TECHNICAL DATA Temperature range...0 C to 125 C Solution...choice 0,5 C or 0,0625 C Accurates. more than +/-0,5 C Log interval...10 sec. to 4 hours Proof... IP68 Measure....Ø35mm * 7mm Lifetime..dependent on use (see Graphs) The curves shows the lifetime when the logger makes loggings, that means to you if example. logging with 0,5 C solution and with a interval with 10sec. And a logtime on one hour, you would make: (100 days * 24 hour) =2400 logging with a average temperature on 50 C (provided that you stopping loggings after one time). The logger is running after programming, and stopped first when loading data. It s important to know for the battery lifetime. (see Graphs) With MicroLog Reader and the belongs PC program you can load the data from the logger and get shown the data both in curveform and like tableform. The software get automatic which COM port the readeren(usb) is placed. The is many analyse and printout possibility in the program and also its Possibillity to zoome logdata grafen and export the data to much example to Excel and convert the data to many differents format types. The data can be shown : Celcius, Fahrenheit, Kelvin or Reumur. CA TEKNIK 9220 Aalborg - Phone: +45 98101050 www.cateknik.dk mail@cateknik.dk 1
Made in Denmark ****************MICROLOG TYPE: 125************* CA TEKNIK 9220 Aalborg - Phone: +45 98101050 www.cateknik.dk mail@cateknik.dk 2
WARRANTY MicroLog temperaturelogger s we give s 1 years warranty on manufacture-errors. When the Microlog runs by a battery, like not can be replaced, and therefor you must buy a new logger, if the battery is running empthy because often use or long use (see the curver s for lifetime), the warranty not will be apply, if the MicroLog temperaturelogger is end to use in this example. The Microlog begin to log when you programming this, and when you load data from the logger, this will stop exactly. If return the logger for replace, you must enclose the ID-INF: with a mail. The warranty also not will apply if there is making visible force, or if the label is removed from the logger. Curver s for lifetime (The time the logger is running from programing by the logger to load of data) Support: mail@cateknik.dk CA TEKNIK 9220 Aalborg - Phone: +45 98101050 www.cateknik.dk mail@cateknik.dk 3
Congratulation with your MICROLOG Temperature Logger. QUICK GUIDE: To work with MicroLog your system should be configured with the following: Software Windows 2000, Windows XP, Server 2003 and Vista + Windows 7 Hardware Pentium 200 MHz or higher 32 MB RAM (64 MB recommended) 10 MB available disk space for the MicroLog application The MicroLog software will first be installed. Follow the on-screen instructions to continue the installation process. CA TEKNIK 9220 Aalborg - Phone: +45 98101050 www.cateknik.dk mail@cateknik.dk 4
Once the MicroLog software has been installed the Silicon Laboratories USB driver installation will begin automatically. The driver is necessary for the computer to detect the MicroLite logger. Follow the on-screen instructions to continue the installation process. The default installation location is C:\SiLabs. CA TEKNIK 9220 Aalborg - Phone: +45 98101050 www.cateknik.dk mail@cateknik.dk 5
When connected to the PC USB port the MicroLog was not detected by the software. Ensure that the USB driver was installed properly. If it is, then you can find com-port, when connected to the USB. Go to Control Panel > Add/Remove Programs (in WinXP), and check that the driver is installed: If not, you must rerun the CP210x driver to install the driver. If the driver is installed, ensure that there is no other device sharing the USB com port with the MicroLog. 1. Once you have installed Microlog program, go to the library where the program is installed and running CP210x_Drivers. (important) 2. Then connect the interface/reader in PC USB 3. Find the communications port (see page 9) 4. Programming the Microlog Ty.125 CA TEKNIK 9220 Aalborg - Phone: +45 98101050 www.cateknik.dk mail@cateknik.dk 6
5. When Programming OK Shows, the logger is running, and will log untill you load data. 6. Before you load data, you can make a path: CA TEKNIK 9220 Aalborg - Phone: +45 98101050 www.cateknik.dk mail@cateknik.dk 7
7. Load Data: CA TEKNIK 9220 Aalborg - Phone: +45 98101050 www.cateknik.dk mail@cateknik.dk 8
***************MICROLOG TYPE: 125************* Attention!!!!!!!!!!!!!!! Com-port info: CA TEKNIK 9220 Aalborg - Phone: +45 98101050 www.cateknik.dk mail@cateknik.dk 9
EXAMPLE from EDIT CA TEKNIK 9220 Aalborg - Phone: +45 98101050 www.cateknik.dk mail@cateknik.dk 10
Options: CAPSULE for MICROLOG Type 70.009.010 Options: Certifikat for Microlog Type: 7000.5002 CA TEKNIK 9220 Aalborg - Phone: +45 98101050 www.cateknik.dk mail@cateknik.dk 11
USB Converter: Type DT-5002 Software on CD latest: Type: 7000.5005 NOTE: CA TEKNIK 9220 Aalborg - Phone: +45 98101050 www.cateknik.dk mail@cateknik.dk 12