NEEL Phase Change in Chromium At the Néel Temperature

Similar documents
The Fundamentals of Thermoelectrics

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

Errors Due to Shared Leadwires in Parallel Strain Gage Circuits

Basic RTD Measurements. Basics of Resistance Temperature Detectors

Measuring Temperature withthermistors a Tutorial David Potter

HOW ACCURATE ARE THOSE THERMOCOUPLES?

CALIBRATION OF A THERMISTOR THERMOMETER (version = fall 2001)

Characteristic curves of a solar cell

APPLICATION NOTES DEFINITIONS NTC Thermistor 101

The Electrical Properties of Materials: Resistivity

Resistance, Ohm s Law, and the Temperature of a Light Bulb Filament

Measuring Silicon and Germanium Band Gaps using Diode Thermometers

THE STRAIN GAGE PRESSURE TRANSDUCER

IC Temperature Sensor Provides Thermocouple Cold-Junction Compensation

IDEAL AND NON-IDEAL GASES

Physical Properties of a Pure Substance, Water

Experiment 5. Strain Gage Measurements

CHAPTER 6 THERMAL DESIGN CONSIDERATIONS. page. Introduction 6-2. Thermal resistance 6-2. Junction temperature 6-2. Factors affecting R th(j-a) 6-2

Unit 7: Electrical devices LO2: Understand electrical sensors and actuators Sensors temperature the thermistor

Experiment #4, Ohmic Heat

Environmental Monitoring with Sensors: Hands-on Exercise

Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement

Parallel Circuits Charles Lang

5. Measurement of a magnetic field

Conversion of Thermocouple Voltage to Temperature

1. The Determination of Boiling Point

KINETIC THEORY AND THERMODYNAMICS

Time allowed: 1 hour 45 minutes

Evaluation copy. Build a Temperature Sensor. Project PROJECT DESIGN REQUIREMENTS

Objectives 200 CHAPTER 4 RESISTANCE

The Do s and Don ts of Pressure Transducers

Experiment 6 ~ Joule Heating of a Resistor

Experiment #3, Ohm s Law

Vaporization of Liquid Nitrogen

How to measure absolute pressure using piezoresistive sensing elements

Resistor Theory and Technology

Using NTC Temperature Sensors Integrated into Power Modules

LM134-LM234 LM334 THREE TERMINAL ADJUSTABLE CURRENT SOURCES. OPERATES from 1V to 40V

Physical Chemistry Laboratory I CHEM 445 Experiment 6 Vapor Pressure of a Pure Liquid (Revised, 01/09/06)

PC BASED PID TEMPERATURE CONTROLLER

APPLICATION NOTES OF SIGNAL ISOLATORS

SMT POWER THERMISTORS

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

Thermometer Calibration Guide

Galvanic Cells and the Nernst Equation

Magnetic susceptibility. Basic principles and features on the PPMS.

Soldering. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Experiment 4: Sensor Bridge Circuits (tbc 1/11/2007, revised 2/20/2007, 2/28/2007) I. Introduction. From Voltage Dividers to Wheatstone Bridges

Electrochemistry Revised 04/29/15

Figure 1. A voltaic cell Cu,Cu 2+ Ag +, Ag. gas is, by convention, assigned a reduction potential of 0.00 V.

Experiment 9 Electrochemistry I Galvanic Cell

Oxidation States of Copper Two forms of copper oxide are found in nature, copper(i) oxide and copper(ii) oxide.

EXPERIMENT 7 OHM S LAW, RESISTORS IN SERIES AND PARALLEL

Chapter 7 Direct-Current Circuits

ADC-20/ADC-24 Terminal Board. User Guide DO117-5

Thermistor Basics. Application Note AN-TC11 Rev. A. May, 2013 Page 1 WHAT IS A THERMISTOR?

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

جامعة البلقاء التطبيقية

Electricity. Confirming Coulomb s law. LD Physics Leaflets P Wie. Electrostatics Coulomb s law

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

(Issued 1 Dec. 1965) CRD-C METHOD OF TEST FOR THERMAL CONDUCTIVITY OF LIGHTWEIGHT INSULATING CONCRETE 1

Soil Suction. Total Suction

ALUMINUM ELECTRICAL WIRING

Calorimetry: Heat of Vaporization

Microcontroller to Sensor Interfacing Techniques

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

Experiment 12E LIQUID-VAPOR EQUILIBRIUM OF WATER 1

APPLICATION NOTES. Bimetal Disc Thermostat. Operating Principle

Signal Conditioning Wheatstone Resistive Bridge Sensors

An Assessment of Radiator Performance

Lab 3 - DC Circuits and Ohm s Law

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Low Cost, Precision IC Temperature Transducer AD592*

2-SLICE COOL TOUCH TOASTER

We will study the temperature-pressure diagram of nitrogen, in particular the triple point.

Thermochemistry. r2 d:\files\courses\ \99heat&thermorans.doc. Ron Robertson

FXA Candidates should be able to : Define and apply the concept of specific heat capacity. Select and apply the equation : E = mcδθ

Experiment 1: Colligative Properties

Temperature. Temperature

USB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright Pico Technology Limited. All rights reserved.

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

Carbon Cable. Sergio Rubio Carles Paul Albert Monte

Pre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E

METHODS FOR THE CALIBRATION OF ELECTROSTATIC MEASURING INSTRUMENTS

Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

EXPERIMENT 7 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Lab 1 Diode Characteristics

Weight Measurement Technology

2. Room temperature: C. Kelvin. 2. Room temperature:

The following document contains information on Cypress products.

Low Voltage, Resistor Programmable Thermostatic Switch AD22105

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

States of Matter and the Kinetic Molecular Theory - Gr10 [CAPS]

15. Liquid-in-Glass Thermometry

The First Law of Thermodynamics

Thermal Flow Sensor Die

Precision Diode Rectifiers

Transcription:

University of Toronto ADVANCED PHYSICS LABOATOY NEEL Phase Change in Chromium At the Néel Temperature evisions: January/August 2016: October 2005: Original: David Bailey <dbailey@physics.utoronto.ca> Jason Harlow John Pitre Copyright 2016 University of Toronto This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 Unported License. (http://creativecommons.org/licenses/by-nc-sa/4.0/)

INTODUCTION Many solids undergo structural transformation as the temperature is changed. These are analogous to phase changes from gas to liquid or from liquid to solid except that in a structural transformation both phases are solid. Some of these transformations result from the onset of magnetic order in the solid, for example the ordering of atomic magnetic moments which occurs at the Curie temperature of a ferromagnet. Chromium is unique among metals in that the magnetic transition is from a paramagnetic (high temperature) phase to an anti-ferromagnetic 1 (low temperature) phase, at the Néel temperature, T N ~37.5 C. Also, the transformation is thermodynamically of the first order, which means that there is a latent heat (L=ΔQ) and a volume change (ΔV) at T N. Most magnetic transitions are second order, with a change in the specific heat (dq/dt) and the thermal expansion (dv/dt) at the transition temperature. The magnetic transition in Chromium is more easily detected by the volume change, ΔV, than by the small changes in the magnetic properties which occur when the metal becomes antiferromagnetic. In this experiment we measure the fractional length change, ( Δ / ), which is related to the volume change by ΔV V = 3 Δ We can calculate the latent heat per unit volume of the transition, L, using the Clausius- Clapeyron equation 2, dp L = dt N T N (ΔV /V) and the fact that the Néel temperature is depressed by pressure and the rate of dt N = 5.1K/kilobar (3) dp As can be seen in the short article by Matsumoto and Mitsui, Chromium undergoes a contraction when it passes from the antiferromagnetic phase to the paramagnetic phase (Matsumoto and Mitsui Figure 1) and also the coefficient of thermal expansion is larger in the paramagnetic phase than it is in the antiferromagnetic phase (Matsumoto and Mitsui Figure 2). EXPEIMENT A semiconductor strain gauge ( gauge rhymes with page ) has been glued to the Chromium sample and immersed in a Silicon oil bath for temperature stability. A copperconstantan thermocouple 3 is also held in place quite close to the sample, as shown in Figure 1. Preliminary temperature measurements may be done with a digital external thermometer dipped in the oil to give a rough indication of temperature. (1) (2) 1 Introduction to Solid State Physics by Charles Kittel (8th edition 2004 by John Wiley & Sons) Chapter 15, subsection on Antiferromagnetic Order 2 Heat and Thermodynamics by Mark Zemansky and ichard Dittman (7 th edition 1996 by McGraw-Hill) Chapter 11, sub-section on Clapeyron equation 3 Type T Cu versus Cu-Ni Alloy Thermocouples Data Tables, available on reserve in MP250 2

Safety eminders To avoid burns, do not touch the hot plate surface when it is on, or until it has cooled down after being turned off. Silicon oil is slippery and is very hard to wash out of your clothes. Clean up any spills promptly with paper towels. NOTE: This is not a complete list of all hazards; we cannot warn against every possible dangerous stupidity, e.g. opening plugged-in electrical equipment, juggling cryostats,. Experimenters must constantly use common sense to assess and avoid risks, e.g. if you spill liquid on the floor it will become slippery, sharp edges may cut you,. If you are unsure whether something is safe, ask the supervising professor, the lab technologist, or the lab coordinator. If an accident or incident happens, you must let us know. More safety information is available at http://www.ehs.utoronto.ca/resources.htm. to Wheatstone bridge oil to ice bath and Temperature voltmeter Strain Gauge Chromium Sample Copper Base Thermocouple Figure 1: Arrangement of the Chromium Sample, Strain Gauge and Thermocouple in the Silicon oil bath. The Strain gauge is glued to the top of the Chromium Sample. The Chromium Sample sits on the Copper Base. The entire apparatus is immersed in the oil bath in a glass beaker. As the bath temperature is raised, the output of a Wheatstone bridge is plotted versus temperature, and the appearance and approximate magnitude of the singularity due to Δ / at T N is noted. After preliminary setup runs have been performed a final run should be made with decreasing temperature and with the bath wrapped in cloth to ensure that the temperature decreases very slowly. 3

The Strain Gauge This information on the BCM BCM semiconductor strain gauge is taken from the manufacturer specification 4 BCM Gauge Type Number Doping of semiconductor Effective length at zero strain esistance at 23 C Temperature Coefficient of esistance SN5-120-P-1 / SN-120-5-P p-type 5 mm 120 ± 5% Ω <0.15%/ C Gauge Factor at 23 C 110 ± 5% Temperature Coefficient of Gauge Factor <0.15%/ C The gauge factor relates strain to fractional change in resistance, and is defined as F = Δ / Δ / In fact the gauge factor depends on temperature, and is given by F = F 0 + m F (T T 0 ) (5) where T 0 =21 C. Similarly, the total resistance of the gauge at zero strain was measured to have a slight dependence on temperature, so that the total resistance is given by: = 0 + m (T T 0 ) (6) Measuring the Coefficient of Thermal Expansion Since the gauge expands as the chromium expands, the strain we measure is due to the difference in the coefficients of thermal expansion of chromium and the silicon from which the gauge is made. The measurement of the strain is obtained from the change in the resistance as the temperature rises but the resistance of the gauge itself is a function of temperature so this effect must be considered as well. In fact the gauge was chosen to have a negative gauge factor so that effects of thermal expansion would be somewhat compensated for by changes in resistance due to rise in temperature. Strain is defined as Δ /. The apparent strain we measure over a change in temperature, ΔT, which does not include a phase change, is Δ / ΔT = α Cr α Si + m 0 F where the coefficient of thermal expansion of the Silicon strain gauge is α Si =2.52 10 6 C 1, and α Cr is to be determined. Note that in Chromium the coefficient of thermal expansion above the Néel Temperature may be different than that below. Temperature Measurement: Ni-Cu Thermocouple The thermocouple applies the Seebeck effect, which is the production of a small voltage across the length of a wire due to a difference in temperature along that wire. This effect is most (4) (7) 4 https://www.bcmsensor.com/wp-content/uploads/2015/09/semiconductor_strain_gauges.pdf 4

easily observed and applied with a junction of two dissimilar metals in contact, each metal producing a different Seebeck voltage along its length, which translates to a voltage between the two unjoined wire ends, as shown in Figure 2. T Figure 2: A single junction of two different metals (Nickel and Copper), which produces a small voltage between the free ends. This voltage increases with the temperature of the junction, T. The problem with this effect is that it is impossible to measure for a single junction. Once you attach a voltmeter to the free ends, you will always create another junction of dissimilar metals. For example, if your voltmeter uses copper leads, there will be a new Nickel-Copper junction which will also produce a voltage. For this reason, a thermocouple is always composed of two junctions, and only temperature differences can be measured, not absolute temperature. Figure 3 shows the setup used in this experiment, where T 1 is the temperature of an ice-water bath, and T 2 is the temperature of the oil in the beaker that contains the Chromium sample. T 1 Ni Cu Cu T 2 Ni Cu V Figure 3: Two junctions combined in a circuit with a voltmeter. T 1 is a reference temperature, T 2 is the temperature we wish to measure. The measured voltage is proportional to the difference T 2 T 1. The voltage produced by the thermocouple is on the order of a milli-volt. To measure this with the computer, it is first amplified by the high impedance voltmeter. You must calibrate the output of the voltmeter by comparing it to the reading on the dial, and perhaps adjusting the isolated output and zero dials on the voltmeter. You may assume that the dial is calibrated properly. Strain Gauge esistance Measurement: The Wheatstone Bridge There are several acceptable arrangements of the Wheatstone Bridge which can produce usable results for measurement of strain gauge resistance. The suggested arrangement shown in Figure 4 was designed to give maximum sensitivity to departures from equilibrium. 5

V 1 2 1.5 V v SG Figure 4: Wheatstone Bridge When 1 = 10 2, and V = 10 SG, the voltage across the bridge read by the voltmeter will read zero. Small changes in SG due to strain will lead to easily measureable voltages across the bridge. In this particular system, the two fixed resistances are 1 =1000 Ω and 2 =100 Ω, the resistance of the strain gauge is approximately SG 120 Ω, so variable decadal resistor should be set to approximately V 1200 Ω. To aid in calibration of the system, it may be noted that a change of 1 Ω in the variable resistor, V, causes a voltage change from equilibrium which is almost identical in magnitude to a change of 0.1 Ω in the strain gauge. Finally, the condition that the power dissipated in the strain gauge (6 mw) is less than 20 mw is fulfilled with this setup. The voltage you wish to measure is on the order of milli-volts, and should first be amplified by the milli-microvoltmeter. You should check the output is calibrated properly, so that the computer readings match that of the dial on the milli-microvoltmeter. In this experiment, the computer is being used as a two-channel volt-meter. The first channel voltage, which is related to the strain gauge resistance, is plotted on the y-axis. The second channel voltage, which is related to the temperature difference of the two ends of the thermocouple, is plotted on the x-axis. Data may be printed directly or saved in text format and read into an analysis program, such as Excel. Measurements to be Made The following points could be considered in presenting and discussing your experimental data: The magnitude of Δ / at T N should be determined with as high accuracy as possible, since this is the main purpose of the experiment. 6

The sign of Δ / should be shown to be consistent with the sign of dt N /dp and a positive latent heat, L, in going from the low temperature antiferromagnetic phase to the high temperature paramagnetic phase. Evaluate L from equation ΔV V = 3 Δ (1). Determine T N. Determine the width of the transition by changing the temperature very slowly through T N. Use equation Δ / ΔT = α Cr α Si + m to evaluate the coefficient of thermal 0 F expansion of Chromium, α Cr, both above and below the Néel temperature. Is there thermal hysteresis 5 in the system? For example, does a plot of Δl / l versus temperature depend on whether the temperature is rising or falling? BIBLIOGAPHY T. Matsumoto and T. Mitsui, Thermal Expansion of Chromium Single Crystals at the Néel Temperature, Journal of the Physical Society of Japan, 27 (1969) 786; http://dx.doi.org.myaccess.library.utoronto.ca/10.1143/jpsj.27.786. 5 I. S. Williams and. Street, Investigation of thermal hysteresis near the Neel transition in chromium, Journal of Physics F: Metal Physics 10 (1980) 2551-2553; http://iopscience.iop.org/article/10.1088/0305-4608/10/11/026/pdf 7