User s Manual for Aimpoint CompM2 and Aimpoint CompML2

Similar documents
Features: Mounting the Optic

Installation and use of Millett Tactical TRS-1 and TRS-2 scopes TRS-1 TRS-2. Before starting, make sure firearm is UNLOADED!!

VISM CQB Scope Series

The Vortex Spitfire 1x Prism Scope

VISM Evolution Scope Series

30 mm Diameter Main Tube 1-4x24 Models

CrossFireII. 1-Inch Diameter Main Tube RIFLESCOPE MANUAL RIFLESCOPE RIFLESCOPE

ENHANCED COMBAT OPTIC (ECO)

RIFLESCOPE RIFLESCOPE MANUAL

Preisliste Endverbraucher CH CHF.

RAIL ADAPTER SYSTEM DRAFT TC-23-AIMSS CHAPTER DESCRIPTION

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

M1A/M14 5/8-24 thread adapter Installation Instructions

MODELS 93/693 By CO2 SEMI-AUTOMATIC

18-270mm F/ Di II VC PZD for Canon, Nikon (Model B008) mm F/ Di II PZD for Sony (Model B008)

Morini CM 22M. Technical Data

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions

FX TYPHOON 12. Table of Contents

EF-S18-135mm f/ IS

P22 Cal..22L.R. Operating Instructions. Semi-Automatic pistol USA. anl_us~1.qxd :52 Seite 1. extractor

Operator s Maintenance Manual STEINER BINOCULARS. Military ruggedness and precision 07/03

EF70-300mm f/4-5.6 IS USM

NIGHT VISION MONOCULAR PHANTOM

Morini CM 162EI. Technical Data

Milwaukee USER MANUAL

SP AF 90mm F/2.8 Di Macro 1:1 (Model 272E)

EF-S18-55mm f/ IS II COPY ENG. Instruction

Installation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT!

4RU High Density Shelf Installation Instructions

HS-T RIFLESCOPE. riflescope manual. Second Focal Plane MOA

AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17)

12 Volt 30 Amp Digital Solar Charge Controller

Red dot sights 2010 Aimpoint AB STICKY FINGERS

EF24-105mm f/4l IS USM

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

EF-S55-250mm f/4-5.6 IS STM COPY ENG. Instructions

CALIBRATION FOR LAL20X & LAL24X

EF70-200mm F2.8L IS USM. Instruction

HS LR RIFLESCO PE HS LR RIFLESCOPE. riflescope manual. First Focal Plane Reticle

DEPENDABLE ACCURACY. RIGHT TO THE POINT.

Optical Ranging System (BORS )

EF70-300mm f/4-5.6l IS USM

Installation Instructions S

WARNING: This product contains chemicals known to the state of California to cause cancer, or birth defects or other reproductive harm.

suggested by the manufacturer of the scope mounts. The scope is positioned in the rings allowing correct eye-relief. You should see a complete field

GENUINE PARTS INSTALLATION INSTRUCTIONS

ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225

National- Spencer Inc.

Quick start guide smart.power smart.power smart.power

4.3-inch Back-Up Camera

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Compliments of SwatchBattery.com

Treasure Cove Metal Detector

The Krasnogorsk-3. Operating Instructions. Sold by NCS Products, New York

Traditional Sonar and DSI Sonar Installation

Global Water Instrumentation, Inc.

TacDriver T4i. The rugged TacDriver T4i series is packed with features:

MACRO PHOTO LENS. MP-E 65mm f/ ENG. Instruction

SP AF 17~50 mm F/2.8 XR Di-II LD Aspherical [IF] (Model A16)

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

Installation Instructions

LED MOTION ACTIVATED FLOOD LIGHT

TABLE OF CONTENTS 11.0 WARRANTY

TIPPMANN. A-5 Owner s Manual CO2 POWERED PAINTBALL MARKER

1.8 CRANKSHAFT OIL SEALS

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

HATSAN BREAK BARREL AIR RIFLES

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

Owner s Manual

#12 Professional Meat Grinders

User s Manual. Copyright 2014 Trick Technologies Oy

Action Camcorder Rollei Youngstar USER MANUAL

GLOCK "SAFE ACTION" Gen4 GEN4 PISTOLS NEXT GENERATION OF PERFECTION

PowerLine Magnetic-Laser Sheave Alignment System Instructions

How To Use A Meter

SHUTTER REMOTE USER MANUAL UNIVERSAL WIRED & IR RS-UWIR100 COMPATIBLE WITH MOST DSLR CAMERAS

INSTRUCTIONS FOR ANALOGUE QUARTZ AND MECHANICAL WATCHES

INSTRUCTION MANUAL (WINDOW WIPER)

100% Made in Taiwan Manufactured by G&G ARMAMENT

www. ATIgunstocks.com Page 1

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

In-Ground Basketball System Owners Manual

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Assembly and Usage Instructions

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Wireless Indoor/ Outdoor Thermometer

EasyNote TJ Series. Disassembly Manual

Part Name/Description Part Number Quantity. Power Cable

Mini multi-purpose sewing machine

San josé OWNER S MANUAL

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

UT202A Operating Manual. Contents

Day / Night IR Color Camera User Manual V2.1.0

Your new scope must be properly mounted to ensure accurate and reliable use in the field. Here are some of the basics: All base and ring screws

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

Transcription:

User s Manual for Aimpoint CompM2 and Aimpoint CompML2 Aimpoint AB Jägershillgatan 15 SE-213 75 Malmö, Sweden Phone +46 (0)40 671 50 20 Fax +46 (0)40 21 92 38 e-mail info@aimpoint.se www.aimpoint.com Aimpoint Inc. 7702 Leesburg Pike Falls Church, Virginia 22043, USA Phone +1 (703) 749 2320 Fax +1 (703) 749 2323 e-mail info@aimpoint.com www.aimpoint.com Copyright 2001 Contents property of Aimpoint All right reserved [10590]

1 CHAPTER I 1.1. Presentation Aimpoint s Reflex Sights are rugged precision electronic optical red dot sights developed for civilian, military and law enforcement applications. Aimpoint sights are designed for the two eyes open method of sighting, which greatly enhances situational awareness and target acquisition speed. Thanks to the parallax-free design, the dot follows the movement of the user s eye while remaining fixed on the target, eliminating any need for centering. Further, the sight allows for unlimited eye-relief. The CompM2 is compatible with 1 st, 2 nd and 3 rd generation night vision devices, while the CompML2 is optimized for applications, which do not require night vision compatibility. Aimpoint has now introduced the CETechnology, a radical advancement in red dot sighting performance with over 30 times longer battery life than the existing XD - sights. 1.2 Specification Model CompM2, CompML2, CompM2-2X and CompML2-2X Material - housing: Extruded, high strength aluminum, anodized Surface finish: Hard Anodized, Graphite Grey, matte Material lens covers: Thermoplastic elastomer, black, non-glare Optical magnification: 1X for all models except for 2X Eye relief: Unlimited, no centering required Optical coating: Anti Reflex coating, all surfaces Multi-layer coating for reflection Band Pass coating for NVD compatibility (CompM2) Dot size: 4 MOA except for 2X, which has 2 MOA dot size Switch, dot brightness: CompM2 / M2-2X: 10 positions: 4 NVD, 6 daylight of which 1 Extra Bright CompML2 / ML2-2X: 10 positions: 1 Off, 9 daylight of which 1 Extra Bright Battery: One 3 Volt Lithium battery type 2L76 or DL1/3N Battery life* (hours): 1000 10.000 h (typically 10 years at CompM2 NVD position)

2 Length (incl. lens covers): CompM2 / ML2: 130 mm (5.1 ) CompM2-2X / ML2-2X: 165 mm (6.5 ) Width / height: CompM2 / ML2: 55 mm (2.2 ) CompM2-2X / ML2-2X: 60 mm (2.4 ) Weight (incl. lens covers): CompM2 / ML2: 200 gram (7.1 oz) CompM2-2X / ML2-2X: 290 gram (10.2 oz) Adjustment: Range ±2,5 m at 100 meters, in windage and elevation 1 click = 10 mm at 80 meters = Mounting: 13 mm at 100 meters = 1 /2 at 100 yards. One wide ring, 30 mm diam, or Aimpoint QR Ring Max temperature range: -45 C to +70 C (-50 F to +160 F) Water resistance: Submersible to 25 m (80 ft) water depth** * Average values, depending on brightness setting **Tests performed have shown that sights will stand over 100 meters (330 ft) of water depth. MOA: Minute Of Angle 1MOA = 30 mm at 100 meters = 1 at 100 yards NVD: Night Vision Device 1.3 Location and description of major components and functions See fig. 1 1. Battery Lid 2. Battery (DL1/3N or similar) 3. Cover for adjustment screw 4. Adjustment Screw (windage/elevation) 5. Rotary Switch 6. Rubber Strap 7. Eye Protection 8. Lens Cover, rear 9. Lens Cover, front 10. Lens Cover for 2X Booster

3

4 CHAPTER II OPERATION UNDER NORMAL CONDITIONS 2.1. ASSEMBLY AND PREPARATION FOR USE WARNING: Insure the weapon is unloaded and the safety selector is in the safe position before attempting to install, remove or perform maintenance on the sight. 2.1.1. Installing Battery a) Remove battery cap by turning it counterclockwise. b) Insert battery with positive (+) end toward cap. Caution while replacing battery (not necessary when the sight is unused) Before installing battery cap, inspect that the O-ring is present and not damaged. Failure to do so could result in water leakage into the battery compartment. c) Install battery cap by turning clockwise until snug. Hand tighten only. Using tools could damage equipment. d) Verify that red dot is present by turning the rotary switch clockwise. 2.1.2. Installing Ring and Sight on the weapon Aimpoint s sights are designed for installation on most types of weapons. If your weapon does not have or support an appropriate base(s), please consult your dealer, gunsmith or other qualified source. a) Assemble the sight to the weapon by using Aimpoint s wide 30 mm ring or QR-mount. If other standard 30 mm rings are used, make sure that the ring(s) covers a length of minimum 25 mm or 1 (two standard rings could possibly be used). b) Ensure that the sight is correctly positioned for right or left hand shooting, see fig 2 and 3. c) When using lens covers, ensure that they are correctly positioned and can be opened.

5 NOTE: make sure that you have space between the bottom front part of the sight and the top of the base/weapon. d) Finally, make sure that all screws are firmly tightened around the sight. e) Complete the zeroing (2.2.1). 2.2. OPERATING PROCEDURES 2.2.1. Zeroing Aimpoint s sights are delivered in a centered position. Normally this means that only small adjustments are necessary, providing that the base(s) are properly aligned. CAUTION: Do not continue to adjust windage and elevation mechanisms if you encounter resistance. The elevation adjustment screw is located on top of the sight, while the windage screw is located on the right or left side, depending on how the sight has been mounted on the weapon. (Aimpoint sights can be installed to support either right hand (fig 2) or left hand (fig 3) shooters.) a) Open front and rear lens covers. b) Turn the rotary switch clockwise until the red dot has a sufficient intensity to contrast against the target. c) Remove the windage and elevation adjustment caps. NOTE: Each click of the adjustment screw corresponds to a 10 mm movement of the point of impact at 80 meters, (3 mm at 25 meters, 13 mm at 100 meters and 25 mm at 200 meters or 1 /4 at 50 yds, 1 /2 at 100 yds and 1 at 200 yds). d) Insert adjustment tool (coin, screwdriver, knife) or cartridge casing in adjustment screw slot and turn as follows: To move the point of impact to the right, turn windage adjustment screw counterclockwise (clockwise if screw located on left side). To move the point of impact to the left, turn windage adjustment screw clockwise (counterclockwise if screw located on left side).

6 To move the point of impact up, turn elevation adjustment screw counterclockwise. To move the point of impact down, turn elevation adjustment screw clockwise. e) Confirm zeroing by firing at least three shots at a zeroing target. Check impact points on zeroing target to confirm accuracy and repeat above procedure if required. f) After initial firing, ensure that the mount and sight are secure. g) Turn rotary switch to OFF position (counterclockwise). h) Close front and rear lens covers. CHAPTER III OPERATION UNDER EXTREME CONDITIONS a) Extreme heat (moist or dry). No special procedures required. b) Extreme cold. Extreme cold might shorten battery life. Keep spare batteries in your inner pockets to keep them warm. c) Salt air. No special procedures required. d) Sea spray, water, mud and snow. Ensure that battery cap and two adjustment screw caps are tight before exposing the sight to sea spray, mud, snow or before immersing the sight in water. Hand tighten only. Keep lens covers closed when sight is not being used. Clean lenses with lens paper/cloth and wipe the sight dry as soon as possible after exposure to water, sea spray, mud or snow. e) Dust storms and sand storms. Keep lens caps closed when sight is not being used. f) High altitudes. No special procedures required. CAUTION: The lenses shall never be cleaned with fingers but with lens paper/cloth. If no lens paper/cloth available : - To clear away debris (sand, grass etc): blow away the dirt. - To clean lenses: mist up the lenses and dry them with a clean and soft piece of cloth.

7 CHAPTER IV TROUBLE SHOOTING PROCEDURES 4.1 RED DOT DOES NOT APPEAR Discharged battery Replace battery Battery installed incorrectly Remove and reinstall battery with (+) toward cap Battery is not making good contact Clean contact surfaces and reinstall battery. Defective rotary switch Notify dealer/armourer 4.2 IMPOSSIBLE TO ZERO Adjustment screw is at its limit Impact point is moving Check alignment of mount to barrel Check mount stability CHAPTER V MAINTENANCE a) This reflex sight does not require any particular maintenance while used under normal conditions. b) Under severe weather conditions please refer to chapter III. c) Keep lens covers closed whenever the sight is not in use. d) Warehouse storage: Remove battery and allow lens surfaces to dry completely (if wet) before closing the lens covers. e) To clean lenses refer to CAUTION in chapter III.