Deploying a Condition- Based Maintenance Strategy in the Hydro Power Business

Similar documents
DTE Energy: an Enterprise PI approach

Intelligent Lifecycle Asset Management Cradle to Grave Data Utilization in Transportation

Achieving Operational Efficiencies through On-Line Substation Monitoring. Vince Polsoni Powerstream Inc. Manager Station Sustainment EDIST 2016

Predictive Maintenance by Sending PI Notifications to SAP PM to Initiate Automatic Maintenance Tasks

Advanced Monitoring and Diagnostics:

Overview of the PI System Enabled Integrated Refinery Information System (IRIS) at YASREF

Improving Distribution Reliability with Smart Fault Indicators and the PI System

The Journey To Real-time Operational Intelligence

Enterprise Approach to OSIsoft PI System

Asset Health in Real-Time

Advansoft ODM PLANT MOBILE DATA MANAGEMENT & DECISION SUPPORT SYSTEM

Fleet Optimization through Process Information. Sumanth K. Makunur 2/13/13

Copyright 2016 OSIsoft, LLC

Achieving Uniform Global Production Efficiency and Quality with OSIsoft s PI System

Big data revolution Case LV Monitoring

How to Monitor Large & Live Data Centers. PI makes data centers Green!

Water Services Corporation SCADA A Tool for Efficient Resource Management

R&D in Vattenfall Johan Söderbom

KPI, OEE AND DOWNTIME ANALYTICS. An ICONICS Whitepaper

M&D Centers and Scientech s Remote Performance Monitoring Center Scientech User Symposium January 15, 2009

Unlocking Operational Intelligence

PI System Case Studies in the Cement Industry

Stuart Gillen. Principal Marketing Manger. National Instruments ni.com

Implementing a Long Term Asset Management Strategy with the PI System

Ocean Data Systems Ltd. All rights reserved

Industry Solution. Predictive Asset Analytics at Power Utilities

SAP Preventive Maintenance The Core and More. Len Harms - Vesta

Building Business Intelligence in Pipeline Operations. Copyright 2015 OSIsoft, LLC

Proactive Asset Management with IIoT and Analytics

NRG Energy Using PI WebParts to Improve Overall Performance

USERS CONFERENCE Copyright 2016 OSIsoft, LLC

A Data Collection Revolution?

Boost engineering performance with mobile SCADA and maintenance. Reduce downtime Eliminate paperwork Cut costs Meet KPIs

SPPA-D3000 Plant Monitor Technical Description

2012 Honeywell Users Group EMEA. Sustain.Ability. Gary Peacock Global Solution Marketing Manager, Asset Management

July 2016 Price List

Thermal Modeling and Analysis of a Wind Turbine Generator

Arun Veeramani. Principal Marketing Manger. National Instruments. ni.com

The PI System and Hadoop: Unleash the Power of Big Data

Vattenfall Eldistribution AB, Sweden Project AMR Automatic Meter Reading

Uniformance Asset Sentinel. Advanced Solutions. A real-time sentinel for continuous process performance monitoring and equipment health surveillance

Expanding Uniformance. Driving Digital Intelligence through Unified Data, Analytics, and Visualization

Connecting Space and Time OSIsoft & Esri

Condition Monitoring and Maintenance Systems. Condition Monitoring for Industrial Applications

Asset Life Cycle Management

Migrating to AF and AF driven Power applications

BU Control Technologies, Decathlon TM Product Overview. ABB in the Data Center Overview

Leveraging the PI System at Origin Generation MSC

ABB PSPS Erich Steinmann; Generator control-2013

How To Use Netbiter

UK Power Networks Distribution Network Visibility

US Nuclear Regulatory Commission (NRC): National Scale/Fleet Situational Awareness and Emergency Response - Lessons Learned

Enhancing Business Performance using Integrated Visibility and Big Data

ON-LINE MONITORING OF POWER PLANTS

Risk profile table for deployment of releases to the main web site. High Acceptable Unacceptable Unacceptable

A NOVEL CONCEPT FOR SUBSTATION MAINTENANCE MANAGEMENT. Rolf Nordin 1, Lars-Göran Nielsen 2 and Anders Vikman 3

FUTURE DATA Yes, it s finally coming to the PI System!

Installing and Configuring Microsoft SQL Server 2012 Express PI AF

ICONICS GEO Productivity Portals Target Renewable Energy Solutions

Industrial IT Process Data Management. Advanced IT Tools for Building Information Systems in the Process Industry

Integrating Predictive Models and Microsoft BI

REGER Project Electrical Energy Distribution Monitoring

800xA Smart Client Frequently Asked Questions

2012 Honeywell Users Group Americas. Sustain.Ability. Ron Stallworth Asset Management

SWITCHING STRATEGIES: MOVING TO CONDITION- BASED MAINTENANCE. By David Stevens, Technical Manager & Trainer, AVT Reliability

Driving intelligent business decisions through integrated Terminals, Gantry, Offsite Solutions

On-line PD Monitoring Makes Good Business Sense

at ENEL, Italy s largest power company

Smart Cloud Solutions

WATCHMAN Reliability Services Enhance OEM Service Center Revenue

The Road Ahead: Bridging Platform Releases 1 and 2. Ken Marsh Service Manger OSI Software Asia

Application Station Software Suite

Efficient remote access to machines and plants with SIMATIC

GE Measurement & Control. Remote Comms System. Installation and User Reference Guide

HART Device Object Type ifak System is HRT USB Version 1.1

Observer and OPC

Presented by. Dr. Osvaldo A. Bascur, IP and OSIPress Initiative

The PI System. The Foundation for Enterprise Analytics, Visualization, & Collaboration in Context. Business to Operations Value.

Data Centers: Definitions, Concepts and Concerns

PMDD WIND TURBINE 1.5MW

Smart Grid Challenges and Opportunities the Norwegian Perspective

Enterprise Asset Performance Management

Connect. Simplify your condition monitoring programme with subscription-based software. The Power of Knowledge Engineering

The Fortlax 2 Vault offer. Här kan man lägga en rubrik

ABB solar inverters. User s manual ABB Remote monitoring portal

Monitoring Underground Power Networks

Industrial Requirements for a Converged Network

Stefan Sjöström, SEABB, PAPI UGM Automation ABB Underground mining Mobile Integration. ABB Group May 18, 2015 Slide 1 3BSE

Vijeo Citect Architecture and Redundancy Study Guide

Create Value with Data Analysis from PI System Infrastructure

Intelligent Vibration Monitoring

The Best Solution for Energy Monitoring and Efficiency

Transcription:

Deploying a Condition- Based Maintenance Strategy in the Hydro Power Business Presented by Magnus Holmbom

Hydro Power The backbone of Swedish electricity production Electricity production in Sweden [TWh] 180 160 140 120 100 80 60 Gas Condensing Heat Nuclear Wind Hydro The Laxede hydro power plant (Lule river) 40 20 0 1970 1972 1974 1976 1978 1980 1982 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 2008 2010 The Akkats hydro power plant (Lule river) 2

Vattenfall Hydro Power The Third Largest Hydro Power Producer In Europe PI pilot project plants Vattenfall Hydro Power - Nordic Number of employees ~ 520 Annual turnover ~ 950 M Assets, production och capacity Large-scale power plants 55 (1 in Finland) Small-scale power plants 50 (9 in Finland) Annual production 30-35 TWh Capacity 8.300 MW Investments in refurbishment For the period 2013 to 2023 1.400 M Large-scale hydro power plants in Sweden 3

Background Need for a new strategy for Condition- Based Maintenance Old data historian system not sufficient to support new strategy PI System evaluated and used previously in Vattenfall, and decided leading solution Management team made a decision to start an analysis phase to evaluate if the PI System could replace the existing system support the new strategy and vision add value by being flexible, able to integrate with other systems, and support a planned Hydro Information Portal Source: OSIsoft s CBM Guidebook 4

Our one year journey with the PI System Project phase Tasks 2014 Q1 2014 Q2 2014 Q3 2014 Q4 2015 Q1 2015 Q2 2015 Q3 2015 Q4 2016 Q1 2016 Q2 2016 Q3 Analysis Planning the PI System pilot project System setup Training session 1 (server, interfaces) Interface setup and testing Project team with 6 persons, including project manager Steering group with 6 line managers (main stakeholders) Results from the project published on the intranet and presented at line manager meetings within the maintenance organisation Training session 2 (visualisation) Exploring the PI System Conclusions in a pilot project report Planning Establishment Specification (displays, AF, calc s, rounds, ) Planning Roll-out to first maintenance team Evaluation Planning Realisation Roll-out to remaining 19 maintenance teams 5

System setup (pilot) Akkats Seitevare Messaure Vietas Local DCS Siemens S7 WinCC (OPC Server) Local DCS ABB 800 xa (OPC Server) Dam instrumentation Local DCS Old analog Vibration instrumentation Conwide Concentrator (OPC Server) Local server (Vietas) SKF @ptitude (OPC Server) Regional server (Control Centre Vuollerim) Local server (Seitevare) PI Interface OPC DA (with buffering) PI Universal File & Stream Loader Campbell Loggernet (OPC Server) PC Windows PI ProcessBook PI Manual Logger PI DataLink (Excel) PC Web OPC = Open Platforms Communication (IEC 62541) Setup was chosen in order to test data capture from modern DCS s, old analog DCS s, dam instrumentation system, and vibration monitoring system OPC DA communication secured with Matrikon OPC Tunneler (Softing datafeed OPC Tunnel will also be evaluated) PI Universal File & Stream Loader Interface used for importing data from the Conwide system Windows Authentication (Kerberos) for user access PI Server 1 Central servers PI Coresight 2 Asset Framework PI Coresight PI Manual Logger Web MS Internet Information Services MS SQL Server Tablet Web PI Manual Logger Web PI Coresight Mobile 6

Conclusions from the pilot project The pilot project verified that the PI System 1. is an adequate replacement for the current Conwide system, and fulfills the needs for both plant maintenance and dam safety; 2. provides added value with a more stable data capture, a richer analysis functionality, and flexible integration possibilities; 3. provides the prerequisites and supports the vision and strategy for our future maintenance development; 4. represents an important building block of a planned Hydro Information Portal, publishing e.g. process data, analyses and KPI s in real-time. 7

The PI System as part of the IT landscape Future plan Existing Future RCM Analysis Asset Mgmt Investment Planning Asset Mgmt Investment Planning (new) SAP PM Failure modes Criticality indexes Condition indexes Notifications Technical indexes AF sync Power Plant DCS s Measurement data The PI System Displays Hydro Information Portal Production control Control Centre SCADA s Production data PI System data PI Cloud Connect External contractors Universities R&D 8

Trend Analytics 9

Element template setup 10

Create element from template 11

Trend index calculation 12

Make analyses easy Reduce complexity by getting the highest value out of a population 13

Using multiple normal values If machine is running then analyses is using 75 mm else it is using 90mm 14

Overview of trends English translation Plant unit Turbine Turbine guide bearing Stuffing Barrier water Leakage water Pressure oil Generator Generator chamber Stator winding Generator cooling Excitation transformer Thrust Bearing Bearing cooling Pressure lubricating oil Upper guide bearing Lower guide bearing Brake compressor Vibrations 15

Individual trends using element relative displays 16

Notification setup 17

Delivery of notification 18

Create notification in SAP PM 19

Failure Mode Analysis 20

Failure Mode Analysis 1. Choose subsystem and use system descriptions and functional descriptions 2. Analysis of current maintenance activities (CMMS) 3. Map all known failure modes to maintenance activities (FMEA) 3 1 2 21

Failure Mode Analysis, cont. 4. Go through all notifications in CMMS. Are there any new failure modes previously unidentified? Fault frequency analysis. 5. Which failure modes may be identified with condition monitoring? 5 4 Symptoms Failure modes for break system Condition monitoring Sensor needs 22

Failure Mode Analysis, cont. Asset structure Fault modes from RCM Calculation of technical index ( Analyses tab) 6. Which measurements are required? (Process to install new sensors) 7. Define a general analysis model 8. Adapt to local conditions by using parameters (requires deeper local knowledge of each power plant) 9. Classify normal and deviating conditions in 5 levels (technical index) Calculated index, to be presented in a display and/or used to generate a notification 23

Comparing startup event sequences 1 Locked Different time range 2 24

Alarm during startup Alarm 25

System overview Thrust Bearing cooling 26

Deploying a Condition-Based Maintenance Strategy in the Hydro Power Business We needed to implement a new strategy and the existing IT solution did not provide the necessary functionality for this. After a thorough evaluation project in 2014, we are now deploying the PI System and use many of the possibilities in the implementation of the new strategy. Stina Pettersson Head Of Maintenance Development Vattenfall Vattenkraft AB Business Challenge Need for a new strategy and standardised methodology for Condition-Based Maintenance Old data historian system is not sufficient Solution Implementing the PI System as data infrastructure, analytical modeling and presentation tool Use of Android tablets for on-site manual rounding with PI Manual Logger and visualization of PI System data through PI Coresight displays Results and Benefits Improved common continuous monitoring of the hydro power plants Reduced costs for unplanned maintenance (~1.5% of total maintenance costs) Increased accuracy in asset condition assessment 27

Magnus Holmbom magnus.holmbom@vattenfall.com Maintenance Development Engineer Vattenfall Vattenkraft AB 28

Questions Please wait for the microphone before asking your questions Please don t forget to Complete the Online Survey for this session State your name & company http://eventmobi.com/emeauc15/ 29

THANK YOU Brought to you by 30