TXM1.8T. Triac module TX-I/O. Used for Thermic and motor-driven actuators (AC 24 V)

Similar documents
Digital input modules

TX OPEN RS232/485 module

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Air damper actuators

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Input module, input/output module

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

PCS0100en Persy Control Services B.V. Netherlands

HCR3.2/.. Chipcard reader HOTEL SOLUTION

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

VAV compact controller KNX / PL-Link

Product and functional description

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Duct Humidity Transmitter

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Safety technique. Emergency stop module BO 5988 safemaster

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

OZW30. Central Unit SYNERGYR

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

RRV934. Multi-controller. Synco living

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Modular I/O System Analog and Digital Interface Modules

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Contact expansion modules

48 SERIES Relay interface modules 10 A

ABB i-bus KNX SA/S Switch Actuators Product Manual

Three-phase monitoring relay CM-PFE

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

PHOENIX CONTACT Features

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

SYSTEM DESCRIPTION Termination Boards

ACS-30-EU-EMDR-10-MOD

Electronic overload relay EF19 and EF45

Contact expander modules

E-STOP relays, safety gate monitors

R.C.C.B. s two-pole LEXIC

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

Redundancy Module QUINT-DIODE/40

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

MasterINTERFACE 39 Series - Relay interface modules

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

RM4TG20 three-phase network control relay RM4-T - range V

Quick Connect. quick - simple - efficient.

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

VAV compact controller KNX / PL-Link

Bimetallic Overload Relay Specifications

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

Type: DILM32 10(24V50HZ) Article No.:

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

MasterINTERFACE 39 Series - Relay interface modules

MINI MCR-SL-R-UI(-SP)

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

PNOZsigma - Base units

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

5SV Residual Current Protective Devices

IMR 6000/10../20../30

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Thermistor motor protection

13 SERIES. Electronic step relays A

15 Series - Electronic step relay and dimmer. Features SERIE

Electronic overload relay EF65, EF96 and EF146

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

SYSTEM 45. C R H Electronics Design

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Flush-mount room temperature sensor AQR2531ANW.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Transcription:

s 8 179 8179p01 TX-I/O Triac module sed for Thermic and motor-driven actuators (AC 24 V) AC 24 V-controlled devices TXM1.8T 8 triac outputs (AC 24 V), configured individually for: Permanent contact Three-point positioning output with internal stroke model Pulsewidth-modulated output (PWM) Noisefree switching of outputs Compact design as per DIN, requiring little space Separation into terminal base and electronics unit for optimal handling. Self-connecting bus for the easiest possible installation. Isolating terminal function for fast commissioning. Exchange of electronics unit within seconds without a need of rewiring, at full functionality of the remaining I/O modules All terminals are connected directly to the modules, no additional terminal strip for direct connection of field devices. Simple display concept Green LED per output, control action as per I/O function LEDs for fast fault diagnosis Double-sided labeling of all I/O points with label CM2N8179en_06 2016-01-08 Building Technologies

Functions The module supports the following output functions: Signal type TRA Signal type Description BO Triac NO Q250_T Maintained contact BO Triac NC BO 3-Pos Triac Y250_T Pulse, actuating signal, 3-point output, internal stroke model BO PWM PWM Pulse width-modulated output See document "TX-I/O Functions and operation", CM110561, for a detailed description of this function. Compatibility For signal type support and functionality in the various building automation and control systems, see TX-I/O engineering and installation manual, CM110562. Ordering Type Stock number Designation TXM1.8T S55661-J106 Triac module Delivery Accessories Terminal base and electronics unit are assembled and delivered in a box. Address keys, printable label sheets and replacement label holders are available as accessories. See data sheet CM2N8170. Design and technology See the TX-I/O Engineering and installation manual, CM110562, for a description of the properties for all TX-I/O modules. 2 / 8

Operating and display elements Connection terminals (No. 1 screwdriver for slotted or recessed-head * screws) with test plug socket (pins 1.8 to 2 mm) and terminal number. Signal designation Address key and module status LED I/O point numbers Output status LEDs (green) * Combined slotted / recessed-head screws from mid-2012 Output status LEDs Module status LED Address key Terminals The status LEDs indicate the status of the outputs. The module status LED illuminates the transparent address key. The LED (green) indicates the status of the entire module. It can also be used for diagnostic purposes. The module only works with the address key. The module address is mechanically encoded in the address key. Swing out the address key when exchanging the electronics unit. The key remains in the terminal base. Two terminals per output are available to connect the load. The AC 24 V connection is common for all outputs, it comes from the V~ island bus connector. The load is balanced to ground. Each output is protected individually against overload. Module labeling The electronics unit has a removable, transparent lid (label holder) allowing for insertion of the label. 1 2 8172z11 3 / 8

Disposal The device is considered an electronics device for disposal in terms of European Directive 2012/19/E and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Engineering, mounting, installation Please consult the following documents: Document TX-I/O Functions and operation TX-I/O Engineering and installation manual Number CM110561 CM110562 Mounting Allowed mounting positions TX-I/O devices can be mounted in any position: You must ensure, however, that sufficient ventilation is available to maintain the permissible ambient temperature (max. 50 C). Technical data Power supply (side bus connector) Operating voltage range Max. power consumption (see CM110562 for supply design) DC 21.5...26 V (SELV / PELV) or DC 24 V class 2 (S) 1.0 W Protection All module terminals Against short circuit and faulty wiring using AC/DC 24 V. Side bus connector No protection! Switching outputs Number of switching outputs 8 Switching voltage AC 24 V The supply is AC 24 V from island bus; the triac closes the contact to (system neutral) Max. current load AO 3-Pos triac AO PWM BO Triac NO/ NC Total per module 250 ma / 6 VA per output 125 ma / 3 VA per output *) 125 ma / 3 VA per output *) 1 A / 24 VA for all 8 outputs *) 250 ma / 6 VA per output if only 4 outputs per module are used Max. Switch-on current per output 500mA / 12 VA for max. 90 s Signal cables Cable material Solid or stranded copper wire Cable cross section See manual CM110562 Permitted cable length max. 300 m AC output (Terminals Voltage Ac 24 V 2, 6, 10, 14, 19, 23, 27, 31) Fuse T 10A, in power supply module / bus connection module Caution! se cable cross section suited for 10 A according to local regulations. 4 / 8

Connection terminals Test plug socket (test terminals) Caution! Mechanical design Rising cage terminals Wire 1 x 0.5 mm 2 to 4mm 2 or 2 x 0,6 mm to 1.5 mm 2 Copper stranded wire without ferrules 1 x 0.5 mm 2 to 2.5 mm 2 or 2 x 0,6 mm to 1.5 mm 2 Stranded wire with ferrule (DIN 46228/1) 1 x 0.25 mm 2 to 2.5 mm 2 or 2 x 0,6 mm to 1.5 mm 2 se cable cross section suited for 10 A according to local regulations. Screwdriver No. 1 Screwdriver for slotted or recessed-head * screws with shaft diameter 4.5 mm * Combined slotted / recessedhead screws from mid-2012 Max. tightening torque 0.6 Nm Pin diameter 1 x 1.8 to 2.0 mm Classification per EN 60730 Operation of automatic controller Degree of pollution Mechanical design Housing protection type Degree of protection as per EN 60529 Front parts in DIN excerpt Terminal part Environmental conditions Operation Climatic conditions Temperature Relative humidity Mechanical conditions Transport Climatic conditions Temperature Relative humidity Mechanical conditions Type 1 2 Safety classes III IP30 IP20 As per IEC 60721-3-3 Class 3K5-5...50 C 5 95% r.h. Class 3M2 As per IEC 60721-3-2 Class 2K3-25...70 C 5 95% r.h. Class 2M2 Standards, directives and approvals Environmental compatibility Product standard EN 60730-1 Automatic electrical controls for household and similar use Electromagnetic compatibility (Applications) For use in residential, commercial, light-industrial and industrial environments E conformity (CE) CM1T10870xx *) L certification (S) L 916, http://ul.com/database RCM-conformity (EMC) CM1T10870en_C1 *) EAC conformity Eurasia conformity Product environmental declaration (contains CM2E8179 *) data on RoHS compliance, materials composition, packaging, environmental benefit, disposal) Color Terminal base and electronics unit RAL 7035 (light-gray) Dimensions Housing as per DIN 43880, see dimensions Weight With/without packaging 178 / 199 g *) The documents can be downloaded from http://siemens.com/bt/download. 5 / 8

Connection diagrams (example) Terminal assignment TXM1.8T Output (1) (2) (3) (4) (5) (6) (7) (8) AC 24 V supply *) 2 6 10 14 19 23 27 31 Switching output The triac closes the contact to (system neutral) 4 8 12 16 21 25 29 33 The load can be connected directly to the corresponding output terminals. No separate AC 24 V supply is required. Permanent contact BO Triac NO BO Triac NC (1) (2) (3) Triac module AC 24 V 0.125 A max. V Y1 V Y2 V Y3 2 4 6 8 10 12 Q1 K2 K3 8179z13_01 Q1 Switched load (NO contact) AC 24 V K2 Relay/Contactor AC 24 V K3 Step switch / Power surge relay / bistable relay AC 24 V Positioning signal 3-point output BO 3-Pos Triac (1) (2) Triac module V Y1 2 4 V Y2 6 8 AC 24 V 0.25 A max. Y1 M Y2 8179z17_01 Y Motor-driven actuator AC 24 V (valve, damper) Y1 Positioning signal OPEN Y2 Positioning signal CLOSE AO PWM (1) (2) Triac module AC 24 V 0.125 A max. V Y1 2 4 Y Y1 V Y2 6 8 Q 8179z18_01 Y Thermal actuator AC 24 V (valve) Y1 PWM positioning signal Q Switched load (modulating PWM AC 24 V) Caution! *) On terminals 2, 6, 10, 14, 19, 23, 27, 31, use cable cross section suited for 10 A according to local regulations (T 10A fuse in the power supply module / bus connection module). 6 / 8

Dimensions Dimensions in mm 90 67 45 22 44 70 77.5 7.1 98 108 64 3 8172M01 7 / 8

Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2012 Delivery and technical specifications subject to change 8 / 8