Innovation in Magnetic Field Measuring Instruments. Data Acquisition and Signal Conditioning Units

Similar documents
MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Rack mounted telephone- and leased line modem for industrial applications

Impedance 50 (75 connectors via adapters)

Integrating Sound Level Meter and Datalogger

Current Monitoring Kit QUICK START GUIDE

Differential Charge Amplifier

Vibration analysis and monitoring Compact. Powerful. Modern technology.

DS 600. A contact free flux gate based current measurement sensor 600A rms

Physical Specifications (Custom design available.)

Decoding an Accelerometer Specification. What Sensor Manufacturer s Don t Tell You! David Lally VP Engineering PCB Piezotronics, Inc.

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Fluke 3000 FC Series Test Tools Technical Data

Current Monitoring Kit

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

iva Cable & Antenna Analyzer

How To Use A Detector 2

Telephone- and leased line modem for industrial applications TD-36

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

INDENT NO. : C/T/4100/ DATED :

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

WINGLIKE ELECTRONICS CO.,LTD

SOUND LEVEL METER 94405

USB-500 Series Low-Cost Data Loggers and Accessories

Product Information Sheet UH28CS-12kV Hi Pot Tester

SPECTRUM MONITOR MC-277B

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Voltech DC1000. Precision DC Bias Current Source

USB-500/600 Series Low-Cost Data Loggers and Accessories

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

DATA SHEET. TDA1510AQ 24 W BTL or 2 x 12 W stereo car radio power amplifier INTEGRATED CIRCUITS

Handheld portable appliance testers

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

TORKEL 820 Battery Load Unit

iva Cable & Antenna Analyzer

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Waveform Monitor Audio & Loudness Logging

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS


JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Type-D EEG System for Regular EEG Clinic

EGSTON Standard E2xFxWx 12W

LOXONE 12 Channel Amplifier

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

R&S ZNBT8 Vector Network Analyzer Specifications

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

Digital Magnetometer Systems - DM Series

SYSTEM DATA. IDA e Hardware Configurations for PULSE Types 3560-B, 3560-C, 3560-D and 3560-E

1. SAFETY INFORMATION

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SKF Machine Condition Transmitters (MCT) Series

Temperature & Humidity SMS Alert Controller

Ideal for high dynamic range measurements from compression to noise floor

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

DATA SHEET. TDA1518BQ 24 W BTL or 2 x 12 watt stereo car radio power amplifier INTEGRATED CIRCUITS

Measuring static magnetic fields

SL Series AC and DC Electronic Loads

PSP3. Stereo M/S preamplifier. User manual

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

TDA W Hi-Fi AUDIO POWER AMPLIFIER

Technical Information

TDA W Hi-Fi AUDIO POWER AMPLIFIER

T Substation Maintenance and Commissioning Test Equipment

SC-30 INTEGRATING SOUND LEVEL METER REAL TIME FREQUENCY ANALYZER

LM833 LOW NOISE DUAL OPERATIONAL AMPLIFIER

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc.

MANUAL PC1000R

Linear Parameter Measurement (LPM)

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

Agilent 4338B Milliohm Meter

Ordering Part Numbers:

Uninterruptible Power Supply

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Agilent 87421A/87422A Power Supply

Series AMLDL-Z Up to 1000mA LED Driver

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Analog signal converters CC-E I/I Current / current isolators

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01

SLX WIRELESS SYSTEM The out-of-the-box wireless solution

HCS-3600MB2 Conference Main Unit

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

User's Guide Integrating Sound Level Datalogger Model

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

R&S ZNC Vector Network Analyzer Specifications

Cond-IS RF Conducted Immunity System

Analogue/Digital Analogue and Differential Oscilloscopes

DC Electronic Loads 8500 series

Kit 27. 1W TDA7052 POWER AMPLIFIER

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

NEW. EVEN MORE data acquisition and test stand automation

Monitores Equipos Móviles Especificaciones de Producto

TDA W CAR RADIO AUDIO AMPLIFIER

Application Note TMA Series

TL074 TL074A - TL074B

Transcription:

Innovation in Magnetic Field Measuring Instruments Data Acquisition and Signal Conditioning Units

Data Acquisition and Signal Conditioning Units Bartington Data Acquisition and Signal Conditioning Units Bartington Instruments data acquisition and conditioning units accept analogue inputs from most of our sensors and output the signal in either analogue or digital format, depending on the unit selected. The range includes: Spectramag-6 SCU1 Mag-03DAM Product Spectramag-6 Data Acquisition Unit Function Simultaneous acquisition and digitisation of magnetic field, vibration and acoustic signals in three axes SCU1 Signal Conditioning Unit Mains powered unit providing power supply and output conditioning for three-axis magnetic field sensors. Mag-03DAM Data Acquisition Module Battery-powered acquisition and digitisation of DC and low frequency signals from one or two magnetic field sensors Bartington is a registered trade mark of Bartington Instruments Limited in the following countries: United Kingdom, Australia, Brazil, Canada, China, European Union, India, Japan, New Zealand, Norway and the United States of America.

www.bartington.com Product Compatibility Spectramag-6 SCU1 Mag-03DAM Mag-03 Mag-13 * * Mag690 Mag639 Mag648/649 Mag670 Mag678/679 * with cable adaptor

Data Acquisition and Signal Conditioning Units Bartington Spectramag-6 Data Acquisition Unit This portable six-channel 24-bit data acquisition unit is designed for the acquisition and synchroneous digitisation of signals from magnetic field sensors, accelerometers or acoustic sensors. Features Six input channels for magnetic field sensors, accelerometers or acoustic sensors Sampling rates up to 10kHz Supplied software collects and displays data in both the time and frequency domain Selectable AC and DC coupling, low-pass filtering and FFT options available Battery or mains powered Typical Applications Magnetic field and vibration surveys Pre-installation MRI/electron microscope site surveys Ambient magnetic field interferences survey Spectramag-6 Specifications Performance Number of input channels Six (2 groups of 3 channels selectable for magnetic field sensors, accelerometers or acoustic sensors) Input signal range ±10V Input frequency range Magnetic field sensors Accelerometers and acoustic sensors Resolution Sampling interval Frequency domain display options Analogue gain control Spectrum range Sensor input (magnetic field sensor) Suitable ICP vibration sensor Suitable ICP microphone Optional accessories Up to 5kHz, reduced to 1kHz (1000 gain) DC to 5kHz (DC coupling); 0.01Hz to 5kHz (AC coupling) 0.1Hz to 5kHz (AC coupling only) 24 bit A-D converter 100μs (min) to 10s (max) up to 700,000 samples (PC dependent); continuous sampling mode (slower sampling rates only) Amplitude spectrum (RMS, peak-to-peak); Amplitude spectral density (RMS/ Hz, p-p/ Hz) Software selected x1/x10/x100/x1000 Software selected as sample rate or maximum frequency Unbalanced PCB Piezoelectronics type 393A03 (1V/g) low-noise rugged PCB Piezoelectronics type 393B31 (10V/g) low-noise rugged GRAS Microphone Type 40AE (50mV/Pa) Tripod and adaptor for Mag-03 sensors Rugged carrying case

www.bartington.com Environmental Operating temperature range Storage temperature range Humidity -10ºC to +50ºC (0ºC to +45ºC for charging) -20ºC to +70ºC 0 90% non-condensing Mechanical Dimensions (W x H x D) Weight Output interface Enclosure Connectors 170 x 112 x 210mm 2.85kg USB2 Aluminium 2 x Hirose RM15TPD10P plug for magnetic field sensors 6 x BNC sockets for ICP piezoelectric vibration sensors / acoustic sensors preamplifiers 1 x USB to PC 1 x 2.1mm socket for 12V input from mains adaptor for recharging Electrical Power output to sensor Battery Battery life Battery charging time Input impedance (magnetic field sensor inputs) ICP constant current ±15V, ±90mA Internal rechargeable Li-Ion 10.8V 72Wh UN approved battery with universal mains adaptor for charging 8 hours (typical) 10 hours for full charge 1MΩ 4mA ±20% for cables up to 1km in length Software Compatibility 32 and 64 bit Windows 7, Windows 8, Windows 8.1 32 bit Windows 98, Windows NT, Windows 2000, Windows XP 32 bit

Data Acquisition and Signal Conditioning Units Bartington SCU1 Signal Conditioning Unit This mains powered unit combined power supply, display and analogue conditioning unit for use in the laboratory with compatible Bartington Instruments magnetic field sensors. It is intended for use either as a standalone three-channel magnetic field measuring instrument, or as a conditioning unit prior to A-D conversion. Features Low and high-pass filters Gain and offset controls, independent for X, Y and Z channels Powers one three-axis sensor, with sensor outputs available both as analogue voltages and on LCD displays Unconditioned and conditioned (after application of gain, offset and filtering) XYZ signals are available as analogue voltage outputs When used with Bartington balanced (differential) sensors, the unit converts their analogue outputs into unbalanced (single-ended) signals Power supply voltage to the sensor can be increased for operation over long cables (up to 500m) Typical Application Accurate laboratory magnetic field measurements

www.bartington.com SCU1 Specifications Performance Number of input channels Three (X, Y and Z) Input signal range ±10V maximum surge protection with ±12V clamp Common mode rejection ratio >70dB - fully differential input Signal coupling AC or DC depending on filter selection Internal measurement noise floor Minimum discernible input signal variation of ±0.1mV with signal/noise ratio of 10dB at all gain settings Low-pass filter High-pass filter Gain Offset range ±10V Offset control: coarse fine Display 1, 10, 100, 1000 or 10000Hz switch selected 0 (DC), 0.01 or 1.0Hz switch selected 1, 50, 100, 300, 500 or 1000 switch selected 10 turn potentiometer with polarity switch for each channel Centre-off position potentiometer 3 x 3½ digit LCD Thermal drift 6mV/hour for filtered/null signal output with gain = 300 Environmental Operating temperature range Storage temperature range Humidity 0ºC to +70ºC -20ºC to +70ºC 0 90% non-condensing Mechanical Enclosure material Dimensions (W x H x D) Weight Connectors: power input sensor input analogue output Display Aluminium 483 (19 rack) x 88 (2U) x 300mm 5.5kg 3-way IEC with integral filter (mains cable provided) Hirose RM15TRD10P 6 x BNC sockets 3 x 3½ digit LCD (resolution up to 0.1μT) Electrical Analogue output voltage Power input Fuses Power output to sensor Sensor input Maximum load ±10V unbalanced, three unfiltered, three filtered 110/220V AC Auto selected 1A, 250V rating, 20mm or 3/4 inch ±12V, ±15V, ±17V (switch selected) at 250mA; ripple <1mV p-p, short circuit protected; surge protection provided with ±18V clamp Balanced/unbalanced Unconditioned outputs: 50kΩ per channel Conditioned outputs: 50kΩ per channel Cable length Voltage setting for Mag-03MC, MS and IE sensors <100m 12V 100-300m 15V >300m 17V

Data Acquisition and Signal Conditioning Units Bartington Mag-03DAM Data Acquisition Module Designed to provide maximum resolution at low sampling frequencies, this portable, high resolution six-channel 24-bit acquisition unit is designed for the long-term recording of DC and low frequency magnetic fields. The Mag-03DAM powers one or two magnetic field sensors. If only one sensor is used, the other inputs can record analogue signals such as temperature. Features Selectable sampling frequency, resolution (16- or 24-bit A-D), and low-pass filter cut-off frequency RS232 communication Mains AC/DC adaptor supplied for battery charging, also enabling continuous operation Typical Application Earth s magnetic field monitoring Measurement of geomagnetically induced currents (GICs) in power networks Space weather monitoring Mag-03DAM Specifications Performance Number of input channels Six (2x3 channels) Input signal range ±10V Resolution Sampling rate 16- or 24-bits, 24-bit monotonicity at up to 50Hz rate (single channel only) 10Hz to 1027Hz software selectable Scaling error ±0.05% Linearity 0.002% of full scale at up to 50Hz data rate (typical) Environmental Operating temperature range Storage temperature range Humidity -20ºC to +60ºC -40ºC to +85ºC 0 90% non-condensing

www.bartington.com Mechanical Dimensions (W x H x D) Weight Enclosure Connectors: mains adaptor sensor RS232 analogue output Output interface 255 x 55 x 265mm 2.8kg Aluminium 2.1mm DC inlet 2 x Hirose RM15TRD10P 25-way D type 9-way D type RS232 Data acquisition card Lawson Laboratories type 201* * See the website of Lawson Laboratories (www.lawsonlabs.com) for more information. Electrical Battery Battery life Battery charging time Fuse 12V, 2.1Ah, lead acid 6 hours (dual sensor), 11 hours (single sensor) 10 hours (typical) 1A, anti-surge type 20mm Analogue output voltage ±10V Power input Power output to sensor Sensor input 9 to 24V DC, 120mA via mains adaptor provided ±15V, 54mA ± 10mA Unbalanced

T: +44 (0)1993 706565 F: +44 (0)1993 774813 E: sales@bartington.com Bartington Instruments Limited 5 Thorney Leys Business Park Witney, Oxford, OX28 4GE, England. DS2519/14 The specifications of the products described in this brochure are subject to change without prior notice.