FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside.

Similar documents
FLUXUS Energy. Manage energy effectively using non-invasive measuring technology. Heat usage, chilled flows and compressed air flow rate

COMBIMASS. Technical Data COMBIMASS eco-bio +

PORTABLE FLOW METER KITS TDS-100H

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

IFC 070 Technical Datasheet

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

SONAPHONE. The New Device Class for Preventive Maintenance

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Affordable wireless monitoring without compromise

Figure 1 Flexim F601 parts 1) Control console 2) Ultrasonic transducers 3) Magnetic transducer mounting rails 4) RTD temperature probes (PT100)

Process Alarm Solutions

How To Use A Flowmeter

CALDON LEFM 380Ci Gas Ultrasonic Flow Meter. Integrating experience, proven technology and innovation

O C M III. Open Channel Flow Monitor

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Sensing & Inspection Technologies. Applications. Features

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Energy and Flow Measurement for Hydronic Systems

How To Use An Irius Pid Detector

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Dräger Alcotest 9510 Evidential Alcohol Measuring Device

Take total control of your HVAC system with cost-saving flow and thermal energy meters

Quick Connect. quick - simple - efficient.

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

DigitalFlow GF868 Panametrics Ultrasonic Flare Gas Mass Flowmeter. GE Sensing. Features. Applications

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

Highly efficient flue gas analyzer

Instruction Manual. T3111 T3111L T3111P T3111Ex

Distributed Temperature Sensing - DTS

ENAiKOON ultrasonic fuel-level sensor

Smile. The All-In-One Heating Controller

Multifunction HVAC and IAQ Meter

OPTIMASS 6000 Technical Datasheet

DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.

Battery Powered Digital Mass Flow Meters for Gases

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

Electronic Control Devices The European Product Catalogue 2007

Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed.

Wahl C50 Calibrator FEATURES

Portable digital microprocessor thermometers with interchangeable probes

N4385A / N4386A Distributed Temperature System (DTS)

Designed for multi-injector endurance testing, the

Digital inductive conductivity transmitter

AMTRON E-30 Compact heat and cooling meter

FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

ROTEX gas hybrid heat pump. A strong team.

Typical Aluminum GFM Mass Flow Meter

KNC Model 3666 Automatic Pressure Calibration System

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

Everything you need for protection scheme testing

globe reactions made easy Process perfection

Measurement Solutions for Refrigeration Technology.

Electromagnetic Flow Meter

Key Features. Product Overview. Threaded Joint Rate Simulator

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

Thermal Mass Flow Meters and Controllers for Gases

Outages Happen 24/7 So Should Monitoring / SAFEGUARD YOUR HIGH VOLTAGE ASSETS WITH VAISALA ONLINE MONITORING

Reliability Accuracy Performance

DETERMINATION OF THE HEAT STORAGE CAPACITY OF PCM AND PCM-OBJECTS AS A FUNCTION OF TEMPERATURE. E. Günther, S. Hiebler, H. Mehling

FACTORY AUTOMATION EXPERTISE AND SERVICE OPEN DOORS RADAR SENSORS FROM PEPPERL+FUCHS

How To Use A Corona Mdi 110

Agilent 4338B Milliohm Meter

Impact Testing Systems

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Agilent 4339B/4349B High Resistance Meters

HyPM Fuel Cell Power Modules

Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice

Measurement & Analytics. VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy

Battery Powered Thermal Mass Flow Meters for Gases

Tobii X2 Eye Trackers

4-Channel Thermometer / Datalogger

Energy Management Solutions

The ebike Rechargeable Battery Guide

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

ULTRASONIC THICKNESS GAUGE TT100/110/120/130

The Unique Accelabar Flow Meter

Battery Powered Thermal Mass Flow Meters for Gases

Engineered Solutions

Power consumption (kw)

100DHP TM CCI DRAG Control Valve For High Pressure Turbine Bypass

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

How To Power A Power Plant With Waste Heat

T0118 T2118 T3118. Instruction Manual

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

RITTER Multiple Sonic Nozzle Calibration System

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

CARINAnav SMART LASER CONTROL

Clinic Washer-Disinfectors. Washer-Disinfector Line

Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities

4000 Optima. Bondtesting Optimized.

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

IceSpy Mini System. Makes light work of small to medium wireless environmental monitoring FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS

OPTIMASS 1400 Technical Datasheet

Transcription:

www.flexim.com Reliable flow measurement in less than 5 minutes. Wide application range. With long life marathon battery. Portable, quick and reliable FLUXUS F601 Clamp-on ultrasonic flow meter Accurate Flexible Quick Sturdy Ergonomic Measure from outside what's flowing inside

FLUXUS F601 Mobile flow measurement without compromise The benefits are evident... reliable measurement even in difficult conditions thanks to the new HybridTrek mode high accuracy thanks to dual μp technology with digital signal processing and to powerful correction algorithms maximum flexibility - broad range of applications quick measurement; reliable results in less than 5 minutes sturdy build for use in rough environments ergonomic design; optimized for daily use on-site long-life marathon battery; comprehensive energy management with display of remaining capacity 2

The flexible meter FLUXUS F601 measures the flow of liquids using FLEXIM's proven transit-time correlation technique. Special ultrasonic transducers are simply clamped onto the outside of the pipe and never come in direct contact with the liquid. No cutting into the pipe or process interruption is required for installation. FLUXUS F601 offers maximum flexibility: for virtually any pipe material and any fluid, regardless of the conductivity independent of the pressure level wide application range: two pairs of transducer are sufficient to cover the most common pipe diameters in industrial applications the wide range of transducers makes flow measurement possible from DN 6 to DN 6500 and from -40 C to + 400 C. It also includes transducers for explosion hazard areas (ATEX and FM). FLUXUS F601 is more than just an upgrade to the FLUXUS ADM 6725, an instrument which has proven itself in thousands of applications. The numerous improvements implemented were derived from years of application practice. Even sturdier than its predecessor, F601 is ideally suited to the rough conditions in industrial environments. Its ergonomic design offers simple handling and maximum ease of use. FLUXUS F601 measures even longer, with even greater accuracy. The new battery allows for up to 14 hours of autonomous measurement. New algorithms such as the correction of pipe wall echoes and transducer positioning errors ensure reliable and accurate measurement even in difficult conditions. 3

Fit for the purpose Reliable measurement in less than 5 minutes Selection of the measuring point Measurement of the wall thickness Connection of the transducers Select a suitable measuring point. Simply select the pipe material from the list and measure the wall Automatic transducer detection and calibration in the device offer thickness with the ultrasonic probe. maximum safety and ease of use. 4

Input of the parameters Select pipe material and fluid from Mounting of the transducers Starting of the measurement the integrated list; input the pipe Apply coupling agent; mount the Immediately after the ENTER button dimensions as requested. transducers on the side of the pipe; set and fix the displayed transducer distance. has been pressed, the measured values appear in the display. 5

Made for users by users The features at a glance Practical housing compact and easy to handle designed for industrial use equally suitable for left and righthanded persons multi-functional carrying and degree of protection IP65 set-up handle handles also protect the edges low weight water and dust-tight; resistant QuickFix pipe mounting system for against oil, many liquids, and dirt fast mounting of the transmitter in positions where a free hand for holding is unavailable (e.g. for measure- Cutting-edge features ments in great heights) integrated pipe wall thickness measurement automatic transducer detection and calibration data offer maximum safety and ease of use portable energy measurement (option for detecting energy flows in a system; ideal for energy audits, optimization of heating systems, energy consumption measurement, etc.) high operational safety in case of fluids with high percentage of gas or solids thanks to the HybridTrek measuring mode 6

Excellent battery management precise display of remaining capacity more than 14 hours of measurement with lithium-ion batteries no self-discharge, no memory effect Improved performance extensive fluid and material database Sturdy case extremely sturdy case; may even proven FLUXUS electronics with DSP and dual μp, high sampling rate, be used as a step adaptive signal processing increased accuracy in non-ideal con- intuitive stowing and finding of all components ditions thanks to new algorithms, e.g. for the correction of pipe wall echoes watertight (IP67) and transducer positioning errors offers protection in humid and dirty environments Easy operation automatic loading of calibration data and transducer identification prevents parameterization errors, speeds up the set-up and ensures precise measurement intuitive user interface high-contrast, easy-to-read display with backlight 7

Focusing on energy Portable energy measurement In times of rising energy prices and environmental regulations, optimization of energy flow is a most crucial issue. Everywhere, controlling and balancing the flow of energy is of utmost importance for cost conscious users: for the heat delivery from central heating plants to the end user, for the cold supply in a building's cooling systems, for heat transfer flows in industrial processes, etc. In the Energy version, the FLUXUS F601 can record the energy flows in a system in a quick and straightforward way. FLUXUS F601 measures the instantaneous thermal output of a system, i.e. the flow of heat or cold. Thanks to an integrated totalizer, FLUXUS may also be used as an energy meter. An interface enables the easy transfer of measurement data to a PC for display and evaluation. The gathered data can be used to draw an energy balance or to assist process monitoring and optimization. INLET OUTLET Temperature measurement Flow measurement v v T INLET T OUTLET Temperature measurement FLUXUS F601 measures the energy consumed by a system by determining the heat or cold flows entering and exiting the latter (difference method). For this, it is necessary to measure the supply and return temperatures, as well as the volume flow through the consumer system. FLUXUS uses the measured values to calculate the energy flow based on the heat transfer media's enthalpy curves stored in the internal memory. 8

FLUXUS F601 A meter for all applications Applications Unmatched in performance, the handy and versatile FLUXUS F601 is ideally suited for service and maintenance activities, for instance when commissioning systems, for the maintenance and inspection of permanently installed measuring instrument, for checking pumps or control valves, or as a temporary substitute for defective instruments. General Service Replacement of defective meters Support of commissioning process and installation Performance and efficiency measurement Evaluation and assessments Capacity measurement of pumps Monitoring of regulating valves Food and beverage industry CIP and SIP optimization Consumption optimization Chemical industry Portable flow controls at start-up and/or inspection of facilities Helpful tool for facility optimization Flow measurement of heat transfer media Detection of fouling processes in heat exchangers Control and evaluation of built-in systems according to ISO Water supply / wastewater services Leakage control Treatment dosage control Flow control in water supply networks Heating, ventilating and air conditioning Measurement of inlet and outlet flows for service work and maintenance Measurement/invoicing of energy deliveries Pump preventative maintenance and checks Optimization of energy efficiency Facility management Optimization of heating and air conditioning systems in large building complexes Pump control Short-term replacement of defective wetted heat counters Aeronautical industry Monitoring of hydraulic systems in airplanes Measurement of fuel or refrigerant flows

Technical data Ultrasonic Transducer (Transmitter/Receiver) Ultrasonic Transducer (Transmitter/Receiver) t t v FLUXUS F601 is available in three versions: Standard, Energy, and Multifunctional. These versions differ in their equipment with signal inputs and outputs (see table below). The transducers need to be selected according to the application. Transducers are available for a diameter range from DN 6 to DN 6500 and for temperatures from 40 C to 400 C. Our application engineers will be happy to assist you for a precise adaptation of the measuring system to your requirements. Measuring principle The Transit Time Difference Correlation Principle makes use of the fact that the time-of-flight of an ultrasonic signal is affected by the flow velocity of the carrier medium. Like a swimmer working his way across a flowing river, an ultrasonic signal travels slower upstream than downstream. Our instrument works according to this transit-time principle: an ultrasonic pulse is sent downstream through the medium, another pulse is sent upstream. By measuring the transit time difference, the average flow velocity can be determined. The volume flow can then be calculated out of the flow velocity and the pipe parameters. General technical specifications Transmitter: F601 Quantities of measurement: volume flow, mass flow, energy flow (optional), flow velocity Operating time with battery: >14 h Operating temperature: 10 C... 60 C Flow channels: 2 Degree of protection: IP65 acc. to EN60529 Flow velocity: (0.01... 25) m/s Resolution: 0.025 cm/s Repeatability: 0.15 % of reading ± 0.01 m/s Accuracy* with 7-point wet calibration: 1.2 % of reading ± 0.01 m/s with field calibration: 0.5 % of reading ± 0.01 m/s** Inputs and outputs: Standard: Outputs: 2 x current, 2 x binary Energy: Inputs: 2 x Pt 100/Pt1000; Outputs: 2 x current, 2 x binary Multifunctional: Inputs: 2 x Pt 100/Pt1000, 2 x current; Outputs: 4 x current, 2 x binary * under reference conditions and with v > 0.15 m/s ** if reference uncertainty better than 0.2 % 10

Compact, competent...... and complete The complete measuring system and the required accessories fit into a sturdy protective transport case. The case's dimensions are in accordance with airline requirements for carry-on luggage. Software FluxData, RS232 and USB cables Manual and quick-start guide Please see the price lists for details on the scope of delivery and the accessories. Special accessories are possible. Our application engineers will be pleased to advise you. Measuring tape Power adapter / charging unit Coupling compound Mounting fixture for the transducers Wall thickness probe Flow transducers QuickFix pipe mounting system for the transmitter FLUXUS F 601 transmitter 11

FLEXIM A short portrait For over 15 years FLEXIM has been an active leader in many areas of process instrumentation in both national and international markets. In addition to non-invasive flow measurement systems, FLEXIM specializes in innovative online process analysis using ultrasonic technology and refractometry. Year after year, the Berlin based company continues its substantial investment in research and development in order to maintain and further improve its position as an industry leader. As a result, our customers benefit greatly from our cutting edge patented technology. Competent and professional associates in our sales offices and regional headquarters in Europe, North America, Asia and all over the world ensure the distribution of FLEXIM s proven technology and guarantee you qualified service. FLEXIM GmbH Berlin, Germany Tel. +49 30 93 66 76-60 Fax +49 30 93 66 76-80 info@flexim.de www.flexim.com FLEXIM AMERICAS Corporation Headquarters 250-V Executive Drive Edgewood, NY 11717 Phone: (631) 492-23 00 Fax: (631) 492-21 17 Toll free: 1-888-852-7473 (North America only) usinfo@flexim.com www.flexim.com BUF601V2-1EN. Subject to change without notification. 2009/06 FLEXIM Instruments Asia Pte Ltd Singapore Phone: +65 67 94 53 25 Fax: +65 68 62 28 36 asia@flexim.com Shanghai, China Phone: +86 (21) 649 575 20 shanghai@flexim.com