SG-P1 Both-End Shaft Type
SG-P1 Both-End Shaft Type Reducer (0.1kw) Input Output 4.) In the case of 1/5-1/50 ratio, input /output shafts rotate in the same direction, and 1/60-1/200 ratio, opposite direction. 5.) These figures shown above are measured under the condition of 0.1kW4P.
SG-P1 Both-End Shaft Type Reducer (0.1kw) 4.) In the case of 1/300-1/1200 ratio, input /output shafts rotate in the same direction. 5.) These figures shown above are measured under the condition of 0.1kW4P.
SG-P1 Both-End Shaft Type Reducer (0.2kw) Input Output 4.) In the case of 1/5-1/30 ratio, input /output shafts rotate in the same direction, and 1/40-1/1200 ratio, opposite direction. 5.) These figures shown above are measured under the condition of 0.2kW4P.
SG-P1 Both-End Shaft Type Reducer (0.2kw) Stages Actual Ratio Output Speed (r/min) Allowable Torque Allowable Torque Overhung Load (N) Stages Actual Ratio Output Speed (r/min) Allowable Torque Allowable Torque Overhung Load (N) 4.) In the case of 1/300-1/1200 ratio, input /output shafts rotate in the same direction. 5.) These figures shown above are measured under the condition of 0.2kW4P.
SG-P1 Both-End Shaft Type Reducer (0.4kw) WL2-04-5 (-25) WF2-04-5 (-25) Allowable Torque Stages Actual Ratio Output Speed (r/min) Allowable Torque Overhung Load (N) Input Output WL2-04-30 (-80) WF2-04-30 (-80) Allowable Torque Stages Actual Ratio Output Speed (r/min) Allowable Torque Overhung Load (N) Input Output WL2-04-100 (-200) WF2-04-100 (-200) Input Output 4.) In the case of 1/5-1/25 ratio, input /output shafts rotate in the same direction, and 1/30-1/200 ratio, opposite direction. 5.) These figures shown above are measured under the condition of 0.4kW4P.
SG-P1 Both-End Shaft Type Reducer (0.4kw) WL2-04-300 (-450) WF2-04-300 (-450) Input Output 4.) In the case of 1/300-1/450 ratio, input /output shafts rotate in the same direction. 5.) These figures shown above are measured under the condition of 0.4kW4P.
SG-P1 Both-End Shaft Type Reducer (0.75kw) WL2-08-5 (-25) WF2-08-5 (-25) WL2-08-30 (-80) WF2-08-30 (-80) WL2-08-100 (-200) WF2-08-100 (-200) 4.) In the case of 1/5-1/25 ratio, input /output shafts rotate in the same direction, and 1/30-1/200 ratio, opposite direction. 5.) These figures shown above are measured under the condition of 0.75kW4P.
SG-P1 Both-End Shaft Type Reducer (1.5kw) WL2-15-5 (-25) WF2-15-5 (-25) WL2-15-30 (-80) WF2-15-30 (-80) 4.) In the case of 1/5-1/25 ratio, input /output shafts rotate in the same direction, and 1/30-1/80 ratio, opposite direction. 5.) These figures shown above are measured under the condition of 1.5kW4P.