Dual Agent Unit w/ Foam Tank & Firewater Monitor DAHR 04

Similar documents
HELI-DECKS & HELI-PORTS

Fire Extinguishers Water Extinguishers

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Vacuum Tube Solar Water heater Non-pressure. User manual

SUPERYACHT SPARES. Nozzles and portable monitors. / info@superyachtspares.com /

Dry Chemical Systems TWIN AGENT CAPABILITY

FOAM CHAMBER MODEL - FC

Power consumption (kw)

FIRE,FIREFIGHTING & FIREFIGHTING EQUIPMENT

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

PETROLEUM STORAGE TANK FIRE PROTECTION SECTION INDEX

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Product catalogue, pipe and sewer cleaning systems

Operators manual Basic water heater

Itho Products for Hot and Boiling water. product-

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

CO 2. fire extinguishing systems

San josé OWNER S MANUAL

Industrial Electric Monitors. Industrial

API Flanged Safety Relief Valves Series 526 CATALOG

FOAM STATIONS SECTION INDEX

IVECO CHASSIS DAILY 70C21D (4x2)

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Draining and filling cooling system

Automatic Fire Fighting Monitors

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

System Accessories Pricing. Page 0 Effective 7/02

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Fixed or Semi-Fixed Fire Protection Systems for Storage Tanks

swimming pool accessories

FLASH TANK ECONOMIZER PRODUCT GUIDE

Foam Systems Inductors & Proportioners

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS. Argotec Liquid Argon Gas Extinguishing Technology (LAR)

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

EXTINGUISHER. The purpose of this module is to sensitize firefighters on the subject of extinguishers.

Morrison Bros. Co. General Product Specifications

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

OPTIMASS 6000 Technical Datasheet

ETC -SV. Class 0 oil-free compressed air through catalysis

VAD. Variable Area Desuperheaters

Cooking at the Speed of light!

orlando OWNER S MANUAL

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

TABLE OF CONTENT

PARTS MANUAL EH12-2 ENGINE. Model. PUB-EP5713 Rev. 7/99

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Cooling system components, removing and installing

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Air Eliminators and Combination Air Eliminators Strainers

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

Electronic Flow Switches

T E C H N I C A L S P E C I F I C A T I O N. SUPER FUEL & LUB TRUCK Fuel tanker and lubrication truck (6x6)

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

A practical guide to restrictive flow orifices

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

FILLING AND PURGING THE SYSTEM

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Thermostatic bar showers. Troubleshooting and maintenance

Hydraulic Control Solutions

air water oil antifreeze grease diesel fuel kerosene oxygen-acetylene lpg-methane electricity Hose & cable reel

Nozzle Check Valves. NOREVA nozzle check valves are used

V47 Series Temperature Actuated Modulating Water Valves

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam.

BRANCH SOLUTION. Fire protection for wind turbines. Safe for certain

FIRE-FIGHTING DESIGN BRIEF REPORT

NOHA NORWAY AS. fire fighting equipment. industry, oil and gas

CATHODIC PROTECTION SYSTEM DESIGN

Firefighter Review. Instructor Guide

SOLAR HOT WATER SOLUTIONS stainless steel roof systems

BLASTING SYSTEMS. Turbine blasting systems. Air blasting systems. Automatic Painting plants

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

OPTIMASS 1400 Technical Datasheet

solarplus solar systems general features

CHEMICAL CLEANING UNIT Product number:

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

Vehicle Fire Suppression Systems COPY ONLY

WD600 STEAM TRAPS. Thermodynamic Steam Trap

Product catalogue, tank cleaning systems

Equipment Information

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

Delta Fire manufacture and supply a comprehensive range of Marine Fire Fighting Equipment.

PBX Series Quick Fit Connector Bimetallic Steam Traps

Fisher 377 Trip Valve

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

All You Ever Wanted to Know About Fire Extinguishers...

In-Line Electronic Flow Switches

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

DESIGN STANDARDS SECTION

Transcription:

DAHR-04 DUAL AGENT UNIT WITH MONITOR AND LOCAL INTEGRATED FOAM TANK Standard Material: Cabinet: SST AISI 316, painted externally Dry chemical tank: SST AISI 316 Foam Tank: SST AISI 316 Firewater Piping: Titanium gr. 2 Firewater Valves: Titanium gr. 2 Foam piping & valves: SST AISI 316 Dry chemical piping& valves: SST AISI 316 Hose reel : SST AISI 316 Nozzle: Bronze Hose: Codan 5300 (1 ) and 5400 (1¼ ) Hand Crank: SST AISI 316 Foam Inductor: Titanium (1% or 3% per project requirements) Foam pipe and valves: SST AISI 316 Oscillating monitor: Bronze

Installation: Mount: Bolted to deck Operation: Activate dry chemical unit by opening N2 release valve which is pressurizing dry chemical tank. Open water valve and foam valve. When dry chemical tank is pressurized (after approx. 10 seconds) open dry chemical valve. Pull out hose to required length, and operate the dry chemical handle and water/foam handle on nozzle carefully as required. The dry chemical gives a quick knock down of the fire, and the water/afff foam mix provides a sealing surface to prevent re-ignition. Be aware of the nozzle reaction forces! The monitor can be activated by an electric push button which will cause the monitor release valve to open. The monitor will start to oscillate automatically over a predetermined sector Options: Water Piping & Valves: Aluminium Bronze / Cunifer 90/10 Super Duplex Stainless Steel Pressure Indicators: Cabinet: Project Preference Insulation Heater (Zone 1 Certified) Max working pressure powder tank: Working pressure hose reel water part: Test pressure powder tank: Test Pressure Hose reel: 18 barg 20 Bar 33 barg 30 barg

Table 1: DAHR 04 Dimensions and Weight Description DA Unit w/atmospheric AFFF tank Type DAHR- 04 Hose size & length 1 x 30 m (powder) 1 ¼ x 30 m (water/foam) Cabinet Length (mm) Cabinet Height (mm) Cabinet Depth (mm) Dry Weight (kg) * 2350 1560 1150 790 * Weight includes charged N2 cylinders, but not powder, AFFF or seawater.

System logic drawing

Dual Agent Units are manually operated units, discharging dry chemical powder and water/foam, intending to be used by trained firefighting personnel. These Units are extremely efficient units for protection of areas with a risk of hydrocarbons or alcohol fires, such as helicopter decks and process areas. The Dual Agent hose reels are supplied with two individual hoses, where one hose is flowing dry chemical and the other is flowing water/foam. The hoses are connected to a common nozzle, giving individual control of the two agents. Dual Agent Units are rapidly activated, and they are simple to use. The dry chemical powder gives a rapid knockdown of large scale fires, while water/foam gives cooling of hot surfaces and sealing of liquid pool fires. The Dual Agent Units must be installed in the vicinity of the area they are to protect. Technical Description FPE has developed a range of Dual Agent Units, installed in heated and insulated stainless steel cabinets. The standard FPE Dual Agent Unit consists of the following main components: Cabinet Hose reel Dual agent nozzle Dry chemical system, with N2 expellant Foam system Firewater inlet piping The dual agent unit provides two different fire extinguishing agents: The hose reel is equipped with two hoses, where one flows a mixture of water and foam, and the other flows dry chemical powder. The hose reel is equipped with a dual agent nozzle that has individual open/shut valves for the two agents, and with a twist-action selection of jet or fog on the water/foam side.

DAHR 04 Foam System The selection of type of foam, and the mixing ratio of foam/water, is based on the standard on the platform. This Unit is made to connect to the platform firewater ring main system via a standard flange connection. The unit has a 32 mm (1 ¼ inch) hose for supply of foam/water as the standard. This unit, has a local foam tank which is feeding both the oscillating monitor, and the dual agent hose reel unit with foam. The dual agent hose reel is fed by a pick-up foam inductor which gives the correct flow and mixing ratio. The oscillating monitor has a nozzle with a built in venturi to give the correct foam mixing ratio. The monitor is fitted with its own Inbal deluge valve for system release. This unit is intended for use on helidecks. Dry Chemical System The dry chemical system consists of a storage tank for powder and an N2 expellant gas cylinder. A manual release valve is installed on the N2 cylinder valve. The tank is charged with 250 kg of powder. When the manual release valve is operated, N2 will pressurize the dry chemical system quickly, giving an initial shock of the dry chemical and functioning as an expellant during discharge. The tank is equipped with a pressure safety valve, a fill cap and a pressure indicator. The dry chemical inlet to the hose reel is equipped with an isolation ball valve, designed for use with dry powder. The dry chemical system on all models is identical, and is designed to provide a flow of 2,5 kg powder per second, effective for approx. 100 seconds. The dry chemical hose on the hose reel is 25 mm (1 inch). Flow Capacity The flow for water/foam is given in the table below: Model DAHR04 Inlet pressure, (Barg) Flow 6 198 8 229 10 255 Flows are given in Liter per Minute (Lpm)