BAUER High Pressure Sports & Safety Compressor Model PE TE / TW / TB Charging Rate: 100 l/min

Similar documents
Rotary screw compressors kw 5,5 7, , bar MODULO

Kompressoren. Adsorption Dryer AD

HIGH PRESSURE INDUSTRIAL COMPRESSOR UNITS 225 bar 330 bar Model range MINI-VERTICUS 3

Instruction Manual Junior II. Junior II INTRODUCTION

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Adsorption air dryers ADS 1 215

ECOCIAT. Domestic hot water heat recovery unit

Assisted lift operated 2/2-way solenoid valves Type EV250B

Atlas Copco Stationary air compressors

OIL-FREE ROTARY SCROLL COMPRESSOR. ECOLIFE 1,5 15 kw

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Single sub-base valve

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

3/2-way Solenoid Valve, direct-acting, NC or NO

Series description: Wilo-Drain TC 40

ThermoSorb Desiccant Dryers

Compact Air Solutions C Series kw Screw Compressors Want a 5. year warranty? Ask for details!

Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit

Combi switchbox with integrated 3/2 way pilot valve

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Compressors, Enriched Air Systems & Air Monitoring

MANTA Piston Distributor for Oil and Fluid Grease

4/2-Way Pneumatic Solenoid Valve

Medical Air Systems: Scroll

Rotary Screw Compressor. MSM MINI 2, ,5 kw

Screw Compressors 11-22kW

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1

clean and quiet dental

Brownie s. Tankfill. and. NitroxMakers

2/2 and 3/2 Way Size 6 Seat Valves

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Atlas Copco. Oil-injected rotary screw compressors GX e 7-22 (7-22 kw / hp)

industry revolves around

Kompressoren. Oil Water Separators OWS

Model 2128 AIR COMPRESSOR PUMP Operating Instructions

LC/LCD ranges level controllers

Electro-pneumatic control valves

Technical Specification. Generating Set with Waukesha engine burning natural gas

SIR INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES

ASSEMBLED SOCKET-COMBINATIONS

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

HYDRAULICS Hydraulic Ground Power Unit - Mainline Aircraft 3000psi and 5000psi >Hgpu<

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

ROTARY SCREW COMPRESSOR. RMD kw

3753 en /b VE/B - VE/RG Va V riable speed drives

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Atlas Copco Industrial Aluminium Piston Compressors. L Series Oil-lubricated & oil-free ( kw / 2-20 hp)

Refrigeration Compressed Air Dryer Buran Ultrapulse

AIRROLLAIR COMPRESSORS E

Electric Flow Boiler

Conlift1, Conlift2, Conlift2 ph+

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Actuator-Sensor-Interface

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

ARB AIR LOCKER Air Operated Locking Differentials

Mini slide, Series MSN narrow version Ø 6-16 mm double-acting with magnetic piston cushioning: elastic with integrated ball rail guide

SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Engine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 )

Technical data UNIBLOCK UBSF

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

TIMER CONTROLLED DRAINS

3/2-way pneumatic cartridge solenoid valve

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

CG PTFE Diaphragm Liquid Transfer Pump

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

RS-D and RSF-D series with direct drive

Please keep these operating instructions in a safe place.

Refrigeration Air Dryers. Catalogue

NITROX // safer diving

Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

Control- and feedback head for integrated mounting on Robolux valves Type 2036

CNG / CBG. your high pressure solution. compressors for turn-key refuelling stations. CNG/CBG

Sauer Compressors. for the Navy. reliable competent references

Centro-Matic Automatic Lubrication Systems System Controls

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Technical data. Danfoss DHP-A

MOLECULAR DRAG PUMPS MDP SERIES

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

I STAR COMPUTER CO., LTD

Refrigerated Air Dryers. Catalogue

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

Single- and Multi-circuit Pumps

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Transcription:

BAUER High Pressure Sports & Safety Compressor Model PE 100 - TE / TW / TB Charging Rate: 100 l/min The mobile high pressure breathing air compressor is used to fill pressure tanks for respiratory protection, diving and shooting sports and other applications. The maximum allowable operating pressure (final stage safety valve setting) is for units 225 bar or 330 bar. PE100 -TE www.poseidon-edition.com page 1

General Medium : air Intake pressure : atmospheric Intake temperature : +5 to +45 C Ambient temperature : +5 to +45 C Setting of safety valve : 225 or 330 bar Filling pressure : PN 200 or PN 300 Compressor block Capacity Number of Compression stages 3 Number of Cylinders 3 Stroke 24 mm Drive V-belt Three-phase AC motor Power 2,2 kw 2.850 1/min Enclosure IP55 Operating voltage 400 V 1 Frequency 50 Hz 1 Single-phase AC motor Power 2,2 kw 2.850 1/min Enclosure IP55 Operating voltage 230 V 1 Frequency 50 Hz 1 1 Other voltages and frequencies available on request against additional price. 100 l/min Measured at bottle filling 0 to 200 bar Tolerance +/- 5% at +20 C ambient temperature 2300 1/min Petrol engine Type Power 4-tact-gas engine 4.2 kw 3600 1/min Dimensions/Weight: Model Length x Width x Hight Weight (approx.) PE100 - TE 660 mm x 350 mm x 420 mm 44 kg PE100 - TW 660 mm x 350 mm x 420 mm 44 kg PE100 - TW Shooting version 660 mm x 350 mm x 420 mm 44 kg PE100 - TB 740 mm x 340 mm x 420 mm 42 kg www.poseidon-edition.com page 2

Scope of supply: COMPRESSOR BLOCK - Splash lubrication - Micronic intake filter: 10 µm - Intermediate coolers, air cooled - Aftercooler, air cooled, outlet temperature max. 10-15 C above cooling air temperature - Intermediate separators after the 2 nd stage - Final separator for removal oil-/water condensate - Safety valves after each stage, TÜV approved final pressure safety valve - Pressure maintaining and check valve after the final stage FILLING DEVICE PN 200 or - 1x filling valve with integrated vent, complete with German filling connector G 5 / 8 " DIN 477 and pressure gauge, PN 200-1x high pressure filling hose, 1 m length - 1x international filling connector FILLING DEVICE PN 300-1x filling valve with integrated vent, complete with German filling connector G 5/8" DIN 477 and pressure gauge, PN 300-1x high pressure filling hose, 1 m length www.poseidon-edition.com page 3

or FILLING DEVICE FOR PE 100 - TW SHOOTING VERSION 1 filling hose, length 1 m, 1 filling valve and final pressure gauge, 1 adaptor 2x5/8 for connection of cartridge adapter, suitable for all manufacturing brands FILTERSYSTEM P 11 - final mechanical separator for the removal of oil-/ water condensate - TRIPLEX long-life filter cartridge processing in 3 stages (drying, neutralization, micro filtering) - filling: MS-AC-MS - air purification capacity approx. 90 m³ (at ambient temperature 20 C and 200 bar) - final safety valve, fitted to filter housing - back pressure / non return valve, fitted to filter housing Technical data: Operating pressure: Operating pressure: max. 330 bar min. 90 bar All filter housings comply with UVV standards, AD guidelines and German TÜV regulations. Other housing standard compliances can be provided at additional costs if required. www.poseidon-edition.com page 4

Air quality according to DIN/EN 12021 Contamination Threshold value according to DIN EN 12021 Air quality due to application of BAUER prufication system P 21 H2O 25 mg/m³ 10 mg/m³ CO CO2 15 ppm(v) 500 ppm(v) Depending on filter cartridge 1 Depending on intake air ² Öl 0,5 mg/m³ 0,1 mg/m³ 1 With BAUER filter cartridge MS/AC/MS/HP only. Maximum concentration CO in intake air: 25 ppm. The compressed and purified breathing air will then comprise 5 ppm CO (threshold limit European pharmaceutical book) 2 When the max. allowable concentration of CO 2 in the intake air is exceeded, the application of the additional purification system BAUER AERO-GUARD is strongly recommended! OPTIONS: ON/OFF SWITH WITH MOTOR PROTECTION - On/off switch - Cable, length 5 m - CEE plug (only with operating voltage 400 V / 50 Hz) SPECIAL VOLTAGE / FREQUENCY The standard voltage and frequency is 400 V, 50 Hz three phase AC. Other voltages and/or frequencies can be delivered upon request (add. price). www.poseidon-edition.com page 5

ADDITIONAL OPTIONS FOR PE 100 - TW SHOOTING VERSION DISTRIBUTION PANEL for the filling of 300 bar and 200 bar cartridge. Filling panel with mounting rail complete with: 1x connection for the hose 1x cartridges connection G 5 / 8 " DIN 477, PN 200 with shut-off valve 1x safety valve 225 bar 1x cartridges connection G 5 / 8 " DIN 477, PN 300 with shut-off valve FILLING BRIDGE for the filling of 225 bar storage bottles, 2x bottles connection G 5/8" DIN 477, PN 200 1x high pressure filling hose, 1 m length MULTI-FILL The Multi-Fill filling panel is available as optional extra. It is used to fill as many cartridges as needed, even different types, of one pressure range at the same time. The Multi-Fill panels are connected to each other by means of tube connector. www.poseidon-edition.com page 6

Service Material: Maintenance kits Maintenance kit 500 hours Maintenance kit 1000 hours Maintenance kit 2000 hours Order No. A-JuniorII-F4-a1 A-JuniorII-F4-ab1 A-JuniorII-F4-abc1 Spare Cartridges Filling Purification capacity 1 Order No. Standard MS-AC-MS 130 m 3 057679 with CO-removal MS-AC-MS-HP 110 m 3 059183 1 referring to +20 C in the oil-/ water separator and processing pressure 300 bar MS = Molecular Sieve = Drying AC = Activated Carbon = Oil removal HP = Hopcalite = CO-Removal Documentation: Standards: Testing: Standard units: 1x Instruction manual and parts list in English or German language Special versions: 1x Instruction manual together with the unit, spare parts list 6-8 weeks after delivery. Manufacturing according to German regulations and standards Bauer standard according to DIN EN 10204-3.1B All information is subject to change without notice. www.poseidon-edition.com page 7