Noren Products Heat Exchangers Low Cost, Energy Efficient Cooling for Electrical Enclosures
Overview Modern electronics continue to be placed in denser packaging and smaller enclosures, often causing overheating problems Moisture and airborne dust, oil, dirt, and other contaminants are damaging to sensitive electronic equipment. The Compact Cabinet Cooler is an air-to-air or air-towater heat exchanger that solves these problems by cooling and re-circulating the clean air inside the cabinet. At the same time, a cabinet cooler maintains the enclosure s protective seal against contaminants. They are UL/cUL Listed and come in many different integrities including NEMA 12, 4, and 4X.
Features Easy Installation Low Maintenance Energy Efficient Long Lasting Adaptable to fit Most Applications Below Ambient Cooling with Air-to-Water Units Corrosion Resistant Hazardous Location UL/cUL Units Wash-down Fans Stainless Steel Housings Custom Units Available ROHS Compliant Green Certified
Industries Aerospace Computers & Servers Defense Electrical Systems Food & Beverage Industrial Applications Oil & Natural Gas Paper & Bulk Renewable Energy Telecom & Radar Transportation Waste Water Treatment
Air-to-Air Heat Exchanger Selecting your Heat Exchanger Our user friendly online sizing program determines the correct solution for your application. Simply input the required information and the program will provide capabilities and specifications for each model of heat exchanger. There are 2 types of heat exchangers and 2 ways of determining the unit capabilities based on the user input Air-to-Air and Air-to-Water Heat Exchangers Specifications by WATTS of waste heat and Specifications by Internal Temperature Example: How many coolers to use? (1 or 2) Panel Dimensions H x W x D Panel Internal Temperature (sealed, airtight, at full power) Ambient Operating Temperature (worst case for installation site) Number of Exposed Sides CLICK Run Program BUTTON >> NOTE: Online sizing program at www.norenproducts.com/sizing
Heat Exchanger Sizing Program Category Required Units Panel Specs Exposed Sides Results Ideal Unit RUN PROGRAM NOTE: Online sizing program at www.norenproducts.com/sizing
Heat Exchanger Sizing Program Category Required Units Panel Specs Exposed Sides Results Ideal Unit RUN PROGRAM NOTE: Online sizing program at www.norenproducts.com/sizing
Heat Exchanger Sizing Program Category Required Units Panel Specs Exposed Sides Results Ideal Unit RUN PROGRAM NOTE: Online sizing program at www.norenproducts.com/sizing
Heat Exchanger Sizing Program Category Required Units Panel Specs Exposed Sides Results Ideal Unit RUN PROGRAM NOTE: Online sizing program at www.norenproducts.com/sizing
Air-to-Air Heat Exchanger Drop In Air Flow Diagram Features: Cool electronics down to slightly above outside ambient air temperature Maintains NEMA 12 seal Air is circulated inside cabinet to keep hot spots from forming Maintenance free cooling. Fans need changing only once in every four years Flange and neoprene gasket keep contaminants out Easy to install on top, door, sides, or back of cabinet One person can cut a hole in the cabinet and bolt unit on in less than one hour Low power draw, 32 watts per fan results in low operating costs and no new electrical line required Causes no condensation like air conditioners Corrosion resistant. Anodized aluminum housing (standard), Additional salt water and chemical protection available (please inquire) Allowable ambient temperature. -40 F to 160 F Explosion proof model available Oil cooling models available 115v 50/60 Hz or 220v 50/60 Hz fans, DC fans also available
Air-to-Air Heat Exchanger Small Flush Mount Air Flow Diagram Features: Thin Flush Models 1100-3300 BTU s/hr Energy Efficient Light Weight Fans of 100-215 CFM each Mounts outside, flush to enclosure Maintenance Free - Just change fans every four years Quiet - Low dba
Air-to-Air Heat Exchanger High Power Flush Mount Model Features: Most powerful Flush Models 4500-7100 BTU s/hr Energy Efficient Light Weight Mounts outside, flush to enclosure Maintenance free - just change fans every 4 years Quiet - Low dba
Air-to-Water Heat Exchanger Features: Cools below ambient 3,351; 8,557; 9,300 and 21,800 BTU s/hr Maintenance free No filters to clog No external fans Energy efficient Flush mount Available in Stainless Steel AIR-TO-WATER Compact Cabinet Cooler technology removes waste from sealed electrical panel and other enclosures. Your panel remains sealed from outside contaminated air that can damage sensitive equipment.
Air-to-Water Heat Exchanger Features: Cools below ambient 3,351; 8,557; 9,300 and 21,800 BTU s/hr Maintenance free No filters to clog No external fans Energy efficient Flush mounts on the outside
Air-to-Water Specifications 1. Rated Cooling: 980 Watts (mounted to an uninsulated 24 x 24 x 16 cabinet with 1 GPM of water at 20 C, 40 C ambient air and 60 C cabinet air temperature ) 2. Designed for surface mounting on the outside of cabinet 3. Aluminum housing (color is black) or stainless steel 4. External water inlet and outlet connections 5. Equipped with mounting gasket to maintain air tight seal 6. P unit is pressure tested to assure water tight seal 7. UL / cul listed units also available upon request (UL file # SA9567) 8. Available with 115VAC, 230VAC, and 12VDC, 24VDC, 48VDC fans 9. Vertical mounting only 10. Coolant water pressure: This unit is pressure tested to 100 PSI; safe working pressure is 60 PSI 11. Recommended coolant flow rate (gallons per minute): 1 GPM 12. For design, quote, and sizing assistance please ask our application engineer
Cost Comparisons Noren Air-to-Air Unit Purchase price: $1,400 Max install costs: $1,550 Operating cost/yr: $106 Air Conditioner Purchase price: $3,340 Max install costs: $3,917 Operating cost/yr: $825 Total Annual Cost: $261 Total Annual Cost: $1,608 $1,347 in Annual Savings
Cost Comparisons Noren Air-to-Air Unit Purchase price: $1,400 Max install costs: $1,550 Operating cost/yr: $111 Compressed Air Purchase price: $440 Max install costs: $571 Operating cost/yr: $4,631 Total Annual Cost: $266 Total Annual Cost: $4,688 $4,421 in Annual Savings
Cost Comparisons Noren Air-to-Water Unit Purchase price: $1,275 Max install costs: $1,423 Operating cost/yr: $59 Air Conditioner Purchase price: $3,340 Max install costs: $3,917 Operating cost/yr: $825 Total Annual Cost: $202 Total Annual Cost: $1,608 $1,406 in Annual Savings
Cost Comparisons Noren Air-to-Water Unit Purchase price: $1,275 Max install costs: $1,423 Operating cost/yr: $60 Compressed Air Purchase price: $440 Max install costs: $571 Operating cost/yr: $4,631 Total Annual Cost: $203 Total Annual Cost: $4,688 $4,485 in Annual Savings
Conclusion Benefits Include: Minimizes down time Cost savings Easy to design into existing applications Easy to retrofit Worry free operation Wide selection Easy to size on website Ideal Locations: Open cabinet doors with fans Dripping water from air conditioners Wash-down areas Replacing air compressor coolers Dirty and dusty environments NEMA 4 and 4X conditions High ambient conditions Corrosion Resistant Hazardous Locations Customized for special requirement
Application Picture Air-to-Air Flush Mount Units for Industrial Application
Application Picture Air-to-Water Unit for Waste Water Treatment Facility
Application Picture Air-to-Air Flush Mount Unit for Custom Radar Application
Application Picture Air-to-Water Unit for Custom Pump Station Application
Thank You Noren Products Inc. 1010 O Brien Drive Menlo Park CA, 94025 650.322.9500 sales@norenproducts.com GSA# GS-07F-0619W