Manual oflms series intelligent solar controller

Similar documents
User s Manual Before using the inverter, you need to read and save the safety instructions.

PSC-A5 Solar Charge Controller Manual

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

2 Installation Explanation

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

How To Control A Battery Cell Phone With A Battery Power Control System

12 Volt 30 Amp Digital Solar Charge Controller

Solar Controller / Battery Charger User s Manual

SOLAR POWER - THE NEW WAY TO RV!

S10I / S20I / S30I Solar Light Controller USER MANNUAL

Tracer-1206RN / 1210RN / 1215RN. Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL

View Star series. Solar Charge Controller INSTRUCTION MANUAL

INSTRUCTION MANUAL EPSOLAR. Tracer-2210RN / 2215RN. Maximum Power Point Tracking Solar Charge Controller

BB800 Off-Grid Solar System

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

User s Manual. Wind/Solar Hybrid Controller NV-SW10C48. Please Read This User Manual Carefully Prior to Installation and. Operation of This Product.

Mobile Data Power Model: MDP-25

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SX460. Generator Automatic Voltage Regulator Operation Manual

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

3000W Power Inverter

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

ST Series POWER SUPPLIES USER INSTRUCTIONS

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

TIG INVERTER INSTRUCTION MANUAL

User s Manual AURORA 1.2K/2.2K

Online UPS. PowerWalker VFI 1000R/1U

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Advanced Wind/Solar Hybrid Controller. Model: WWS10A-48 Version 1.0

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

LITHIUM BALANCE CHARGER

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

14. Troubleshooting Guide

BITMAIN. APW PSU Series User Guide

Drayton Digistat +2RF/+3RF

Installation and Operation Guide for PD4100 Series Power Control Centers

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

DC/DC power modules basics

Table Of Contents

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Installation and Operation Guide for PD4000 Series Power Control Center

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

Battery Power Inverters

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Mounting instruction Read instructions carefully!

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

NI-ZN BATTERY SPECIFICATION

User Manual for CH-PFC76810

Emergency lighting units EM powerled

Kelly KBS-L Brushless Motor Controller User s Manual

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

User Manual 1K/2K/3K Online UPS

YSmart Technology Co.,Ltd

EDIC-mini TINY Model SOLAR 1120/2240/4480/8960/17920

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Back-UPS Pro 1300/1500 Installation and Operation

GV-Boost Manual. 8A Input / W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking

Thermo Top - Troubleshooting Tree

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

SOLAR POWER CONDITIONER Service Manual

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Safety technique. Emergency stop module BO 5988 safemaster

Instruction manual for Firstline FCS12000CH

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Installation and Operation Back-UPS 1250, 1300, 1500

Li-ion Rechargeable Battery. Specification

MOUNTING AND OPERATING INSTRUCTIONS

WVC300 Micro-inverter solar grid system (Power line communications)

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

DC Electronic Loads 8500 series

Thyristor-controlled power supplies and battery chargers

How To Use A Power Supply Unit (Upu)

Wind/solar hybrid controller instructions

13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

QUICK PROBLEM SOLVING GUIDE

RADIANT PLASMA 4700 Plasma Spark Generator

1. Scope This specification is applied to ICR Product Specification Table 1 No. Item Rated Performance Remark

Three-phase monitoring relay CM-PFE

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

GROWATT NEW ENERGY CO.,LTD. GR - UM

Charge Regulator SCR 12 Marine

Owner s Manual channel amplifier

Industrial Batteries / Motive Power Chargers 2100.NET.»For improved efficiency and durability«

Connecting your Victron product to a computer with VE Configure

Product catalogue. solar charge controller & inverter BEIJING EPSOLAR TECHNOLOGY CO., LTD. Tel: Fax:

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

SMART SENSOR COLLECTION

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Transcription:

Manual oflms series intelligent solar controller

LMS series intelligent solar controller Manual LMS series intelligent solar controller 文档说明 Thank you for choosing our solar controller product. This product manual will include product function properties, installation, usage, trouble clearance and so on. Before use, customer must read this manual. For any doubt, please contact us by the contact ways included in this manual. We will try our best to serve you. Contents Safety warning 2 1 Product properties 2 1.1 Specification parameters...................... 2 1.2 Charge management......................... 3 1.3 Load control mode.......................... 4 2 Installation method 4 3 Control and interface instruction 4 3.1 LCD instruction............................ 4 3.2 Start-up interface........................... 4 3.3 main interface............................. 4 3.4 Controller setting........................... 5 4 Troubleshooting and maintenance 6 5 Technical parameters 6 5.1 oltage parameters and threshold parameters of battery. 6 Safety warning During the installation and usage, please make sure to obey by the following safety regulations and notes to avoid the damage to controller. There is no maintainable part in the controller. User must not disassemble or repair the controller without permission. Before installing and adjusting the connection of controller, please make sure to disconnect the connection of photovoltaic panel and the fuse or breaker around battery terminals. After installation, check all the wire connections are reliable to avoid heat accumulation for virtual earth. 1. Product properties he LMS series intelligent solar controller of Guangzhou Limu Computer Technology Co., Ltd is equipped with industrialgrade STM 8 microprocessor to control the charge and discharge process and has perfect and reliable battery charge and discharge period management. The charge circuit is characterized by high efficiency and low consumption by controlling the MOSFET of ultralow internal resistance with PWM. This controller has multiple load control modes and is adaptable to different industries. The product can be applied to the following occasions: Outdoor environment monitoring system Automatic control system for agriculture and garden Solar power system Communication station, WIFI hotspot street lighting system Other systems which are supplied by solar energy and have requirement for power EMI indicator 1.1 Specification parameters This product is a new-generation solar charge and discharge controller for lead-acid battery. The product includes but is not limited to the following functions and properties: LCD displayer Excellent heat balance design and natural air cooling; 4-stage charge period management(equ Bulk ABS Float) Temperature compensation function. The controller can automatically adjust the charge parameters of battery by environment temperature to lengthen the service life of battery. Sophisticated electronic protection production, including overcurrent protection, load short-circuit protection and low-voltage protection. Comprehensive and reliable load control mode can identify the day and night. Well-designed charge loop can effectively improve the efficiency of charge and discharge, and reduce the heat consumption in charge and discharge. Statistics of charge volume of battery.

LMS series intelligent solar controller 3/8 Items LMS2410 LMS2420 LMS2430 LMS4810 LMS4820 LMS4830 System voltage /24 48 Maximum voltage of P 40 100 Maximum charge current 10A 20A 30A 10A 20A 30A Maximum discharge current 10A 20A 30A 10A 20A 30A Maximum output voltage /24 48 Maximum output power 120W/240W 240W/480W 360W/720W 480W 9600W 1440W Charge way 3-stage PWM charge Compatible battery lead-acid cell USB charge port 5/1A Temperature compensation Dimension 150*85*35mm Weight 230g Tab 1. controller configuration 1.2 Charge management Direct-charge is also called as quick charge. During this LMS series intelligent solar controllercontains built-in 4- stage, photovoltaic panel charges the battery quickly with stage charge management. The controller can charge the battery full power. When the battery gets close to constant voltage charge stage, the charge stage is shifted to constant rapidly, effectively and safely in PWM way according to preset charge parameters from 0 100% impulse width. Charge voltage charge. process is shown in Fig1. Constant-voltage 1 charge(abs) Under constant-voltage charge status, photovoltaic panel volt 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 o Lack of sun EQU Bluk ABS Float Fig 1. charge control period Equilibrium charge(equ) Lack of sun This stage will be activated only when the battery recovers from over-discharge to normal charge. Similar to direct-charge stage, photovoltaic panel charges the battery rapidly with full power until the battery voltage gets close to equilibrium. In the status of equalizing charge, continuous charging with high current and voltage will help to activate the battery and prevent the aging due to over-discharge. Direct-charge(Bulk) time voltage will be stabilized to the voltage of ABS (mean value) by PWM chopped wave in order to limit the charge rate of battery. It is beneficial to the conversion between electric energy and chemical energy in the battery and guarantees the full conversion of charge current. When offline voltage of battery is close to constant regulated voltage, the battery is fully charged. Floating charge(float) In floating charge status, voltage of photovoltaic panel is stabilized to the rated voltage of floating charge (mean value) to limit the charge rate of battery. This charge status is to continuously supplement the battery and make up the energy loss caused by self-discharge. In the loaded condition, voltage of floating charge also provides electric energy of photovoltaic panel for load. Some kinds of batteries are benefited from regular equalizing charge which can stir electrolyte and balance the voltage of battery to complete chemical reaction. Equalizing charge raises battery voltage and makes it higher than standard supplemented voltage, and gasifies battery electrolyte. It should be noted that the conversion of charge process has stages, for example, direct-charge is the only way to enter constant-voltage charge stage. Before the end of direct-charge

LMS series intelligent solar controller 4/8 stage, constant-voltage charge stage will not be activated. Only when battery voltage is lower than charge return voltage, controller enters into direct-charge stage, and then into constantvoltage charging stage after quitting direct-charge status until battery is finally full-charged. When battery is firstly connected to controller, if voltage of battery is higher than charge return voltage, charging will not be started even though voltage of photovoltaic panel is sufficient to charge the battery. Status of charge indicator light is shown in Fig2 1.3 Load control mode LMS series intelligent solar controllerhas 6 built-in load control modes which can meet most requirements of light control of solar lighting system. The 6 built-in load control modes are as follow: Similar to solo light control mode, the controller judges whether it is necessary to open or close the load by the voltage of photovoltaic panel. The controller controls load output by 100%, 50% and 30% PWM to lengthen the opening duration of load in 3 time sections. Manual mode (H mode) In manual mode, the opening or closing of load is manually controlled by button. Normal open mode (24H mode) In normal open mode, load will be outputted continuously, which is the so called 24h working mode. Charge mode (Ch mode) Load control takes no effect in this mode. That means controller only actives battery charge function and load is closed. Pure light-operated mode (L mode) 2. Installation 1 method Lack of sun,lasting for 10sec enough of sun,lasting for 1min Load is closed Load is open Load is closed time Fig 2. light-control mode In all related modes of light control, the controller can judge whether environment lighting is low enough to open the load according to the voltage of photovoltaic panel. In making the judgment, the controller must detect the voltage of photovoltaic panel lower than light-control load starting threshold for continuous 10sec. At this time, load is opened normally. When the voltage of photovoltaic panel is recovered to the value above light-control load starting threshold and remains the value for continuous 1min, the load is closed normally. The continuous threshold detection lasting for 10sec and 1min is to prevent false judgment caused by car light, lighting and other lights from circumstance. Light & timing mode (LT mode) Similar to solo light-control mode, photovoltaic panel will judge the openness of load by current ambient brightness. What is different is that after load is opened, even though the voltage of photovoltaic panel is lower than the loadclosing threshold within 1 13h, the controller will still shut down the load by timing and re-start the load again at dark. 3 Light-control stages (3L mode) LMS series intelligent solar controllerwill be heated during operation. It is a must to mount it to the surface made of nonflammable materials. Installation on large-sized metal piece is more beneficial to heat dissipation. Please follow the steps below in installation: Though the controller has inverse connection protection function, it is better to avoid the inverse connection of photovoltaic panel in engineered installation. Connection should be strong and reliable. Contact area of connector should be large enough to prevent virtual connection and heat accumulation caused by oxidation at connection. 3. Control and interface instruction Controller is equipped with a LC display and can be conveniently switched between modes and parameter configuration. Operation is convenient and simple. 3.1 LCD instruction LCD display description, as shown in Fig3 3.2 Start-up interface After powered, the controller will detect battery voltage and display the model, for example, 1210, as shown in Fig4. 3.3 main interface Displayed contents of main interface include battery voltage, voltage of photovoltaic panel, charge current and load output current. Press button to switch between the contents. as shown in Fig5 Fig6 Fig8 Fig7. Press button to switch between the contents.

LMS series intelligent solar controller 5/8 Indicator light status Charge status(green Light) Load status(red Light) OFF Insufficient voltage of photovoltaic panel, charge process is stopped. Load is closed Constant ON Ongoing constant-voltage charge Load is opened Slow blinking Battery is getting close to full-charge and float charge ongoing. Load is overcurrent Quick blinking Ongoing direct-charge or equilibrium charge Load is short-circuit Tab 2. status of charge/load indicator light Bulk Fig 5. battery voltage Fig 3. LCD Icon description Bulk Fig 6. voltage of photovoltaic panel Fig 4. starting interface 3.4 Controller setting Hold on the button,until LCD has display, as shown in Fig9,When Mode logo blinks with the frequency of 1Hz, it indicates that controller has entered into load control mode setting interface. The settable parameters of controller include load control mode, light-control timing, 3 time section duration setting, 3time section power percentage, battery low-voltage protection value, battery low-voltage return value, battery overvoltage value, and so on. User can switch different setting items by function button. If no setting is made in setting mode within 20sec, the controller will automatically return to main interface. Load control mode setting The first setting item of setting mode is load control mode, Fig9. Press button to select one load control mode, including 24H (normally on mode), CH (charge mode), H (manual mode), L (solo light control mode), Lt (lightcontrol timing mode) and 3L (light-control 3-time-section mode). When load control mode is set as H mode, press button to open and close the load. Light-control timer setting When load-control mode of controller is set as Lt (lightcontrol timing mode), press button to select until the display of LCD is shown in Fig10. And then,press button to adjust the duration in the range of 1 13h. 3-time-section duration setting When load control mode of controller is set as 3L (3- time-section mode), press button to select until the display of LCD is shown in Fig11 and Fig12. Set the duration of first and second time section, and then press upward and downward button to adjust duration within the range of 1 13h. If duration is set as zero, it indicates invalid time section. The third time duration will be set by the controller by the formula: night duration first time

LMS series intelligent solar controller 6/8 Bulk Mode A Fig 7. battery charge current Fig 9. Load control mode setting Bulk Mode A Fig 8. load current Fig 10. Light-control timer setting duration-second time duration. 5.1 oltage parameters and threshold parameters of power percentage setting of 3 time-sections battery When load control mode is set as 3L (3-time-section oltage parameters are shown in Tab4. Threshold parameters are shown in Tab5. mode), press button to select until the display of LCD is as shown in Fig16, Fig17 and Fig18. Adjust the power percentage of 3 time sections within the range of 1 100%. Battery low-voltage protection value setting Battery low-voltage protection setting is shown in Fig13 and the range is shown in Tab4. battery low-voltage return value setting Setting of low-voltage protection value is shown in Fig15,the range is shown in Tab4.To prevent the fluctuation of load at starting and closing,low-voltage protection value and low-voltage return value must have at least 0.2 voltage difference. Battery overvoltage setting Setting of low-voltage protection value is shown in Fig14,the range is shown in Tab4. 4. Troubleshooting and maintenance If the following abnormal situations happen in use, please check Tab3.If technical support is required, please record fault phenomenon and status of indicator light, and then contact us. 5. Technical parameters

LMS series intelligent solar controller 7/8 Abnormal phenomenon Possible cause Solution Though there is sufficient sunshine, charge indicator light is photovoltaic panel is disconnected or connected inversely. Check if photovoltaic panel is intact and polarity is correct. off. Load indicator light blinks Load is overcurrent. Check if the load is normal. slowly. Load indicator light blinks quickly. Load is in short circuit Check if the load is normal or connection is in short circuit. When load is closed, it shows sufficient energy;when load is opened, it enters low-voltage Bad connection of battery or wire diameter is too small. Check connection wire of battery or replace it with larger wire diameter. protection mode. Status shows full-charge soon after charge process is started. Overvoltage or overcurrent of charge Check if maximum charge current setting fits the maximum charge current of battery. If necessary, modify charge correcting voltage to lower down charge voltage. Tab 3. Faults and Solutions oltage parameter 24 48 Remark Over 14.6 29.2 58.4 Maximum charge voltage 14.4 16.8 28.8 33.6 57.6 67.2 ChRet 13.2 26.4 52.8 When charge return voltage and battery voltage is lower than this set value, controller will enter Directcharge. EQU 14.4 28.8 57.6 Equilibrium charge Bulk 14.0 28.0 56.0 Direct-charge ABS 14.2 28.4 56.8 oltage of constant voltage charge Float 13.8 27.6 55.2 Floating voltage Close 11.0 22.0 44.0 Low-voltage protection voltage. When battery voltage is lower than this value, 10.0 12.0 20.0 24.0 40.0 48.0 controller closes the load and enters into protection. ClsRet 12.4 24.8 49.6 Low-voltage return voltage. After entering into 10.8 12.6 21.6 25.2 43.2 50.4 low-voltage protection,battery voltage will resume this set value and open the load again. Coeff -0.021-0.042-0.084 Single battery temperature compensation voltage range: -3.5m -0.5m Tab 4. battery voltage parameters Parameters LMS2410 LMS2420 LMS2430 LMS4810 LMS4820 LMS4830 Light-control start threshold(p) 5/10 15 Light-control start delay 10S Light-control termination delay 60S Load overcurrent threshold 13A 26A 39A 13A 26A 39A Tab 5. Threshold parameters

LMS series intelligent solar controller 8/8 EQU Fig 11. first time section duration setting Fig 15. battery low-voltage return value setting Power Fig 12. second time section duration setting Fig 16. first time section power setting BatLow Power Fig 13. Battery low-voltage protection value setting Fig 17. second time duration power setting Power Fig 14. Battery overvoltage setting Fig 18. third time section power setting