CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Similar documents
I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Series 71, 72, and 76 Modutrol IV Motors

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Digi-Motor Installation Guide

Series 90 Modutrol IV Motors

INSTALLATION INSTRUCTIONS

T7079A,B Solid State Remote Temperature Controllers

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

ENCL-MZ800-WAL ENCL-MX800-PAN MNL TAC I/A Series MicroNet MN 800 Series Controller Installation Instructions. Application.

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Telefon (+45) Telefax (+45) Installation and operating manual

Radiant Temperature Sensor TY7321

Model 201 Wiegand Touchpad Reader Installation Guide

Air damper actuators

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Absolute Rotary Encoder E6CP

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

System 350 A350E Electronic Cooling Control

Duct Humidity Transmitter

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

WE-350 Series ¼ Turn Electric Actuator

Operating Instructions

Part I - Installation

Your safety and the safety of others are very important.

Capacitive Prox E2K-X

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

System 350 A350R Electronic Temperature Reset Control (with Relay)

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

Single Phase Soft Starter

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Installation Instructions

Owner's Copy December 14, 2011 ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS

MCR1900 Media Converter 19-Slot Chassis

MNL-10Rxx Series MNL-15Rxx Series MNL-20Rxx Series

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

SPEED CONTROL SYSTEM

Operating Instructions

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

±15 V Current-Limited Power Supply

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

HMI display Installation Guide

NEXUS FX04 and FX04-1 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION. FX04-1 Shown

User Guide. HDMI Active Cable Extender. DVI-7370c

Water Leak Detection System

How To Power A Schen

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Manual. Solar Fountain Mobile Phone Charger

SX460. Generator Automatic Voltage Regulator Operation Manual

Field Commander Wiring Manual

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Advantium 2 Plus Alarm

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Installation Instructions

5800 Temperature Sensor Cable Assembly

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

Know-how makes the difference. Electrical Actuators

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

IO-DIM6 6-Channel, Digital to Analogue Converters

TorqPlus TM Electric Valve Actuators and Controls

Provides one channel for Ethernet over existing

LIEBERT VNSA Installation Sheet

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Seven function digital multimeter

G670 Intermittent Pilot Ignition Controls

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

IOM SERIES 820-E/P Electro-Pneumatic Positioner

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Intersection Preassembled 19-inch Rack

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

HotSwap MBP Maintenance Bypass

Cooktop Low-Profile Ventilation Hoods

Combustible Gas Transmitter RK-05

LED MOTION ACTIVATED FLOOD LIGHT

! WARNING. Before using product, read and understand instructions.

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

1000 Series. Electronic Digital Actuators. Table of Contents

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Transcription:

TAC 54 Clifford Avenue P. O. Box 940 Loves Park, IL 6-940 www.tac.com CP-80-xxx Series to 5 Vdc Input Electronic General Instructions Application The CP-80-xxx Series electronic actuator drive is designed to process a variable to 5 Vdc signal from a controller to provide proportional control of an electric gear train actuator. Features Mounts directly onto TAC proportional, electric, gear train actuators. Fixed to 5 Vdc operating range. 4, 0, and 40 Vac models available. Color-coded pigtail leads. Applicable Literature TAC Environmental Controls Cross-Reference Guide, F-68 TAC Environmental Controls Reference Manual, F-68 TAC Environmental Controls Application Manual, F-5 TAC Pneumatic Products Catalog, F-78 MP-xx Series, MP-4xx Series, MP-xxx Series, and MP-4xxx Series Reversible and Proportional Electric s General Instructions, F-5479 Printed in U.S.A. 8-06 Copyright 006 TAC All Rights Reserved. F-4940-5

SPECIFICATIONS Inputs Control Signal: Range, to 5 Vdc, nonadjustable. Span, Refer to Table-. Start Point, Refer to Table-. Power Requirements: Refer to Table-. Power Supplies: Refer to Table-. Outputs Connections: Color-coded pigtail leads. Mounting: Directly to an actuator. The upright position is preferred, but other positions are acceptable. Case: Bakelite. Environment Ambient Temperature Limits: Shipping & Storage, -40 to 60 F (-40 to 7 C). Operating, -40 to 6 F (-40 to 58 C). Humidity: 5 to 95% relative humidity, non-condensing. Locations: NEMA Type. Agency Listings UL 87: Underwriters Laboratories (File #E949 Category Temperature Indicating and Regulating Equipment). CSA: Canadian Standards Association (File #LR78). Table- Specifications. Part Number Power Requirement Vac, 4.8 VA 50/60 Hz (+0/-5%) CP-80-04 4 CP-80-0 0 CP-80-40 40 Power Supply b 0 Vdc, 50 ma regulated and filtered Start Point of Adjustable a from to Vdc input Factory-set at 6 Vdc a Remove the TAC logo, then turn the start point potentiometer CW to increase the start point. b The power supply must not be connected to the +0 (red) of other supplies. Span Fixed at Vdc for full actuator stroke Table- Typical s. a Power Torque Stroke Spring Internal Series 60 Hz Amp Lb-in. N-m Degrees Return Transformer a MP--500 4. 50 5.6 80 No MP-6 4.5 50 5.6 80 CW No MP-7 4.5 50 5.6 80 CCW No MP-8 4.5 0 4.9 80 No MP-50-500 0 0.5 50 5.6 80 Yes MP-465 0 0.5 50 5.6 80 CW Yes MP-475 0 0.5 50 5.6 80 CCW Yes MP-48 0 0.5 0 4.9 90 Yes MP-485 0 0.5 0 4.9 80 Yes MP-486 0 0.5 0 4.9 80 Yes MP-495 0 0.95 450 50.8 80 Yes Units with a - suffix, e.g. MP-xxxx-xxx--x, include a built-in transformer (used for TAC Microtherm or with AE-504) with secondary leads wired externally to terminals seven and eight of the actuator. Red (4 Vac) to terminal eight and Blue ( Vac) to terminal seven. When these actuators are used with controllers other than TAC Microtherm or AE-504, disconnect the Red and Blue leads and tape off. Note: Models prior to - suffix had transformer wired directly to potentiometer. To disconnect the transformer, remove the back plate of the actuator, disconnect and tape the transformer leads. Copyright 006 TAC All Rights Reserved. F-4940-5

ACCESSORIES None TOOLS Appropriate screwdriver TOOL-0 Calibration kit for TAC System 8000 TM TYPICAL APPLICATIONS (wiring diagrams) Refer to Figure- for a service application wiring diagram showing the connections between a CP-80-xxx series drive and an MP-xx, MP-4xx or MP-xx series actuator. MP-XX, MP-4XX, MP-XX Series Yellow (OP) CP-80-XXX Yellow Blue Red Brown/White Brown Brown/Black Red/Black Blue/Black Yellow/Black Wire Nuts Blue (COM) Red (+0) Terminals 7 4 8 x 00 Ohm Slidewire Limit Switches Typical Controller TP-80 CP-80 Shading Windings Field Winding Part Number Vac Color CP-80-04 4 Black/Blue CP-80-0 0 White CP-80-40 40 White/Black Black L (H) L (G) Power For actuator with internal transformers. Disconnect red and blue leads from actuator terminals 7 and 8 and tape off. Diagram shown: increasing input causes CW actuator rotation. All references to the direction of rotation are determined by looking at the actuator output shaft. For CCW rotation with an increasing input signal, reverse the wires to terminals 7 & 8 and &. Figure- Service Application Wiring Diagram. INSTALLATION Inspection Inspect the package for damage. If damaged, notify the appropriate carrier immediately. If undamaged, open the package and inspect the device for obvious damage. Return damaged products. Requirements Tools (not provided): Appropriate screwdriver Digital Volt-ohm Meter (DVM) Training: Installer must be a qualified, experienced technician Other accessories as appropriate Wiring diagrams F-4940-5 Copyright 006 TAC All Rights Reserved.

Warning: Electrical shock hazard! Disconnect power before installation to prevent electrical shock or equipment damage. Make all connections in accordance with the electrical wiring diagram and in accordance with national and local electrical codes. Use copper conductors that are suitable for 75 C. Caution: Do not exceed the ratings of the device(s). Static charges produce voltages high enough to damage the electronic components. Follow static electricity precautions when installing or servicing the device(s). Discharge any static electricity you may have accumulated. Discharge static electricity by touching a known, securely grounded object. Avoid locations where excessive oil, dust, moisture, corrosive fumes or vibration, or an explosive atmosphere is present. Mounting Upright mounting of the drive is preferred, but other positions are acceptable. Mount the drive onto an actuator as follows:. Insert the drive s two /" conduit connectors into the two /" knockouts provided on the actuator casing. Refer to Figure-, Figure-, and Figure-5. Left-Side Mounting (Optional) Right-Side Mounting (Typical) Figure- Mounting Position of on. Caution: The power wires must always be inserted directly into the power wiring compartment of the actuator. If the optional mounting position for the drive (refer to Figure-) is used, it is required that the wires of the drive are routed to exit through its other conduit bushing.. Secure the drive to the actuator with the two locknuts provided. Refer to Figure-. 4 Copyright 006 TAC All Rights Reserved. F-4940-5

Power Wiring Compartment L (H) L (G) Barrier To Controller L (H) 5 L (G) 6 8 x 7 4 Location of Start Point Adjustment Potentiometer Low Voltage Wiring Compartment Top view. Remove green wire from terminal X. Right-side mounting is shown. Figure- / Wiring and Mounting Arrangement. WIRING Power Wiring All the power to the drive is supplied by the electric actuator onto which the drive is mounted. Refer to Figure-4. Refer to Table- for power wire selection. Table- Power Wire Selection. Voltage Vac 4 0 40 Wire Size AWG Maximum Run (each run has two wires) ft (m) 4 40 (4) 5 (76) 4 00 (640) All the applicable actuators have a barrier that separates the power wiring compartment from the low voltage wiring compartment. The power wiring for the 4 Vac actuators may be per Class circuit requirements if the auxiliary switch (terminals one, five, and six) is 4 Vac, or is not used. The power wiring must be per Class circuit requirements if the actuator is line voltage or if the auxiliary switch is powered by line voltage. The connections to the low voltage wiring compartment may be per Class circuit requirements. Input Wiring The drive s two input wires, which must be connected to the controller, are color-coded blue (COM) and yellow (OP). Refer to Figure-4. Use 8 gage, three-conductor, twisted leads (part number W-0) for runs of up to 000 ft. (05 m) between the controller and the actuator. Use larger-sized leads for longer runs. Caution: Use 8 gage, shielded, twisted cable when it is necessary to install the signal leads in the same conduit with the power wiring, or when high RFI/EMI generating devices are near. Terminate the shielding on the signal leads at one end only, using the controller s COM (negative) terminal. Grounding the shielding at both ends could create a potential difference in the shielding, which may affect the signal voltage carried by the leads. F-4940-5 Copyright 006 TAC All Rights Reserved. 5

Yellow / Black Blue / Black Red / Black Brown Red Red (+0) Yellow Yellow (OP) Blue Blue (COM) 4 5 6 7 X 8 H G Brown / White Brown / Black Black CP-80-XXX Typical Controllers TP-80 CP-80 4 6 AC Supply CP-80-04 can be used with the following electric actuators: MP-6, 7, 8, 8, -500 and 97. CP-80-0 can be used with the following electric actuators: MP-465, 475, 48, 485, 486, 495, and 50-500. CP-80-40 can be used with 40 Vac electric actuators. (Available as a standard option.) rotates clockwise on increase in input signal. To rotate actuator counterclockwise on an increase in input signal, reverse blue/black and red/black leads and reverse brown/black and brown/white leads. 5 Part Number Vac Color CP-80-04 4 Black/Blue CP-80-0 0 White CP-80-40 40 White/Black 4 5 6 4 Vac s Only. These terminals are marked L & L on 0V and 40V actuators. 0V and 40V actuators must not have a built-in transformer, or if a built-in transformer is present, remove red and blue leads from terminals 7 and 8, and tape off. External green jumper from X to case ground (and G to case ground, for 4 Vac) on MP-XXXX-XXX-X- models only. Figure-4 Installation Wiring Diagram. ADJUSTMENTS Start Point Adjustment The start point of these actuators is factory-set to 6 Vdc and is field-adjustable from to Vdc. If a start point other than 6 Vdc is required, proceed as follows:. Peel back the TAC label from the drive, to expose the start point adjustment potentiometer. Refer to Figure-.. Disconnect the red, yellow, and blue leads of the drive from the controller.. Connect the leads of TOOL-0 to the like-colored leads of the drive. 4. Connect a DVM to the yellow (OP) and blue (COM) leads of the drive. 5. Adjust TOOL-0 until the DVM reading equals the required start point voltage ( to Vdc). 6. Adjust the actuator start point, using a small, single-slotted screwdriver, so that the actuator shaft just begins to rotate when the desired voltage is applied. 7. Press the label back onto the drive. CHECKOUT After the entire system has been installed and the actuator has been powered up, the following checks can be made for proper system operation. Positioning with Controller If the sensed media is within the controller s setpoint range, the actuator can be positioned by adjusting the controller setpoint up and down. Check for correct operation of the actuator (valve or damper) while it is being stroked. 6 Copyright 006 TAC All Rights Reserved. F-4940-5

Go, No Go Test Manual Positioning. Disconnect the field wiring from the red, yellow, and blue leads of the drive.. Apply power to the actuator.. Short the yellow and red leads of the drive. The actuator should rotate CW to its limit, unless it is rewired to rotate CCW on an increase in input signal. Disconnect the short between the yellow and red leads. 4. Short the yellow and blue leads of the drive. The actuator should rotate CCW to its limit, unless it is rewired to rotate CW on an increase in input signal. Disconnect the short between the yellow and blue leads. 5. If the assembled actuator and drive passes steps and 4, they are functioning correctly. If the assembly does not pass these steps, proceed to the next step. 6. Unhook the drive leads from actuator terminals x,, and. 7. Short actuator terminals x and two. The actuator should rotate CW to its limit. Disconnect the short. The actuator should stop rotation. 8. Short actuator terminals x and three. The actuator should rotate CCW to its limit. Disconnect the short. The actuator should stop rotation. 9. If the actuator passes steps 7 and 8, it is functioning correctly. If the actuator does not pass these steps, the drive may still be functional but the actuator must be replaced.. Apply power to the actuator.. Disconnect the actuator s control leads from the controller.. Attach the leads from the manual positioner (TOOL-0) to the like-colored leads on the drive. 4. Manually position the actuator by turning the knob of the manual positioner. 5. Check for proper operation of the valve or damper as the actuator is operated. 6. Remove power from the actuator. 7. Reconnect the actuator wires to the controller. F-4940-5 Copyright 006 TAC All Rights Reserved. 7

MAINTENANCE The drive requires no maintenance. Regular maintenance of the total system is recommended to assure sustained, optimum performance. FIELD REPAIR None. Replace an inoperative drive with a functional unit. DIMENSIONAL DATA 4" (0mm) -7/8" (48mm) -/4" (8mm) -/" (64mm) " (5mm) /" Conduit Thread 4" (0mm) Figure-5 Mounting Dimensions of CP-80-xxx Series Electronic. Copyright 006, TAC All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. TAC 54 Clifford Avenue P.O. Box 940 Loves Park, IL 6-940 F-4940-5 www.tac.com