1 o/c1 BS 7671 does not apply to a equipment of aircraft b photovoltaic systems c marinas d fairgrounds.

Similar documents
PROTECTION AGAINST ELECTRIC SHOCK by John Ware

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

NZECP 14: 1995 ISSN COVER PAGE

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters

Electrical Resistance Resistance (R)

Building Regulations P.4. Socket Outlets P.6. Other Considerations P.10. Training Seminars P.24

chapter8 Testing and commissioning Unit 2 outcome 2

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Electrical installation condition reporting:

A B Brown. This sheet forms part of *Inspection Report Number/*Certificate Number NA/ * EC/ * PIR *Delete as applicable DB

BS 7671:2008+A3:2015 MODEL FORMS

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS RESIDUAL CURRENT DEVICES

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

AS/NZS 3000:2007 Amendment 2

GUIDE TO THE AM2 EXAM

FORMS for the 17th Edition

Electrical Practices for Construction Work

ONLINE VERSION ONLINE VERSION ONLINE VERSION edition. Electrical safety dwellings APPROVED DOCUMENT. The Building Regulations 2000

SELECTION OF FINAL CIRCUIT PROTECTION

By Mark Coles. This article looks at the temporary use of portable generators in floating, earthed and reference-earthing scenarios.

Electrical Contractors Association

6.0 Electrical Installations

A Guide to 17th Edition Testing

GUIDELINES FOR ELECTRICAL WIRING IN RESIDENTIAL BUILDINGS

Electrical Safety Tips. Help us keep you safe

Circuit Electrical Testing

Product and functional description

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

Section 559 luminaires and lighting installations An overview by Geoff Cronshaw

Healthcare interpretation of IEE Guidance Note 7 (Chapter 10) and IEC for

EDS CUSTOMER LV INSTALLATION EARTHING DESIGN

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

INFRARED QUARTZ WALL HEATER

Unified requirements for systems with voltages above 1 kv up to 15 kv

Electrical safety and you

PART P: DOMESTIC ELECTRICAL SAFETY April 2006 Revisions (modified April 2007)

FREQUENTLY ASKED QUESTIONS

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Insulation resistance

Solar Panel Installations

The Electricity Wiring Regulations

ELECTRICAL PRACTICES FOR CONSTRUCTION WORK

How To Understand The Electrical Power Supply Of A Power Supply System

Electrical test equipment for use on low voltage electrical systems

chapter6 Basic electrical circuitry and applications Unit 2 Outcome 3

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

HM-W536 Install Guide

Electrical safety Dwellings

GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

City of Riverside Building & Safety Division Phone: (951)

R.C.C.B. s two-pole LEXIC

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Heading FACT SHEET. Overview.

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Are you aware. Outline

DALI RC BASIC SO. Control unit Operating instructions

Guidance notes for the installation of electrical supply in mobile trailers for breast screening

SURGE PROTECTIVE DEVICES

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Electrical Grounding. Appendix C

The Electricity Wiring Regulations 2007

NEW ZEALAND ELECTRICAL CODE OF PRACTICE REPAIR AND MAINTENANCE OF DOMESTIC ELECTRICAL APPLIANCES BY THE OWNER OF THE APPLIANCE

Electrical safety requirements in DC distribution systems

Guide to the electrical parameter classifications of IEC and IEC safety standards

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Candidate Self-Assessment Checklist

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

Ontario Electrical Safety Code 25 th Edition/ 2012

Guide to the Selection & Use of Residual Current Devices

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

WIRING MATTERS. EARTHING: Your questions answered. Electrical installations outdoors Ongoing accuracy of test instruments PAT testing of equipment

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Residual Current Circuit Breaker

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Criteria for Selecting a Residual-Current Device

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Sizing conductors and selecting protection devices

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

BroadBand PowerShield. User Manual

WORLDWIDE. GW400k SERIES MAINTENANCE MANUAL PROVEN PERIMETER PROTECTION

Regulation IO-6.0: Electrical Safety Regulations

User s Manual Before using the inverter, you need to read and save the safety instructions.

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

TT TOYS TOYS - OWNER S MANUAL. We are delighted that you have decided to purchase this TT Toys Toys children s car.

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Safety & Environmental Protection Services Guidance Note

City of San Diego Residential Photovoltaic Systems Inspection Guidelines

RCD Inspection Log Book

Transcription:

1 Paper 1 Sample Questions - C&G 2382-20 full 17th Edition paper A 1 o/c1 BS 7671 does not apply to a equipment of aircraft b photovoltaic systems c marinas d fairgrounds. 2 o/c1 - Which of the following electrical installations is not covered by BS 7671: a photovoltaic systems. b agricultural and horticultural. c low voltage generating sets. d public electricity distribution. 3 o/c1 BS 7671 applies to a equipmentpn board ships b lightning protection of buildings c lift installations d prefabricated buildings. 4 oc1 BS 7671 requires protection against electric shock to be provided, by basic and fault protection. One method common to both is a the use of RCDs b the use of Class H equipment c preventing current from passing through any person or livestock d the use and implementation of equipotential bonding. 5 o/c2 Which of the following would be defined as a live part? a Earthing conductor b Line conductor c Exposed-conductive-part d PEN conductor 6 o/c 2 - A protective conductor connecting exposed conductive parts of equipment to the main earth terminal is a: a equipotential bonding conductor. b main bonding conductor. c earthing conductor. d circuit protective conductor 7 o/c2 Protection against electric shock under single-fault conditions is defined as a overload protection b fault protection c basic protection d undervoltage protection.

2 Paper 1 8 o/c3 The effectiveness of protective measures should be considered with regard to a external influences b safety services c maintainability d compatibility. 9 o/c 3 - When assessing the frequency and quality of maintenance of an installation the person responsible for the operation and/or maintenance of the installation shall be: a consulted. b informed. c invoiced. d named. 10 Oc3 With reference to the nature of the supply, which one of the following can be determined by calculation, enquiry or measurement? a The maximum demand of the installation b The rating of the circuit protective device c The prospective short-circuit current at the origin of the installation d The csa of the tails 11 oc3 To ensure continuity of supply to one part of the installation in the event of failure of another part, one approach is a for a separate circuit to be installed for each part b to use protective equipotential bonding c to install larger fuses d to install a 100 ma S type RCD. 12 oc3 When making an assessment of the frequency and quality of maintenance, a factor to be considered is that a power factor is monitored b protective measures for safety remain effective c starting currents are at a minimum d unbalanced loads need to be checked more frequently. 13 o/c4 Where the measure of automatic disconnection of supply is employed, fault protection may be provided by a protective earthing only b protective equipotential bonding only c protective earthing and protective equipotential bonding d electrical separation. 14 o/c 4 Which of these is not is not suitable for a SELV system a Engine driven generator

3 Paper 1 b Auto step up transformer c BS 3535 safety transformer d Lead - acid battery 15 10 o/c 4 - Which of the following items does not offer basic protection: a a circuit protective conductor. b a socket outlet. c a lampholder. d equipotential bonding conductors. 16 o/c 4 - A 230V circuit is protected by a 20A Type B circuit-breaker to BS EN 60898. The minimum value of fault current to ensure compliance with maximum disconnection times: a 80A. b 100A. c 125A. d 150A. 17 o/c 4 Max Zs for a TT system with a 300mA RCD 1667 ohms 500 ohms 167 ohms 100 ohms 18 o/c 4 When protecting against burns a metallic part intended to be touched but not hand held shall be limited to a maximum temperature of: a 70 ºC. b 75 ºC. c 80 ºC. d 85 ºC. 19 o/c 4- Correct co-ordination between circuit conductors and an overcurrent protection device is achieved when: a In exceeds the lowest current carrying capacity Iz. b In is less than the design current Ib. c Ib is less than Iz. d Iz is lower than or equal to Ib. 20 o/c4 - Correct co-ordination between conductors and the circuit overcurrent protective device is achieved when: a In is less than Ib. b In does not exceed Iz. c Ib > 1.45 IZ. d Ib exceeds IZ.

4 Paper 1 21 o/c 4 Except for equipment for which an appropriate product standard specifies requirements, a luminaire shall be kept at an adequate distance from combustible materials. Unless otherwise recommended by the manufacturer, a small spotlight or a projector rated at over 100 W and up to 300 W shall be installed at the following minimum distances from combustible materials. a 0.3M b 0.5M. c 0.8M. (422.3.1) d 1.1M 22 o/c4 A 6A BS EN 61009 RCBO with a maximum value of earth fault loop impedance of 1.92 is type a A b B c C d D. 23 Oc4 An undervoltage device has operated and restoring the supply may cause danger. The reclosure of this device should be a automatic when under the supervision of a competent person b manually operated c possible only with the use of a key or tool d automatic with time delay. 24 o/c4 A SELV source can be derived from which one of the following? a Double-wound transformer b Autotransformer c Safety isolating transformer d Step-up transformer 25 o/c4 In locations with increased risks of fire, motors which are automatically or remotely controlled, or which are nolt continuously supervised, shall be protected against excessive temperature by a a protective device that is automatically reset b a protective device with manual reset c electronic monitoring equipment that resets d electronic monitoring equipment that restarts the motor. 26 oc4 A BS 88-6 32 A fuse with U 0 of 230 V has a maximum tabulated Z s for 5 seconds disconnection of a 0.36 ohm b 1.04ohm c 1.44ohm d 1.84ohm

5 Paper 1 27 o/c5 - When cables are placed directly in the ground they should be buried at a depth: a sufficient to avoid damage. b of not less than 1.0 m. c sufficient to allow easy access. d of not less than 1.5m. 28 o/c 5 Which of the following may be used to provide emergency switching for a motor: a a plug and socket. b a luminaire connection device. c a device which latches in the OFF position. d a key switch. 29 o/c 5 - BS 5839 deals with the system design, installation and servicing of: a low power supply sources. b emergency escape lighting. c fire alarms. d generator supply sources. 30 o/c 5 An industrial board supplies 4 x TP motors 2 x TP&N motors 4 x single phase ring circuits 2 x single phase lighting circuits how many live conductors are there. 31 o/c5 A cable concealed in a wall outside the prescribed zones at a depth of less than 50 mm must a not be installed b be enclosed in unearthed conduit c be enclosed in earthed metallic conduit d be protected by a 500 marcd. 32 o/c5 Which of the following is the symbol for a "class P" thermally protected independent lamp ballast permitted for mounting on a flammable surface? 33 o/c5- A permanent warning notice must be fixed at or near the point of connection of every earthing conductor to an earth electrode bearing the words:

6 Paper 1 a Safety Electrical Connection Do Not Remove. b Earth Bonding Danger. c Safety Electrical Earth Do Not Remove. d Electrical Connection Danger. 34 o/c5 - Cables and equipment in circuits feeding motors shall be suitable for a current of at least: a the full-load current rating of the motor. b half the full-load current rating of the motor. c twice the full-load current rating of the motor. d four times the full-load current rating of the motor. 35 o/c5 - Accessible street furniture enclosures containing live parts shall only be opened using a: a key or tool. b ladder. c insulated screwdriver. d harness. 36 o/c5 An RCD that is installed for protection against the risk of fire where combustible materials are stored shall be a installed at the farthest point of the circuit b installed atthe origin of the circuit c arranged to switch line conductors d rated at 500mA. 37 o/c5 A firefighter's switch shall be provided in the low voltage circuit supplying exterior electrical installations and interior discharge lighting operating at a a voltage exceeding low voltage b low voltage c voltage band II d medium voltage. 38 Where a 3-core cable, with cores coloured brown, black and grey, : is used as a switch wire for two-way or intermediate control, the terminations of the conductors shall be identified using a red, blue and yellow tape b black tape only on each core c brown tape on the black and grey cores d self-colour tape only. 39 o/c5 A radial final circuit feeding socket-outlets supplying several items of data processing equipment has a total protective conductor current in normal service of 18 ma. This circuit must have a high integrity protective conductor

7 Paper 1 a of cross-sectional area less than 1 mm 2 b connected as a ring c controlled by an isolator d enclosed in insulated conduit only. 40 oc5 When selecting equipment for an installation, the person who makes the final decision over its safety would be the a representative of a regional supply company b representative of a national inspection body c designer or other person responsible d inspector and tester. 41 oc 5 The minimum information contained on a periodjc inspection and testing notice would be the a date of inspection and inspector's name b date of next inspection and client's name c date of last inspection and date of next inspection d company's address and date of next inspection. 42 o/c6 612.3.2 - The minimum insulation resistance between conductors for an extra-low voltage circuit is: a 0.25 MΩ. b 0.5 MΩ. c 1.0 MΩ. d 2.0 MΩ. 43 o/c 6 - With regard to determining the frequency of periodic inspection and testing of an installation, which of the following does not need to be considered: a results of previous reports. b the installation use. c the frequency of maintenance. d the quality of the test instruments. 44 o/c 6 - Which of the following statements is incorrect: a periodic inspection is carried out to check for heat arising from an installation defect. b a schedule of inspections and test results must accompany a periodic inspection report. c periodic inspection and testing must be carried out by a fully qualified electrician. d where possible, results from previous inspection and testing must be taken into. 45 o/c6 - BS 7671 recommends that continuity testers shall be capable of having a no-load voltage between: a 4V and 24V d.c. or a.c. b 4V and 24V d.c.

8 Paper 1 c 24V and 250V a.c. d 24V and 250V d.c. or a.c. Section 6 46 13 Which of the following is the designated symbol for a high pressure sodium lamp with an internal starting device? 47 oc6 When carrying out an inspection of a new installation, it is not necessary to verify the a total earth fault loop impedance for each circuit b connection of conductors c methods of protection against electric shock d presence of diagrams, instructions and similar information. 48 o/c7 - In a location containing a bath or shower supplementary bonding may be omitted, amongst other conditions, where: : a all final circuits have additional RCD protection. b main equipotential bonding is not required. c automatic disconnection of most final circuits of the location comply with Regulation 411.3.2. d luminaires are situated outside the Zones. 49 o/c7 For an agricultural location, in order to provide automatic disconnection of supply in circuits other than socket-outlet circuits, a disconnection device shall be installed having a maximum rated residual operating current of a 30mA b 100mA c 300mA d 500mA. 50 o/c 7 - On caravan sites, overhead conductors in areas subject to vehicle movement shall be placed at a minimum height above ground of: a 2.5 m. b 3.5 m. c 6.0m. d 8.0m. 51 o/c 7 - A PV convertor shall have a switch-disconnector provided on: a the a.c. side. b the d.c. side. c the a.c. and d.c. sides. d neither the a.c. nor the d.c. sides.

9 Paper 1 52 o/c 7 - Which of the following systems shall not be used to supply equipment used in repair and alteration work on construction sites: a TN-S. b TN-C-S. c TT. d separate earth and neutral supplies. 53 o/c 7 - In a sauna which one of the zones has no special requirements concerning the heat resistance of the equipment: a 1. b 2. c 3. d 4. 54 o/c 7 - Electrical equipment installed outside in caravan parks shall be protected against mechanical stresses to a minimum of: a AG3. b AD4. c AE2. d AD3. 55 o/c7 The maximum length of a flexible cord or cable for a caravan connection is a 1.8m b 6m c 10m d 25m. 56 oc7 In a swimming pool or other basin, the metallic covering or sheath of a wiring system in zones 0,1 or 2 shall a not be used b not be earthed c be connected to the supplementary bonding d have reinforced insulation. 57 oc7 Electric dodgems shall only be operated at voltages not exceeding a 120Va.c.or50Vd.c. b 50Va.c.or120Vd.c. c 110 V a.c. reduced low voltage d 1000Va.c.oM500Vd.c. 58 7 o/c 8 app7 - In the new colouring system the neutral in a three-phase a.c. system will be: a brown b red

10 Paper 1 c black d blue 59 oc8 I 2 can be greater than 1.45 l z when the overcurrent device a is providing overload protection -* b is a circuit-breaker c is rated at over 100 A d is providing fault current protection only. 60 20 A final circuit is the wiring between A. supply company's fuse and the energy meter B. main switch and the distribution board C. distribution board and current using equipment D. supply company's fuse and the remotest outlet point Answers below

11 Paper 1 Sample Questions - C&G 2382 17th Edition 1 o/c1 BS 7671 does not apply to a equipment of aircraft b photovoltaic systems c marinas d fairgrounds. Answer a See Part 1: Scope, Regulation 110.2. 2 o/c1 - Which of the following electrical installations is not covered by BS 7671: a photovoltaic systems. b agricultural and horticultural. c low voltage generating sets. d public electricity distribution. 3 o/c1 BS 7671 applies to a equipmentpn board ships b lightning protection of buildings c lift installations d prefabricated buildings. Answer dsee Part 1, Chapter 11, Scope. Option d, prefabricated buildings, is listed in Regulation 110.1, 4 oc1 BS 7671 requires protection against electric shock to be provided, by basic and fault protection. One method common to both is a the use of RCDs b the use of Class H equipment c preventing current from passing through any person or livestock d the use and implementation of equipotential bonding. Chap 13 131.2.2 5 o/c2 Which of the following would be defined as a live part? a Earthing conductor b Line conductor c Exposed-conductive-part d PEN conductor Answer b See Part 2: Definitions. 6 o/c 2 - A protective conductor connecting exposed conductive parts of equipment to the main earth terminal is a: a equipotential bonding conductor. b main bonding conductor. c earthing conductor. d circuit protective conductor

12 Paper 1 7 o/c2 Protection against electric shock under single-fault conditions is defined as a overload protection b fault protection c basic protection d undervoltage protection. Answer b See Part 2: Definitions. 8 o/c3 The effectiveness of protective measures should be considered with regard to a external influences b safety services c maintainability d compatibility. Answer c See Part 3: Assessment of general characteristics, Regulation 341.1. 9 o/c 3 - When assessing the frequency and quality of maintenance of an installation the person responsible for the operation and/or maintenance of the installation shall be: a consulted. b informed. c invoiced. d named. 10 Oc3 With reference to the nature of the supply, which one of the following can be determined by calculation, enquiry or measurement? a The maximum demand of the installation b The rating of the circuit protective device c The prospective short-circuit current at the origin of the installation d The csa of the tails reg 313.1 11 oc3 To ensure continuity of supply to one part of the installation in the event of failure of another part, one approach is a for a separate circuit to be installed for each part b to use protective equipotential bonding c to install larger fuses d to install a 100 ma S type RCD. 314.2 12 oc3 When making an assessment of the frequency and quality of maintenance, a factor to be considered is that a power factor is monitored b protective measures for safety remain effective c starting currents are at a minimum

d 13 Paper 1 unbalanced loads need to be checked more frequently. 13 o/c4 Where the measure of automatic disconnection of supply is employed, fault protection may be provided by a protective earthing only b protective equipotential bonding only c protective earthing and protective equipotential bonding d electrical separation. Answer d See Part 4: Protection for safety, Regulation 411.1. 14 o/c 4 Which of these is not is not suitable for a SELV system a Engine driven generator b Auto step up transformer c BS 3535 safety transformer d Lead - acid battery 15 10 o/c 4 - Which of the following items does not offer basic protection: a a circuit protective conductor. b a socket outlet. c a lampholder. d equipotential bonding conductors. 16 o/c 4 - A 230V circuit is protected by a 20A Type B circuit-breaker to BS EN 60898. The minimum value of fault current to ensure compliance with maximum disconnection times: a 80A. b 100A. c 125A. d 150A. 17 o/c 4 Max Zs for a TT system with a 300mA RCD 1667 ohms 500 ohms 167 ohms 100 ohms 18 o/c 4 When protecting against burns a metallic part intended to be touched but not hand held shall be limited to a maximum temperature of: a 70 ºC. b 75 ºC. c 80 ºC. d 85 ºC. 19 o/c 4- Correct co-ordination between circuit conductors and an overcurrent protection device is achieved when:

14 Paper 1 a In exceeds the lowest current carrying capacity Iz. b In is less than the design current Ib. c Ib is less than Iz. d Iz is lower than or equal to Ib. 20 o/c4 - Correct co-ordination between conductors and the circuit overcurrent protective device is achieved when: a In is less than Ib. b In does not exceed Iz. c Ib > 1.45 IZ. d Ib exceeds IZ. 21 o/c 4 Except for equipment for which an appropriate product standard specifies requirements, a luminaire shall be kept at an adequate distance from combustible materials. Unless otherwise recommended by the manufacturer, a small spotlight or a projector rated at over 100 W and up to 300 W shall be installed at the following minimum distances from combustible materials. a 0.3M b 0.5M. c 0.8M. (422.3.1) d 1.1M 22 o/c4 A 6A BS EN 61009 RCBO with a maximum value of earth fault loop impedance of 1.92 is type a A b B c C d D. Answer d See Part 4: Protection for safety, Regulation 411.4.7, Table 41.3. 23 Oc4 An undervoltage device has operated and restoring the supply may cause danger. The reclosure of this device should be a automatic when under the supervision of a competent person b manually operated c possible only with the use of a key or tool d automatic with time delay. Answer bsee Part 4: Protection for safety, Regulation 445.1.5. 24 o/c4 A SELV source can be derived from which one of the following? a Double-wound transformer b Autotransformer c Safety isolating transformer d Step-up transformer 414.3

15 Paper 1 25 o/c4 In locations with increased risks of fire, motors which are automatically or remotely controlled, or which are nolt continuously supervised, shall be protected against excessive temperature by a a protective device that is automatically reset b a protective device with manual reset c electronic monitoring equipment that resets d electronic monitoring equipment that restarts the motor. 422.3.7 26 oc4 A BS 88-6 32 A fuse with U 0 of 230 V has a maximum tabulated Z s for 5 seconds disconnection of a 0.36 ohm b 1.04ohm c 1.44ohm d 1.84Qohm table 41.4 27 o/c5 - When cables are placed directly in the ground they should be buried at a depth: a sufficient to avoid damage. b of not less than 1.0 m. c sufficient to allow easy access. d of not less than 1.5m. 28 o/c 5 Which of the following may be used to provide emergency switching for a motor: a a plug and socket. b a luminaire connection device. c a device which latches in the OFF position. d a key switch. 29 o/c 5 - BS 5839 deals with the system design, installation and servicing of: a low power supply sources. b emergency escape lighting. c fire alarms. d generator supply sources. 30 o/c 5 An industrial board supplies 4 x TP motors 2 x TP&N motors 4 x single phase ring circuits 2 x single phase lighting circuits

16 Paper 1 how many live conductors are there. (40) 31 o/c5 A cable concealed in a wall outside the prescribed zones at a depth of less than 50 mm must a not be installed b be enclosed in unearthed conduit c be enclosed in earthed metallic conduit d be protected by a 500 marcd. Answer c See Part5: Selection and erection of equipment, Regulation 522.6.6. 32 o/c5 Which of the following is the symbol for a "class P" thermally protected independent lamp ballast permitted for mounting on a flammable surface? Answer c See Part 5: Selection and erection of equipment, Regulation 559.7 and Table 55.2. 33 o/c5- A permanent warning notice must be fixed at or near the point of connection of every earthing conductor to an earth electrode bearing the words: a Safety Electrical Connection Do Not Remove. b Earth Bonding Danger. c Safety Electrical Earth Do Not Remove. d Electrical Connection Danger. 34 o/c5 - Cables and equipment in circuits feeding motors shall be suitable for a current of at least: a the full-load current rating of the motor. b half the full-load current rating of the motor. c twice the full-load current rating of the motor. d four times the full-load current rating of the motor. 35 o/c5 - Accessible street furniture enclosures containing live parts shall only be opened using a: a key or tool. b ladder. c insulated screwdriver. d harness. 36 o/c5 An RCD that is installed for protection against the risk of fire where combustible materials are stored shall be a installed at the farthest point of the circuit b installed atthe origin of the circuit

17 Paper 1 c arranged to switch line conductors d rated at 500mA. Answer b See PartS: Selection and erection of equipment, Regulation 532.1. Where a 30 ma RCD is installed upstream of a residual current monitor (RCM), the rating of the RCM shall not exceed Answer b See Part 5: Selection and erection of equipment, Regulation 559.4 and Table 55.2. 37 o/c5 A firefighter's switch shall be provided in the low voltage circuit supplying exterior electrical installations and interior discharge lighting operating at a a voltage exceeding low voltage b low voltage c voltage band II d medium voltage. 537.6.1 38 Where a 3-core cable, with cores coloured brown, black and grey, : is used as a switch wire for two-way or intermediate control, the terminations of the conductors shall be identified using a red, blue and yellow tape b black tape only on each core c brown tape on the black and grey cores d self-colour tape only. 514.4.4 39 o/c5 A radial final circuit feeding socket-outlets supplying several items of data processing equipment has a total protective conductor current in normal service of 18 ma. This circuit must have a high integrity protective conductor a of cross-sectional area less than 1 mm 2 b connected as a ring c controlled by an isolator d enclosed in insulated conduit only. 543.7.2.1 40 oc5 When selecting equipment for an installation, the person who makes the final decision over its safety would be the a representative of a regional supply company b representative of a national inspection body c designer or other person responsible d inspector and tester. Sec511 511.2

18 Paper 1 41 oc 5 The minimum information contained on a periodjc inspection and testing notice would be the a date of inspection and inspector's name b date of next inspection and client's name c date of last inspection and date of next inspection d company's address and date of next inspection. 514.12.1 42 o/c6 612.3.2 - The minimum insulation resistance between conductors for an extra-low voltage circuit is: a 0.25 MΩ. b 0.5 MΩ. c 1.0 MΩ. d 2.0 MΩ. 43 o/c 6 - With regard to determining the frequency of periodic inspection and testing of an installation, which of the following does not need to be considered: a results of previous reports. b the installation use. c the frequency of maintenance. d the quality of the test instruments. 44 o/c 6 - Which of the following statements is incorrect: a periodic inspection is carried out to check for heat arising from an installation defect. b a schedule of inspections and test results must accompany a periodic inspection report. c periodic inspection and testing must be carried out by a fully qualified electrician. d where possible, results from previous inspection and testing must be taken into. 45 o/c6 - BS 7671 recommends that continuity testers shall be capable of having a no-load voltage between: a 4V and 24V d.c. or a.c. b 4V and 24V d.c. c 24V and 250V a.c. d 24V and 250V d.c. or a.c. Section 6 46 13 Which of the following is the designated symbol for a high pressure sodium lamp with an internal starting device?

19 Paper 1 47 oc6 When carrying out an inspection of a new installation, it is not necessary to verify the a total earth fault loop impedance for each circuit b connection of conductors c methods of protection against electric shock d presence of diagrams, instructions and similar information. 611.3 48 o/c7 - In a location containing a bath or shower supplementary bonding may be omitted, amongst other conditions, where: : a all final circuits have additional RCD protection. b main equipotential bonding is not required. c automatic disconnection of most final circuits of the location comply with Regulation 411.3.2. d luminaires are situated outside the Zones. 49 o/c7 For an agricultural location, in order to provide automatic disconnection of supply in circuits other than socket-outlet circuits, a disconnection device shall be installed having a maximum rated residual operating current of a 30mA b 100mA c 300mA d 500mA. Answer csee Part 7: Special installations or locations, Regulation 705.411.1. 50 o/c 7 - On caravan sites, overhead conductors in areas subject to vehicle movement shall be placed at a minimum height above ground of: a 2.5 m. b 3.5 m. c 6.0m. d 8.0m. 51 o/c 7 - A PV convertor shall have a switch-disconnector provided on: a the a.c. side. b the d.c. side. c the a.c. and d.c. sides. d neither the a.c. nor the d.c. sides. 52 o/c 7 - Which of the following systems shall not be used to supply equipment used in repair and alteration work on construction sites: a TN-S. b TN-C-S. c TT. d separate earth and neutral supplies.

20 Paper 1 53 o/c 7 - In a sauna which one of the zones has no special requirements concerning the heat resistance of the equipment: a 1. b 2. c 3. d 4. 54 o/c 7 - Electrical equipment installed outside in caravan parks shall be protected against mechanical stresses to a minimum of: a AG3. b AD4. c AE2. d AD3. 55 o/c7 The maximum length of a flexible cord or cable for a caravan connection is a 1.8m b 6m c 10m d 25m. Answer d See Part 7: Special installations or locations, Section 708, Fig 708, or Regulation 721.55.2.6. 56 oc7 In a swimming pool or other basin, the metallic covering or sheath of a wiring system in zones 0,1 or 2 shall a not be used b not be earthed c be connected to the supplementary bonding d have reinforced insulation. 702.52 702.522.21 57 oc7 Electric dodgems shall only be operated at voltages not exceeding a 120Va.c.or50Vd.c. b 50Va.c.or120Vd.c. c 110 V a.c. reduced low voltage d 1000Va.c.oM500Vd.c. 740.55.9 58 7 o/c 8 app7 - In the new colouring system the neutral in a three-phase a.c. system will be: a brown b red c black d blue

21 Paper 1 59 oc8 I 2 can be greater than 1.45 l z when the overcurrent device a is providing overload protection -* b is a circuit-breaker c is rated at over 100 A d is providing fault current protection only. App4 sec 3 (434.5.2) 60 20 A final circuit is the wiring between E. supply company's fuse and the energy meter F. main switch and the distribution board G. distribution board and current using equipment H. supply company's fuse and the remotest outlet point App15