Air velocity sensor QVM62.1

Similar documents
SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Digital input modules

Air damper actuators

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

TX OPEN RS232/485 module

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

RRV934. Multi-controller. Synco living

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Flush-mount room temperature sensor AQR2531ANW.

Room Temperature Sensors

Input module, input/output module

Duct Humidity Transmitter

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

PCS0100en Persy Control Services B.V. Netherlands

Flush-mounted room thermostats

Heating Controller. Building Technologies HVAC Products

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Product and functional description

Electronic Control Devices The European Product Catalogue 2007

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

HERZ-Thermal Actuators

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Quick Connect. quick - simple - efficient.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Safety technique. Emergency stop module BO 5988 safemaster

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

PRODUCT PROFILE FEATURES

T0118 T2118 T3118. Instruction Manual

Problem / Solution. The problem:

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

GREISINGER electronic GmbH

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

OZW30. Central Unit SYNERGYR

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

VAV compact controller KNX / PL-Link

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical Data. Dimensions

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Open channel & partially filled pipe Ultrasonic flow meters

RY2 miniature industrial relays

RM4TG20 three-phase network control relay RM4-T - range V

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

How To Use A Flowmeter

ACS-30-EU-EMDR-10-MOD

HMI display Installation Guide

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Capteur température et humidité pour HVAC

Panel Meters and Controllers Modular Panel Meter Type EDM 35

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

EGSTON Standard E2xFxWx 12W

mecotron Safety relay ESTOP-2 For emergency stop monitoring

SYSTEM 4C. C R H Electronics Design

SYSTEM 45. C R H Electronics Design

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Installation, operation and maintenance manual TX 35A

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

PIEZOMETER AIRFLOW MEASURING RING

Product and Application Description

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

IN-OUT Thermometer with Cable Free Sensor and Clock

J TB/TW Temperature limiter, temperature monitor

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Remote Monitoring and REC 501 Control Unit Product Guide

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

E-STOP relays, safety gate monitors

1. Description. 2. List of Accessories included A B C F G H

OZS Web server. For LPB/BSB plants

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Wind Sensor W-RS485 with RS485 Interface

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

Digital inductive conductivity transmitter

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Electronic Control Devices The European Product Catalogue 2007

Electric Rotary Actuator - On/Off or programmable control actuator

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

Transcription:

92 Air velocity sensor QVM62. Use This sensor is used to control the air velocity to a constant value, or to balance out pressure fluctuations (supply or extract air control), or to monitor the flow in air ducts. It primarily is used for modulating fan control in primary plants to set the basic volume flow. Action The QVM62. records the air velocity as a measured value and converts it to an active DC 0...0 V or 4 20 ma output signal. Three measuring ranges are available: 0...5 m/s, 0...0 m/s, and 0...5 m/s. The sensor measures a point, i.e., it measures the values at a specific location in the flow profile. For recording the mean air velocity in the duct, the sensor's immersion depth is the key measure. The immersion depth depends on the flow profile. The measurement principle is based on the anemometric measurement principle. The specially developed thin film sensing element of the QVM62. is to a big extend independent form the flow direction and is nearly insensitive to any kind of dirt in the airflow. Ordering When ordering, indicate the name and type designation : Air velocity sensor QVM62. CMN92en 206-0- Building Technologies

Engineering The air velocity sensor consists of: Immersion stem with sensor head and sensing element Extension pipe with fitting Immersion stem end with flow direction arrow Adjustable connecting flange Transducer Connection cable, screened, four-core, m long A scale with 0.5 cm grating on the immersion stem and the extension pipe indicates the immersion depth. The connecting flange is used to attach and seal the immersion stem on the duct wall. A plastic housing with removable cover accommodates the transducer. It can be screwed to a flat surface. The sensor cable is connected; the sensor and the transducer together represent a unit. The measuring ranges are selected by inserting or removing a plug-in jumper. Protection against false wiring is provided related to own voltages, i.e., measuring output X is short-circuit proof. The sensor head connections are not protected against AC/DC 24 V operating voltage. Wiring and setting elements Terminal block for connection to the immersion stem 2 Terminal block for connection to controller Plug-in unit for setting the three velocity ranges. The following applies: No plug-in jumper = 0 5 m/s Plug-in jumper on and 2 = 0 0 m/s (factory setting) Plug-in jumper on 2 and = 0 5 m/s 4 Terminal block for selection of the output signal: Pos I = DC 4 20 ma Pos U = DC 0 0 V Disposal The devices are considered electronics devices for disposal in terms of European Directive 202/9/EU and may not be disposed of as domestic waste. Dispose of the device via the channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 2/5

Technical data Power supply Measuring data Signal output X Line length Connections Degree of protection Environmental conditions Operating voltage Frequency Power consumption AC/DC 24 V 20 %(SELV) 50/60 Hz 5 VA (max. 200 ma) External supply line protection Fuse slow max. 0 A or Circuit breaker max. A Characteristic B, C, D according to EN 60898 or Power source with current limitation of max. 0 A Measuring ranges, adjustable 0 5 m/s 0 0 m/s (factory setting) 0 5 m/s Measuring accuracy at 20 C, 45 % r.h., 0 hpa 0 5 m/s (0.2 m/s + % of measured value) 0 0 m/s (0.2 m/s + % of measured value) 0 5 m/s (0.2 m/s + % of measured value) Permissible air velocity 20 m/s Direction dependence 0. % of measured value at 0 Time constant t 90 at 0 m/s ca. 4 s Voltage output Current output DC 0 0 V, ma DC 4 20 ma, 0 500 Perm. line length to controller at 0.6 mm dia copper cable 50 m mm 2 copper cable 50 m.5 mm 2 copper cable 00 m Line length to the sensor head m (prewired) Mechanical: screw connection Electric: screw terminal, max. 2.5 mm 2 Protection class III according to EN 6070- Protection degree of housing Transducer IP42 according to EN 60529 Sensor head IP20 according to EN 60529 Operation (transducer and immersion stem) IEC 72-- class K5 Temperature 0 45 C class M2 Chemical conditions class C2 Storage (transducer and immersion stem) IEC 72-- class K Temperature 0 60 C class M2 Transport (transducer and immersion stem) IEC 72--2 class 2K Temperature 25 60 C class 2M2 /5

Materials and colours Standards, directives and approvals Environmental compatibility Weight Housing bottom Housing cover Sensor pipes Sensor head, extension, end Connecting flange Sensor, total polycarbonat, RAL 700 (silver-grey) polycarbonat, RAL 705 (light-grey) polycarbonat, RAL 700 (silver-grey) polycarbonat, RAL 705 (light-grey) polycarbonat, RAL 700 (silver-grey) silicon-free Product standard EN 6070- Automatic electrical controls for household and similar use Electromagnetic compatibility (Applications) For use in residential, commerce, light-industrial and industrial environments EU Conformity (CE) CM2T92xx *) EAC Conformity Eurasia conformity ) The product environmental declaration CME92 *) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). With packaging 0.52 kg *) The documents can be downloaded from http://siemens.com/bt/download. Engineering notes Place the sensor on the measuring path in a location where the air flow is quiet. Thus: do not place it close to dampers, registers, and duct direction changes. 6 x Dg. 6 x x Dg. x 92Z02 92Z0 Use a transformer with safety extra-low voltage (SELV) with separate winding for 00% ON-time. Observe all local safety rules and regulations pertaining to sizing and protecting transformers. Note the permissible line length to the controller. Mounting and installation notes Mount the immersion stem so that the air flows through the opening at the sensor head. The immersion stem is premounted and wired to the transducer on delivery. The sensor pipes and the end with the direction arrow are prearranged on the connecting cable-fit them together (use the direction-oriented snap-on connections). If the extension pipe is not required, remove it from the cable. The connecting flange is not attached on delivery. The sensor is supplied with mounting instructions. Commissioning notes Check the wiring and the air velocity range settings prior to commissioning. Check the immersion stem position in the air duct (mounting instructions!). 4/5

Diagrams G M X Operating voltage AC/DC 24 V Measuring neutral/ operating voltage ground Output signal DC 0 0 V or 4 20 ma Dimensions (All dimensions in mm) 5/5 2000 204 Siemens Switzerland Ltd. Subject to change