selecting a Processor... 3 Selecting Memory... 3 Selecting and Configuring Storage... 4 Drive Bay Population... 5 Protecting Data on Bulk Storage... 5 Hpsa Device Driver for HP Smart Array Controllers... 5 Data RAID Configuration... 5 Linux I/O Subsystem Tuning... 6 Data RAID Configuration Example... 6 Selecting a Network Adapter... 7 HP ROM-Based Setup Utility (BIOS) Settings... 8 Alternate Part Appendix... 10 Processor... 10 Memory... 10 Disk Drives... 10 Networking... 11 2

Using the HP DL380 Gen9 24-SFF Server as an HP Vertica Node The HP Vertica Analytics Platform software runs on a shared-nothing MPP cluster of peer nodes. Each peer nodes is independent, and processing is massively parallel. An HP Vertica node is a hardware host configured to run an instance of HP Vertica. This document provides recommendations for configuring an individual DL380 Gen9 24-SFF CTO Server as an HP Vertica node. The recommendations presented in this document are intended to help you create a cluster with the highest possible HP Vertica software performance. This document includes a Bill of Materials (BOM) as a reference and to provide more information about the DL380 Gen9 24-SFF CTO Server. Recommended Software This document assumes that your services, after you configure them, will be running the following minimum software versions: Vertica 7.1 Enterprise Edition. The Vertica 7.1 version implements a new I/O profile to best use the enhanced capabilities of a modern hardware platform like the Proliant Gen9. As such, Hewlett-Packard recommends using HP Vertica 7.1 (or later) Enterprise Edition. Red Hat Enterprise Linux 6.x. Recommending Red Hat Linux is not an indication of that Hewlett-Packard has a preference for this product over other supported Linux distributions. The purpose of this recommendation is solely to enhance discussion points in this document. Selecting a Server Model The HP DL380 Gen9 product family includes several server models. The model that Hewlett-Packard recommends for maximum HP Vertica software performance is the DL380 Gen9 24-SFF CTO Server (part number 767032-B21). Selecting a Processor For maximum price/performance advantage on your HP Vertica database, the DL380 Gen9 24-SFF servers used for HP Vertica nodes should include two (2) Intel Xeon E5-2690v3 2.6 GHz/12-core DDR4-2133 135W processors. This processor recommendation is based on the fastest 12-core processors (or optionally 14-core processors) available for the DL380 Gen9 24-SFF platform at the time of this writing. These processors allow HP Vertica to deliver the fastest possible response time across a wide spectrum of concurrent database workloads. The processor s faster clock speed directly affects the HP Vertica database response time. Additional cores enhance the cluster s ability to simultaneously execute multiple MPP queries and data loads. Selecting Memory For maximum HP Vertica performance, DL380 Gen9 24-SFF servers used as HP Vertica nodes should include 256 GB of RAM. Configure this memory as follows: 8 x 32 GB DDR4-2133 RDIMMs, 1DPC (32 GB per channel) In the field, you can expand this configuration to 512 GB by adding 8 x 32 GB DIMMs. A two-processor DL380 Gen9 24-SFF server has 8 memory channels with 3 DIMM slots in each channel, for a total of 24 slots. DL380 Gen9 24-SFF memory configuration should comply with DIMM population rules and guidelines: Do not leave any channel completely blank. Load all channels similarly. Populate the maximum number of DIMMS per channel (DPC) to 2. Doing so allows you to use the highest supported DIMM speed of 2133 MHz. DPCs with 3 DIMMs run at 1866 MHz or lower. Note: Hewlett-Packard recommends that you follow these guidelines to avoid a reduction in memory speed that could adversely affect the performance of your HP Vertica database.

The preceding recommended memory configuration is based on 32 GB DDR4 2133 MHz DIMMs and 256 GB of RAM. That configuration is intended to achieve the best memory performance while providing the option of future expansion. The following table provides several alternate memory configurations: Sample Configuration Total Memory Considerations 8 x 16 GB DDR4-2133 RDIMMs 1 DPC (8 GB per channel) 128 GB A low-memory option for systems with less concurrency and slower speed requirements. 16 x 16 GB DDR4-2133 RDIMMs 2 DPC (16 GB, 16 GB per channel) 8 x 32 GB DDR4-2133 RDIMMs 1 DPC (32 GB per channel) 24 x 16 GB DDR4-2133 RDIMMs 3 DPC (16 GB, 16 GB, 16 GB per channel) 16 x 32 GB DDR4-2133 RDIMMs 2 DPC (32 GB + 32 GB per channel) 24 x 32 GB DDR4-2133 LRDIMMs 3 DPC (32 GB, 32 GB, 32 GB per channel) (LR-DIMM) 256 GB 256 GB 384 GB 512 GB 768 GB A slightly less expensive option for 256 GB of RAM that does not allow expansion in the field. The standard memory recommendation for HP Vertica. A higher memory option, but with lower memory speed of 1866 MHz. This selection does not allow for expansion in the future. A high-memory option that may be beneficial to support some database workloads. A LR-DIMM memory option, a high memory option but with lower memory speed. This selection does not allow for expansion in the future. Selecting and Configuring Storage Configure the storage hardware as follows for maximum performance of the DL380 Gen9 24-SFF server used as an HP Vertica node: 1x HP DL380 Gen9 24-SFF CTO Chassis with 24 Hot Plug SmartDrive SFF (2.5-inch) Drive Bays 1x HP DL380 Gen9 2-SFF Kit with 2 Hot Plug SmartDrive SFF (2.5 inch) Drives Bays (on the back of the server) 1x Embedded HP P440/2 GB Flash Backed Cache SAS Array Controller (integrated on system board) 2x 300 GB 6G SAS 10 K 2.5 inch SC ENT drives (configured as RAID1 for the OS and the Vertica Catalog location) 24x 1.2 TB 6G SAS 10 K 2.5 inch SC ENT drives (configured as one RAID 1+0 device for the Vertica Data location, for approximately 13 TB total formatted storage capacity per HP Vertica node) You can configure an HP Vertica node with less storage capacity: Substitute 24x 12 TB 6G SAS 10 K 2.5 inch SC ENT drives with 24x HP 600 GB 6G SAS 10 K 2.5 inch SC ENT drives. Configure the drives as one RAID 1+0 device for the HP Vertica data location, for approximately 6 TB of total data storage capacity per HP Vertica node. Alternatively, you can configure the 23 rd and 24 th 1.2 TB (or 600 GB) data drives (for 22 active drives in total) as hot spares. However, such configuration is unnecessary with a RAID 1+0 configuration. HP Vertica can operate on any storage type. For example, HP Vertica can run on internal storage, a SAN array, a NAS storage unit, or a DAS enclosure. In each case, the storage appears to the host as a file system and is capable of providing sufficient I/O bandwidth. Internal storage in a RAID configuration offers the best price/performance/availability characteristics at the lowest TCO. An HP Vertica installation requires at least two storage locations one for the operating system and catalog, and the other for data. Place these data locations on a dedicated, contiguous-storage volume. HP Vertica is a multithreaded application. The HP Vertica data location I/O profile is best characterized as large block random I/O. 4

Drive Bay Population The 26 drive bays on the DL380 Gen9 24-SFF servers are attached to the Smart Array P440 Controller over 4 internal SAS port connectors (through a 12 G SAS Expander Card) as follows: Ports 1, 2, 3 Drive bays 1 8, 9 16,17 24 (8 drives each) Port 4 Drive bays 25 and 26 (2 drives) Important: For best storage performance, distribute I/O distributed across the three SAS physical links used for data as evenly as possible (the 8 drive ports). For example, an ideal implementation of the recommended 26-drive configuration is: 300 GB drives placed in bays 25 and 26, with the 2SFF drive expander in the rear of the server. 1.2 TB (or 600 GB) drives placed in all bays on the front of the server. This approach spreads the Vertica data RAID10 I/O evenly across the three SAS groups. Admittedly, with 24 drives for data, pursuing a perfectly balanced physical placement of drives may be desirable but not critical. However, if DL380 Gen9 24-SFF servers have substantially fewer drives (18 or less), loading the SAS links evenly is essential to avoid a storage performance bottleneck. Protecting Data on Bulk Storage The HP Smart Array P440ar Controller offers the optional HP Secure Enctyption capability that protects data at rest on any bulk storage attached to the controller. (Additional software, hardware, and licenses may be required.) For more information, see HP Secure Encryption product details. Hpsa Device Driver for HP Smart Array Controllers Note: The information in this section is a best practices recommendation. Starting with Red Hat Enterprise Linux (RHEL) 6, the new Hpsa SCSI driver is the default driver for newer HP Smart Array controllers like the Gen9 P440. The main change visible to users is that the logical RAID devices are named sda, sdb, sdc, and so on. Unlike its cciss driver predecessor, hpsa presents logical disk devices in the standard SCSI namespace. This change greatly improves compatibility with system tools and utilities designed to work with SCSI storage. The latest versions of Linux includes the hpsa driver. More information about the SCSI drivers is available in the white paper, "Migrating to hpsa". Data RAID Configuration The 24 data drives should be configured as one RAID 1+0 device as follows: The recommended strip size for the data RAID 1+0 is 256 K, which is the default setting for the P440 controller. The recommended Controller Cache (Accelerator) Ratio is 10/90, which is the default setting for the P440 controller. The logical drive should be partitioned with a single primary partition spanning the entire drive. Place the HP Vertica data location on a dedicated physical storage volume. Do not co-locate the HP Vertica data location with the HP Vertica catalog location. Hewlett-Packard recommends that the HP Vertica catalog location on an HP Vertica node on a DL380 Gen9 24-SFF server be the operating system drive. You do not need to perform any special operating system/hp Vertica catalog drive configuration or tuning. For more information, read Before You Install HP Vertica in the product documentation, particularly the discussion of HP Vertica storage locations. Note: HP Vertica does not support storage configured with the Linux Logical Volume Manager in the I/O path. This limitation applies to all Vertica storage locations including the catalog which is typically placed on the OS drive.

Linux I/O Subsystem Tuning To support the maximum performance DL380 Gen9 24-SFF node configuration, Hewlett-Packard recommends the following Linux I/O configuration settings for the HP Vertica data location volumes: The recommended Linux file system is ext4. The recommended Linux I/O Scheduler is deadline. The recommended Linux Readahead setting is 8192 512-byte sectors (4 MB). The current configuration recommendations differ from the previously issued guidance due to the changes in the Vertica I/O profile implemented in HP Vertica 7. System administrators should durably configure the deadline scheduler and the read-ahead settings for the Vertica data volume so that these settings persist across server restarts. Caution: Failing to use the recommended Linux I/O subsystem settings will adversely affect performance of the HP Vertica software. Data RAID Configuration Example The following configuration and tuning instructions pertain to the HP Vertica data storage location. Note: The following steps are provided as an example, and may not be correct for your machine. Verify the drive numbers and population for your machine before running these commands. 1. View the current storage configuration: % hpacucli ctrl all show config detail 2. Assume that the RAID1 OS drive is configured as a logical drive 1 and the 24 data drives are either loose or preconfigured into a temporary logical drive. To create a new logical drive with recommended parameters, any non-os logical drives must be destroyed, and content will be lost. To destroy a non-os logical drive: % hpacucli ctrl slot=0 ld 2 delete forced 3. Create a new RAID10 data drive with 256 K strip size: % hpacucli ctrl slot=0 create type=ld raid=1+0 ss=256 drives=1i:1:1,1i:1:2,1i:1:3,1i:1:4,1i:1:5,1i:1:6,1i:1:7,1i:1:8,2i:1:9,2i:1:10, 2I:1:11,2I:1:12,2I:1:13,2I:1:14,2I:1:15,2I:1:16,3I:1:17,3I:1:18,3I:1:19,3I:1:2 0,3I:1:21,3I:1:22,3I:1:23,3I:1:24 4. Partition and format the RAID10 data drive: % parted -s /dev/sdb mklabel gpt mkpart primary ext4 0% 100% % mkfs.ext4 /dev/sdb1 5. Create a /data mount point, add a line to the /etc/fstab file, and mount the HP Vertica data volume: % mkdir /data [add line to /etc/fstab]: /dev/sdb1 /data ext4 defaults 0 0 % mount /data 6. So that the Linux I/O scheduler Linux Read-Ahead, and hugepage defragmentation settings persist across system restarts, add the following five lines to /etc/rc.local file: echo deadline > /sys/block/sdb/queue/scheduler blockdev --setra 8192 /dev/sdb echo never > /sys/kernel/mm/redhat_transparent_hugepage/enabled echo never > /sys/kernel/mm/redhat_transparent_hugepage/defrag echo no > /sys/kernel/mm/redhat_transparent_hugepage/khugepaged/defrag 7. After you have configured the storage, run vioperf to understand the baseline I/O performance. The minimum required I/O is 20 MB/s read and write per physical processor core on each node. This value is based on running in full duplex, reading and writing at this rate simultaneously, concurrently on all nodes of the cluster. The 6

recommended I/O is 40 MB/s per physical core on each node. For example, the I/O rate for a server node with 2 hyperthreaded 6-core CPUs is a required minimum of 240 MB/s. Hewlett-Packard recommends 480 MB/s. For more information, see vioperf in the product documentation. Selecting a Network Adapter To support the maximum performance MPP cluster operations, DL380 Gen9 24-SFF servers used as HP Vertica nodes should include at least two (2) 10 Gigabit Ethernet (RJ-45) ports: HP Ethernet 10 Gb 2-port 561FLR-T Adapter in the FlexibleLOM slot Alternatively, if you need SFP+ networking, DL380 Gen9 24-SFF servers used as HP Vertica nodes should include at least two (2) 10 Gigabit Ethernet (SFP+) ports. HP Ethernet 10 Gb 2-port 530FLR-SFP+ Adapter in the FlexLOM slot An HP Vertica cluster is formed with DL380 Gen9 24-SFF servers, associated network switches and HP Vertica software. When used as an HP Vertica node, each DL380 Gen9 24-SFF server should be connected to two separate Ethernet networks: The private network, such as a cluster interconnect, used exclusively for internal cluster communications. This network must be the same subnet, dedicated switch or VLAN, 10 Gb Ethernet. HP Vertica does TCP P2P communications and UDP broadcasts on this network. IP addresses for the private network interfaces must be assigned statically. No external traffic should be allowed over the private cluster network. The public network is used for database client (i.e., application) connectivity, should be 1 Gb Ethernet or better. A 10-Gb Ethernet is suggested for workloads including high-volume data transfers between the database server cluster and connecting applications. HP Vertica has no rigid requirements for public network configuration. However, Hewlett- Packard recommends that you assign static IP addresses for the public network interfaces. The private network interconnect should have Ethernet redundancy. Otherwise, the interconnect (specifically the switch) would be a single point of a cluster-wide failure. Cluster operations are not affected even in the event of a complete failure of a public network. Thus, public network redundancy is not technically required. However, if a failure occurs, the application connectivity to the database is affected. Therefore, consider public network redundancy for continuous availability of the entire environment. To achieve redundancy on both the private and public networks: 1. Take the two ports from the Ethernet card on the server and run one to each of the two top of rack switches (which are bonded together in an IRF). 2. Bond the links together using LACP. 3. Divide the links into public and private networks, using VLANs. Configuring the Network The following figure illustrates a typical network setup that achieves high throughput and high availability. (This figure is for demonstration purposes only.) This figure shows that the bonding of the adapters allows for one adapter to fail without the connection failing. This bonding provides high availability of the network ports. Bonding the adaptors also doubles the throughput. Furthermore, this configuration allows for high availablility with respect to the switch. If a switch fails, the cluster does not go down. However, it may reduce the network throughput by 50%.

HP ROM-Based Setup Utility (BIOS) Settings Hewlett-Packard recommends changing the following Power Management Options from the default values for best performance: Option Recommended Setting Explanation HP Power Profile Maximum Performance Enabling Maximum Performance disables all power management options that could negatively affect performance. HP Power Regulator Advanced Power Management Options Collaborative Power Control HP Static High Performance Mode Disable Enabling the HP Power Regulator allows processors to run in the maximum power and performance state, regardless of the operating system management policy. HP Static Power Regulator modes are ignored under RHEL6 and SLES11 on ProLiant Gen8 Servers with an Intel Processor. This is a known Linux issue. For more information, see the HP Customer Advisory. Additionally, you must modify the kernel entry in the /etc/grub.conf file, as the following figure shows. (Append intel_idle.max_cstate=0 and processor.max_cstate=0 to the kernel line.) 8

ProLiant DL380 Gen9 24-SFF Bill of Materials The following table contains a sample Bill of Materials (BOM). Note the following about this BOM: Part numbers are listed for reference only. Networking equipment and racks are not included. All hardware requests should come through the CSE team for review. HP Quantity Part Number Description Notes 1 767032-B21 HP DL380 Gen9 24-SFF CTO Server 1 719044-L21 HP DL380 Gen9 E5 2690v3 FIO Kit For 12 cores 1 719044-B21 HP DL380 Gen9 E5 2690v3 Kit For 12 cores 8 26722-B21 HP 32GB 4Rx4 PC42133P-L Kit For 256 GB of memory 1 727250-B21 HP 12GB SAS Expander Card 1 727258-B21 HP DL/ML/SL 96W Smart Storage Battery 1 724864-B21 HP DL380 Gen9 2SFF Kit 1 SG506A HP C13-C14 2.5ft Sgl Data Special 1 SG508A HP C13-C14 4.5 Sgl Data Special 1 768896-B21 HP DL380 Gen9 Rear Serial Cable Kit 1 726736-B21 HP Smart Array P440ar/2G Controller

2 652564-B21 HP 300GB 6G SAS 10K 2.5in SC ENT HDD 24 718162-B21 HP 1.2TB 6G SAS 10K 2.5in SC ENT HDD 1 647581-B21 HP Ethernet 10GbE 530FLR SFP+ Adapter For operating system and database catalog For approximately 13 TB formatted storage capacity For SFP+ networking 2 720479-B21 HP 800W FS Play Ht Plg Pwr Supply Kit 1 733660-B21 HP 2U SFF Easy Rail Kit Alternate Part Appendix Processor Quantity Part Number Description Notes 1 719045-L21 HP DL380 Gen9 E5 2697v3 FIO Kit 14 cores at 2.6 GHz 1 719045-B21 HP DL380 Gen9 E5 2697v3 Kit 1 719044-L21 HP DL380 Gen9 E5 2690v3 FIO Kit 12 cores at 2.6 GHz 1 719044-B21 HP DL380 Gen9 E5 2690v3 Kit Memory Quantity Part Number Description Notes 8 726722-B21 HP 32GB 4Rx4 PC4 2133P-L Kit For 256 GB of memory 16 726722-B21 HP 32GB 4Rx4 PC4 2133P-L Kit For 512 GB of memory Disk Drives Quantity Part Number Description Notes 24 718162-B21 HP 1.2TB 6G SAS 10K 2.5in SC ENT HDD 24 652583-B21 HP 600GB 6G SAS 10K 2.5in SC ENT HDD For approximately 13 TB formatted storage capacity For approximately 6 TB formatted storage capacity 10

Networking Quantity Part Number Description Notes 1 647581-B21 HP Ethernet 10GbE 530FLR SFP+ FIO Adapter 1 700699-B21 HP Ethernet 10Gb 2P 561FLR-T Adapter For SFP+ networking For RJ-45 networking

Get connected hp.com/go/getconnected Current HP driver, support, and security alerts delivered directly to your desktop. Copyright 2012, 2013, 2014, 2015 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. 12