ELINT: Pulsed Radar Signals

Similar documents
Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

RF Measurements Using a Modular Digitizer

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40 Calibration Curve Procedure

Numerical Parameters Analysis of Boonton 4540 Peak Power Meter

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Tektronix RSA306 USB Spectrum Analyzer

Impedance 50 (75 connectors via adapters)

Interactive Logging with FlukeView Forms

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

MONITORING PERFORMANCE IN WINDOWS 7

Fast and Accurate Test of Mobile Phone Boards

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

Filter Comparison. Match #1: Analog vs. Digital Filters

Dynamic Frequency Selection (DFS) and the 5GHz Unlicensed Band

MANUAL FOR RX700 LR and NR

Dynamic Frequency Selection Requirements

How To Use A High Definition Oscilloscope

ELAD FDM-SW1 USER MANUAL. Ver. 1.0

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

Counters and Decoders

Chapter 6 Bandwidth Utilization: Multiplexing and Spreading 6.1

MSB MODULATION DOUBLES CABLE TV CAPACITY Harold R. Walker and Bohdan Stryzak Pegasus Data Systems ( 5/12/06) pegasusdat@aol.com

SR2000 FREQUENCY MONITOR

Using Spectrum Analyzers For Signal Monitoring

Electrical Resonance

Universal Simple Control, USC-1

Field Calibration Software

CONCEPT-II. Overview of demo examples

Summer of LabVIEW The Sunny Side of System Design

Making Spectrum Measurements with Rohde & Schwarz Network Analyzers

One Port Network Analyzer

Acceleration of Gravity Lab Basic Version

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Spectrum occupancy measurement and evaluation

Power Amplifier Gain Compression Measurements

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

GSM/EDGE Output RF Spectrum on the V93000 Joe Kelly and Max Seminario, Verigy

Lecture 2 Mathcad Basics

SignalVu-PC Vector Signal Analysis Software Printable Help

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

The demo guide contains

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

Using the EBS SQL Import Panel

MestRe-C User Guide Megan Bragg 04/14/05

Experiment 7: Familiarization with the Network Analyzer

Lab 1: The Digital Oscilloscope

Lab 3: Introduction to Data Acquisition Cards

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

Agilent Modular Products M9392A PXI Vector Signal Analyzer System with Streaming Capability

LabVIEW Day 1 Basics. Vern Lindberg. 1 The Look of LabVIEW

TCB Workshop. Unlicensed National Information Infrastructure Devices (U-NII)/Dynamic Frequency Selection (DFS)

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

Agilent U2000 Series USB Power Sensors

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Case study: how to use cutoff conditions in a FRA frequency scan?

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Application Note Noise Frequently Asked Questions

Making Basic Measurements. Publication Number August Training Kit for the Agilent Technologies Series Logic Analysis System

Summary of important mathematical operations and formulas (from first tutorial):

Part 1: Background - Graphing

R&S FPS-K10 GSM Measurement User Manual

HD Radio FM Transmission System Specifications Rev. F August 24, 2011

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

AC : MEASUREMENT OF OP-AMP PARAMETERS USING VEC- TOR SIGNAL ANALYZERS IN UNDERGRADUATE LINEAR CIRCUITS LABORATORY

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

1. Installing The Monitoring Software

USB 3.0 CDR Model White Paper Revision 0.5

Interference Analysis

Realtime FFT processing in Rohde & Schwarz receivers

SIGNAL AND SYSTEM LEVEL SIMULATIONS ON WIDEBAND INTERCEPT RECEIVERS

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

Probability and Random Variables. Generation of random variables (r.v.)

RECOMMENDATION ITU-R SM Measuring sideband emissions of T-DAB and DVB-T transmitters for monitoring purposes

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

FREE FALL. Introduction. Reference Young and Freedman, University Physics, 12 th Edition: Chapter 2, section 2.5

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

Use and Application of Output Limiting Amplifiers (HFA1115, HFA1130, HFA1135)

Spectrum Analyzer. Software Instruction Manual

Tutorial for Tracker and Supporting Software By David Chandler

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

AM/FM/ϕM Measurement Demodulator FS-K7

Excel -- Creating Charts

DT3: RF On/Off Remote Control Technology. Rodney Singleton Joe Larsen Luis Garcia Rafael Ocampo Mike Moulton Eric Hatch

CS311 Lecture: Sequential Circuits

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

DAS202Tools v1.0.0 for DAS202 Operating Manual

Logging of RF Power Measurements

Dash 18X / Dash 18 Data Acquisition Recorder

Using R&S FSW for Efficient Measurements on Multi- Standard Radio Base Stations Application Note

Jitter Measurements in Serial Data Signals

Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis

Beginners Guide to the TDS 210 and TDS 220 Oscilloscopes

Transcription:

ELINT: Pulsed Radar Signals Kyle A. Davidson, M.A.Sc. his lab serves as an introduction to the Agilent 89600 Vector Signal Analysis software, and how it can be used as a tool for analyzing pulsed radar signals for the purposes of gathering Electronic Intelligence (ELINT). This will occur in two parts, the first is a progressive walk-through of a signal analysis for three different cases. Then, a series unknown signals will be presented for independent study and analysis. T 1 Introduction This lab serves as a mechanism for you to learn how to apply the Agilent 89600B Vector Signal Analysis (VSA) software to the process of gathering ELINT on pulsed radar signals. In order to learn these skills, you ll be presented with a series of progressively more complex radar signals for analysis. Starting with a pulsed radar signal, we ll then examine Linear Frequency Modulation (LFM), and finally, frequency hopping. You ll then be on your own to analyze several unknown radar signals. The goal at all stages of this lab is to gather enough information to completely characterize the signal, in order to create a Pulse Descriptor Word (PDW). This PDW would then be used by a EW system to identify and attack radar signals. c 2015 by Kyle A. Davidson Page 1 of 8

2 Pulsed Radar Signal To start, we will analyze the simplest class of radar signal, an unmodulated pulse. This will show you how to use the basic measurement features of the VSA for radar applications. Note For more details on any of these processes, see the video Introduction to Radar ELINT and the 89600 VSA Software on YouTube. 2.1 Setting up the VSA Begin by loading the recorded signal file and setup four plots: File Recall Recall Recording... Radar 1 - Simple Pulse.sdf Setup the VSA to display 4 plots of the following: A: Ch1 Spectrum - Log Mag B: Ch1 Main Time - Log Mag C: Ch1 Spectrum - Spectrogram D: Ch1 Main Time - Wr Phs The Spectrum or Main Time choice is found through the plot tabs, in their upper right. The specific data to be plotted is then easily changed by left clicking on the label for the y-axis, and either double clicking for a set of options, or simply scrolling the mouse wheel. The results will start to resemble, Fig. 1. The next step is to setup a trigger to capture the pulse in the time domain. Essentially the VSA software is only looking at a very limited set amount of time, and the radar is often no transmitting within that window. Knowing this we set a trigger that goes off under certain conditions, in this case the presence of a pulse. Go to Input Playback Trigger... Change the style to Magnitude = 10 mv Change the Delay to 1µs (This shifts the frame of reference slightly, showing the signal starting at 1 µs before the trigger.) At this point we need to adjust the measurement parameters to view multiple pulses at once. Simply, we re increasing the length of time the VSA software is looking at. c 2015 by Kyle A. Davidson Page 2 of 8

Figure 1: VSA display of the pulsed radar signal. Go to Measurement Setup ResBW (Resolution Bandwidth). Select Window Type: Uniform window. Set frequency points to 102401. In the Time tab, set the Main Time Length to 77 µs. Alternatively, the length of time displayed can be changed on the lower right of your main plot, it will say TimeLen and now have 77µs next to it. At this point it is also recommended to right click on each plot, and select Auto Scale to optimize the graph s scales. Now, if you d like to slow down the signal playback (this is optional). Go to Measurement Setup Time Change the Max Overlap (Avg Off) to 99 % Four pulses should now be visible on the display, which you should pause. We can now view all the aspects of the pulse, and characterize it. 2.2 Measuring the Pulse Length and PRI Now that we ve setup our system to analyze the radar signal, the first step will be to conduct some time domain measurements: the pulse length (τ), and Pulse Repetition Interval (PRI). c 2015 by Kyle A. Davidson Page 3 of 8

Right click on the LogMag plot in the time domain, and click on the green plus sign next to Marker1. You now have a green marker that you can move to the rising edge of the first radar pulse. Right clicking again, add a second marker and place it at the trailing edge of the first pulse. Now, right clicking to bring up the menu again, change marker 2 from a normal maker to a Delta, this measures the change in time from marker 1 to marker 2. The second marker s measurement will now be in the upper right of this plot, indicating the measured change in time of about 1µs. To find the PRI we simply place the same two markers at the start of two sequential pulses. The VSA will then display the time delta, approximately 20 us, which is the PRI. The PRF is the inverse of this number, or 50 khz. 2.3 Measuring the Spectrum The next stage is to gather some basic information on the signal in the frequency domain. This means the power, centre frequency, bandwidth, etc. To reduce the computational overhead, change the observed time to 10 µs. This will cover one pulse of the signal, and let us characterize some elements of it. In the Ch1: Band Power. Spectrum - Log Mag window, right click and select Show Then centre this marker over the peak, and move the left and right boundaries to cover the spectrum of interest. From the spectrum display we can gain several pieces of information. The first is the transmitted frequency, it is 4.0 GHz, and the bandwidth can be read directly from the marker display, using the Show Band Power tool. The occupied band has a power of -24.5 dbm, and we can then use the delta marker again to measure the bandwidth (around 2.5 MHz). c 2015 by Kyle A. Davidson Page 4 of 8

Figure 2: Phase versus time of a pulse radar signal. 2.4 Measuring the Phase and Modulation The basic radar signal is now characterized, with its PRI/PRF, pulse length, bandwidth, and centre frequency. This is enough information to attack it with basic noise jamming, but not deception jamming. To deceive this radar, we need to understand its modulation. Examine the Ch1:Main Time - WrPhs (wrapped phase) display. This graph shows the plot of the signal s phase, and in the case of the simple pulsed radar, and should look like Fig. 2. As you can see, the signal is very noise for long periods, as the VSA attempts to measure the phase of noise between pulses. Then, while the pulse is transmitting, a flat line is present representing no change in phase. The same line can be seen if the plot is changed to Ch1:Main Time - Delay. In both cases the implication is simple, the constant phase during the pulse implies zero phase or frequency modulation. 3 Analysis of a Chirped Pulse Having measured the characteristics of a simple unmodulated radar pulse, we can move onto more practical radar signals. In this case we will analyze a very similar radar signal, but with a Linear Frequency Modulation (LFM), or c 2015 by Kyle A. Davidson Page 5 of 8

Figure 3: The VSA dsiplay for the chirped radar pulse. chirp, applied to the pulse. This will increase the signal bandwidth and, as a result, the range resolution. Load the Radar 2 - Chirp file, while keeping the same displays open. The resulting VSA display should look like Fig. 3. Here we can see some major changes from the previous signal. The process to measure the PRI, pulse length, bandwidth, centre frequency, etc. are all the same with the chirped signal. The key differences can be seen on the right-hand side of Fig. 3, where the phase versus time is measured. During the length of the pulse, we can see two issues affecting the phase. First, in the wrapped phase display, the phase is clearly changing in a symmetric manner. Second, in the delay plot, a straight diagonal line is present. This is the characteristic of a Linearly Frequency Modulated (LFM) radar pulse. In the Delay plot, we can measure the actual bandwidth it is sweeping over, and knowing the pulse length, how fast it does so. To measure this we place two markers on the Ch1:Main Time - Delay plot, at either edge of the straight line. Change the second marker to a delta of the first, and read the difference off the plot. The result should be approximately 30 MHz. This is the bandwidth the LFM signal is sweeping over for the duration of the pulse. c 2015 by Kyle A. Davidson Page 6 of 8

Figure 4: The VSA display of the frequency hopping radar signal. 4 Frequency Hopping Waveforms To further complicate matters, were now going to deal with frequency hopping signals. This will provide a signal with a much more complicated analysis in the frequency domain. Load the file Radar 2 - Chirp Hopping. Change your displays to show: A: Ch1 Spectrum - Log Mag then press the show cumulative history button B: Ch1 Main Time - Log Mag then press the Spectrogram button C: Ch1 Main Time - Wr Phs D: Ch1 Main Time - Delay E: Ch1 Main Time - Log Mag Maintain the 10 mv playback trigger The display should then look like Fig. 4. The VSA is triggering on each pulse, but as you can see in the spectrogram, and due to the digital persistence, each pulse hops to another centre frequency. If you change the time observed to around 100 µs, the hop pattern becomes visible. c 2015 by Kyle A. Davidson Page 7 of 8

In this case, it is the same 30 MHz chirp you saw in the last signal, but the centre frequency sequentially hops from 3.975 GHz, to 4.000 GHz, then 4.025 GHz, before looping through from 3.975 GHz all over again. 5 Unknown Signals Now that you understand how to use the 89600B software to analyze radar signals, here are two files to examine: Radar 4 - Unknown Signal 1 Radar 5 - Unknown Signal 2 Note In the second signal, the PRF and pulse length are inconsistent... c 2015 by Kyle A. Davidson Page 8 of 8