MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

Similar documents
! WARNING. Before using product, read and understand instructions.

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

Air Eliminators and Combination Air Eliminators Strainers

Submersion/Insertion Toroidal Sensor

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Morrison Bros. Co. General Product Specifications

Dissolved Oxygen Sensors

Technical Data. Installation

WAVELET WATER QUALITY MONITORING KIT

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Replacing Displacers with Guided Wave Radar

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

Submersion/Insertion Toroidal Sensor

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

TYPE E Main Valve Sizes 3 /8 through 12

Oil and Coolant Circulating Heating System. Model - OCSM

Self Purging Liquid Trap (SPLT ) User s Manual

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Sanitary and CIP Toroidal Sensor

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Float and Thermostatic Traps Series H, C and X

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Stainless Steel Single and Dual Circulation Kits

Series 510 Submersible Level Transmitters

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

Powers Controls TH 192 S Single Temperature Room Thermostat

Sanitary Type Electronic Flow Switches

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Stainless Steel Valves For the Sanitary Industries

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Toroidal Conductivity Sensor

Model DE-3 Air Release Head

RING JOINT SYSTEMS 207

Screw Plug Immersion Heaters

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Micro Motion Model D and DL Coriolis Flow and Density Meters

Model 43AP Pneumatic Controller, Style B

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Colima Visco and Colima Viscorol Magnetic Level Indicators

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Commercial Electric Water Heater

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Commercial Gas Water Heaters

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

API Flanged Safety Relief Valves Series 526 CATALOG

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Dehumidifier Users manual. For Models: DH45S DH65S

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Light Duty Commercial Electric Water Heater

Pressure Relief Valves SPV, SPVF

Bypass level indicator With magnetic display Model BNA

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Steam Coil Installation, Operation and Maintenance

MODEL G300 BRAKE BLEEDER

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Copper Meter Resetters

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Installation and maintenance instructions

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

300 Series PA Pump and Cooler Assemblies

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

FRL/AirCare Air Controls & Accessories

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

TECHNICAL DATA. Dry 122a. November 12, 2013

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

The Unique Accelabar Flow Meter

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

HYDRAULIC AND LUBE OIL HEATERS HYDRAULIC AND LUBE OIL HEATERS. HL Series. Warren Electric Corporation

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Electronic, Digital and Mechanical Vibration Switches

VG7000 Series Bronze Control Valves

Metal Pressfitting Pipe Systems

Explosion proof enclosures

Installation Manual DIAPHRAGM WELL TANK

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

G234X-55 Conventional Gas Boiler

Accessories for GF and RA machines

BLADDER SURGE CONTROL SYSTEM

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Transcription:

MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2015-03-16 Section 15

In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our specifications and designs at any time. The latest version of this manual can be found at www.fwmurphy.com. CAUTION: MLS Series parts are not interchangeable with other Murphy liquid level products. Damage caused by using incorrect parts is not covered by our Limited Warranty. Please read the following information before installing. A visual inspection for damage during shipping is recommended before mounting. BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT: Disconnect all electrical power to the machine. Make sure the machine cannot operate during installation. Follow all safety warnings of the machine manufacturer. Read and follow all installation instructions. OBSERVE all pressure and electrical ratings and requirements for the devices and the operating environment. BE SURE all pressure HAS BEEN REMOVED from the vessel before opening any pressure connections. Please contact Enovation Controls immediately if you have any questions.

Table of Contents Product Information... 1 Features...1 MLS-020, MLS-015...1 Pressure Vessel Installation: MLS-020 and MLS-015... 2 Direct Installation into the Wall of the Pressure Vessel...2 Installation with a Weld Collar...3 Installation Using Murphy External Float Chamber...3 Electrical Wiring...4 Replacement Parts... 4 15000531: MLS Float...4 Accessories... 4 15050375: Weld Collar...4 15051098: External Float Chamber...5 15700799: Series 100 External Float Chamber...5 Specifications... 6 MLS Series...6 Approximate Shipping Weights and Dimensions...6

THIS PAGE INTENTIONALLY LEFT BLANK

Product Information Features Clean magnet design virtually eliminates iron filing accumulation onto the magnet Seal-free construction Designed for harsh gas compressor scrubber applications CF8 (304) cast stainless steel body and 304 stainless steel float MLS Series rated for 2000 psi (13.8 MPa) [138 bar] working pressure Electric model only available Improved design provides better dependability with reduced number of moving parts All models screw directly into the scrubber or can be mounted via external float chamber CSA C/US Class l, Div. 1, Grp. B, C & D locations Canadian Registration Number: MLS-020, MLS-015: 0F12013.2 C (all provinces and territories) MLS-020, MLS-015 MLS Series Liquid Level Switches with 2 inch NPT and 1-1/2 inch NPT mounting are float activated to operate an electrical SPDT reed switch for alarm or shutdown of an engine or electric motor. The MLS Series connects directly into the scrubber wall and can be used with a Murphy weld collar (P/N 15050375) or Murphy external float chamber (P/N 15700799). Thread Table - Table 1 Model No MLS-015 MLS-020 Thread A 1-½ inch NPT 2 inch NPT NOTE: Refer to Table 2 for clearances. Section 15 00-02-0730 2015-03-16-1 -

Pressure Vessel Installation: MLS-020 and MLS-015 Direct Installation into the Wall of the Pressure Vessel CAUTION: Determine that the float travel is not obstructed by the coupling in the vessel wall, internal baffles, etc. Refer to tables 1 and 2 for application data. INSTALLATION SHOULD BE ACCOMPLISHED BY QUALIFIED PERSONNEL ONLY. 1. Make certain the float is tightly screwed onto the counter-balance. 2. Before installing the level switch, use of a pipe thread sealant is recommended. Screw the unit directly into the threaded connection in the wall of the pressure vessel. 3. Verify that the electrical connection is positioned at the bottom. NOTE: The word TOP is cast into the top of the body. 4. Make the electrical wiring connections according to appropriate wiring diagrams for the alarm or shutdown system to be used. The electrical connection is ½ inch-14 NPT. 5. Ensure all electrical connections are insulated, and the cover is fully installed before reconnecting electrical power. 6. Verify all pressure connections are tight before pressurizing the system. Float Clearance Reference Tables Pipe Data - Table 2 O.D. Schedule Wall Thickness (inches) Number (inches) 2.5 2.875 40STD 0.203 2.469 3 3.5 40STD 0.216 3.068 3 3.5 80XS 0.3 2.9 4 4.5 40STD 0.237 4.026 4 4.5 80XS 0.337 3.826 Nom. Size (inches) Inside Diameter (inches) Section 15 00-02-0730 2015-03-16-2 -

Installation with a Weld Collar 1. The weld collar, P/N 15050375, must be welded into the wall of the pressure vessel according to code standards and good welding practices. 2. Follow above instructions for installation directly into the wall of the pressure vessel. Weld collar 15050375 is not recommended with a 1 inch float extension. Installation Using Murphy External Float Chamber 1. Install the Murphy float chamber 15051098 or 15700799 on the outside wall of the pressure vessel using 1 NPT piping. Position the 2 inch NPT threaded connection at the height where you want the level switch to operate. The 2 inch NPT threaded connection must be positioned away from the tank wall. NOTE: If using Float Chamber 15051098, best practices recommend a surface mount installation. 2. A tee and bleed valve are typically installed at the bottom of the lower 1 inch pipe riser to allow draining of the float chamber for servicing or replacement. NOTE: A typical installation with blocking and bleed valves is shown at right. 3. Install the MLS-020 in the 2 inch NPT connection of the float chamber. BE SURE float travel is not restricted and that the float is tight onto the counter-balance. 4. To complete the installation and wiring, follow the instructions for mounting directly into wall of the vessel and for wiring. Section 15 00-02-0730 2015-03-16-3 -

Electrical Wiring Switch Rating: 30VDC/VAC @ 75 ma Replacement Parts Order by part number designation. 15000531: MLS Float Stainless Steel Float, MLS Series (not interchangeable with any other Murphy Level Switch Float) Accessories 15050375: Weld Collar Operating pressure: 2000 psi (13.8 MPa) [138 bar]. Operating temperature: 400 F (204 C). Not recommended with 1 inch Float Extension. Section 15 00-02-0730 2015-03-16-4 -

15051098: External Float Chamber Operating pressure: 2000 psi (13.8 MPa) [138 bar] Operating temperature: 400 F (204 C). 15700799: Series 100 External Float Chamber Operating pressure: 2000 psi (13.8 MPa) [138 bar] Operating temperature: 400 F (204 C). Section 15 00-02-0730 2015-03-16-5 -

Specifications MLS Series Process connection: 2 NPT (MLS-020) 1-1/2 NPT (MLS-015) Fluid Density (SG): 0.50 min. (No Extension) 0.65 min (1 Extension) Pressure Rating: 2000 psig (13.8 MPa)[138 bar] Materials: Body: ASTM A351 CF8 (304 SS) Cover: ASTM A351 CF8 (304 SS) Other Wetted Parts: 304 or 316 SS Process Temperature: -20 to 300 F (-29 to 149 C) Electrical: 30VAC/VDC 75mA Form C SPDT Approximate Shipping Weights and Dimensions Weight: MLS-020, 5.5lbs (2.49 kg); MLS-015, 5 lbs (2.27 kg) Dimensions: 14 x 5 x 3.5 in. (356 x 127 x 89 mm) Section 15 00-02-0730 2015-03-16-6 -

THIS PAGE INTENTIONALY LEFT BLANK

\