T h e S y s t e m X T t h e m o d u l a r solution for today and for the future

Similar documents
SENSOR NET. The modular multi-parameter measuring system. With special security features for fail-safe operation, such as:

IQ SENSOR NET MIQ/JBR

40.3. Control Relays and Timers

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Temperature & Humidity SMS Alert Controller

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Modular I/O System Analog and Digital Interface Modules

Multi-Range Programmable DC Power Supplies 9115 Series

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

Documentation. M-Bus 130-mbx

Hand-held thermometer Model CTH7000

Product Information Sheet UH36 Hi Pot Tester

Section TELEPHONE AUTOMATIC DIALER SYSTEM

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Multi-Range Programmable DC Power Supplies 9115 Series

OZW30. Central Unit SYNERGYR

2.24. Pump Controller 704. Data Sheet

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Duct Humidity Transmitter

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Product Information Fire alarm panel 8000 C

TX OPEN RS232/485 module

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007

Application/Connection Examples

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

4-Channel Thermometer / Datalogger

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Repeaters and Mimics Data Sheet

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Emergency lighting units EM powerled

Technical Information RIA14

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Digital input modules

DC Electronic Loads 8500 series

Product Specification instalert Rapid Messenger Variable Message Sign

Web-Based Remote Monitoring & Datalogging

1.44 kw Programmable DC Power Supplies XLN Series

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

1 Technical Description Lokal-200PC

Digital inductive conductivity transmitter

HARTING mcon 1000 Introduction and features

ALARMLINE ANALOGUE Linear Heat Detection System

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

PowerCommand 500/550 Remote Monitoring System

Regards from the Team at Rheology Solutions.

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

T0118 T2118 T3118. Instruction Manual

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

High Power Programmable DC Power Supplies PVS Series

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Processor. Installation Guide

PCS0100en Persy Control Services B.V. Netherlands

Technical Data Sheet. 3DLevelScanner

How To Use A Ds340 (Dsp)

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

DVI KVM Switches DP-MUX 7.4

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

MINIMAT-EC-Servo Screwdriver Spindles

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

User's Guide. Integrating Sound Level Datalogger. Model Introduction

PRODUCT LIST Facility DDC Access WebXL DDC

DCS Data and communication server

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

3500/93 System Display

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Panel Meters and Controllers Modular Panel Meter Type EDM 35

FX07 Field Controller

PIEZOMETER AIRFLOW MEASURING RING

MANUAL PC1000R

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Quick Connect. quick - simple - efficient.

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

OT 40L / 90L. Laboratory Steam Sterilizers

BOGE AIR. THE AIR TO WORK. CONTROLS

FIREDEX Conventional Fire Panels

Transcription:

T h e S y s t e m 2 0 2 0 X T t h e m o d u l a r solution for today and for the future Do you plan a sensor network with multiple sensors or to upgrade your installation step by step? The System 2020 XT represents the perfect solution for these challenges: It is designed fully modular and will keep on growing at the pace of your growing demand. This flexibility makes the system very appealing also for small, medium-sized, but also for larger sewage plants. Any conseivable application can be fulfilled including discharge measuring with the parameters turbidity, ph, conductivity and temperature, furthermore the control of nitrification/denitrification and also complete sewage plant analytics being supported by one single system at considerable low investment costs and highly economical operation all accomplished by an easy to handle system. System 2020 XT USB interface Electronic-Key IQ-LabLink Important system features Up to 20 digital IQ sensors at user s choice may be connected Easy system expansion, no previous knowledge required Centralized power supply using a wide range power supply (100 240 VAC) or 24 V variant A nearly unlimited number of relays and analog outputs (0/4-20 ma) may be selected Digital outputs PROFIBUS DPV1 or Modbus RTU Optional modem connection via analog or GSM modem Wireless connection via radio transmission Easy integration of existing measuring points by ma inputs Local identity function The local identity function is integrated in each module with a memory element. With the configuration this memory element can carry all system relevant information i.e. location and description of measuring point as well as considering all connected sensors. When setting the terminal the complete information is displayed and enables i.e. fast identifying of sensors for calibration purposes. Diagnosis via LEDs Each module sideways shows 2 clearly visible LEDs (yellow/ red) for diagnostic purposes. These LEDs signalize whether the according module is ready-to-operate (power supply/ data communication). 70

System 2020 XT Terminal / Controller MIQ/TC 2020 XT The terminal / controller MIQ/TC 2020 XT presents the core of each IQ Se n s o r Net System 2020. Its new high-performance processor coordinates all tasks within the network. Via the USB interface an extremely fast data exchange via USB memory stick to any external system directly is possible. The system-status LED gives reliable and fast information regarding function and status of system. When integrating two MIQ/TC 2020 XT in the system, the dual-processor function increases the system stability and therefore also availability of the entire system. Can be operated as terminal and controller all-purpose solution (constantly installed) or as mobile terminal solution. Multi-functional USB interface IQ-LabLink function for easy data exchange with laboratory instruments Electronic-Key function with programmable access permission Increased system stability through dual-processor function Fast status information via LED Analyzer IQ Se n s o r Net Monitors General Description of Meters Improved reading precision through special graphic display Special, extremely bright display with clear glass covering Status LED display Multi-functional USB interface Measuring stations New 4-directional control element Multi-functional USB interface IQ-LabLink function Electronic-Key function Storage of configuration Storage of calibration Logbook recording Storage of recorded data (data logging function) Software upload Status LED display Each MIQ/TC 2020 XT terminal/controller shows a LED for diagnostic purposes on the front. This LED shows normal and malfunctions of the system at a glance. Accessories Samplers Sample Preparation New 4-directional control element For even easier operation 71

System 2020 XT Features and functions Mechanical docking of a terminal A Terminal TC 2020 XT can be easily connected to each module. The electrical contact for the power supply and data communication is made simul taneously with the mechanical connection. Stack mounting of modules Up to three modules can be mechanically connected to form a stack. Simultaneous mechanical and electrical connection to data and power transmission. The individual modules of the stack can be accessed at any time without dismantling the stack by simply undoing two lateral screws. Analyzer IQ Se n s o r Net Monitors General Description of Meters Distributed mounting of modules MIQ/T2020 or MIQ/T2020 PLUS All modules can be installed anywhere in the system, both in dividually and in stacks. When not stacked, system com ponents are connected via the 2-wire shielded SNCIQ Sensor Net cable. Each Sensor Net connection of a system component can be used to extend the IQ Se n s o r Net cable. Furthermore, IQ sensors can also be connected directly to the Sensor Net terminals. Measurement display The user can configure the measurement display by selecting between a single, four-fold or multiple view depending on the number of connected sensors. The freely definable de signation of the measuring location is included on each view for easy identification. Stored measured data can be optionally displayed as measuring value lists, daily, weekly or monthly graphs. The respective current measured value can be displayed by following the curve with the cursor. SNCIQ (/UG) Accessories Samplers Sample Preparation Measuring stations 75

P r i n c i p a l s y s t e m a r c h i t e c t u r e IQ Se n s o r Ne t System 2020 XT IQ sensors/connecting modules Terminal-/Controller Output modules analog/digital Max. 20 sensors R Junction boxes MIQ/PS MIQ/24 V Central power supply up to 6 modules/system MIQ/CR3 MIQ/C6 MIQ/R6 Analog output modules (ma/relay) R Junction boxes MIQ/IC2 ma input current box 2 ma inputs MIQ/TC 2020 XT Central unit permanently installed Mobile Terminal Same component differently configured MIQ/IF 232 MIQ/RS MIQ/PR MIQ/MOD MIQ/A-RS MIQ/A-PR MIQ/A-MOD Digital output modules 1 0 1 Further modules MIQ/TC 2020 XT 2 further mobile terminals can be docked onto any module within the system Digital communication with the IQ Net MIQ/RS modul IQ with modem compatible RS-232 interface MIQ/PR modul IQ with PROFIBUS-DP connection MIQ/MOD modul IQ with MODBUS RTU/RS 485 connection MIQ/Blue PS for wireless connection and linking withing the IQ Sensor Net System Network PC + IQ Software Pack Mobile phone Ethernet adapter Null modem cable RS 232 Adapter Land line / GSM / Radio / SMS Data Transfer USB Stick Modem RS 485 Device RS 232 Adapter Modbus PROFIBUS FDT + IQ Software Pack MIQ/IF232 (Diagnostics and service only) USB Interface MIQ/(A)-MOD MIQ/(A)-PR Terminal-Controller Interface modules (Data + Energy) Radio module Radio 100 m Radio module 76 IQ Sensor Terminal Inputs Outputs Eing nge Power supply IQ Sensor Terminal ma Relay ma ma Island 1 Valve Island 2 Additional IQ Se n s o r Net islands possible.

0/4 20 ma analog High impedance signal transmission Analog Monitor: e.g.: - In-line ph measurement - Measurement in hazardous areas - Integration of physical parameters 2 x MIQ/IC2 Universal Input Current Modules Analyzer e.g. Measurement in the effluent - Ammonium - Nitrate - Phosphate IQ Sensor Net digital 0/4 20 ma analog Electrode: HA 405-DXK-S8/255 NTC Pt 100 Pt 1000 Configuration example 1: Configuration example 2: 6 IQ sensors (each 2 measuring points) Large distances between 3 measuring points Mobile terminal can be connected to both Monitoring of 3 aeration tanks with IQ Sensor Net (due to extremely large variety of system variants, only a small selection can be demonstrated and represented as configuration examples). modules, for i.e. obtaining an additional measurement display or for processing a calibration on site. MIQ/T2020 or MIQ/T2020 PLUS 2 x Control Room PROFIBUS ph TS 2 x SNCIQ (/UG) ph TS Samplers TS MIQ/PS PLUS ph MIQ/CR3 MIQ/MC-PR MIQ/T2020 (PLUS) 2 x MIQ/Blue PS Sample Preparation ma/relais IQ Sensor Net Valve assembly: InTrac 777 Analyzer IQ Sensor Net digital Universal Input Current Module MIQ/IC2 Example 2: Integration of an Analyzer Monitors Example 1: Integration of an Analog Monitor General Description of Meters System 2020 XT Example MIQ/ TC 2020 XT-H3 with decentralized assembly Option 1: Calibration indoors Mobile terminal, for use at each measuring point Option 2: Integration of an In-line Measurement Accessories MIQ/T 2020 Laboratory Sensor Calibration Optional branching module in the Laboratory for convenient pre-calibration of IQ sensors WA 700/10 ADA-WA1 ESS-WA 700/VA SensoLyt 700 IQ or ViSolid 700 IQ e.g. In-line ph measurement In-line TSS measurement Measuring stations MIQ/Blue PS Example MIQ/ TC 2020 XT-H3 77

General Technical Data System 2020 XT System Certifications ETL, cetl (conforms with relevant UL and Canadian standards), CE Electromagnetic Compatibility EN 61326, Class B; FCC Class A, EMC for indispensable operation Integrated Lightning Protection According to EN 61326 enhanced overvoltage protection for the entire system, implemented in each component Connection Medium Cable IQ Se n s o r Net cable SNCIQ or SNCIQ/UG (underground cable with additional PVC coating): 2-wire with shield; 2 x 0.75 mm 2 ; Filler cord for easy connection of shield: 0.75 mm 2 ; pressure resistant to 10 bar Connection Characteristics Power supply and data transmission on these wires; resistant to polarity reversal with respect to switched shield and inner conductor (no damage); comprehensive EMC shield control; cable topology within IQ Sensor Net system as required, e.g. in the form of a line, tree, star, multiple star Total cable length: max. 1.000 m/1094 yds (without signal amplifying), with signal amplifying module R additional 1.000 m/1094 yds Connection Medium Radio Radio transmission Class 1 with a range of 100 m/109 yds (max. 300 m/328 yds) Connection Characteristics Data transmission, separate power supply necessary for each island Controller/Terminal MIQ Module Coupling at Rear Combined mechanical and electrical connection, for rapid coupling to MIQ modules USB interface USB-A (host) Display Graphic display; resolution: 320 x 240 pixel; visible area: 4.49 x 3.39 in. (114 x 86 mm), black/white, backlit Control Functions/Function Keys Datalogger Electric Supply 5 operating keys: 3 master keys for functions: Measurement (M), calibration (C), set/system settings (S), 2 keys for: confirmation/switching menu O.K. (OK), Escape (ESC) 4-directional button for rapid selection of software functions and input of alphanumeric values MIQ/TC 2020 XT: Data memory for up to 525,600 data sets Directly via the IQ Sensor Net when coupled to MIQ module Ambient Conditions Operating temperature: -4 F 131 F (-20 C +55 C) Storage temperature: -13 F 149 F (-25 C +65 C) Housing Material ASA (Acrylonitrile-Styrene-Acryloesterpolymer) Protection Rating IP 66 / equivalent to NEMA 4X (not suitable for conduit connection) Dimensions (W x H x D) 8.27 x 6.69 x 1.57 in. (210 x 170 x 40 mm) Weight Approx. 1.54 pounds (0.7 kg) Guaranty 3 years for defects of quality Modules MIQ Module Coupling at Front Combined mechanical and electrical connection for rapid docking and removal of the MIQ/T2020 (PLUS) terminal and the MIQ/C184 XT controller, and for docking additional modules MIQ Module Coupling at Rear Combined mechanical and electrical connection for docking additional modules, a total of 3 modules as a stack mounted unit Cable Feeds 4 screw cable glands M 16 x 1.5 Terminal Connections Screw terminal strips Terminal area for solid conductors: 0.2... 4.0 mm 2 Terminal area for flexible conductors: 0.2... 2.5 mm 2 accessible by opening cover IQ Se n s o r Net Terminal Connections Other Functions Electric Supply Ambient Conditions Terminal connections for the IQ Se n s o r Net are available on each module and can be used as required: - for connecting sensors - as an input/output or for looping through/branching of the IQ Sensor Net cable Two LEDs, yellow and red, for monitoring the operating voltage of the IQ Sensor Net; IQ Sensor Net connection, resistant to reversed polarity; Integrated local identity function; Integrated switchable terminal resistor (SN terminator) Directly via the IQ Sensor Net Operating temperature: -4 131 F (-20 +55 C); Storage temperature: -13 149 F (-25 +65 C) PC 20 % GF (polycarbonate with 20 % fiberglass) IP 66 / equivalent to NEMA 4X (not suitable for conduit connection) 5.67 x 5.67 x 2.05 in. (144 x 144 x 52 mm) Approx. 1.1 pounds (0.5 kg) 3 years for defects of quality Housing Material Protection Rating Dimensions (W x H x D) Weight Guaranty Sensors Mechanical Connections for Connection slot; Connection screw thread G 1 Accessories IQ Sensor Connection Cable Combined mechanical and electrical connection for rapid attachment and exchange of sensors. Consists of jack plug and pressure-resistant screw connection. Cable lengths: 1.64 7.66 16.40 yds (1.5 7.0 15.0 m)/ 21.87 54.68 109.36 yds (20 50 100 m) in sea water design available. Storage temperature: -13 F 149 F (-25 C +65 C) Operating temperature: -4 F +131 F (-20 C +55 C) 78