2610 Modular Measurement and Control System

Similar documents
Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Test Report #: Date: April 8, 2005

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

TEST REPORT EN (1997) +A1 (2001)

EMC Test for Compliance with EU EMC Directive 2004/108/EU

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

EMC TEST REPORT For. Webcam. Model Number: CAM67U

Declaration of Conformity.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Declaration of Conformity.

Electromagnetic Compatibility Test Report Test results of Floww equipment

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

Waveguide Access Point WGA631. Product Guide

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

Declaration of Conformity.

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

Current Probes. User Manual

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

Technical Article MS-2443

Declaration of Conformity.

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

Telephone- and leased line modem for industrial applications TD-36

Dual Chamber Temporary External Pacemaker

STRATO LED Drivers 70W, Single output

15 Series - Electronic step relay and dimmer. Features SERIE

Declaration of Conformity.

30 In Compliance October

Design Guide for the Control of ESD in the esata Interface

Declaration of Conformity.

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT S-E

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Rack mounted telephone- and leased line modem for industrial applications

Design and Certification of ASH Radio Systems for Japan

NMI M 6-2 Electricity Meters. Part 2: Test Report Format

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Rules for Classification and Construction Additional Rules and Guidelines

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

Foxboro Evo Process Automation System

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

The impact of the New EMC Directive 2004/108/EC

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Application Note AN001

Data Communications Competence Center

38 Series - Relay interface modules A

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

Current Probes, More Useful Than You Think

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems

TECHNICAL TBR 14 BASIS for April 1994 REGULATION

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

Energy Management Energy Meter Type EM23 DIN

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RX-AM4SF Receiver. Pin-out. Connections

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

80 Series - Modular timers 16 A. Features

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

38 Series - Relay interface modules A

80 Series - Modular timers 16 A. Features

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

7. Technical Notes Table of Contents

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

Electromagnetic Compatibility Considerations for Switching Power Supplies

Radiated Emission and Susceptibility

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

White Paper: Electrical Ground Rules

MasterINTERFACE 39 Series - Relay interface modules

PE10G2T Dual Port Fiber 10 Gigabit Ethernet TOE PCI Express Server Adapter Broadcom based

Indoor / Outdoor Antenna

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

EMC for test engineers by. Laplace Instruments Ltd. An introduction to the world of EMC compliance testing for engineers new to the topic.

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

Transcription:

European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2610 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic Investigations, LLC 20811 NW Cornell Road, Suite 600, Hillsboro, Oregon 97124, USA Tele (503) 466-1160 Fax (503) 466-1170 support@emicomply.com

Summary Information Test Item: 2610 Modular Measurement and Control System Serial Number: EU EMC Tests in accordance with EU Council Directive 89/336/EEC Emissions Tests per EN 61326 Test Standard for measurement, control and laboratory equipment: Result Standard Description Port Comments Pass EN55011 Class A Radiated Emissions Enclosure Pass EN55011 Class A Conducted Emissions AC Mains Pass EN61000-3-2 Powerline Harmonics AC Mains Pass EN61000-3-3 Powerline Voltage Fluctuation & Flicker AC Mains Immunity Tests per EN 61326 (Industrial Levels) Result Standard Description Port Comments Pass EN61000-4-2 Electrostatic Discharge Enclosure Tested up to 8 kv air Immunity discharge and 4 kv contact discharge Pass EN61000-4-3 RF Electromagnetic Field Enclosure 10 V/M, 80 to 1000 Immunity MHz Pass EN61000-4-4 Electrical Fast Transient/Burst AC Leads 2 kv peak (EFT) Immunity Pass EN61000-4-4 Electrical Fast Transient/Burst (EFT) Immunity I/O Leads 1000 V peak Pass EN61000-4-5 Electrical Slow Transient (Surge) Immunity AC Leads 1 kv peak - differential mode 2 kv peak - common mode Pass EN61000-4-6 RF Conducted Immunity AC Leads 10 V RMS, 150 khz to 80 MHz Pass EN61000-4-6 RF Conducted Immunity AC Leads 10 V RMS, 150 khz to 80 MHz Pass EN61000-4-11 Voltage Interruption Immunity AC Leads 0.5 cycle, 100% dropout

I,, representative for Sensoray verify that the product tested is representative of units to be sold. (signature) 2

EN 61326 Emissions 3

EN61326 Emissions Test Report 2610 Modular Measurement and Control System Sensoray March 31, 2006 Tests Conducted by: ElectroMagnetic Investigations, LLC 20811 NW Cornell Road, Suite 600, Hillsboro, Oregon 97124, USA Tele (503) 466-1160 Fax (503) 466-1170 support@emicomply.com

Table of Contents EN55011 Class A Test Summary Page 3 EN55011 Class A test Setup Page 4 EN55011 Class A Test Results Page 5 Test Data Page 5 Test Photographs Page 6 2

Summary Information Test Items: Serial Number: Requested By: Tested By: 2610 Modular Measurement and Control System Caleb Streur Sensoray 7313 SW Tech Center Dr. Tigard, OR 97223 503.684.8005 Telephone Derick Skouby Ryan Benitez Test Date(s): March 31, 2006 Tests Performed: Radiated and conducted electromagnetic interference measurements as per EN55011 Class A. Test Locations: ElectoMagnetic Investigations, LLC, Hillsboro, Oregon Purpose: The purpose of the testing is to determine if the 2610 Modular Measurement and Control System is compliant to electromagnetic emission limits as specified by EN61326 product family standard for measurement, control and laboratory equipment to support compliance to the European Union EMC Directive 89/336/EEC. Summary of Results: EN55011 Class A: Radiated Emissions:. Emissions are within specification limits. Least Margin:.....10.4 db at 170.2 MHz. Conducted Emissions: :. Emissions are within specification limits. Least Margin:.....6.9 db at 27.9 MHz. EN61000-3-2/3: Powerline Harmonic Emissions:. Emissions are within specification limits. 3

Test Method The 2610 Modular Measurement and Control System was tested in accordance with EN61326 standard. Radiated levels were measured at three meters distance in both horizontal and vertical antenna polarizations. The radiated emission measurements were maximized by rotating the device under test 360 degrees and varying the height of the receiving antenna from 1 to 4 meters. Test Set-Up Control PC Ethernet Cable Power Cable 2600 EUT Figure 1 The 2610 (EUT) is connected to the Control PC which is set up outside of the test chamber. Detector Function: Peak/Quasi-peak. Measurement Bandwidths: 150 khz to 30 MHZ: 9 khz Peak/ 9 khz Quasi-Peak 30 MHz to 1000 MHZ: 120 khz Peak/120 khz Quasi-Peak 4

Test Results: The 2610 Modular Measurement and Control System unit tested was verified to be compliant with EN55011 class A radiated and conducted emission limits. The 2610 Modular Measurement and Control System unit tested was verified to be compliant with EN61000-3-2/3 powerline harmonics and powerline fluctuation/flicker specifications. Test Data: I. Radiated Emissions (3-Meter Specifications) Frequency (MHz) Total Level (dbuv/m) EN55011 Class A Limit (dbuv/m) Margin (db) 71.7 36 50.4 14.4 72.3 37.3 50.4 13.1 76.9 34.3 50.4 16.1 78.8 38.8 50.4 11.6 153.8 38.8 50.4 11.6 170.2 40 50.4 10.4 II. Conducted Emissions Frequency (MHz) Total Level (dbuv/m) EN55011 Class A Limit (dbuv/m) Margin (db) 1.315 47.6 60 12.4 1.316 48 60 12 25.95 50.3 60 9.7 26.93 49 60 11 27.42 48.1 60 11.9 27.9 53.1 60 6.9 5

Test Setup Photographs: Radiated Emissions 6

Conducted Emissions 7

Powerline Harmonics/Powerline Fluctuations 8

Additional Test Data 9

EN 61326 Immunity

EN61326 Immunity Test Report 2610 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic Investigations, LLC 20811 NW Cornell Road, Suite 600, Hillsboro, Oregon 97124, USA Tele (503) 466-1160 Fax (503) 466-1170 support@emicomply.com

Table of Contents Test Performed Page 3 Summary of Results Page 4 Performance Criteria Page 7 Test Setup Page 6 Test Results Page 7 Test Photographs Page 9 ElectroMagnetic Investigations, LLC 2

Summary Information Test Items: Serial Number: Requested By: Tested By: 2610 Modular Measurement and Control System Caleb Streur Sensoray 7313 SW Tech Center Dr. Tigard, OR 97223 503.684.8005 Telephone Derick Skouby Ryan Benitez Test Date(s): March 31, 2006 April 4, 2006 Tests Performed: Air, Contact and Indirect Electrostatic Discharge Immunity per basic standard EN61000-4-2 in accordance with EN61326 product family standard requirements. RF Electromagnetic Field Immunity per basic standard EN61000-4-3 in accordance with EN61326 product family standard requirements. Electrical Fast Transient Immunity per basic standard EN61000-4-4 in accordance with EN61326 product family standard requirements. Electrical Slow Transient Immunity per basic standard EN61000-4-5 in accordance with EN61326 product family standard requirements. RF Conducted Immunity per basic standard EN61000-4-6 in accordance with EN61326 product family standard requirements. RF Powerline Interruption Immunity per basic standard EN61000-4-11 in accordance with EN61326 product family standard requirements. ElectroMagnetic Investigations, LLC 3

Test Location: ElectroMagnetic Investigations, LLC, Hillsboro, Oregon Purpose The purpose of the testing is to determine if the 2610 Modular Measurement and Control System is compliant to immunity specifications as per EN61326 product family standard for measurement, control and laboratory equipment to support compliance to the European Union EMC Directive 89/336/EEC. Heavy industrial environmental levels were tested. Summary of Results EN61000-4-2 RF Electrostatic Discharge Immunity Pass (performance criteria B) The 2610 Modular Measurement and Control System complies with performance criteria B as specified by the manufacturer after subjected to electrostatic discharge. No degradation of performance was observed after application of electrostatic discharge. EN61000-4-3 RF Fields Immunity Pass (performance criteria A) The 2610 Modular Measurement and Control System operated within the performance criteria while subjected to an electromagnetic field of 10 V/m with 80% 1 khz amplitude modulation in the frequency range from 80 MHz to 1000 MHz. No degradation of performance was observed beyond performance criteria. EN61000-4-5 Electrical Fast Transient Immunity Pass (performance criteria B) The 2610 Modular Measurement and Control System operated within the performance criteria after subjected to electrical slow transient to the AC mains. No degradation of performance was observed. EN61000-4-5 Electrical Slow Transient Immunity Pass (performance criteria B) The 2610 Modular Measurement and Control System operated within the performance criteria after subjected to electrical slow transient to the AC mains. No degradation of performance was observed. EN61000-4-6 RF Conducted Immunity Pass (performance criteria A) The 2610 Modular Measurement and Control System operated within the performance criteria when subjected to an RF conducted signals injected onto the AC mains. No degradation of performance was observed. EN61000-4-11 Powerline Voltage Interruption Pass (performance criteria B) ElectroMagnetic Investigations, LLC 4

The 2610 Modular Measurement and Control System operated within the performance criteria after subjected to powerline interruptions to the AC mains. No degradation of performance was observed. Description of product: The 2610 is a modular measurement and control system designed for applications such as machine control, industrial process control, building automation and remote data acquisition. It uses Ethernet to connect a LAN to I/O measurement and control points. Test Methods EN61000-4-2 Electrostatic Discharge Immunity The 2610 Modular Measurement and Control System was tested in accordance with EN61000-4- 2 per the methods and limits specified in EN61326. The 2610 Modular Measurement and Control System, configured as described in Test Setup, was placed on an insulating support resting on a conductive table 0.8 meters in height. The 2610 Modular Measurement and Control System was subjected to electrostatic discharges from an Electrostatic Discharge Simulator. Contact discharges were applied to accessible metal areas of the 2610 Modular Measurement and Control System, to horizontal coupling plan and to vertical coupling plane placed 10 cm away from each side of the 2610 Modular Measurement and Control System. Air discharges were applied to non-metallic areas. EN61000-4-3 RF Fields Immunity The 2610 Modular Measurement and Control System was tested in accordance with EN61000-4- 3 per the methods and limits specified in EN61326. The 2610 Modular Measurement and Control System, configured as described in Test Setup, was placed on a non-conductive table 1.0 meter in height inside a shielded enclosure. Electromagnetic fields were generated by antennas placed 3.0 meters in front of the 2610 Modular Measurement and Control System. While the 2610 Modular Measurement and Control System was monitored for degradation of performance, the electromagnetic field was maintained at 10 V/m with 80% 1 khz amplitude modulation while scanning the frequency range from 80 MHz to 1000 MHz. EN61000-4-4 Electrical Fast Transient Immunity ElectroMagnetic Investigations, LLC 5

The 2610 Modular Measurement and Control System was tested in accordance with EN61000-4- 4 per the methods and limits specified in EN61326. The 2610 Modular Measurement and Control System configured as described in Test Setup, was placed 10 cm above a conductive surface. The 2610 Modular Measurement and Control System was subjected to electrical transients/bursts (EFT/B) injected capacitively through a Mains Coupler/Decoupler onto each of the line, neutral and earth conductors of the EUT power input. The EFT/B consists of 5 ns rise time, 50 ns duration pulses with a repetition frequency of 5 khz. The pulses are delivered in 15 ms bursts with a burst repetition period of 300mS. Both positive and negative pulses are applied at 1 kv and 2.0 kv peak to each of the conductors described above for a period of at least 1 minute. The burst transient was injected onto the I/O line at a level of ±500 V and ±1000 V by a capacitive clamp. EN61000-4-5 Electrical Slow Transient Immunity The 2610 Modular Measurement and Control System configured as described in Test Setup, was placed on a non-conductive table 0.8 meter in height. The 2610 Modular Measurement and Control System was subjected to electrical power line surge transients injected capacitively through a Mains Coupler/Decoupler onto the conductors of the EUT power input. The surges have an open circuit voltage waveform with a rise time of 1.2 µs and duration of 50 µs, and a short circuit waveform with a rise time of 8 µs and duration of 20 µs.. Surges are applied to each of the line and neutral conductors with respect to earth ground (common mode) at 0.5 kv, 1 kv and 2 kv. Surges are also applied differentially across the line and neutral conductors at 0.5 kv and 1 kv. Both 5 positive and 5 negative surges are applied at 0, 90, 180, and 270 phase angles for each voltage and configuration. EN61000-4-6 RF Conducted Immunity The 2610 Modular Measurement and Control System configured as described in Test Setup, was placed.1 meters above a conductive table. The 2610 Modular Measurement and Control System AC mains lines and I/O were subjected to 10 Vrms RF signals swept from 150 khz to 80 MHz with 80% amplitude modulation with a 1 khz sine wave. EN61000-4-11 RF Voltage Interruption The 2610 Modular Measurement and Control System configured as described in Test Setup, was placed on a non-conductive table 0.80 meter in height. The 2610 Modular Measurement and Control System AC mains lines were subjected to 100% interruption of the powerline voltage for a period of 0.5 cycles. ElectroMagnetic Investigations, LLC 6

Performance Criteria A No degradation of performance during application of EMC phenomena. (EN61000-4-3, EN61000-4-6). B - No degradation of performance after application of EMC phenomena. (EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-11). Test Set-Up Control PC Ethernet Cable Power Cable 2600 EUT Figure 1 The 2610 (EUT) is connected to the Control PC which is set up outside of the test chamber. Test Results EN61000-4-2 per EN61326 product family requirements (Electrostatic Discharge) No degradation of operation was observed after the test. ElectroMagnetic Investigations, LLC 7

EN61000-4-3 per EN61326 product family requirements (RF Fields) No degradation of operation was observed during or after the test. EN61000-4-4 per EN61326 product family requirements (EFT/B) No degradation of operation was observed during or after the test. EN61000-4-5 per EN61326 product family requirements (Surge) No degradation of operation was observed during or after the test. EN61000-4-6 per EN61326 product family requirements (RF Conducted) No degradation of operation was observed during or after the test. EN61000-4-11 per EN61326 product family requirements (Voltage Interruption) No degradation of operation was observed during or after the test. ElectroMagnetic Investigations, LLC 8

Test Setup Photographs: Electrostatic Discharge Immunity ElectroMagnetic Investigations, LLC 9

RF Radiated Immunity ElectroMagnetic Investigations, LLC 10

Powerline Immunity Electrical Fast & Slow Transient & Dropouts ElectroMagnetic Investigations, LLC 11

RF Conducted Immunity ElectroMagnetic Investigations, LLC 12

EN61326 EMC Test Plan ElectroMagnetic Investigations, LLC 13

Sensoray EMC Test Plan Product Model Number: 2600 Series Products included in this product group: 2601, 2608, 2610, 2620, 2650, 2652 Description of product: The 2600 is a modular measurement and control system designed for applications such as machine control, industrial process control, building automation and remote data acquisition. It uses Ethernet to connect a LAN to I/O measurement and control points. Revision History Rev Date Reason for Amendment description of change 1.0 3/22/2006 First Issue Author: Caleb Streur, Applications Engineer Introduction This document contains the proposed EMC test procedure and method of evaluation for the product described above. Testing will be per EN61326 electromagnetic compatibility product family test standard for measurement, control and laboratory equipment. Test Configurations, Procedures and Performance Criteria Non-Industrial Class In the following tests, we are using the non-industrial class specifications. Test & Measurement Type This EUT is considered to be a Test & Measurement type of equipment, and follows the specifications for this type of device. 1) Electrostatic Discharge (ESD) Immunity The Test Setup is described in the Appendix in Figure 1, and is further described as follows: The 2600 (EUT) is connected to a PC via an Ethernet cable. All three devices are on the ESD Test Table and insulated from the surface. The ESD Test Table has a conductive table top and is connected to Page 1

Sensoray EMC Test Plan Earth ground via a test standard specified resistor. The ESD Simulator is connected to the surface of the ESD table. We will note any reaction by the unit to the conducted & radiated energy by observing the display of the control PC. Page 2

Sensoray EMC Test Plan Performance Criteria - ESD Performance Criteria B, as described in the Appendix of this Test Plan, will be used for this test. The ESD Immunity test requirements are described by the EN61000-4-2 specification. The test consists of simulated ESD events by contact & air discharge to the EUT case. Discharges within 10cm of the EUT will also be performed on the horizontal & vertical planes of the ESD Test Table. Discharges of positive & negative voltages of 2kV and 4kV are required by the standard (non-industrial class). To provide a level of margin, we will also test the EUT at positive and negative 6kV and 8kV levels. Any degradation of performance at these elevated levels will not be considered a failure, but will be noted in the Test Results. We do not expect any significant change in performance. Acceptable performance will be that the measured energy may only change during the ESD event. For this test the measured energy may exceed the probe specifications during the ESD event. The EUT will not change states and will not require user intervention to resume making accurate measurements after the ESD event. 2) Radiated Immunity We will use the Test Setup as described in the Appendix of this Test Plan as in Figure 1. This setup is considered worst case for this test. We will note any reaction by the EUT to the RF field by observing the display of the control PC. Performance Criteria Radiated Immunity Page 3

Sensoray EMC Test Plan Performance Criteria A, as described in the Appendix of this Test Plan, will be used for this test. The Radiated Immunity test requirements are defined by the EN61000-4-3 specification. The test consists of an RF signal from 80 to 1,000MHz modulated 80% AM @ 1 khz sine wave. The signal strength at the EUT shall 3V/m at horizontal and vertical polarizations. We do not expect any significant change in performance. Acceptable performance will be a reading on the EUT that is within 5% of the expected result while the system is exposed to the RF field. 3) Conducted Immunity We will use the Test Setup as described in the Appendix of this Test plan as in Figure 1. This setup is considered to represent a typical user setup. Performance Criteria Conducted Immunity Performance Criteria B, as described in the Appendix of this Test Plan, will be used for this test. The Conducted Immunity test requirements are defined by the EN61000-4-6 specification. The test consists of the injection of a 10 Vrms 80% AM sine from 150 khz to 80MHz signal. We do not expect any significant change in performance. Acceptable performance will be a reading on the EUT that is within 5% of the expected result while the system is exposed to the RF field. 4) Electrical Fast Transient Immunity (Burst) We will use the Test Setup as described in the Appendix of this Test plan as in Figure 1. This setup is considered to represent a typical user setup. Performance Criteria EFT Immunity (Burst) Performance Criteria B, as described in the Appendix of this Test Plan, will be used for this test. The EFT Immunity test requirements are defined by the EN61000-4-4 specification. The test consists of the injection of 1.0kV onto the AC line. Page 4

Sensoray EMC Test Plan We do not expect any significant change in performance. Acceptable performance will be a reading on the EUT that is within 5% of the expected result after the system is exposed to the RF energy. 5) Electrical Slow Transient Immunity (Surge) We will use the Test Setup as described in the Appendix of this Test plan as in Figure 1. This setup is considered to represent a typical user setup. Performance Criteria Electrical Slow Transient Immunity (Surge) Performance Criteria B, as described in the Appendix of this Test Plan, will be used for this test. The Electrical Slow Transient Immunity test requirements are defined by the EN61000-4-5 specification. The test consists of the injection of 500V Line to Line & 1kV Line to Earth onto the AC line. We do not expect any significant change in performance. Acceptable performance will be a reading on the EUT that is within 5% of the expected result after the system is exposed to the RF energy. 6) Voltage Interrupt Immunity We will use the Test Setup as described in the Appendix of this Test plan as in Figure 1. This setup is considered to represent a typical user setup. Performance Criteria Voltage Interrupt Immunity Performance Criteria B, as described in the Appendix of this Test Plan, will be used for this test. The Voltage Interrupt Immunity test requirements are defined by the EN61000-4-11 specification. The test consists of removing power for one complete cycle (50Hz). We do not expect any significant change in performance. Acceptable performance will be a reading on the EUT that is within 5% of the expected result after the system is exposed to the Voltage Interrupt. 7) Radiated Emissions We will use the Test Setup as described in the Appendix of this Test plan as in Figure 1. This setup is considered to represent a typical user setup. We will observe the emissions radiated from this EUT with a recording spectrum analyzer and note in the Test Results, the levels of emissions and their frequency. Performance Criteria Radiated Emissions Page 5

Sensoray EMC Test Plan The Radiated Emissions test limits are defined by the EN61326 Class A specification. We will be measuring RF Emissions from the EUT at 3 meters. 8) Conducted Emissions We will use the Test Setup as described in the Appendix of this Test plan as in Figure 1. This setup is considered to represent a typical user setup. We will observe the emissions radiated from this EUT with a recording spectrum analyzer and note in the Test Results, the levels of emissions and their frequencies. Performance Criteria Conducted Emissions The Conducted Emissions test limits are defined by the EN61326 Class A specification. End of Test Configurations, Procedures and Performance Criteria Page 6

Sensoray EMC Test Plan Appendix Test Setups Control PC Ethernet Cable Power Cable 2600 EUT Figure 1 The 2600 (EUT) is connected to the Control PC which is set up outside of the test chamber. The EUT is monitored for any changes during the EMI events. Page 7

Sensoray EMC Test Plan Performance Criteria A Definition The EUT (Equipment Under Test) may react to the EMI energy but may not change states or require user intervention to continue making accurate measurements after the EMI event. No degradation of the product tolerances or specifications is allowed. The output measurement of the EUT shall be within 5% of the expected result, while being exposed to the EMI energy, and return to normal upon removal of the EMI energy. Performance Criteria B Definition The EUT may react to the EMI energy during the event (ESD), but may not change states or require user intervention to continue making accurate measurements after the EMI event. If the output measurement of the EUT is beyond 5% of the expected results during a continuous EMI test (i.e. Radiated or Conducted RF Immunity), this information is to be declared on the product or in the User Manual for the product. Performance Criteria C Definition The EUT temporarily stops functioning and requires user intervention to bring it back to a normal operating condition (during or after the EMI energy exposure). Performance Criteria D Definition The EUT permanently stops functioning, or is permanently damaged by the EMI energy. Degradation or loss of function which is not recoverable due to damage to equipment, components, or the software. Any EUT that falls into this category is not CE compliant. Page 8