NanoRacks Internal Platforms 1A/2A and NanoLab Modules Interface Control Document

Similar documents
HOW TO BUILD A NANORACKS PAYLOAD: NANOLABS

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

FUSION R400 RAID USB 3.0

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Mounting Printed Circut Boards (PCB) Toll Free: (US & Canada) Fax: info@protocasedesigner.com

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

SMART Board 8070i-SMP and 8070i

User Manual. EtherUSB

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

2.5 HDD Enclosure Kit

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

=============================== WARNING

SmartCard On-Board Reader (# 8105) SmartCard Desktop Reader (# 8108) SmartCards, Pack of 10 (# 8112) Starter Interrupter Kit (# 8116)

MANUAL FOR RX700 LR and NR

SMART Board 8055i and 8055i-SMP

Installation Instructions

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

USB Port Extender Kit

DU-H3ETX. 3-port USB Hub with 1 NWAY Ethernet / Fast Ethernet Port. User s Guide

MCR1900 Media Converter 19-Slot Chassis

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

DVI DA2 and DVI DA 4 User Guide

MDI/MDIX) FEP-32008T-3

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

ENGINEERING COMMITTEE

TF KEYBOARDS. inputs whose state can be displayed via software. They can be used immediately with the TE electromechanical keyboard [see accessories].

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Quest- 1 Satellite Functional Description

ATA TO IDE INTERFACE PC CARD DRIVES

Gigabit Desktop. manual Models & Model shown: INT / UM

PCI Express USB 2.0 Adapter Card

Belkin High Speed Cable Modem with USB and Ethernet. User Manual

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

TX OPEN RS232/485 module

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

Removable 2.5 SATA HDD Backup System

GEU Port Gigabit Switch

Tablet Management Rack 16

User Manual. EtherUSB

Five9NS R2100RS Rack Mount Server. Installation Manual

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

Research RF Sputtering Packages

8-Port PoE Network Switch

Quanser NI-ELVIS Trainer (QNET) Series: QNET HVAC. Heating, Ventilation, and Air Conditioning (HVAC) User Manual. User Manual

UniStream CPU-for-Panel

Mini USB and USB 2.0-IP67 Connector System

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

PCIe XMC x8 Lane Adapter

Serial ATA Hard Drive Enclosure

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

2.5" SATA HDD Enclosure

Infinity C Reference Guide

Concierge. Outdoor panels

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

UniOP epad33 and epad33t

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

PCS300 Universal IP Reporting Module V1.0

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

2100 POS System User Guide

DC Electronic Loads 8500 series

Serial ATA Hard Drive Docking Station

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

4 Independent Port PCI Express SuperSpeed USB 3.0 Card

A-307. Mobile Data Terminal. Android OS Platform Datasheet

3500/22M Transient Data Interface

IntesisBox KNX LG Air Conditioning

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by

Ultra Thin Client TC-401 TC-402. Users s Guide

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

XPanel V2. Remote Control Panel. User Manual. XILICA Audio Design

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

User Guide TL-SG1016/ TL-SG /24-port Gigabit Ethernet Switch

2 Bay USB 3.0 RAID 3.5in HDD Enclosure

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

HP UPS R1500 Generation 3

USB-RS232 Converter USB-RS422/485 Converter. User's Manual

Cisco Model DPC3000 DOCSIS 3.0 Cable Modem

Multi-Profile CMOS Infrared Network Camera

Acano solution. Acano Solution Installation Guide. Acano. January B

Operations Planning for the International Space Station

2 Ohm Nominal Coaxial Speaker OWNER S MANUAL

TUP500. Interface Type. Quick Setup Guide. Thank you for choosing Star Micronics as your provider for printing solutions. Unpacking the Unit

AU-110 racking guide NBXPN: 023

PCI Superspeed USB 3.0 Cards

TrueAlarm Fire Alarm Systems

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

AXIS T81B22 DC 30W Midspan

Transcription:

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 1 of 14 and NanoLab Modules Interface Control Document NanoRacks, LLC 555 Forge River Road, Suite 120 Webster, TX 77598 www.nanoracks.com

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 2 of 14 Issue Date Author Approved Details.1 2010 Various Baseline.2 4/21/2013 ACP.21 6/18/2013 ACP Further details added.3 8/12/2013 ACP.31 6/05/2014 MLR Further details added.4 2/13/2015 MLR, MMM MDJ Major Revision

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 3 of 14 Acronyms BOM EMI EXPRESS ICD ISS JEM NLT NR PDR PI SDP SDT STELLA USB Bill of Materials Electromagnetic Interference EXpedite the PRocessing of Experiments to Space Station Interface Control Document International Space Station Japanese Experiment Module No Later Than NanoRacks Preliminary Design Review Principal Investigator Safety Data Package Safety Data Template Software Toolkit for Ethernet Lab-Like Architecture Universal Serial Bus

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 4 of 14 Table of Contents 1 Introduction... 5 1.1 Document Purpose... 5 1.2 Scope... 5 2 Timeline... 5 3 The NanoRacks Platforms... 5 3.1 Overview... 5 3.2 Electrical Properties... 6 3.3 USB Spacing and Orientation... 6 4 The NanoLab Standard... 8 4.1 General Requirements... 8 4.2 NanoLab Modules Dimensions... 8 4.3 NanoLab Mass Properties... 9 4.4 Dimensions for USB Connectors... 9 4.5 Material Requirements... 10 4.6 Liquid Containment Requirements... 10 4.7 Grounding and Bonding Requirements... 11 4.8 Vent Requirements... 11 4.9 Motor Requirements... 11 5 Operations... 11 5.1 Data Handling... 11 6 Testing... 12 6.1 Sharp Edge Test... 12 6.2 Additional Testing Requirements... 12

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 5 of 14 1 Introduction 1.1 Document Purpose This Interface Control Document (ICD) defines the interface requirements between the NanoRacks Platforms (Mark 1A and 2A) and NanoLabs for developers utilizing the NanoRacks Internal Platform services. 1.2 Scope This ICD provides the minimum requirements for compatibility with NanoRacks Platforms 1A and 2A and the International Space Station flight safety program when using NanoRacks Internal Platform services. NanoRacks verifies compliance on behalf of Principal Investigators (PI) based on incremental data requests. 2 Timeline The following timeline of launch-minus dates are provided as template example when using the NanoRacks Internal Platform services. Tailored agreements can be discussed as part of contract negotiations. Launch-minus dates Activity L-8 months to NLT L-6.5 months Contract signing, experiment name and general payload information NLT L-6 months Submit initial manifest request NLT L-6 months Detailed information for Safety and Ops L-5.5 months Phase 0/I/II SDP L-5.5 to L-4 months Complete hardware testing L-5.5 to NLT 3.5 months Submit procedures inputs and payload requirements NLT L-3.5 months Phase III SDP submit/ Fit Check and Functional Test L-2 months to L-2.5 weeks Phase III Safety Review Close Out and Final Approval L-45 days to NLT L-32 hours Turn over to NR for final testing and prep L-30 days to NLT L-24 hours Turn over to NASA 3 The NanoRacks Platforms 3.1 Overview The NanoRacks Platform interfaces between individual NanoLab Modules and the ISS, providing mechanical mounting points and electrical connections for power, data, and communication

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 6 of 14 capabilities. Each platform is installed in its own EXPRESS rack locker located in the Japanese Experiment Module (JEM) of the ISS as shown in Figure 1. As of August 2013, two identical NanoRacks Platforms have been installed and are operational on ISS. Figure 1: NanoRacks Platform Installation to the ExPRESS Rack Locker on ISS 3.2 Electrical Properties Power is provided to each NanoLab through at least one USB port. The maximum power the Platform provides per a USB port is 2 Watts at 5 VDC. Additional power is available through the usage of multiple USB ports. Please discuss the usage of multiple USB ports with NanoRacks personnel. For more information regarding USB ports, please refer to Sections 3.3 and 4.4. 3.3 USB Spacing and Orientation Each NanoRacks Platform includes a total of 16 USB type B male connectors (8 on each side). The connections are oriented as shown in Figure 2 and Figure 3, with the flat edge of the USB connector facing towards the front panel of the NanoRacks Platform. USB spacing dimensions are included in Figure 2. For more information about USB orientation and dimensions, refer to Section 4.4.

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 7 of 14 Figure 2: Platform 1A and 2A side-view with the front panel to the right. The rear fans are not shown. Figure 3: Platform 1A and 2A side-view with the front panel to the left and the rear fans to the right.

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 8 of 14 4 The NanoLab Standard The NanoRacks Platform is designed to support NanoLab modules. NanoLab module sizes can range from a 1U (shown in Figure 4) to a 4 by 2 by 1.5U. This portion of the ICD defines the interface requirements to ensure NanoLab compatibility with the Platforms. 4.1 General Requirements 1) NanoLab modules shall not have any objects protruding from the external module walls. USB connections will be on the inside of the NanoLab and flush with the outer surface of the module. Modules which require a different setup require prior approval from NanoRacks. 2) Threadlocker gels shall not be used on threaded joints on the outer walls of the NanoLab. 3) NanoLabs shall not contain pyrotechnics. 4) Flight verification is based on several data requests from NanoRacks to the PI. PIs must submit the NanoRacks Safety Data Template (SDT), receive Safety Data Package (SDP) approval, and pass a fit check and functional test. Additional data and requirements may apply. Payload handling constraints and requirements may apply depending on PI needs. Schedules for these data requests are based on launch delivery deadlines. 5) Delivery times to NanoRacks are dependent on the payload requirements and can range from L-9 weeks to L-36 hours. Please discuss delivery times with NanoRacks personnel. 6) NanoLab modules may experience an unexpected power loss or multiple power cycles as a result of normal operations aboard the ISS. PIs may consider a recovery mode for their NanoLabs to recover and return the payload to normal operations. 4.2 NanoLab Module Dimensions Dimensional property guidelines for the NanoLabs using the NanoRacks Platforms are summarized in Table 1. An example of a 1U NanoLab is shown in Figure 4. Payloads that require different dimensions require approval by NanoRacks. Form Factor Outer Dimensions of NanoLab 1U 100mm x 100mm x 100mm 1.5U 100mm x 100mm x 152.4mm 2U 100mm x 100mm x 203.2mm 3U 100mm x 100mm x 304.8mm 4U 100mm x 100mm x 406.4mm Table 1: Form Factors for NanoLab Modules

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 9 of 14 Figure 4: 1U NanoLab Module 4.3 NanoLab Mass Properties The mass properties of a NanoLab module shall follow the specifications outlined in Table 2. Form Factor Maximum Mass (g) 1U 1000 2U 2000 3U 3000 4U 4000 Table 2: NanoLab Maximum Mass Properties 4.4 Dimensions for the USB Connectors NanoLabs that require power and data will interface with the NanoRacks Platforms through at least one Type B female USB connector. Proper positioning of the USB port is identified in Figure 6 and Table 3. A mechanical drawing of the USB type B female connector that is required for Platform compatibility is included in Appendix A. USB ports shall be designed to minimize impact on other NanoLab modules. All USB placements shall be approved during the Preliminary Design Review (PDR).

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 10 of 14 Figure 6: NanoLab USB connector dimensions Side A B C D Dimension 33.55 mm 95.37 mm 66.45 mm 14.63 mm Table 3: Dimensions for Figure 5 4.5 Material Requirements The NanoLab housing and internal components shall comply with NASA guidelines for hazardous materials. PIs who choose to manufacture their own NanoLab housing are required to seek material and color approval from NanoRacks personnel. NanoLab developers shall submit a Bill of Materials (BOM) to NanoRacks for assessment. 4.6 Liquid Containment Requirements Multiple levels of containment and additional testing may be required depending on the toxicity and the biohazard level of any liquid. Please speak to NanoRacks personnel for more information concerning research involving fluids of any kind.

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 11 of 14 4.7 Grounding and Bonding Requirements Grounding and bonding is required for all powered modules. PIs using aluminum NanoLabs shall strip all faying surfaces to ensure that all panels and screws make contact. A single point ground shall be implemented from the NanoLab to the USB connector shell. The resistance of the grounding/ bounding shall measure less than 0.1 Ohms. For more information, please contact NanoRacks personnel. 4.8 Vent Requirements The usage of vents on a NanoLab is permitted. Please speak to NanoRacks personnel for more information and approval. 4.9 Motor Requirements The usage of motors within a NanoLab is permitted, but may require additional testing. Please speak to NanoRacks personnel for more information. 5 Operations Operations for a NanoLab are defined by the payload s timespan on-board the ISS. Crew interaction with a NanoLab module is limited to installation and removal from the Platforms. Additional crew time needs to be discussed and negotiated with NanoRacks personnel as early as possible. 5.1 Data Handling STELLA allows NanoRacks ground control to remotely operate the DOS command terminal on an on-orbit Windows XP embedded computer. STELLA also allows for the transfer of files between the NanoLab, the NanoRacks platform, and a NanoRacks ground computer. The file rates for download and upload between ground control and the on-orbit computer are: i. A download rate of 3 Megabits per second. ii. An uplink rate of 50 bytes per second. A 60 KB file is considered practical for uplink. While uploading files is possible, uplink capability and bandwidth are limited. 1) Communication with NanoLabs is done through a DOS command terminal that is controlled through an on-orbit Windows XP embedded computer within the NanoRacks Platform. 2) NanoLabs that require data handling must be recognized as a USB mass storage device by the Platform computer.

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 12 of 14 6 Testing 6.1 Sharp Edge Test NanoLab modules shall undergo a cotton glove test to ensure that no protruding or sharp edges exist that could potentially snag the glove as it passes over all of the NanoLab surfaces, including the USB connector and its fasteners. 6.2 Additional Testing Requirements Additional testing may be required by NASA depending on the nature of the payload. Examples of additional testing requirements may be found in Appendix B.

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 13 of 14 Appendices

Classification: Public Domain Date: 2014-02-13 Revision: 0.4 Page 14 of 14 Appendix A USB Series B Female Receptacle Interface for NanoLab Appendix B The following is a list of potential testing requirements that may be required depending on the design of the NanoLab. Additional requirements may include, but are not limited to: a) Electromagnetic Interference (EMI) b) Offgassing c) Vibration Testing d) Express Payload Frequency Compatibility e) Payload-Generated Acoustic Noise f) Usage of Batteries g) External Surface Touch Temperature