OCTANE DETERMINATIONS

Similar documents
COMOC-V. Operational and Technical Overview

Features. Emerson Solutions for Abnormal Situations

The software beyond the climatic. Environment simulation

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

ADU 5. Automatic Distillation Unit

Smart. Scalable. Simple.

US Environmental Protection Agency Office of Pesticide Programs

6.2.2 TECHNICAL ARGUMENTS FOR OWN SCADA AND OWN SCADA WITH PID CONTROL.

site monitoring Kit Site Monitoring Kit User Manual we prove it.

Signature and ISX CM870 Electronics

How to Verify Performance Specifications

NEW. EVEN MORE data acquisition and test stand automation

TC-9102 Series Surface Mount Temperature Controllers

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Diagram of components 2. Reducer..3

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

X2 series balances INNOVATIVE FUNCTIONAL SOLUTIONS

ADT Payload Monitoring System TEchnology carved for the toughest job

Wireless Data Logger Monitoring Systems

Frequently Asked Questions

Process Instrumentation

Auslogics BoostSpeed 5 Manual

5,000 lb Capacity. Wireless Communication Scale

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Contact. Workshop on advanced flow computing with the SUMMIT March 24 27, May 19 22, August 18 21, November in Breda, The Netherlands

CALIBRATION PRINCIPLES

CHROMOCTANE O N LINE ANALYZER

SSI Technologies TULC Application Note

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Interfacing with Manufacturing Systems in Education and Small Industry Using Microcontrollers through the World Wide Web

Metering for today s systems

TMO2D with Fault Alarm and Event Log. Software Version 4B (or Earlier) Using the Fault Alarm

Job Scheduler User Guide IGSS Version 11.0

Compact Monitoring Technology your environmental monitoring solution

Computer Creep System

The Sievers 900 Series TOC Analyzers

Gravimetric determination of pipette errors

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

AUTOMOTIVE DYNAMOMETER HARDWARE AND SOFTWARE

Data Validation and Data Management Solutions


The Business case for monitoring points... PCM architecture...

Technical Service Bulletin

Device Management Jonas Berge Emerson Process Management

G-100/200 Operation & Installation

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Fire Safety Risk Assessment Checklist for Residential Care Premises

SCADA Systems. Make the most of your energy. March 2012 / White paper. by Schneider Electric Telemetry & Remote SCADA Solutions

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

DIGITAL DISPLACEMENT RISING STEP LOAD LRA/RSL TEST EQUIPMENT

Why and How we Use Capacity Control

5100 Spreader Control Event Logging Installation, Calibration and Operation Manual

Distribution Voltage Regulators

Automated Inventory System

NetVue IMS, Bandwidth Manager & Heights Networking Platform Course Description

A/C refrigerant system, overview

POWER. Your Partners in Availability POWER

How To Control A Medical Device With A Pc System

ScreenMaster RVG200 Paperless recorder FDA-approved record keeping. Measurement made easy

LIBERO: Innovation Leader in Cold Chain Monitoring

Deploying VSaaS and Hosted Solutions Using CompleteView

Fuel Requirements for HCCI Engine Operation. Tom Ryan Andrew Matheaus Southwest Research Institute

Licenses of savic-net for Integrated Building Management System, and for FDA Title 21 CFR Part 11 Compliance

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

Table of Contents. 1. Product Overview Proposed Solution System Architecture Key Modules & Features...

Concremote calibration box

Cover sheet. How do you create a backup of the OS systems during operation? SIMATIC PCS 7. FAQ November Service & Support. Answers for industry.

Webnet2000 DataCentre

Alber Training and Education Product Tutorial. Battery Monitor Data Manager Software (BMDM)

Computer Hardware, Network and Software Recommendations

The software solution to complete your flow monitoring program

MAX ENERGY POWER PROGRAMMER PART #52001/52501 REFERENCE GUIDE AND INSTALLATION MANUAL ADDENDUM JEEP WRANGLER WITH ENHANCED OFF-ROAD FEATURES

ATTACHMENT III Tender No HD Laboratory Information Management System (LIMS)

AC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance

Laptop Recorder OPERATION GUIDE. Laptop Serial Number (System ID): Original Seneca Data Order Number: SoniClear Order Number:

GE Mine Performance powered by Predix

MAGICAR M871A. Car alarm with two-way remote User s guide

WINDING RESISTANCE TESTING

MEASURE AND CONTROL INVENTORY MANAGEMENT CONSOLE (IMC) Console for stand alone use Console with PC interface, software & USB cable

Computerised Systems. Seeing the Wood from the Trees

Maximizing return on plant assets

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Automated Equipment Data Analytics to Detect Issues, Trends, Faults & Anomalies

MDS. Measured Data Server Online Measurement Network. Properties and Benefits »»» »»»» ProduCt information

DESCRIPTION. DTC P0351 Ignition Coil "A" Primary / Secondary Circuit. DTC P0352 Ignition Coil "B" Primary / Secondary Circuit

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

Understanding Safety Integrity Levels (SIL) and its Effects for Field Instruments

Lab E1: Introduction to Circuits

1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number

BASIC SOUND LEVEL METERS

MP280 / MP287 / MP288 MP495 / MP497 / MP498 SERVICE REFERENCE MANUAL

A&E Specifications RoadRunner HD High Definition Mobile Recording System

OIL PRESS 71.8 PSI FUEL. Cloud based, diagnostic, engine monitoring and reporting system.

UNIT 1 INTRODUCTION TO NC MACHINE TOOLS

Transcription:

A B usiness Unit of T he P rotectoseal C ompany On-Line & Laboratory Analyzers for the Determination of Octane Number Using the Falling Level Method (Conforming to ASTM Standards: D2699, D2700 & D2885) OCTANE DETERMINATIONS Electronic Systems Design (ESD), formerly based in Palatine, Illinois, has been an industry leader for almost 50 years, focusing on innovative solutions for determining the octane ratings of fuels. ESD is well-known for supplying On-Line and Laboratory Analyzers and for pioneering the use of the Falling Level Method (Dynamic Fuel Level) for octane number determination. Installation, parts and service are available throughout the world. Conforms to ASTM Standards ESD Representatives have been active participants in the development and maintenance of industry standards. All equipment meets or exceeds the requirements outlined in: ASTM D2699 Research Method, ASTM D2700 Motor Method and ASTM D2885 Test Method for Determining Octane Number of Spark-Ignition Fuels by On-Line Direct Comparison Technique. LAB SYSTEM On November 13, 2012, The Protectoseal Company became the parent company of Electronic Systems Design. ESD will operate as a separate business unit of The Protectoseal Company WHAT IS THE FALLING LEVEL METHOD? The ESD Octane Analyzer Systems employ the well-known and proven Falling Level (Dynamic Fuel Level) Method for determining the octane number of a fuel sample. This method is documented in ASTM D2699 - Standard Method for Research Octane Number of Spark Ignition Engine Fuel (Procedure B), ASTM D2700 - Standard Test Method for Motor Octane Number of Spark-Ignition Engine Fuel (Procedure B) and, by reference, in ASTM D2885 - Determination of Octane Number of Spark-Ignition Engine Fuels by On-Line Direct Comparison Technique. With the Falling Level Method, a specifically designed and calibrated fuel supply bowl is filled and is allowed to empty as the CFR test engine runs. The bowl design is such that a test cycle on any fuel sample can be completed in a reasonable amount of time while ensuring that a consistent and repeatable range of fuel mixtures are delivered to the engine without the need for intervention by the operator. As the liquid level in the supply bowl falls, the rate of fuel supplied to the engine decreases and the fuel / air ratio changes. The knock intensity of the engine is measured continuously over the range of fuel / air ratios. In a properly calibrated system, this is characterized by a light knock condition, through a peak knock measurement and then back to a light knock. The peak knock intensity levels of fuels with known octane numbers higher and lower than the sample fuel are plotted in a straight-line graph. The sample s octane number can then be determined by the position of its measured peak knock intensity along this plotted curve. The Falling Level Method has been statistically proven and accepted by the ASTM as a valid octane number determination procedure. Peak Knock Intensity Low Primary Octane Number Unknown Sample High Primary By comparing peak knock intensity with known reference fuels, a simple straight-line interpolation reveals the octane number of the unknown fuel. www.octamatic.com Page 1

SYSTEM OVERVIEW The Octamatic Octane Analyzer Systems are based on the Falling Level Method of measuring octane rating in fuel. This is a variant of the standard Bracketing Method (Procedure B) used by laboratories and refineries. Determination of the proper fuel air ratio is far more accurate than that obtained by manual methods. Unlike manual methods, the operator is out of the control loop which determines peak fuel / air ratio. Errors in recording, transcribing and calculating octane numbers are eliminated. There are two versions of the ESD Octamatic Analyzer: The and the LABORATORY SYSTEM. Both systems use the same high precision methods as described in ASTM D2699, ASTM D2700 and ASTM D2885. Economy One computer (plus one backup computer for on-line systems) can be used for the entire test lab. Incremental costs for additional engines beyond the first engine are small. The database generated by the system is tailored to each installation, at no additional charge. Reports are also customized and can be displayed, printed or sent to other systems. Data is stored permanently and can be transmitted to removable media, remote computer systems and/or networks. The ability to produce consistently at a specific octane number is extremely critical. The value of an octane barrel makes controlled production capability a moneymaker, not an expense. As competitive pressures mount and consumption declines, the need to make octane qualities of fuels as near to zero giveaway as possible increases significantly. Whatever octane determination method is used, ESD Analyzers enable the on-line blending and laboratory testing of octane quality to move into an area of precision that insures minimum of octane giveaway. Lower operating and maintenance costs are also realized. Ease of Operation Operators with previous experience on CFR engines quickly adapt to these new analyzers. The ESD Falling Level Octane Analyzer Systems are being utilized by many refineries and testing laboratories, because of the short amount of time it takes a technician to become proficient in producing quality octane numbers. In laboratories where it is required that many individuals product octane ratings, the ESD Falling Level Systems bring their site precision close to the method repeatability, as cited in the applicable ASTM Standards. The population of experienced technicians in the field of octane ratings is on a worldwide decline. Some have turned to spectroscopy to bridge this gap only to find that you must have precise octane data to make the spectroscopy models work. These models must be maintained due to the nature of the complexity of motor gasoline. With an ESD Octane Analyzer System installed on a well maintained CFR test engine you will have the real octane number, not a guess. FEATURES & BENEFITS General: Economical with a fast pay back on investment. Can run tests on multiple engines simultaneously and the system precision reduces octane giveaway. Is compliant with ASTM Standards: D2699 Research Method, D2700 Motor Method and D2885 Test Method for Determining Octane Number of Spark-Ignition Fuels by On-Line Direct Comparison Techniques. Very precise system eliminating manual data calculation and recording. Frees operator from continually adjusting fuel / air ratio. Always finds the fuel / air mixture resulting in maximum engine knock. Fuel / air ratio is adjusted automatically by the falling level of the fuel bowl. Features a UNIX operating system insuring a cost effective capability that is stable, reliable and expandable. Far superior testing of octane than manual means. Minimizes operator transcription errors (all data is handled by computer). Runs test on multiple engines simultaneously. ESD has installed systems with up to 14 engines. With properly maintained engines, a standard deviation of 0.06 (RON) and 0.08 (MON) can be reasonably expected. Includes automatic temperature control based on digital temperatures input monitoring for air intake and mixture temperatures for all engines. No moving parts, increasing reliability. Minimal maintenance; can be accomplished by in-house personnel. Water-cooled aluminum block brings fuel temperature down to ASTM requirements. Top cover on bowl reduces evaporative losses. Delivers customized hardware and software. Software & Programming: An interactive screen program through which the operator enters the variables of the blend to be analyzed, i.e. type of fuel to be made, and the blend size. All other factors are stored in the system and can only be changed under a supervisory menu. Examples: proto fuel to be used, blend name or sample ID. This reduces the probability that the operator will enter something in error. A menu which lists the supervisory programs. These include, but are not limited to, features that are not normally available to the operator, such as performing spread calibration, proto rating, ASTM qualification, NEG rating, proto tank record maintenance, system parameter settings, system calibrations, records management, and running historical reports (ASTM checkout, proto rating, blend files, spread cal runs, NEG history, SQC history). The system keeps a complete history of all activities listed above that have been performed since installation. www.octamatic.com Page 2

FEATURES & BENEFITS (continued) Application programs written in DecisionPlus and C++ to operate the system at each engine. A continuously running scanner program to read all the analog and digital signals at high speed. A moving average is maintained on all variables, resulting in precise, noise-free data acquisition. Hardware: Includes UNIX-based system for high reliability, reduced costs and ease of expansion. 300 gigabyte RAID hard drives for program and data reliability. Color printer for reports. Uninterruptible power supply for entire system. Engineering & Installation: Professional installation and startup will be performed by Electronic Systems Design field engineer(s). Optionally, a software engineer may also be on-site, if needed, during startup and commissioning. (This will be determined on a site-by-site basis.) Operator and supervisory training is included, which will be done during the installation phase. Our policy is to stay on-site until the project is complete and the customer is satisfied that all training has been done and everything is working properly. If there is a problem during the first twelve (12) months that your staff cannot resolve, we will make a return trip at no charge. ENGINE PARAMETERS ESD Octamatic Systems typically monitor the engine parameters shown below and are delivered with alarm and warning limits consistent with the relevant ASTM specification. These limits are easily changeable by the customer. Air refrigerant temperature Proto and product fuel temperatures Product pressure (switch) SEMI-AUTOMATIC LAB SYSTEM Engine coolant temperature Fuel temperature MANUAL LAB SYSTEM Engine coolant temperature Fuel temperature www.octamatic.com Page 3

ALARMS & WARNING LIMITS Alarms are considered more serious than warnings; the occurrence of an alarm requires corrective action before measurements can continue. Alarms and warnings are displayed to the operator and must be cleared by the operator. In addition, some alarms act as a backup to the safety systems provided by the engine manufacturer. Coolant temperature over 220 F. under 20 PSI QC bowl became full during blending (indicates level sensor failure) Excessive proto drift from previous proto measurement Rate of change of delta O.N. too large Delta octane out of user-specified range Product pressure low (optional) out of operating range Product O.N. out of range Proto K.I. over 80 or under 20 Product K.I. over 99 or under 10 Any abnormal exit from blending screen SEMI-AUTOMATIC LAB SYSTEM Coolant temperature over 220 F. under 20 PSI out of operating range K.I. over 99 or under 10 MANUAL LAB SYSTEM Coolant temperature over 220 F. (optional) under 20 PSI (optional) out of operating range (optional) K.I. over 99 or under 10 www.octamatic.com Page 4

COMPREHENSIVE REPORT GENERATION Blend History Report Detailed record of each blend Graphs of blend results: delta O.N., Proto K.I. System Configuration Reports Customer-changeable parameters, their current values and ranges Sensor calibration and alarm / warning limits Proto Tank Definitions Report O.N., ID, tank #, correlation to reference fuel used to rate, etc. Pre-Blend Checkout Report Pre-blend (SQC) runs, with details ASTM Checkout Report Proto Rating Report Historical Pre-Blend Checkout Report Archived SQC reports associated with proto fuels no longer used Current Spread Table Spread Run Report Historical ASTM Checkout, Proto Rating and Spread Run Reports NEG Exchange Fuel Rating Report Graphs of Blend Results Alarm Log Report per Engine Detailed Log of Internal System Operations LABORATORY SYSTEMS Measurement Results Report Report may be optionally printed (userselectable) at the conclusion of each test Historical reports of all ratings made by system are available for the life of the system Summary Results Report, sorted by date or ID Provides summary of all tests performed over a given date range, including re-tests Detailed Summary Results Report, sorted by date or ID Same as above but with additional details and measurement parameters Sensor Calibration and Alarm / Warning Limits Report Report data may be optionally exported to readable media (CD/DVD-ROM, USB Memory Stick) Report data may be optionally exported to readable media (CD/DVD-ROM, USB Memory Stick) A Business Unit of The P rotectoseal C ompany 225 W. Foster Ave., Bensenville, IL 60106 Phone: 847.358.8212 Fax: 847.358.8214 www.octamatic.com Page 5