Pressure Transducer cerabar T PMP 131

Similar documents
Pressure transmitter For general industrial applications Model A-10

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Conductive Level Switch FK 2 Technical Data:

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electronic Pressure Monitoring New Products

Inductive sensor NI10-M18-Y1X-H1141

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Features. Picture. Specifications

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Relative and absolute pressure switch type 529

How To Use A Flowmeter

Proportional pressure regulators VPPE

Plastic tube flowmeters Series PT/PS

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 3000

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Digital inductive conductivity transmitter

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Technical Data. Dimensions

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Liquid Level Limit Switch liquiphant T FTL 20

Digital Pressure Measuring Instrument MDR480

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Product Catalogue. AP Automatyka ISO ISO OHSAS ISO 9001.

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Temperature Switch Thermophant T TTR 31, TTR 35

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Subminiature Load Cell Model 8417

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Flow switches Series AD/VH

ph/redox Measurement MyPro CPM 431

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Digital display DA 48

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Turbine Flow Sensor Series VTR

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Series 6000 Torque measured metal bellow coupling

Solenoid Valve Island Type 3965

Relative pressure transmitter type 520

3DLevelScanner II TECHNICAL DATA SHEET

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Instruction Manual Differential Pressure Transmitter

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Duct Humidity Transmitter

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Assisted lift operated 2/2-way solenoid valves Type EV250B

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

DPI 260 SERIES: Digital Pressure Indicators

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

LUT Luminescence scanners: Seeing what no-one else can

W150: Miniature photoelectric switch series with completely integrated electronics

4 Posiflow Proportional Solenoid Valves

Control- and feedback head for integrated mounting on Robolux valves Type 2036

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Digital input modules

BOS 73K... BOS 74K...

Electronic overload relay EF19 and EF45

Minicap FTC260, FTC262

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Cross-beam scanning system to detect slim objects. 100 mm in

Technical Information RIA14

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Data Sheet PS1B Pressure Switch

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Redundancy Module QUINT-DIODE/40

2.12. page Products for Explosion hazardous Environment

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Electronic overload relay EF65, EF96 and EF146

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Cable Plug acc. to DIN EN , Form A

Transcription:

Technical Information TI 291P/00/en Pressure Transducer cerabar T PMP 131 Pressure transducer with polysilicon sensor For absolute and gauge pressures up to 400 bar Version available for hazardous areas Application Cerabar T PMP 131 is designed for measuring absolute and gauge pressure of gases, vapours and liquids. Features and Benefits Finely graduated measuring ranges up to 400 bar or 6000 psi Up to 4 times overload resistance Extremely stable Flush diaphragm process connection or manometer connection for ½ BSP (G ½), ¼ BSP (G ¼) or ½ NPT Electronic versions with analogue output 4 20 ma switch output PNP transistor Approved for EEx ib IIC T6 Measuring System Pressure transducer Cerabar T PMP 131 with 4 20 ma output or switch output. Power supply, e.g. RN 221 transmitter power supply unit from Endress+Hauser 4 20 ma Power supply e.g. RN 221 Endress +Hauser The Power of Know How

+ + Operation Zero Point Adjustment For the PMP 131 with analogue output and plug, the zero point can be adjusted to ±5 %. The potentiometer used for this is located below the base of the plug. 1+ 2 4 20 ma Mounting boss Zero Point Adjustment Remove plug Loosen coupling nut Remove mounting boss Do not turn the cap nut when loosening or tightening the base of the plug! Potentiometer for zero point correction ±5 % Switch Point and Hysteresis Adjustment For the PMP 131 with switch output, both the switch point and hysteresis can be adjusted. This can also be carried out at atmospheric pressure using the enclosed test cable and a voltmeter. The potentiometer used for this adjustment is located below the base of the plug. R 1+ 3+ 2 Hysteresis adjustment 1.5 20 % FS (Factory setting: 10 % FS) LED colour code RED = ON GREEN = OFF + Switch Point and Hysteresis Adjustment Remove plug Loosen coupling nut Remove mounting boss Do not turn the cap nut when loosening or tightening the base of the plug! Switch point adjustment 0...100 % FS (Factory setting: 50 % FS) Adjustment without reference pressure: Connect the voltmeter to the test pin 0 1 V corresponds to 0 100% FS 2

Instructions for Switch Point and Hysteresis Adjustment U out ON: red LED Hysteresis 1.5 20 % FS Switch on Switch off OFF: green LED Switch point and hysteresis adjustment FS: Full Span (measuring range) U out : output voltage p: acting pressure Switch point Adjustment 0...100 % p Electrical Connection Plug-in housing red white green + PE Plug-in jack Reference air line Gasket Coupling nut Mounting boss O-Ring left: PMP 131 with plug right: PMP 131 with cable Connector DIN 43 650/A Analogue output 4... 20 ma 2-wire 1 Power supply and output (+) 2 Power supply and output ( ) 3 not assigned Ground (PE) PMP 131 Plug version, assignment 1 3 2 Switch output 3-wire 1 Output (+) 2 Power supply and output ( ) 3 Power supply (+) Ground (PE) 3

Technical Data General specifications Manufacturer Endress+Hauser Instrument designation Cerabar T PMP 131 Application Measuring absolute and gauge pressure of gases, vapours and liquids Function and system design Measuring principle With analogue output With switch output Design Analogue output Switch output The process pressure acting upon the metallic separating diaphragm of the sensor is transmitted to a resistance bridge via a fluid. The change in the output voltage of the bridge is proportional to the pressure and can be measured directly. The process pressure acting upon the metallic separating diaphragm of the sensor is transmitted to a resistance bridge via a fluid. A differential amplifier creates a standard signal from the pressure-proportional change in output voltage of the bridge. A comparator with an adjustable hysteresis compares this signal with the pre-set switch point and then activates the power amplifier and the LED. Pressure sensor is optionally supplied with DIN 43650 A/ ISO 4400 plug or cable Pressure transducer with plug DIN 43650 A/ISO 4400 (see page 3) Input Measured variable Gauge or absolute pressure Measuring ranges Max. 400 bar/6000 psi (see»product Structure«page 6) Output Analogue output 4...20 ma Output signal Load 4 20 ma R B [Ω] (U S 12 V) / 0.02 A, (U S = power supply) Switch output PNP Output signal Output current Power Switch frequency Input resistance / Input current PLC Note Voltage (depends on power supply voltage) Switch status ON: I a 0.5 A Switch status OFF: I a 1mA max. 6 W max. 10 Hz R i 2kΩ or I i 10 ma To prevent electrical interference, inductive loads (relays, contactors or solenoid valves) may only be operated with directly connected to a protective circuit (free-wheeling diode or capacitor). Accuracy Terminal-based linearity including hysteresis and reproducibility (Limit point method to DIN IEC 770) Analogue output: 0,5 % FS Accuracy Switch output 1 % FS for the switch point Reproducibility Switch output 0.5 % FS for the switch output Settling time 2 5 ms Effect of ambient temperature Analogue output Zero: typical 0.2%/10 K, max. 0.5%/10 K of measuring span. Values are 0.1%/10 K higher for measuring spans 6 bar Span: typical 0.2%/10 K, max. 0.5%/10 K of measuring span Switch output Switch output: typical 0.2 %/10K of measuring span Long-term stability typical 0.15 % per year 4

Operating conditions Mounting conditions Any position, flush-mounted for process connection G ½ (Code B): max. torque for mounting 40 Nm Environment Normal operating temperature 25 +70 C ( 13 +158 F), Ex area: 25 +65 C ( 13 149 F) 40 +85 C ( 40 185 F) Storage temperature Climate class 4 Z with Z=70 C to VDI/VDE 3540 Ingress protection With plug: IP 65, with cable: IP 68 Vibrational resistance 4M5 to DIN EN 60721-3 Electromagnetic compatibility Interference emission to EN 61326 electrical device B, interference immunity to EN 61326 appendix A (industrial use) and NAMUR recommendation NE 21 Process Normal process temperature 25 +70 C ( 13 +158 F) Process pressure limits Overload resistance see»product Structure«page 6 Vacuum resistance to 10 mbar absolute Mechanical construction Process connections See Product Structure»Process Connection«page 6 Electrical connection Cable Connection See Product Structure»Version«page 6 and»electrical Connection«page 3 Material of outer covering: PUR, non-flammable to VDE 0472, External diameter: 5.8 mm, Wires: 4 x 0,22 mm², External diameter of air line: 2 mm Plug to DIN 43650 A/ISO 4400, Material: PA Materials for wetted parts Process connection and housing 1.4301 (AISI 304) Process diaphragm 1.4435 (AISI 316 L) Fill fluid Silicone oil AK3 Power Power supply Analogue output Switch output Ripple Analogue output Switch output Non-Ex: 12 30 V DC Ex: no-load voltage 26 V, short-circuit current 100 ma, power consumption 0.8 W 18 32 V DC, current consumption without load < 20 ma, with reverse polarity protection 5% 10 % Certificates and approvals Analogue output: EEx ib IIC T6 EEx ib IIC T6, Zone 0 Supplementary documentation Cerabar T System Information SI 035P/00/en Cerabar T Operating Instructions KA 103P/00/a6 Cerabar T PMC 131 Technical Information TI 279P/00/en EMC test procedures Technical Information TI 241F/00/en 5

Product Structure Version, cable gland, protection A1 Plug (ISO 4400), Pg 11, IP 65 A2 Plug (ISO 4400), ½ NPT, IP 65 A3 5 m (16.4 ft) cable, IP 68 99 Special version Process connection: type and material 1 G ½ (male), DIN 16 288, AISI 304 2 ½ NPT (male), ¼ NPT (female), AISI 304 3 ½ NPT (male), 4 mm (female), AISI 304 4 G ¼ (male), DIN 16 288, AISI 304 5 ¼ NPT (male), 3.5 mm (female), AISI 304 B G ½ (male), DIN 3852-A, AISI 304, flush diaphragm 9 Special version Output signal, certificate 0 Analogue 4 20 ma, 2-wire, for non-hazardous area 1 Analogue 4 20 ma, 2-wire, EEx ib IIC T6 D Analogue 4 20 ma, 2-wire, EEx ib IIC Zone 0 2 Switch output, PNP-Transistor, 3-wire (with plug only) 9 Special version Accessories 1 None 9 Special version Measuring range, unit, pressure type Overload Gauge pressure (bar) (kpa, MPa) A1G 0 1 bar 0 100 kpa 4 bar A1H 0 1.6 bar 0 160 kpa 6.4 bar A1N 0 2.5 bar 0 250 kpa 10 bar A1Q 0 4 bar 0 400 kpa 16 bar A1R 0 6 bar 0 600 kpa 24 bar A1S 0 10 bar 0 1 MPa 40 bar A1T 0 16 bar 0 1.6 MPa 64 bar A1W 0 25 bar 0 2.5 MPa 100 bar A1X 0 40 bar * 0 4 MPa * 160 bar A1Z 0 60 bar * 0 6 MPa * 240 bar A70 0 100 bar * 0 10 MPa * 400 bar A71 0 160 bar * 0 16 MPa * 600 bar A73 0 250 bar * 0 25 MPa * 600 bar A74 0 400 bar * 0 40 MPa * 600 bar Absolute pressure (bar) (kpa, MPa) A2G 0 1 bar 0 100 kpa 4 bar A2H 0 1.6 bar 0 160 kpa 6.4 bar A2N 0 2.5 bar 0 250 kpa 10 bar A2Q 0 4 bar 0 400 kpa 16 bar A2R 0 6 bar 0 600 kpa 24 bar A2S 0 10 bar 0 1 MPa 40 bar A2T 0 16 bar 0 1.6 MPa 64 bar A2W 0 25 bar 0 2.5 MPa 100 bar A2X 0 40 bar 0 4 MPa 160 bar A2Z 0 60 bar 0 6 MPa 240 bar B70 0 100 bar 0 10 MPa 400 bar B71 0 160 bar 0 16 MPa 600 bar B73 0 250 bar 0 25 MPa 600 bar B74 0 400 bar 0 40 MPa 600 bar Gauge pressure (psi) Q4H 0 15 psi g 60 psi Q4K 0 30 psi g 150 psi Q4N 0 50 psi g 240 psi Q4R 0 150 psi g 600 psi Q4S 0 300 psi g 1500 psi Q4T 0 500 psi g * 2400 psi Q4V 0 1000 psi g * 3600 psi Q70 0 1500 psi g * 6000 psi Q73 0 3000 psi g * 9000 psi Q74 0 6000 psi g * 9000 psi Absolute pressure (psi) R4H 0 15 psi a 60 psi R4K 0 30 psi a 150 psi R4N 0 50 psi a 240 psi R4R 0 150 psi a 600 psi R4S 0 300 psi a 1500 psi R4T 0 500 psi a 2400 psi R4V 0 1000 psi a 3600 psi R70 0 1500 psi a 6000 psi R73 0 3000 psi a 9000 psi R74 0 6000 psi a 9000 psi 999 Special range * = Absolute pressure sensors PMP 131 Product designation 6

Dimensions Version Code A1: plug with Pg 11 gland Code A2: plug with ½ NPT gland Code A3: cable 52 L: to 25 bar 126, from 40 bar 131 37 39 79 Ø26 Pg 11 or ½ NPT 27 AF L: to 25 bar 143, from 40 bar 148 54 69 Ø 26 Optional with process connection Code 1: G ½ Code 2: ½ NPT male, ¼ NPT female Code 3: ½ NPT male, 4 mm female Code 4: G ¼ 5 20 15 25 L L L G½ Ø6 ¼ NPT ½ NPT Ø5 G ¼ 3.5 ¼ NPT Code B: G ½ flush diaphragm to DIN 3852-A-G ½ 52 117 70 37 Ø26 3 27 AF G ½ Ø26 Ø27 Ø 21 22 14 54 39 25 12 L Ø4 ½ NPT 3 2.5 Code 5: ¼ NPT male, 3.5 mm female Pg 11 or ½ NPT 134 70 Ø26 Threaded hole DIN 3852-X-G ½ 7

Endress+Hauser GmbH+Co. KG Instruments International P.O. Box 2222 D-79574 Weil am Rhein Germany Tel. (07621) 9 75-02 Fax (07621) 975-345 http://www.endress.com info@ii.endress.com Endress+Hauser The Power of Know How 05.02/PT1 TI 291P/00/en/04.03 SL/CV5