Instruction Manual. Breath Alcohol Tester. Advanced fuel cell sensor Personal & professional use alcohol tester

Similar documents
AlcoScan AL-5000 User s Manual

ExStik TM ph Waterproof Meters

WS-9005TWC 915MHz WIRELESS RAIN GAUGE INSTRUCTION MANUAL

el-720 Carbon Dioxide Gas Leak Detector User s Guide

e I N S T RUC TION M ANU A L

AlcoQuant Breathalyser Operating instructions

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Light Meter (Foot Candles)

Instruction Manual Temp 4/5/6 Temperature Meter Series

AlcoSense Lite and Elite Manuals

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

Model: Manual DC: WIRELESS COLOR FORECAST STATION

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Mini Digital Altimeter & Climb rate & Barometer & Thermometer & Compass & Weather forecast & Time

Combustible Gas Leak Detector 720b

Alarm Clock USER GUIDE

RT-1261A Ear and Forehead Thermometer Owner s Manual

WIRELESS WEATHER STATION Model USER'S INSTRUCTIONS

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

FARMEX HT-PRO OPERATING INSTRUCTIONS PORTABLE MOISTURE AND TEMPERATURE TESTER FOR BALED HAY

Forehead. Use and Care Manual. Thermometer IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Model V977

Optical Power Meter. Specification & User Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Milwaukee USER MANUAL

Instruction Manual HI Refractometer for Sucrose Measurements

User's Guide. Integrating Sound Level Datalogger. Model Introduction

High Temperature InfraRed Thermometer with Laser Pointer

Weather Radio Alarm Clock

Atomic Alarm Clock Instruction Manual

Dual Laser InfraRed (IR) Thermometer with Color Alert

PIR-1 Owner s Manual

Tympanic Thermometer

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

Dual Laser InfraRed (IR) Thermometer

Soil Sensor Reader PRODUCT MANUAL

Table of Contents Function Keys of Your RF Remote Control Quick Setup Guide Advanced Features Setup Troubleshooting

INSTALLATION AND OPERATING INSTRUCTIONS

Wireless Indoor/ Outdoor Thermometer

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

User s Manual for TPMS-203-RVT

microlife PF 100 Electronic Asthma Monitor Instruction Manual (1-15) Moniteur d'asthme électronique Mode d'emploi (16-31) Monitor electrónico para el

Dual Laser InfraRed (IR) Thermometer

Microwave Meter. Instruction Manual

ViviCam 25 Digital Camera User s Manual

10x25 Digital Camera Binoculars INSTRUCTION MANUAL

CATEYE STRADA DIGITAL WIRELESS

Instruction manual for Firstline FCS12000CH

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

Operating Manual Remote Cost Control Monitor

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

FRX3 Hand Turbine AM/FM/Weather Alert Radio with USB Smartphone Charger

Alarm Clock USER GUIDE

My Weigh Ultraship Series User Manual

DETA AP-10. Passport. Electromagnetic Field Treatment Device. ELIS Research and Development Enterprise

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

EzFlex Combustible Gas Leak Detector Model EZ40

Ultrasonic Distance Meter. Operation Manual

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

User's Guide. Pinless Moisture Meter. Model MO257

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Reizen Atomic Talking Analog Alarm Clock Item # Instruction Manual

Optical Wireless Mouse. User s Manual

Solar Controller / Battery Charger User s Manual

MEMO ALARM CLOCK Operating Manual

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

IN-OUT Thermometer with Cable Free Sensor and Clock

4-Channel Thermometer / Datalogger

ADVANCED INTERNET DOWNLOADABLE POSTAL & SHIPPING SCALE

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Touchless Forehead Thermometer

APP CLOCK INTRODUCTION

Getting started with

INSTRUCTION MANUAL Contactless Clinical Infrared Thermometer GT-101

2 WORD A4 E / / C A 8010 GA + Kal / GA Alle Sprachen

digital fever alert ear thermometer suitable from birth instruction manual

Part # rev 1. American Diagnostic Corporation 55 Commerce Drive, Hauppauge, New York

Ground Resistance Clamp-On Tester

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

TABLE OF CONTENTS 11.0 WARRANTY

AM/FM Portable Radio

User's Guide Integrating Sound Level Datalogger Model

Operating Instructions MA 27

INSTRUCTION MANUAL DTH Fax: (503)

3 WATT LED SPOTLIGHT Model No. SLM

August International Ltd United Kingdom Telephone: +44 (0)

Vibrating Alarm Clock. Model VA-3

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

ViviCam 5024 Digital Camera

How To Use A Meter

VIBRATION WATCH with: Vibration Alarm (won't disturb others). Beep Alarm (optional) Electro-Luminescent (EL) back light (for viewing display at

12 Volt 30 Amp Digital Solar Charge Controller

Your Simple Guide to Battery. Replacement. Customer Care:

WIRELESS MULTI-ZONE DIGITAL WEATHER CENTER. Model No User s Manual

CareTemp Touch Free Thermometer. Directions for use

Phoenix Body Fat Scale Manual

Wolverine Data PASS Portable Scanner User Manual V1.0

Part I - Installation

Transcription:

Breath Alcohol Tester Advanced fuel cell sensor Personal & professional use alcohol tester DA-7100 DA-7100 Instruction Manual Please read the user's manual carefully before use.

Important safety information Before using the alcohol tester, read all instruction manual carefully and practice the test. Maintenance and calibration should be performed by experts. Test should be performed after 20 minutes after eating, drinking or smoking, if failure to wait 20 minutes may result in invalid results or incorrect results. Residual alcohol in the mouth can distort the measurement. Aromatic drinks or mouth sprays containing alcohol can interfere with measurements. In this case, wait for 20 minutes or rinse the mouth with pure water. Do not permit to blow cigarette smoke into the tester which may damage the sensor. Do not drink and drive, even small amount of alcohol can result in driving impairment. Recommended to use calibration service every 12 months or after 500 times tests. Do not use this device as a tool to determine "drink and drive". The manufacturer and the sellers will not take any legal responsibility for the test results. When not used for a long time, keep the device after taking out the batteries. In case of testing after long-term storage, there might be high tolerance of test results for the first 3 tests. Replace the batteries when the battery indicator icon reaches empty for the accuracy reason. In case the measured value is higher than 0.1%BAC and you try again without interval, then warm up time might be delayed. Perform a test within the operating temperature, which is specified in the instruction manual.

Introduction Thank you for purchasing our breathalyzer, Alcofind DA-7100 which is a personal & professional use alcohol tester with extremely high-reliability. It can be used for hospitals, schools, and many other segments. It measures estimated B.A.C(Blood Alcohol Content) in human breath by means of a fuel cell sensor which is high durable sensors and providing accurate breath alcohol results. Contents Digital breathalyzer Alcofind DA-7100 2 (two) AAA size batteries 6 (six) mouthpieces Carrying case Hand strap User's manual Name of each part 1. Mouthpiece 2. Mouthpiece slot 3. Display 4. Power & Start button 5. Battery cover <Front> <Back> Preparation Install two AAA batteries in the battery compartment by paying attention to the battery polarity. Gently pull the cover down 2 x AAA batteries (1.5V Alkaline)

Insert a mouthpiece into the port on the side of the alcohol tester. Ensure whether it is securely fit or not. A new mouthpieces is to be used for every person tested. Insert a mouthpiece into the port gently! Do not permit to blow cigarette smoke into the tester. Performing the measurement Press the power button The total number of test performed will be displayed briefly and start countdown. When the countdown reaches zero with a double beep sound, three dashes ( ) will be displayed and "START" will flash. Take a deep breath and blow the mouthpiece for five seconds until there is a double beep sound. When the sampling was successful, LCD outer lines will be turning along the edge of LCD as you can see the picture. After a few seconds(depending on the alcohol level), the estimated BAC(Blood Alcohol Concentration) will be displayed. The value will flash for several seconds. If you want to test again, press the start button to restart the countdown cycle. The tester automatically will be turned off after 15~20 seconds. Wait at least 20 minutes after eating, drinking or smoking before measurement.

Display message & Problem-solving guide MESSAGE WHAT IT MEANS Full battery Empty battery : Warns when battery is low. The unit can be operated but recommended to change new batteries for correct result! If the LCD displays "BAt", the unit cannot operate. ACTION None required. Replace new batteries. Replace new batteries immediately. If the sampling volume is too low or not sufficiently blow. If there is no breath sample blown within 30 seconds, the LCD will display "OUT". If the unit is powered on outside of the acceptable temperature range(0~40 C or 32~104F) the unit will display it. Press button again to repeat the measurement. Press button to restart the countdown cycle and retest. Repeat the test after the unit has reached a temperature within the operation range. Technical specifications Indication of B.A.C. Accuracy Warm up time Response time Sensor Dimensions Battery Life Dimensions(WxHxD) Weight Calibration Operating temperature 0.00 ~ 0.50% BAC 0.00 ~ 5.00 0.00 ~ 2.50mg/l +/- 0.005% BAC at 0.1% BAC at 25 C +/- 0.05 at 1.0 at 25 C +/- 0.025mg/l at 0.50mg/l at 25 C Within 18 seconds at 0.05% BAC Within 10 seconds at 0.05% BAC Professional Fuel cell sensor 2 (two) AAA size alkaline batteries Approx. 1000 tests 48mm x 120mm x 20mm 93g including batteries every 12 months or after 500 tests 0 ~ 40 C

Warranty The manufacturer warrants the product to be free from defects in workmanship or material (excluding calibration) under normal use either for 1(one) year from the date of purchase or 500 breath tests whichever comes earlier. The manufacturer's obligation under this warranty is limited to replacing, adjusting or repairing the unit at manufacturer's option, if returned along with proof of purchase. For any defects due to natural disaster or customer's negligence, misuse, reconstruction and repair by unau thorized person, reasonable cost shall be charged for repair or part replacement. Customer service For any questions, after-sales service, product calibration or to purchase additional mouthpieces, please contact nearest distributor. Manufacturer / Distributor :